INTRODUCTION

  • The controller is a mini single-door controller panel, that can work with any Wiegand 26~44, 56, 58bits output reader, it uses an Atmel microcontroller to assure stable performance and is equipped with an infrared remote control for easy operation.
  • The device supports 1,000 users, all user data can be transferred.

Two versions are available:

  • Standalone Controller
  • WiFi Controller with Tuya APP

FEATURES

Controller:

  • 12V DC power input
  • One relay, 1000 users
  • Multi-access modes: Card, Card or PIN, and multi Cards/PINs
  • Wiegand 26~44, 56, 58bits input
  • Can connect with any reader with Wiegand 26~44, 56, 58bits output
  • Can connect with any keypad reader with 4bits, 8bits (ASCIl), or 10bits Virtual number output
  • User data can be transferred (except fingerprint users)
  • 2 devices can be interlocked for 2 doors
  • Can connect with external alarm and door contact
  • Support Master Card and Authorized User

APP Feature: (Only available for WiFi version)

  • 500 APP users
  • iOS and Android available
  • Add / Delete users by APP (Only available for card users)
  • Can set Time Restrictions for users
  • Temporary Code (One-time Or Period Code)
  • Support checking Opening Record
  • Remotely Access (Support 3G/4G/5G)
  • Multiple Access Modes: Smartphone, Card, PIN, Fingerprint
  • Doorbell Call Notice (Support External Door Bell)

Specifications

tuya-sboard-III-WIFI-Smart-WiFi-Access-Control-Card-FIG-1
\(1\)tuya-sboard-III-WIFI-Smart-WiFi-
Access-Control-Card-FIG-1 \(2\)

Carton Inventory

tuya-sboard-III-WIFI-Smart-WiFi-Access-Control-Card-FIG-1
\(3\)

INSTALLATION

tuya-sboard-III-WIFI-Smart-WiFi-Access-Control-Card-FIG-1
\(5\)

Sound and Light Indication

tuya-sboard-III-WIFI-Smart-WiFi-Access-Control-Card-FIG-1
\(13\)

Connection Diagram

Note: For the WiFi version, it’s necessary to connect a ‘Door Contact’ to monitor the door status in the APP.

tuya-sboard-III-WIFI-Smart-WiFi-Access-Control-Card-FIG-1
\(6\)

When Use NO/NC/COM Dry Contact Output

tuya-sboard-III-WIFI-Smart-WiFi-Access-Control-Card-FIG-1
\(7\)

Remark: The power supply’s voltage must be the same as the lock’s supply voltage, or else, the lock will not work properly or be damaged.

PROGRAMMING

Programming will vary depending on access configuration. Follow the instructions according to your access configuration.
Notes:

  • Remote Control: Please use the Infrared Remote Control to program the Controller, “IR” on the Controller is the infrared receiving window, please direct the Remote Control to it. Cards can be read on the RFID/Keypad/Fingerprint readers only. PINs can be input/added on either the remote control or the external Keypad Reader, except when the Keypad Reader is 10 digits virtual card number output, the PIN(s) can only be input/added through the Keypad Reader.
  • User ID number: Assign a user ID to the user to track it.
  • The Common user ID: 0~986
  • Authorized User ID: 987
  • Panic User ID: 988~989
  • Visitor User ID: 990~999
  • IMPORTANT: User IDs do not have to be processed with any leading zeros. Recording of User ID is critical.
  • PIN: Can be any 4~6 digits

Enter and Exit Program Mode

Programming Step Keystroke Combination
1. Enter Program Mode ( M aste r Code)#

(factory default is 123456)

2. Exit Program Made|

Set Master Code

Programming Step Keystroke Combination
1. Enter Program Mode (Maste r Code)#
2. Update Master Code 0 (New M as t er Code)# **(Repeat

Ne w**

Master Code)# (Master code is any 6 digits)

3. Exit Program Mode|

Add Common Users

  • PIN/Card user ID: 0~986;
  • PIN length: 4~6 digits

tuya-sboard-III-WIFI-Smart-WiFi-Access-Control-Card-FIG-1
\(8\)

Tips for PIN Security (Only valid for 6 digits PIN): For higher security we allow you to hide your correct PIN with other numbers up to a max of 9 digits.

