VEVOR HM14065LCb Pool Pump Motor User Manual
- June 1, 2024
- VEVOR
Table of Contents
Pool Pump Motor
Model: HM14065LCb/HM14095LCb/HM16075LCb
HM14075LCb/HM16058LCb/HM16085ECh
HM14065LCb Pool Pump Motor
Please read these operating instructions carefully before starting to work.
We continue to be committed to provide you tools with competitive price. “Save
Half”, “Half Price” or any other similar expressions used by us only
represents an estimate of savings you might benefit from buying certain tools
with us compared to the major top brands and does not necessarily mean to
cover all categories of tools offered by us. You are kindly reminded to verify
carefully when you are placing an order with us if you are actually saving
half in comparison with the top major brands.
NEED HELP? CONTACT US!
Have product questions? Need technical support? Please feel free to contact
us:
Technical Support and E-Warranty Certificate
www.vevor.com/support
This is the original instruction, please read all manual instructions
carefully before operating. VEVOR reserves a clear interpretation of our user
manual. The appearance of the product shall be subject to the product you
received. Please forgive us that we won’t inform you again if there are any
technology or software updates on our product.
SAFETY WARNINGS AND PRECAUTIONS
- Voltage, frequency and the wiring style should be consistent with the motor nameplate, power supply voltage should be maintained at plus or minus 5% of the rated operating range.
- No more than 1000 meters above sea level.
- Ambient air temperature not exceeding 40 C.
- The motor must have a good grounding device
- Before option must measure 500-volt megohm table winding insulation resistance to ground, and its value should be more than 0.2 megohm, or to be dried.
- Before starting pull action shaft, it should be flexible rotation, no friction and collisions, running should be smooth and lightly, without stagnation and the noise, if found the strange noise, overheating, burning smell, smoke or slow speed of the phenomenon, should immediately turn off power, shutdown inspection, repair it.
- The surrounding environment should keep clean and dry and well ventilated.
- Check whether the motor fastening is fasten.
- Motor routine maintenance: Electrical outlet box part of the electrical contacts should be kept clean and good contacts, whether the motor air inlet plug, so as not to affect the motor life. Regular maintenance should be a half a year, check the motor remove dust and oil, grease and abrasion.
- The motor running check: When motor is operated it should always be paid attention to whether the load data in current with requirement, whether the bearing has phenomena of heat and leakage, if found abnormal or sound, should be stopped immediately for inspection. Until fault is identified, do not do Starting test.
GENERAL INFORMATION
Pool Pump Motor are all fully factory tested and inspected before shipping. Damage during shipment and storage can occur. Motors not correctly matched to the power supply and/or the load will not operate properly. These instructions are intended as a guide to identify and eliminate these problems before they are overlooked or cause further damage.
ACCEPTANCE
Check carefully for any damage that may have occurred in transit. If any damage or shortage is discovered, do not accept until an appropriate notation on the freight bill is made. Any damage discovered after receipt of equipment should be immediately reported to the carrier.
STORAGE
A. Keep motors clean
- Store indoors
- Keep covered to eliminate airborne dust and dirt.
- Cover openings for ventilation, conduit connections, etc. to prevent entry of rodents, snakes, birds, and insects, etc.
B. Keep motors dry
- Store in a dry area indoors
- Temperature swings should be minimal to prevent condensation.
- Space heaters are recommended to prevent condensation.
- Treat unpainted flanges, shafts, and fittings with a rust inhibitor.
- Check insulation resistance before putting motor into service.
(Consult manufacturer for guidelines).
INSTALLATION UNCRATING AND INSPECTION
After uncrating, check for any damage which may have been incurred in
handling. The motor shaft should turn freely by hand. Repair or replace any
loose or broken parts before attempting to use the motor.
Check to be sure that motor has not been exposed to dirt, grit, or excessive
moisture in shipment or storage before installation.
Measure insulation resistance (see operation). Clean and dry the windings as
required.
Never start a motor which has been wet without having it thoroughly dried.
SAFETY
Motors should be installed, protected and fused in accordance with latest
issue of National Electrical Code, NEMA Standard Publication No.
MG 2 and local codes.
