A D AD-4212F Production Weighing Unit Instruction Manual

June 1, 2024
A D

A D AD-4212F Production Weighing Unit

A-D-AD-4212F-Production-Weighing-Unit-PRO

Product Information

Specifications

  • Model: AD-4212F
  • Type: Production Weighing Unit
  • Width: 80 mm
  • Resolution: High resolution with electromagnetic balance sensor
  • Connectivity: Outputs digital data for direct connection to PC or PLC
  • Protection: Dustproof and waterproof (IP65 compliant)

Product Usage Instructions

Setting Up
Ensure the weighing unit is placed on a stable surface away from water and direct sunlight.

Power Connection
Use the dedicated power line provided with the unit and ensure it is not shared with other equipment. Do not operate with wet hands.

Data Connection
For connecting to a PC or PLC, use the appropriate digital data cable provided with the unit.

Maintenance
Avoid disassembling or modifying the unit. Keep rubber caps closed when not in use. Do not apply impact or drop the unit.

Safety Precautions
Refer to the warning signs and marks in the manual to ensure safe operation. Avoid using near-flammable substances or electrical devices.

FAQ

  • Q: Can I submerge the weighing unit in water for cleaning?
    A: No, submersion in water may cause malfunction. Use a damp cloth for cleaning instead.

  • Q: How do I calibrate the weighing unit?
    A: Refer to the detailed instruction manual or contact customer support for calibration procedures.

About this manual

  1. No parts of this manual may be reproduced without permission. This manual may not be copied, modified, or translated without the written permission of A&D Company, Limited.
  2. The contents of this manual are subject to change without notice.
  3. Please contact A&D if you notice any uncertainty, errors, omissions, etc. in this manual.
  4. A&D Company, Limited bears no liability for direct, indirect, special, or consequential damages due to the operation of the product, even if advised of the possibility of such damage. Furthermore, A&D assumes no liability for claims of rights from third parties. Concurrently, A&D assumes no liability whatsoever for data losses regardless of (3) above.

Safety Precautions

To prevent accidents due to inappropriate handling, this manual contains the following warning signs and marks. The meanings of these warning signs and marks are as follows.

CAUTION A potentially hazardous situation which, if not avoided, may result in personal injury or property damage.

Before use, confirm the following items for safe operation.

CAUTION

  • Never disassemble, modify or repair the weighing unit by yourself.
  • The power line used for the weighing unit should be dedicated to it and should be separate from other driving equipment.
  • Do not perform operations near the power supply with wet hands.
  • Do not use in a place where gasoline, thinner, or combustible gas may leak.
  • Use in an environment with a temperature of 5°C to 40°C and a humidity of 85%RH or less.
  • Do not poke the diaphragm or packing of the weighing unit with a sharp object.
  • The dustproof and waterproof level of the weighing unit is equivalent to IP65, and its second digit, “5”, corresponds to “having no harmful influence by receiving direct jet of water”. Washing with strong water pressure or submersion in water may cause water to enter the weighing unit and cause a malfunction.
  • When installing and using the weighing unit under conditions requiring dustproof and waterproof performance, make sure that the AC adapter plug is fully inserted into the AC adapter jack and that the signal cable is attached.
  • When not using the AC adapter or the communication cable, keep the rubber caps of the packing sections closed.
  • Do not apply impact to or drop the weighing unit.
  • When transporting the weighing unit, use the packing material in which the weighing unit was originally packed.
  • The weighing unit may affect hearing aids, pacemakers, other electrical medical devices, fire alarms, automatic doors, and other automated devices. Do not use the weighing unit nearby this kind of equipment as it may cause malfunction or accident.

Introduction

This manual is an outline of the AD-4212F (the weighing unit) and the instructions for setting up and installing the weighing unit. Refer to the A&D website for more information on operation methods, specifications, and communication methods. https://link.aandd.jp/ad4212f_en/

Features

  • The compact weighing unit has a width of only 80 mm, making it ideal for incorporating into production lines.
  • The electromagnetic balance sensor ensures high resolution and high-speed response.
  • The weighing unit outputs digital data, so it can be connected directly to a personal computer (PC) or programmable logic controller (PLC).
  • Dustproof and waterproof (IP65 compliant).
  • The WinCT-AD4212F data communication software makes it easy to check weighing values on a Windows PC. In addition, filter settings can be easily applied as needed for the operating environment, required response speed, or desired accuracy, by being graphically simulated.
  • Connect the AD-8922A or AD-8923-BCD/CC (sold separately) to manually read weighing values, re-zero, and adjust the sensitivity.
  • In addition to standard RS-232C communication, various accessories enable BCD output, comparator output, analog output, RS-485 communication, CC-Link, Modbus RTU, and Ethernet/IP.