  • Example PIN 123434
  • You could use *(123434) or (123434) (” can be any numbers from 0~9)

The device is connected to a Fingerprint Reader:

For example: Connect SF1 as the fingerprint reader to the device, and two steps to enrol the valid fingerprint.

  1. Add the Fingerprint (A) on SF1
  2. Add the same Fingerprint (A) on the device as below:

tuya-sboard-III-WIFI-Smart-WiFi-Access-Control-Card-FIG-1
\(9\)

NOTE: Fingerprint Adding in the APP is not valid for the WiFi version.
Add Authorized User

(User ID number is 987; PIN length: 4~6 digits)

Programming Step Keystroke Combination
1. Enter Program Mode ( Master Code)#

2. Add Card

OR

2. Add PIN

| 1 (User ID)# (Read Card / lnpu1 811 O Dlgtts

Card number)#

1 (User ID)# (P IN) #

3. Enter Program Mode|

Remark: Authorized users can use a card or PIN, read the Authorized Card or input the Authorized PIN, then all valid users can’t access; read the Authorized Card or input the Authorized PIN again, then all valid users can access again.

Add Panic Users
(User ID number is 988~989; PIN length: 4~6 digits)

Programming Step Keystroke Combination
1. Enter Program Mode ‘ (Master Code)#

2. Add Card

OR

2Add PIN

| 1 (User ID)# (Road Card/ Input 8110 Digits Card number #

1 (User ID)# (P IN) #

3. Enter Program Mode|

Add Visitor Users
(User ID number is 990~999; PIN length: 4~6 digits) There are 10 groups of Visitor PIN/card available, the users can be specified up to 10 times of usage, after a certain number of times,i.e. 5 times, the PIN/card becomes invalid automatically.

Programming Step Keystroke Combination
1. Enter Program Mode (Master Code)#

2. Add Card

OR

2. Add PIN

| 1 (User ID)# (0-9) #(Read Card / Input 811 0

Digits Card number)#

1 (User ID)# (0-9) #(PIN)#

(0-9 means times of usage, 0=10 times)

3. Enter Program Mode|

Delete Users

Programming Step Keystroke Combination
1. Enter Program Mode • (Master Code)#

2. Delete User – By card/PIN

OR

2. Delete the User By ID number

OR

2. Delete User – By Card number

OR

2Delete ALL Users

| 2 (Read Card)/ (Input PIN) #

2 (User ID)#

2 (Input 8/10 Digits Card number) # 2 (Mas t e r Code)#

3. Enter Program Mode|

Set Relay Configuration

The relay configuration sets the behaviour of the output relay on activation.

Programming Step Keystroke Combination
1. Enter Program Mode ,. (Master Code)#

2. Pulse Mode

OR

2. Toggle Made

| 3 (1-99) #(factory default)

The relay lime is 1-99 seconds. (Default is 5 seconds)

30#

Sets the relay to ON/OFF Toggle mode

3. Enter Program Mode|

Set Access Mode
For Multi-user access mode, the interval time of reading can not exceed 5 seconds, or else, the device will exit to standby automatically.

Programming Step Keystroke Combination
1. Enter Program Mode ,.. (Master Code)#
2.Car’dAccess 40 #
OR
2. PIN Access 41 #
OR
2. Canal 0 < PIN Access 4 3 #(factory default)
OR
2. Multi-User Access 4 3 ( 2 -9 ) #
3. Enter Program Mode (Only after 2-9 valid users, the door can be opened)
 
 

Set Strike-out Alarm

  • The strike-out alarm will engage after 10 failed entry attempts (Factory is OFF).
  • It can be set to deny access for 10 minutes after engaging or disengage only after entering a valid card/PIN or Master code/card.
Programming Step Keystroke Combina1ion
1. Enter Program Mode ‘(Master Coda )#

2. Slrike-Out OFF

OR

| 6 0 # (factory default)|

2. Strike-Out ON OR| 61 #
2.Strike-Out ON(Alarm) Set Al9rm Time| 62# 5 ( 0-3) # (factory default is 1 minute)

Enter Master Code# or Master Card or valid User card/PIN to silence)

3. Enter Program Mode|

Set Door Open Detection
(Users will be suggested to connect a Door Contact on the device. Otherwise, in the mobile APP, the door status will be shown ‘ON’ all the time. Or Connect “D_IN” and “GND”)

tuya-sboard-III-WIFI-Smart-WiFi-Access-Control-Card-FIG-1
\(10\)

The function of Set Alarm Time also applies to anti-tamper alarms.

