FREDRICK RAMOND FR33326BX Atera 6 Light 45 Inch LED Sputnik Chandelier Instruction Manual
- June 1, 2024
- FREDRICK RAMOND
Table of Contents
FREDRICK RAMOND FR33326BX Atera 6 Light 45 Inch LED Sputnik Chandelier
Mounting Instructions
- Find a clear area in which you can work.
- Unpack fixture and glass from carton.
- Carefully review instructions prior to assembly.
Shut off electrical current befoer starting. If the fixture you are replacing is turned on and off by a wall switch, simply turn the switch off. If not, remove the appropriate fuse (or open the circuit breakers) until the fixture is dead.• DO NOT restore current – either by fuse, breaker, or switch – until the new fixture is completely wired and in place.
-
Determine the desired height the pendant will be installed.
-
The fixture is supplied with assorted stem sizes. Determine what combinations of stems are needed to achieve desired length – see Drawing 1.
-
Slip stems over wire and thread first stem onto top of pendant, longest stem first.
Repeat this process until all required stems are threaded together. -
Slip wire through center hole of canopy swivel and thread swivel onto the top of the last stem installed.
- Release mounting plate (3) from canopy (5) by removing screws (4)
- Secure mounting plate (3) to junction box (1) using screws (2) (not provided)
- Make wiring connections using IS-18 on the next page
- Use screws (4) to re-secure canopy (5) to mounting plate
- Refer to the next page for glass and arm assembly
- Pull arm (3) down and tighten arm sleeve (4) to lock into place
- Lamp fixture with appropriate candle base bulb (5)
- Place glass (1) over socket (2) and twist to lock into place
- Repeat steps 1-3 for the other arms
- Fixture can now be powered on
I.S. 18 wiring grounding instructions
SAFE TY WARNI NG: READ WIRIN G AND GR OUNDING INSTRUCTIO NS (IS 18) AND ANY
ADDITIONAL DIRECTIONS.
TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSU LT
A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS
wiring instructions
Indoor Fixtures
- Connect positive supply wire (A ) (typically black or the smooth, unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector – see Draw ings1 or 2.
- Connect negative supply wire (C) (typically white or the ribbed , marked side of t he two-conductor cord) to negative fixture lead (D).
- Please refer to the grounding Instructions below to complete all electrical I connections
Outdoor Fixtures
-
Connect positive supply wire (A) (typically black or t he smooth unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector – see Drawings 2 or 3.
-
Connect negative supply wire (C) (typically white or the ribbed , marked side of t he two-conductor cord) to negative fixture lead (D).
3. Cover open end of connectors with silicone sealant to form a watertight seal. -
If installing a wall mount fixture, use caulk to seal gaps between the fixture mounting plate (backplate) and the wall. This w ill help prevent water from entering t he outlet box . If the wall surface is lap siding, use caulk and a fixture mounting platform specially.
-
Please refer to the grounding instructions below to complete all electrical connections.
grounding instructions
Flush Mount Fixtures
For positive grounding in a 3-wire electrical system, fasten the fixture
ground wire ( E) (typically copper or green plastic coated) to the fixture
mounting strap (M) with the ground screw (S) – see Drawing 1.
Note: On straps for screw supported fixtures, first install the two mounting
screws in strap. Any remaining tapped hole may be used for the ground screw.
Chain Hung Fixtures
Loop fixture ground wire (E) (typicallycoppe r or green plastic coated) under
the head of the ground screw (S) on fixture mounting strap (M) and connect to
the loose end of the fixture ground wire directly to the ground wire of the
building system with appropriately sized twist-on connectors – see Drawing2.
Post-Mount Fixtures
Connect fixture ground wire (E) (typically copper or green plastic coated) to
power supply ground with appropriately sized twist-on connector inside post.
Cover open end of connector with silicone sealant to form a watertight seal –
see Drawing 3.
Customer Support