Product Structure

A-D-AD-4212F-Production-Weighing-Unit- \(2\)

No. Name
1 Weighing pan
2 Screw for fixing pan support (Pan head screw: M5 screws x 10)
3 Pan support
4 Pan support boss
5 Main body
6 Rear of the main body
7 AC adapter jack
8 AC adapter plug
9 RS-232C output connector *1
10 Grounding terminal
11 Indicator lights
12 AC adapter *2
13 Positions of AC adapter ID labels
14 AC adapter ID labels
15 Serial number
  • The connection cable is sold separately.
  • Please confirm that the AC adapter type is correct for your local voltage and receptacle type.\

Precautions for Assembly and Installation

Fixing to the platform
For stable weighing, be sure to fix the main body to the installation platform with screws.

  • When screwing from the top: M6 screws x 4
  • When screwing from the bottom: M8 screws x 4
  • Be careful of the following when assembling and installing the unit.

CAUTION

  • Do not apply excessive rotational force or pressing force when fixing the weighing pan to the pan support boss.
  • Do not apply any pulling up or side forces to the pan support boss.
  • Do not apply impact to the weighing pan.A-D-AD-4212F-Production-Weighing-Unit- \(4\)
  • Be sure to ground the weighing unit.A-D-AD-4212F-Production-Weighing-Unit- \(5\)
  • Wire the power line and signal line to ensure distance from power supplies for driving equipment and other lines that carry large currents.

Precautions for More Accurate Weighing

For precise and accurate weighing, please take notice of the following.

CAUTION

  • Avoid impact when placing the weighing object on the weighing pan. This can lead to weighing errors and malfunctions of the weighing unit.
  • Perform sensitivity adjustment before using the weighing unit for the first time or after having moved it to another location. In addition, perform sensitivity adjustment periodically to maintain the accuracy.
  • Install the weighing unit in a location that is free of dust or vibration.
  • A suitable location for weighing is on the first (ground) floor of a building, near a wall rather than in the middle of a room because these locations are less prone to vibration.
  • We guarantee the performance of the weighing unit in a non-moving state. If the weighing unit is built into a system that is to be moved, make sure that it is level when stationary and is housed in a structure that is resistant to vibration. Avoid sudden movements, stops, or impact, and make sure that any fluctuations in weighing values due to movement have sufficiently subsided before acquiring data.
  • The weighing unit is dustproof and waterproof in compliance with IP65. However, clean and control the area around the pan when measuring powders, liquids, metal fragments, etc.
  • The best operating conditions are a stable environment of 20 °C ± 2 °C and 45% to 60% RH. To minimize temperature fluctuations, install the weighing unit where it is not exposed to direct sunlight.
  • Do not install in a location where it will be exposed to airflow from air conditioners or other equipment. Airflow and temperature changes may cause errors in the weighing value.
  • Temperature difference between the ambient temperature and the weighing object (including the tare) may result in weighing errors due to convection currents around the weighing object or temperature changes in the weighing unit. Take measures as necessary, such as insulating with a dedicated jig pan.
  • Airflow may cause the weighing value to become unstable. Avoid installing the weighing unit near doorways or corridors. Also, do not use compressed air to move the object to be weighed to the weighing pan.
  • Install the weighing unit away from equipment that produces magnetic fields.
  • The electrostatic charge (static electricity) of the object to be weighed or the nearby jig may cause fluctuations in the weighing value. Insulators such as plastic, glass, etc. are easily charged with static electricity in environments with humidity of 45%RH or less.
  • Install on a level platform. If levelling is not possible, be sure to perform sensitivity adjustment in that installation condition.
  • When fabricating a dedicated weighing pan, make sure that the surface area is as small as possible to reduce fluctuations in weighing values due to drafts, and that the material used is rigid and conductive to prevent static electricity from charging.
  • Be sure to connect the AC adapter connected to the power supply to warm up the weighing unit before use for at least half an hour.
  • When not weighing at the centre of the weighing pan, install the weighing unit so that the total moment of the jig and the object to be weighed is less than the specified value. (For details, refer to the instruction manual on A&D website.)
  • To reduce measurement error, use the command to perform a zero reset before every weighing, or calculate the weighing value by the difference before and after weighing.

