FREDRICK RAMOND FR41495 LED Chandelier Rubina Light Instruction Manual
- June 1, 2024
- FREDRICK RAMOND
Table of Contents
FREDRICK RAMOND FR41495 LED Chandelier Rubina Light
Fr41495-41498 Assembly Instructions
MOUNTING INSTRUCTOINS (STEM HUNG) Shut off electrical current before starting. If the fixture you are replacing is turned on and off by a wall switch, simply turn the switch off. If not, remove the appropriate fuse (or open the circuit breakers) until the fixture is dead.• DO NOT restore current – either by fuse, breaker, or switch -until the new fixture is completely wired and in place.
-
To begin assembly of your fixture, first remove the knurl nut
(2) out from the cluster top nipple (a) then slip fixture body along wire and lock in place with the knurl nut. See Drawing-1.
-
Slip stem (1) along wire and thread onto top nipple (a) and tighten.
-
Refer to the next page on how to hang your fixture from the ceiling.
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18) AND ANY
ADDITIONAL DIRECTIONS.
TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT
A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.
CRYSTAL INSTALLATION AND LOCATION:
Your fixture is supplied with 2 different lenght of crystal strands.
x36 = 8-7/8″L.
x40 = 13-7/8″L.
There are two ring, with small holes located inside the body frame assembly ..
The 13-7 /8″ long of crystal strands is for the top ring.
The 8-7/8″ long of crystal strands is for the bottom ring.
See Drawing 2.
Fr Is-19 Mounting Instructions
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18) AND ANY
ADDITIONAL DIRECTIONS.
TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT
A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.
- Shut off electrical current before starting. If the fixture you are replacing is turned on and off by a wall switch, simply turn the switch off. If not, remove the appropriate fuse (or open the circuit breakers) until the fixture is dead.
DO NOT restore current – either by fuse, breaker or switch – until the new fixture is completely wired and in place.
-
Fasten mounting strap (1) to outlet box (A) with the two screws (2) not provided. – see Drawing 1.
-
Thread 2 – hex nuts (3a) and (3b) onto threaded tubing (4).
-
Thread one end of threaded tubing (4) into loop (5) a minimum of 1/2’’ to 3/4’’. Tighten hex nut (3a) against loop (5) to lock loop in position.
-
Thread other end of threaded tube (4) into mounting strap approximately 1/2’’.
-
Slip canopy (B) over loop (5) and adjust height of loop so half of the threaded area on the loop is exposed – see Drawing 2 below. After loop height is adjusted, tighten hex nut (3b) up against mounting strap, tighten against mounting strap to lock loop and threaded tube in position.
-
Remove mounting strap (1) from junction box (A), and thread third hex nut (3c) onto end of threaded tube (4) above the mounting strap, tighten against mounting strap to lock assembly in position.
-
Remount mounting strap to junction box.
I.s. 18 Wiring Grounding Instructions
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (IS 18) AND ANY
ADDITIONAL DIRECTIONS.
TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT
A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS
Wiring Instructions
Indoor Fixtures
- Connect positive supply wire (A) (typically black or the smooth, unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector – see Drawings 1 or 2.
- Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
- Please refer to the grounding instructions below to complete all electrical connections
Outdoor Fixtures
-
Connect positive supply wire (A) (typically black or the smooth unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector — see Drawings 2 or 3.
-
Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
-
Cover open end of connectors with silicone sealant to form a watertight seal.
If installing a wall mount fixture, use caulk to seal gaps between the fixture mounting plate (backplate) and the wall. This will help prevent water from entering the outlet box. If the wall surface is lap siding, use caulk and a fixture mounting platform specially. -
Please refer to the grounding instructions below to complete all electrical connections.
Grounding Instructions
Flush Mount Fixtures
For positive grounding in a 3-wire electrical system, fasten the fixture
ground wire (E) (typically copper or green plastic coated) to the fixture
mounting strap (M) with the ground screw (S) – see Drawing 1. Note: On
straps for screw supported fixtures, first install the two mounting screws in
strap. Any remaining tapped hole may be used for the ground screw.
Chain Hung Fixtures
Loop fixture ground wire (E) (typically copper or green plastic coated) under
the head of the ground screw (S) on fixture mounting strap (M) and connect to
the loose end of the fixture ground wire directly to the ground wire of the
building system with appropriately sized twist-on connectors – see Drawing
2.
Post-Mount Fixtures
Connect fixture ground wire (E) (typically copper or green plastic coated) to
power supply ground with appropriately sized twist-on connector inside post.
Cover open end of connector with silicone sealant to form a watertight seal –
see Drawing 3.
Documents / Resources
|
FREDRICK RAMOND FR41495 LED Chandelier Rubina
Light
[pdf] Instruction Manual
FR41495, FR41498, FR41495 LED Chandelier Rubina Light, FR41495, LED Chandelier
Rubina Light, Chandelier Rubina Light, Rubina Light, Light
---|---