Tuya GSM and WIFI Network Alarm System User Manual
- October 30, 2023
- Tuya
Table of Contents
GSM &WIFI Network Alarm System
User Manual
Wi-Fi+GSM+GPRS
Overall state
Explanation
For all the issues stated in this manual:
The icon only valid for the corresponding model host which is configured with
the WIFI module.
The icon is only valid for user who has applied alarm service in the local
network alarm operation service center.
Features
» 4.3-inch IPS color display, full capacitive touch screen operation, simple
style man-machine interface and menu guidance design
» The main interface status bar, date and time clock display, host status at a
glance
» Built-in powerful performance CPU master based on 32-bit Cortex-M3 core
» Based on the operating system with multitasking design, with a great user
operation experience.
» WIFI/IGSM/GPRS network alarm system, and support APP push/SMS/voice
monitoring/center network etc. multi-channel alarm ways, to ensure the alarm
performance stable and reliable.
» Support SMS arm/Disarm and parameters setting, support voice arm/Disarm.
» Up to 99 storage locations for the learning of remotes , RFID and wireless
detectors. 4 wired defense zone
» Support many defense zones name such as of the gate, SOS, bedroom, window,
balcony, perimeter, smoke, gas, carbon monoxide, water leaking, etc.
» Support the main power failure, backup battery power shortage, tamper alarm
and other extended alarm; Support detector low battery alert & tamper alarm
function.
» support Door open alert.
» Support many defense zone types setting such as of entry/exit zone, indoor
zone, perimeter zone, 24-hour zone, doorbell, etc.
» Up to 5 groups preset alarm phone numbers, SMS on/off and voice on/off can
be set respectively.
» External wired alarm connectors: 1 channel external wireless siren, 8
channel alarm linked wireless intelligent socket.
» APP or host can control several socket, so control the home electrical
appliances.
» Can store and query several daily operation records and alarm records.
» GSM network automatic timing, to ensure the clock keep accurately all the
time
» Support multi-language menu display, voice prompts and alarm SMS settings.
» Can record 20 seconds message and alarm voice.
» Telephone function, support 5 groups re-dial number.
» Excellent APP operation feeling and user interface, get the device working
status anytime.
» Arm/disarm, host alarm to mobile app.
» Support APP arm/disarm remotely, parameter setting, Parts management and
intelligent socket control.
Friendly APP operating experience and user interface, obtain the latest
working state of the device at any time.
» User arm and disarm, host alarm push to APP.
Support APP arm and disarm remotely.
GPRS real-time networking online, access to the latest working state of the equipment at any time. Automatically alarm if offline.
» Reserved remote GPRS TCP / UDP protocol channel, compatible with multiple alarm center networking protocol to facilitate network alarm.
Center remote control.
Daily Operation Nouns
ARM: set the security task (Anti-burglar), make the host into alert state, also known as Arming, Alert or Booting.
»Stay Arm: When users at home, only need to alert entrances or perimeter.
»Disarm: cancel the safety task (Anti-burglar), also known as removing alarm or shutdown.
»Trigger: In Arm state, detector detects someone or door is opened, it will trigger the detectors and make alarms.
»Exit delay: in the ARM state, to avoid making alarms while the users passing, need to delay the alarm time.
»Entry delay: while the users come back and pass the Arm zones, host will not make alarming immediately , need some time users passing by; the host will make alarms if time out beyond the Disarm.
Alarm: while the host have the alarm assignment, it will cause the strobe alarm locally, then send the SMS alarm to the mobile defaulted, dial the mobile defaulted, push the alarm to the mobile app and send the message to the networking alarm center etc.
APPEARANCE AND ACCESSORIES
Power On/Off
Function | Method |
---|---|
Power On | Push this button, it will show “welcome “means power on successfully |
Power Off | Push this button for 3 seconds till the screen become black, means |
power off successfully
SOS Button
Push this button when emergency, it will cause the strobe alarm locally, then
send the SMS alarm to the mobile defaulted, dial the mobile defaulted, pushed
alarm to the mobile app and send the message to the networking alarm center
etc.