Connection and Weighing Value Confirmation (RS-232C)

  • **How to connect and disconnect the cable***

  • The connection cable is sold separately.A-D-AD-4212F-Production-Weighing-Unit- \(7\)

  • Disconnecting the cable
    Slide the connector sleeve (the part marked with an arrow) to unlock the connector, and then pull out the connector.A-D-AD-4212F-Production-Weighing-
Unit- \(8\)

  • Cable pin assignments
    (when using the accessory cable AX-KO3590-1000)A-D-AD-4212F-Production-
Weighing-Unit- \(9\)
    With the accessory cable AX-KO3590-1000** No.| Signal name| Direction| Description**
    ---|---|---|---
    1| Vs| –| Internally used, power supply for external equipment: GND
    2| TXD| Output| Transmit data
    3| RXD| Input| Receive data
    4| –| –| N.C.
    5| SG| –| Signal ground
    6| DSR| Output| Data set ready
    7| RTS| Input| Request to send
    8| CTS| Output| Clear to send
    9| Va| –| Internally used, power supply for external equipment: Output terminal

RS-232C factory settings****

Item Setting
Baud rate 2400 bps
Data bits 7 bits
Parity EVEN
Stop bit 1 bit
Codes used ASCII
Data format A&D standard format
Data output mode Continuous output mode
  • Output data (RS-232C)A-D-AD-4212F-Production-Weighing-Unit- \(10\)

  • How to check with an AD-8922A or AD-8923CC/BCD

    • A-D-AD-4212F-Production-Weighing-Unit- \(11\)
    • Settings
      If all the connected devices are set to the factory settings, the weighing value will be displayed only by connecting the cable and power supply. If the settings have been changed, refer to details in each instruction manual, match the RS-232C settings of the connected devices, and set the data output of the weighing unit to continuous output mode.
  • How to check with a personal computer (PC)

    • A-D-AD-4212F-Production-Weighing-Unit- \(12\)
    • Settings
    • Download the WinCT-AD4212F installer from our website.
    • Install WinCT-AD4212F on your PC. Refer to the WinCT-AD4212F Readme for the installation method.
    • Set the COM port of WinCT-AD4212F on your PC and press the START button. The weighing value will be displayed on the PC screen. If the weighing value is not displayed, make sure the baud rate settings of the weighing unit and the PC match and that the data output mode of the weighing unit is set to continuous output.
  • How to connect with a PLC.

    • A-D-AD-4212F-Production-Weighing-Unit- \(13\)
    • Settings
      Adjust settings according to your PLC.
      For RS-232C settings and the data format of the weighing unit, refer to “6. Connection and Weighing Value Confirmation (RS-232C)”.
      Continuous output mode is set as the factory setting and weighing data is output continuously from the weighing unit. To change the output mode, refer to “7. Frequently Used Commands (for RS-232C)”.

Frequently Used Commands (for RS-232C)

By sending the following commands externally via RS-232C, the corresponding operation can be performed. Send commands from your PLC or PC.

Command Description (Function)
C Set temporarily to command mode. The weighing value is output upon data

request from the host. The setting is canceled when the power is cut.
Q| Immediately request the weighing value. (The weighing value is output regardless of whether it is stable or unstable. Note that continuous output mode must be disabled.)
S| Request the weighing value after stabilization. (The weighing value is output after it becomes stable. Note that continuous output mode must be disabled.)
SIR| Set temporarily to continuous output mode. Weighing values are output continuously. The setting is canceled when the power is removed. (C command to stop continuous output.)
PR:00| Set to command mode. A data request from the host outputs the weighing value. The setting is retained even after power is cut.
PR:03| Set to continuous output mode. Weighing values are output continuously. The setting is retained even after power is cut.
?PRT| Check the data output mode setting. For command mode, the response is Pr,00. For continuous output mode, the response is Pr,03. Temporary settings by the C command or SIR command are not reflected in this response.
R| Set the weighing value to zero (tare).
CAL| Enter calibration mode.
U| Switch the weighing speed (response characteristics).
SMP| Switch the readability.

How to Use RS-485

For the weighing unit, use the accessory cables AX-KO7522-500 (5 m), AX- KO7622-200 (2 m), and the RS-485 interface (AD4212F-29) to enable communication via the RS-485 interface. With RS-485, multiple units can be connected in a daisy-chain connection. Setting individual device addresses allows communication with each unit by adding the device addresses to the commands to be sent and received. The AX-KO7522-500 can supply power to the weighing unit.

