MOUNTING INSTRUCTOINS (STEM HUNG)

Shut off electrical current before starting. If the fixture you are replacing is turned on and off by a wall switch, simply turn the switch off. If not, remove the appropriate fuse (or open the circuit breakers) until the fixture is dead.
• DO NOT restore current – either by fuse, breaker, or switch -until the new fixture is completely wired and in place.
STEP 1

  1. To assemble your fixture first take the canopy (C) with stem and slip the wires exiting from the top of the fixture body (F) through the center of the stem.
  2. Now thread canopy and stem onto the top of the fixture body (F).
  3. Fixture is ready for installation.

STEP 2

  1. To mount the fixture to the ceiling, first thread the two long 8-32 screws (1) provided, into the mounting strap (2). Making sure the screws are threaded into the holes that match the mounting hole spacing (M) on canopy (3). – see Drawing 2.
  2. Attach the mounting strap to the junction box using two 8-32 screws. NOT PROVIDED.
  3. NOTE: Due to the weight of this fixture it has been supplied with a safety cable. This cable must be attached to a joist or a structure indecent dent of the junction box. Follow instruction sheet (IS-SCC) provided.
  4. Next make all necessary wiring connections following instruction sheet (IS-18) provided.
  5. Now lift fixture up to ceiling and slip the screws (1) through the holes (M) in the canopy. Push wires into junction box and hold canopy up against the ceiling and thread the barrel knobs (4) onto and of screws (1) and tighten to secure the fixture to the ceiling.

SAFETY WARNING: READ WIRING AND GROUNDING INSTRUC-TIONS (I.S. 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.
Make electrical connections from supply wire to fixture lead wires. Refer to instruction sheet (I.S. 18) and follow all instructions to make all necessary wiring connections. Then refer back to this sheet to complete installation of this fixture.

GLASS INSTALLATION:

NOTE: It is recommended that the glass be installed after fixture is hung.

  1. To install glass first remove the barrel knob with threaded stud (T) and plastic washer (P), from the top rail (R) of the fixture body (F) – see Drawing 3.
  2. Next take a glass panel (G) and align the threaded hole in the top rail with the hole in the top of the glass panel.
  3. Now thread barrel knob with stud into threaded hole in top rail, making sure plastic washer is between glass panel and base of barrel knob.
  4. Continue adding panels around the fixture until all panels are installed.

FREDRICK RAMOND JFR30103 Jolie 19 Inch 1 Light LED Semi Flush Mount - Figure
1| FREDRICK
RAMOND JFR30103 Jolie 19 Inch 1 Light LED Semi Flush Mount - Figure
2| FREDRICK
RAMOND JFR30103 Jolie 19 Inch 1 Light LED Semi Flush Mount - Figure
3
---|---|---

Wiring Instructions for 0-10 volt LED dimmer

start here

Your fixture is designed so it can use a standard incandescent dimmer, Or a 0-10 volt LED dimmer. If a 0-10 volt LED dimmer is used, it may be necessary to have additional wiring installed from the dimmer switch to the fixture. Consulting an electrician will be necessary.

  1. If using the optional 0-10 volt dimmer there will be four wires exiting the junction box. (B) Black [+], (W) White [-], wring are for the 120 / 277 voltage. The (G) Gray {-} and (P) Purple {+} are for the 0-10 volt wires from the dimmer (D) – see Drawing 1.
  2. The fixture has four wires of corrisponding colors. When make the wire connections follow the chart below.

Black (B) from junction box (J) wired to Black (B) from fixture (F).

White (W) from junction box (J) wired to White (W) from fixture (F).

Gray/Pink(G) from junction box (J) wired to Gray/Pink (G) from fixture (F).

Purple (P) from junction box (J) wired to Purple (P) from fixture (F)
Connect ground wire from fixture to ground screw on mounting hardware

INCANDESCENT DIMMER USAGE:

If using an incadescent dimmer follow manufactures instructions.
NOTE: MAKE SURE TO CAP OFF THE GRAY AND PURPLE WIRE FROM THE FIXTURE INSIDE THE CANOPY. IF THE ARE NOT CAPPED THEY CAN SHORT OUT AND CAUSE THE FIXTURE TO FAIL.

FREDRICK RAMOND JFR30103 Jolie 19 Inch 1 Light LED Semi Flush Mount - Figure
4

IS-SCC [safety cable installation]

WARNING: TO AVOID ELECTRICAL SHOCK, THIS SECTION OF THE INSTRUCTION SHEET IS FOR THE SOLE PURPOSE OF SAFETY CABLE INSTALLATION, AND IS NOT TO BE USED TO MAKE ANY ELECTRICAL CONNECTIONS.
• The safety cable must be attached to a ceiling joist or other permanent structure independent of the junction box.

  1. using a 3/16″ dia. drill, drill a pilot hole (1). It must be drilled into the permanent structure or through the junction box on the joist side were the safety cable will be attached – see Drawing 1.
  2. Insert and thread a 1/4″ hex head lag screw (2) (not included) into pilot hole.
  3. Continue installation of this ÿxture according to IS19-50 provided.
  4. After length of safety cable is determined, allow enough extra cable so it can be wrapped around lag screw. Thread lag screw to secure safety cable.

Make electrical connections from supply wire to fixture lead wires.
Refer to instruction sheet (I.S. 18) and follow all instructions to make all necessary wiring connections. Then refer back to this sheet to continue installatio of this fixture.
Drawing 1 – Safety Cable InstallationFREDRICK RAMOND JFR30103 Jolie 19
Inch 1 Light LED Semi Flush Mount - Figure 5

A Division of Hinkley Lighting, Inc.
33000 PIN OAK PARKWAY / AVON LAKE, OHIO 44012
toll free 800.446.5539 / phone 440.653.5500

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

FREDRICK RAMOND User Manuals

Related Manuals