Set Audible and Visual Response

Programming Step Keystroke Combination
1. Enter Program Mode ,.. (Master Code)#
2. Disable Sound 70#
Enable Sound 7 1 # (factory default)
DR
2. LED Always OFF 72#
LED Always ON 7 3 # (factory default)
3. Enter Program Mode

Set Wiegand Format

Programming Step| Keystroke Combination|
---|---|---
1. Enter Program Mode| •  (Master Code)#
2.| Wiegand Formal Auto-kJent| fact| on| 6 0 # (factory de fa ult)

8 (26-4-4, 56, 58 ) #

OR

2.Specified Wiegand Formal

3. Enter Program Mode|

Master Card Usage

Using Master Card to add and delete users

Add Card/P| IN Users| 1. Input (Master Card)

2. Input {Card) or ( PIN #)

Repeat step one for additional users

3. Input (Master Card) again

Delete Card/PIN Users| 1. Input (Master Card Twice within 5s)

2. Input (Ca r d) or (P IN #)

Repeat step one for additional users

3. Input (Master Card) again

User Operation & Reset to Factory Default

  • Open the door: Read a valid user card or input a valid user PIN
  • Remove Alarm: Input Master Code # or read Master Card or valid user card / PIN or valid user card / PIN
  • To reset to factory default & Add Master Cards: power off, press the Exit Button (or connect “OPEN” and “GND” to be short circuit), hold it and power on, there will be two beeps, then release the exit button (or disconnect “OPEN” and “GND”),the LED light turns into yellow, then read any 125KHz EM card or HID cards or 13.56MHz Mifare card, the LED will turn into red, means reset to factory default successfully. Of the card reading, it is the Master Card.

Remarks:

  1. The type of the Master Card is according to the external reader.
    • For example: if the external reader is a 125KHz HID reader, then the Master Card must be a 125KHz HID card.
  2. If no Master Card is added, must press the Exit Button for at least 5 seconds before release. (This will make the previously registered Master Card invalid)
  3. Reset to factory default, the user’s information is still retained.

Advanced Application

Collection Card Mode
After this mode is turned on, all the cards can open the lock, and at the same time, all cards are added to the device.

Programming Step| Keystroke Combination|
---|---|---
1. Enter Program Made| • ( Mas1 er Code) #
2. Collect| ion Card Mode OFF| 9 2 # (factory default)

93#

DR

2. Collection Card Mode ON

3. Enter Program Mode|

User Information Transfer (Valid for Card/PIN Users)

  • ( Please note: only users added by the device can be transferred and valid for opening; users added by the mobile APP can also be transferred, but are unable to open the lock)
  • The enrolled user can be transferred from a “Master” unit to a “Slave” unit.
  • The Master code must be the same in the “Master” and the “Slave” units.

Remarks:

  • The Master units and Slave units must be the same series of devices
  • The Master Code of the Master unit and the Slave unit must be set to the same.
  • If the Slave unit is already with the users enrolled, it will be covered after transferring.
  • or full 986 users enrolled, the transfer takes about 30 seconds.

Set Transferring on Master Unit:

Programming Step| Keystroke Combination|
---|---|---
t. Enter Program Mode| • (Master Code)#
2. Set Trans| ferr| ng| 98#
Within 30 seconds, the Green LED shines, and after one beep, the LED will turn RED, which means the user’s · Information has been transferred successfully.
3. Enler Program Mode|

Interlock
Let’s name the two devices “A “and “B” for two doors “f” and “2”

  • Step 1: Enroll the users on Device A, then transfer the users’ information to Device B through the “User Information Transfer” function
  • Step 2: Set both of the two devices (A and B) to Interlock function
Programming Step Keystroke Combination
1. Enter Progr am Mode

2. Interlock-OFF

OR

2. lnter1ock-ON

| 9 0 # (f| factory default)

9 1 #

3.| Enter Program Mode|

If interlock, when and only door 2 is closed, the user can read the valid users on Reader A, and door 1 will open; then when and only door 1 is closed, read valid users on Reader B, and door 2 will open.