  • Connection diagramA-D-AD-4212F-Production-Weighing-Unit- \(14\)
  • Cable wiring (with the accessory cable AX-KO7522-500)A-D-AD-4212F-Production-Weighing-Unit- \(15\)

When using the accessory cable AX-KO7522-500

Lead wire Signal name Direction Description
Yellow DC+ Input / Output Power supply (12 V DC)*
Yellow / White GND Input / Output Power supply (0 V)
Blue DATA+ Input / Output RS-485 signal line
Blue / White DATA- Input / Output RS-485 signal line
Black FG Frame ground

Supplies power to the weighing unit. 12 V is output when power is supplied directly to the weighing unit using the included AC adapter. When supplying power to the weighing unit, make sure that its voltage is correct. Once power is supplied, please do not let the terminals of discrete wire touch one another or anything around them, or do not touch them by hand.

RS-485 factory settings

Item Setting
Baud rate 2400 bps
Data bits 7 bits
Parity EVEN
Stop bit 1 bit
Codes used ASCII
Device address 0
Termination resistor None (Open)
Data format A&D standard format
Data output mode Command mode
  • How to set device address and termination resistor Remove the screws (at the four corners) to remove the rear panel.A-D-AD-4212F-Production-Weighing-Unit- \(16\)

  • Output data (RS-485)
    Weighing data with “@” at the beginning ( represents the set device address) is output. (Unlike RS-232C, data for display unit control is not output.)A-D-AD-4212F-Production-Weighing-Unit- \(17\)

  • Transmission data (RS-485)
    RS-232C commands can be used with a device address added to the beginning. The unit with the matching device address will respond.A-D-AD-4212F-Production-
Weighing-Unit- \(18\)

Specifications

Weighing capacity AD-4212F- 6203D AD-4212F- 10202 AD-4212F- 22001
510 g / 6200 g 10200 g 22000 g
Readability 0.001 g / 0.01 g 0.01 g 0.1 g
Repeatability 0.002 g / 0.01 g 0.01 g 0.1 g
Stabilization time in seconds*1 With 0.001 g

readability

| 1.3 sec*2| 0 to

300 g

| 0.5

sec

| 0 to

300 g

| 0.5

sec

With 0.01 g readability| 1.0 sec| 300 to

10200 g

| 1.0

sec

| 300 to

22000 g

| 1.0

sec

Data refresh rate| 100 times / second*3
Power supply (AC adapter)| Please confirm that the AC adapter type is correct for your local voltage and receptacle type.
Power consumption| Approx. 30 VA (including the AC adapter)
Current consumption| 12 V DC Approx. 0.3 A (excluding the adapter and optional accessories)
Main body weight| Approx. 3.2 kg
Dustproof/waterproof| IP65 compliant

  • When the stability bandwidth is set to ±3 digits and FAST is selected for the weighing speed (response characteristics) in a good environment.
  • When the precision range is used.
  • The baud rate must be set to 19200 bps or higher.

External dimensions

A-D-AD-4212F-Production-Weighing-Unit- \(19\)

*The screw holes to secure the exclusive weighing pan created by customers.

Indicator Lights

The two indicator lights on the top of the weighing unit indicate the following states.

Color When Description
Green Lit Power is on.
Blinking Blinks correspond to the baud rate setting * (Only when power supply

begins.)
Red| Lit| Non-weighing values (e.g., rezero, sensitivity adjustment in progress, etc.) are output.
Blinking| Warning that impact has been applied to the weighing unit

  • See below for the number of blinks and the corresponding baud rate setting, and how to count the number of blinks.
Number of blinks Baud rate
1 600 bps
2 1200 bps
3 2400 bps
4 4800 bps
5 9600 bps
6 19200 bps
7 28800 bps
8 38400 bps
9 115200 bps

E.g.) Number of blinks: 3 (2400 bps)A-D-AD-4212F-Production-Weighing-
Unit- \(20\)

Accessories

The connection cable is not included. Please purchase the accessory cables that are suitable for your needs.

AX-KO3590-200 RS-232C cable                                     2 m
AX-KO3590-500 RS-232C cable                                     5 m
AX-KO3590-1000 RS-232C cable                                     10 m
AX-KO7522-500 RS-485 cable (discrete wire)                 5 m
AX-KO7622-200 RS-485 cable (for daisy chain)              2 m
AX-USB-9P-EX USB converter cable set
AD4212F-29 RS-485 interface (for daisy chain)

Refer to the detailed instruction manual on the product page: https://link.aandd.jp/ad4212f_en/

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>