SOS button backlight
Back ground light | Status |
---|---|
Circulate twinkle | Alarm |
Breathing twinkle | Alarm |
Normally on | Disarm |
Navigating Menus
Main interface function and button description
Top status bar
|
1
|
4
| GSM Status induction
| | No SIM card or wrong inserting
---|---|---|---|---|---
| GPRS networking status indication|
| GSM networking strength indication
No networking if gray color, 1~5 means the strength level
5
| WIFL wireless| | 1~4 means the wifi strength level Gray color means no
wifi|
| Device already connected with the cloud, White dot at the right bottom
corner means the binding mobile is online
6
| GSM
assign status| | SMS sending
| Telephone/mobile dialing
7
| Keyboard Lock| | Keyboard status Sseconds countdown before locked
8
| Power status| | Man power supply
| Spare power supply,0~3 shows the power capacity
9
| Clock|
00:04
| Current time
Main status zone
|
2
| |
| Current date and week
11
| Dial button| | Push and dial the telephone number
16
| Menu button| | Push and enter into the menu setting
12
| Am button| | Push and enter into the arm system
13
| Socket button| | Push and control the intelligent socket
17
| stay Am button|| | Push and enter into stay arm
18
| Disarm button| | Push and enter into disarm
14
| Arm/Disarm Log button || Push and searching the arm/disarm history
18
| Arm/Disarm status|
| Am status
| Stay arm status
| Disarm status
15
| Alarm Log| Push can searching the alarm history
Alarm status| | No alarm
| Alarm status will show the zone number f the zone alarm
Bottom status bar
|
3
|
00:04
| Current time
” Please exit” Countdown bar| Exit the delay stats
Enter into the countdown status when arm finished
Wil get 10 get into when the countdown finished
” Please disarm” Countdown bar| Enter into the delay status
Need to be the count down status when get to the arm
status, if no disarm, device will be triggered and alarm
“Synchronizing” Countdown bar| Leaming accessory state
Please trigger the parts before count down
Screen close button| | Push and enter into black screen
Menu Structure
Main menu| System Setting| Delay Setting| Exit Delay| Set the exit delay
value, please refer to the daily operation words
---|---|---|---|---
Unitseconds;scope:0-999 ; default:40 seconds
Enter Delay| Set the enter delay value, please refer to the daily operation
words
Unit:seconds;scope;0— 999 ; default: 30 second
Siren Duration| Set the siren duration time while alarming
Unit:minutes;scope:0— 999 ;default:3 minutes
Function Setting| Arm Beep| Set the arm beep for external siren while
arm/disarm
scope:on/off, default:off
Alarm Beep| Set the siren notice for internal/external siren while arm/disarm
scope:on/off, default:off
Arm/Disarm SMS| SMS notice while setting the Arm/disarm
scope:yes/no, default:no
Keypad Lock| Keypad locked setting
scope:yes/no, default:no
Keyboard Backlight| Keyboard backlight setting
scope:on/off, default:off
Keypad Tone| Keypad Tone setting
scope:on/off, default:off
Delay Tick| Delay Tick notice while in/out setting
scope:on/off, default:on
Openning Alert| Alert displays when ARM with the door/window open
Option: ON or OFF; Default: ON)
Voice Prompts| Voice prompts for keypad operation
Option: ON or OFF; Default: ON)
| assistant switch| Low power alert, indoor environment, SOS
Scope: on/off, default on
Password Setting| System Password| System password setting
Scope:0000-9999;scope:6666
User Password| User password setting
Scope:0000-9999;default:1234
Language Setting| EAAnviKO| Panel in Greek language
flincli5C| Host Language: Simplified Chinese
English| Host Language: English
Deutsch| Host Language: Deutsch
PYCCKV1I21| Host Language: Russian
Espanol| Host Language: Spanish
Polski| Host Language: Polish
Italiano| Host Language: Italian
Francais| Host Language:French
Portugues| Host Language: Portuguese
Initialization| System Initialization, Function & describe as: System
Initialization