TECHNICAL INFO:
Model No| HM140 65LCb| HM140 95LCb| HM160 75LCb| HM140 75LCb| HM160 58LCb|
HM160 85ECb
---|---|---|---|---|---|---
Model flange| 56J| 56J| 56Y| 56J| 56Y| 56Y
Horsepower| 0.75HP| 1.5HP| 1.5HP| 1.0HP| 1HP| 2.0HP
no-load power| ≤460W| ≤460W| ≤350W| ≤460W| ≤350W| ≤460W
ATM| 40℃| 40℃| 40℃| 40℃| 40℃| 40℃
SF| 1.5| 1.3| 1.1| 1.4| 1.25| 1.3
AMPS| 8A(115 V) / 4A(230 V)| 13.6A(1 15V) / 6.8A(23 0V)| 12.8A(115 V) /
6.4A(23 0V)| 9.8A(11 5V) / 4.9A(23 0V)| 9.0A(11 5V) / 4.5A(23 0V)| 7.8A(23 0V)
AMPS(MAX LOAD)| 10A(11 5V) / 5A(230 V)| 17A(11 5V) / 8.5A(23 0V)| 14A(11 5V) /
7A(230 V)| 12.4A(1 15V) / 6.2A(23 0V)| 11.0A(1 15V) / 5.5A(23 0V)| 10.2A(2
30V)
shaft extension| 47.5- 47.75mm| 47.5- 47.75mm| 23.01±0 .86mm| 47.5- 47.75mm|
23.01±0 .86mm| 23.01±0 .86mm
Rated Speed| 3450RP M| 3450RP M| 3450RP M| 3450RP M| 3450RP M| 3450RP M
Voltage| AC 115/230 V| AC 115/230 V| AC 115/230 V| AC 115/230 V| AC 115/230 V|
AC 230V
Frequency| 60 Hz| 60 Hz| 60 Hz| 60 Hz| 60 Hz| 60 Hz
Rotation| CCW| CCW| CCW| CCW| CCW| CCW
Insulation| F| F| F| F| F| F
Noise| ≤65dB| ≤65dB| ≤70dB| ≤65dB| ≤70dB| ≤70dB
Thread size| 3/8- 16UNC| 3/8- 16UNC| 4- φ10.8± 0.38mm| 3/8- 16UNC| 4- φ10.8±
0.38mm| 4- φ10.8± 0.38mm
outside diameter| φ142.5 mm| φ142.5 mm| φ164.0 mm| φ142.5 mm| φ164.0 mm|
φ164.0 mm
Output screw teeth| 7/16- 20UNF- 2A| 7/16- 20UNF- 2A| 1/2- 20UNF- 2A| 7/16-
20UNF- 2A| 1/2- 20UNF- 2A| 1/2- 20UNF- 2A
Screw tooth length| 14.3- 17.85mm| 14.3- 17.85mm| 12.7±0. 51mm| 14.3- 17.85mm|
12.7±0. 51mm| 12.7±0. 51mm
Product wiring diagram
Single voltage(HM16085ECb)
WIRING DIAGRAM-230V
Dual voltage specification wiring
diagram(HM14065LCb/HM14095LCb/HM16075LCb/HM14075LCb/HM1 6058LCb)
WIRING DIAGRAM-115/230V
Planing
56J(HM14065LCb/HM14095LCb/HM14075LCb)
56Y(HM16075LCb/HM16058LCb/HM16085ECb)
Product installation precautions
-
After receiving the product, open the packaging and remove it to inspect its appearance for any damage caused by transportation.
If the packaging s damaged or the product is damaged, please contact customer service or transportation company urgently. Do not install it voluntarily. -
If the product is intact, please open the rear cover of the motor as shown in the diagram.
-
Remove the exposed test wire and select a voltage specification suitable for your own use. Connect the 120/230 terminals as shown in the diagram. Except for HM16085ECD, all other motors are dual voltage motors, suitable for different household voltages.
-
To install the impeller of the swimming pool pump, it is necessary to remove the back cover of the motor and use a wrench to clamp the flat top of the main motor shaft (to prevent the motor shaft from rotating when installing the impeller). On the other side, rotate and lock the impeller onto the screw thread of the motor shaft.
-
The two white output power lines are for the convenience of testing and have no practical use. After receiving the product, installing the swimming pool pump requires removing the two test leads.
-
Motor grounding indication, connect a grounding wire to the motor grounding device.
Special attention: All motor models are wired with a default voltage of
230V before leaving the factory.
Please adjust according to your own power supply specifications upon receipt.
(If your own power supply is 230V voltage, there is no need to adjust it).
COMMON PROBLEMS AND REMEDIES
Problem 1:
When you receive the motor, please check whether the front shaft of the motor
can rotate. if you find that manual rotation is not possible.
Solution:
The concentricity of the motor may be damaged during transportation.
Please contact the after-sales for processing
Problem 2:
The motor does not work when it is powered on.
Solution:
- Please check the power supply to make sure the output voltage is correct.
- Please check the wiring carefully to make sure it’s the same as the wiring
diagram.
Problem 3:
After the motor is powered on, it rotates slowly and cannot be started normally.
Solution:
- Please check the power supply to make sure the output voltage is correct.
- Please check the wiring carefully to make sure it’s the same as the wiring diagram.
- Check whether the motor protector is intact and there is no open circuit.
Problem 4:
After running for a period of time, the motor heats up and stops working.
Solution:
Motor overloaded running, protector function. After half an hour of cooling,
try again.
Made In China
Manufacturer:Changzhou Honest Electric CO.,LTD
Address:No. 60, Yinxing Road, Zhonglou, Changzhou, Jiangsu, China
Documents / Resources
|
VEVOR HM14065LCb Pool Pump
Motor
[pdf] User Manual
HM14065LCb Pool Pump Motor, HM14065LCb, Pool Pump Motor, Pump Motor, Motor
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>