Mainmen| Phone Management| 1st Phone| Group 1 alarm phone number & dial
Switch,SMS switch| See as: Phone Number setting
---|---|---|---|---
2st Phone| Group 2 alarm phone number & dial Switch,SMS switch
3st Phone| Group 3 alarm phone number & dial Switch,SMS switch
4st Phone| Group 4 alarm phone number & dial Switch,SMS switch
5st Phone| Group 5 alarm phone number & dial Switch,SMS switch
Log Searching| Alarm Log| Alarm log & Event record
Arm Log| Alarm/disarm log searching
Accessories| Remote Controller| Add/delete remote controller| See as:
Remote controller add/ delete
Detectors| Add/delete wireless detectors| See as:
Wireless detector add/ delete
RFID| Add/delete RFID cards| See as:RFID card add/ delete
Siren Learn| External wireless siren pairing| See as:
External Wireless Siren matching
Alarm Socket| Alarm linkage intelligent socket Airlink| See as
Wireless Alarm Linkage
Socket Timer| Intelligent socket timer on/off setting| See Intelligent Home
Reader| Read the data code sent by terminal accessories| See
Wired Defense Zone| Alarm information for configuring wired defense zones| See
Wi-FiSetting| Airlink| Host gets into WIFI wireless networking airlink status
(need to match mobile APP)| See as
Mobile APP with the host airlink & unbind
Unbind| Unbind the mobile app with the host
MAC/IP| Get the Wi-Fi MAC&IP address
Hotspot Configuration| Host gets into WIFI wireless network airlink status
(need to match mobile APP)
Record| Record/Playback| Record and playback| See as: Record management
Play| Play the current record
Delete| Delete the current record
Duration| Set record duration| Dscope:1-20efault:20 second;
Timer| Arm Timer| Arm timer time & on/off setting| See as:
Arm / disarm Timer
Disarm Timer| Disarm timer time & on/off setting
Zone&Sync| Set the time difference between the local time with the Greenwich
time
Date & Time| Host time manual setting|
Wi-Fi Sync| Set if the time sync with the Wi-Fi| Scope: on/off; default: on
2G/4G Sync| Set if the time sync with the 2G/4G network| Scope: on/off;
default: on
Version| Search the Wi-Fi firmware, MAC address, 2G/4G firmware, 2G/4G module
IMEI number, host firmware, host serial number
Note:
- Keyboard lock open: at the main interface, no pushing within 30 seconds or push directly, host will enter locked status. After locked, the user must enter a password to unlock before he can operate the host.
- keyboard background light closed: at the main interface, no pushing within 30 seconds or push directly, host background light will be closed to save the power.
After selecting one language, the operation notice, display, SMS message will switch to the same language, host will restart while finished.
First time Use
Start operation
- Insert Card: insert a standard micro SIM card into the card slot as illustrated below
- Power On: plug in the power adapter through the USB 5V interface.
- Host On: in the off state, long press the power button till the “Welcome’ displays on the screen. The host is on.
- Host Off: in the off state, long press the power button till the screen black. The host is off.
System initialization
Main menu-System Setting-Initialization. All parameters, languages and time
zones set by users will be back to factory default setting, all remote
controls, detectors, RFID tags and records will be deleted, after
initialization.
Networking IP deleted, the host is in GPRS offline statue. You’ll need to send
SMS to reset IP for the host to go back online.
Caution! only advised to do this when you forget operation password, host
malfunction, parameters setting mistakes, unidentified detectors, remote
controls or RFID tags learned. Initialization doesn’t work under Keypad Lock.
Smart Life APP Quick Use Guide
APP Download
“Smart Life” APP has been released to the major global application stores, you
can download it by searching “Smart Life” the application store or by scanning
the QR code below.
IOS App: Please search” Smart Life” in Apple store to download
Note: 1OS app has no QR code, have to download it in Apple store by
searching Smart Life
Android App:Please search” Smart Life” in Google Play to download or scan the
following QR code to downlod.
Notes:
- Mainland China users can scan the Official Website Version and download it.
- Non-Mainland China users just scan the Google Play Version
- Both the Official Website Version and the Google Play Version are the same app, just only the download channels different.
|
---|---
**<http://e.tuya.com/smartlife>**
|
**<https://play.google.com/store/apps/details?id=com.tuya.smartlife>**
Account Registration and Login
When using a mobile phone number to register and log in, you need to select
the corresponding country/region when registering and logging in, and replace
the “+xx” country code at the beginning of the mobile phone number account
with the code corresponding to the country to which the mobile phone number
belongs.
Device Network Configuration
The default network configuration mode is Airlink Configure, and it can also
be switched to “SoftAP Configure” by “Other Mode”. When configuring the
network for the device, the mobile phone needs to be connected to the Wifi
network that the device needs to configure (only 2.4GHz WIFl network is
supported when configuring the network for the device)
Airlink Configure
-Use Smart Life APP to click the “+”in the upper right corner of the main interface -> Next select“Security & Sen ->Next select Alarm “Wi-Fi” and click OK to enter the Wi-Fi interface. -Enter the correct WiFi password, click “Next”, enter the device configuration
preparation interface, and wait for the de to enter the Airlink Configure
mode. -According to the instructions, the device enters the WIFI Airlink
Configure mode. -Back to the “Smart Life APP”, click “Continue” to configure
the network, and wait patiently for the network configuratio be completed.
SoftAP Configure
-Use Smart Life APP to click the “+”in the upper right corner of the main interface -> Next select “Security & Sensor ” -> Next select Alarm“Wi-Fi” -> Next select “Other mode”-> Next Select “SoftAp Configure” and click OK to enter Wi-Fi interface.
-Enter the correct WiFi password,click“Next”, enter the device configuration preparation interface, and wait for the device to enter the SoftAP mode. -According to the instructions, the device enters the WIFI SoftAP mode.
-Back to the“Smart Life APP”, click“Continue” to configure the network, and wait patiently for the network configuration to be completed.
Menu Operation
This product is designed with capacity touch screen, utilizing current sensing
of human body to function
For features not listed in this chapter, refer to the descriptions in the
diagram above.
Function described in this part: include the phone number setting, remote
controller add/delete, wireless detector add/delete and the external wireless
siren matching can be set by mobile app.(only with )
Adding Alarm Phone Number
The host can be set to communicate with up to 5 phone numbers, dialing and SMS
feature of which can be enabled/disabled separately. To set #1 phone number,
for instance:
- Keypad operation: Main Menu →Phone →1st Phone, press to enter setting interface. You can input the alarm phone number (max.18 digits).
- Move to and press to set it on/off. When you set it on, the host will call this phone number when alarm happens.
- Move to and press .to set it on/off. When you set it on, the host will send SMS to this phone number when alarm happens.
- Press to confirm Setting.
Adding/Deleting Remote Controller
Push: Main menu→ Parts→ Remote controller, enter the interface for remote
controller setting.
Push for page down, it will show all the Synchronized remote controller
Adding a new remote controller
Press to add remote, 20-second countdown starts.
Press any buttons to send wireless signal to the host.
When ‘Learning OK’ displays, the remote is added successfully.
When ‘Device code has been learned’ displays, it means the remote control
was added already or it has the same wireless code as the other wireless
detector added. Please change to a new remote.
Delete
choose the remote controller listed, press the related numbers to delete the
related remote controller, ·choose “0” to delete all the remote controller..
Match code with/delete wireless detectors
- Press: Main→menu→ Parts→ Detector,enter into the detector setting interface.
- Press page down, it will list all the Synced wireless detectors.
Sync the new wireless detectors
- Press √ ,host get into the”Set Name/Mode/Number”interface
- Press ,choose the zone name for the none Sync wireless detectors.
Press ,choose the none Sync wireless detectors. (stay arm active/ out arm active/24 hours active/ off/ doorbell silent 24 hours/ stay arm available (no delay) out arm available (no delay) Choose “Stay Arm ACTIVE”, after the arm or stay arm setting, the detectors in this zone will alarm while be triggered. Front Door 、 Window 、 Balcony 、 Perimeter use this kind of detectors.
Choose“ Out Arm Active”, after the stay arm setting, the detectors in this zones will not alarm while be triggered. Living Room 、 Bedroom and other internal place use this kind of detectors. Choose ”24 Hours Active”, it will alarm while be triggered anytime, SOS Panic、Smoke/Fire、Gas、CO、water Leakage use this kind of detectors. Choose”Close”,it will not alarm while triggered. For wireless doorbell, please choose “Doorbell”, It will note “dingdong” anytime while be triggered. 24 Hours Silent: alarm sent when detectors triggered, siren muted, recommended for SOS(PANIC),smoke,gas,CO,water leakage detectors, etc. Stay Arm Active without Delay: when panel is armed or star armed, alarm sent when detector is trigged without delay, recommended for door, wondows, balcony,perimeter detectors. Out Arm Active without Delay: when panel is stay armed, alarm won’t be sent when detector is trigged, recommended for living room, bedroom detectors.
Pair the wireless Siren
Go to Menu→ Parts, get into the parts pairing interface · When host
shows”Learning OK”, means the detectors Sync successfully, it will list all
the name of the detectors, type, code and address code. If host shows”Device
code has been learned”,means the detectors have been learned or repeated with
the code of the other learned remote controller, need to be changed.
Delete
- Press the listed detectors ,delete the chosen detectors.
- Press “0” ,delete all the detectors.
Setting Name/Type of Wired Defense Zone
The host supports up to 4 wired defense zones, name and type of which can
be set separately.
Zone number for wired defense zones are not changeable and within 100-103
Setting wired zone 100 .for example:
- Main Menu →Parts→ Wired Zone, wired zone 100,enter setting。
- Press to set name.
- Press to set type
Stay Arm Active usually assigned to sensors on entry and exit doors, exterior
doors and windows, perimeter. Active when armed in AWAY or HOME mode. We
recommend to set Door/Window Sensor to Stay Arm Active. Out Arm Active usually
assigned to a interior area (i.e.: foyer, lobby,or room). Bypassed
automatically when armed in STAY mode. We recommend to set PIR Motion Detector
to Out Arm Active. 24 Hours Active usually assigned to a zone containing an
Emergency Button, Smoke Sensor, CO, Water Leakage and Gas Sensors. To used as
doorbell, select Doorbell.
Pair and delete the New RFID Tag
Go to Menu→ Parts→ RFID→ enter into the RFID setting interface Press or . will
list all the paired Rfid Press √, host will show” please trigger the parts”,
and will get into the 20 seconds cut down. Put the Rfid tags close to the Rfid
induction zone, While the host showing “learning ok” means the pairing
succeed, it will list all the paired rfid tags. If the host shows “this device
code already been learnt”, means the Rfid code already been learned.
Delete
After choose the list Rfid, press the related card number from the panel and
delete the relate Rfid, Press 0 to delete all the Rfids
Pairing with the wireless strobe siren
Operate the none paired wireless siren into the pairing mode(please refer the
strobe siren user manual) press the host of the siren pairing code button,
host will the show the “ code pairing signal already been sent” and sent to
the wireless siren the siren will notice “pairing succeed. (refer the strobe
siren user manual) after the pairing succeed between the siren and the host,
the host will alarm, and the siren will beep the same time.
Wireless alarm linkage Pairing alarm linkage Wireless Socket
- Go to Menu→ Parts→ alarm Socket. Getting into the wireless socket pairing interface.
- operate the none pairing wireless socket and get into the pairing mode (refer the user manual of the wireless socket) Press and hold the button of the switch until it lights up, then the switch goes into the paring mode.
- Tap ↑ and choose on and ↓ off . The hub shows and sends the on and off transmission signals to the switch. For pairing succeed wireless socket, can control on/off by host or mobile app, or can control by the socket timer.
Intelligent home appliances
Full Socket
- Press main interface: socket, get into the socket controlling interface. Code paring
- Code paring method between the host and the socket, please refer “ socket code paring with the alarm host linkage” host can code pairing with the intelligent socket
- Press ↑ choose and choose , host will send on/off wireless signal to control the socket.
- Socket pairing with the host, can use the host or the APP to control on/off, or can set the socket timer.
Socket Timer
- Host can set several groups timer to open/close the intelligent socket. Can set the socket number, time, time on/off etc. in each group.
- Press: Main menu→ Parts→Socket Timer, enter the intelligent socket timer interface.
Add the timer
- Press enter into the socket timer setting interface.
- Press or + in – ,set the socket number.
- Press or + in – ,adjust the timer time.
- Press the week item in ,set the day of the week.
- Press √ choose timer on or off.
- Press √ , finish the setting.
Edit
- Press the serial number front of the Timer, can edit the relevant timer, same as the above.
Delete
- Press behind of the timer list, delete the relevant timer.
- Press 0 delete all the Timer.
Voice Recording Alarm Recording
You can record the voice by the device up to 20seconds, the host will call
pre-set phone numbers and play the relative recorded voice.
- Main Menu→ Voice Recording→ Record and feedback. The host displays “Busy, please wait”
- When it displays “Recording”, the countdown starts.
- Speak to the host, make sure the voice record is simple and precise, This is address, intrusion detected’
- When finished, “Voice record playing” displays, and you’ll hear the playback. Click √ to save, it prompts “Saving, please wait”
- When “Operation succeed” displays, the recording is done.
Timed Arm/Disarm
You can set auto arm/disarm based on your routine to avoid duplicated
operation in everyday life or not to forget arm/disarm. Timed Arm
- Main Menu→ Clock → Timed Arm Timed Disarm
- Click ↑ and ↓ to set arm time (hour,minute)
- Click √ to select “ON
- Click √ to confirm. Timed Disarm
- Main Menu→ Clock → disarm.
- Click ↑ and ↓ to set arm time (hour,minute)
- Click √ to select “ON”.
- Click √ to confirm.
REMOTE SMS
Set Parameters by SMS
User only need to edit the SMS as below format, and send to the host SIM card
number to finish the setting
System password Address setting Content setting Address setting Content
setting
One SMS can be include one or several address and content, but need to be
separated by , the head and the end must be , each address should be 2 digits,
otherwise it may have the unexpected result, each SMS must be less than 160
bytes, we suggest to finish all the contents in one SMS.
Address | Function | Content & Scope | Factory Setting |
---|---|---|---|
35 | Redial times while dial failure | 1-255 Times | 1 Time |
36 | bell ring times while auto receivin | 1-255 Times | 1 time (in future) |
38 | User name password correct | 0000-9999 must be 4 digit | 1234 |
39 | System password correct | 0000-9999 must be 4 digit | 6666 |
43 | Parameter initialization | See note 1 | |
51 | alarm phone 1st setting | See note 2 | Closed |
52 | alarm phone 2nd setting | See note 2 | Closed |
53 | alarm phone 3rd setting | See note 2 | Closed |
54 | alarm phone 4th setting | See note 2 | Closed |
55 | alarm phone 5th setting | See note 2 | Closed |
62 | Search the GSM field strength | Empty | |
90 | Set the GPRS sever IP address | this setting only be valid while the GPRS | |
online, see note 3 | Empty | ||
92 | Set the GPRS APN | this setting only be valid while the GPRS online, see | |
note 4 | CMNET | ||
93 | Set domain name of the network time sever | us.ntp.org.cn | |
94 | Set the time difference with the standard Greenwich time | 8 |
Setting comment ( allthe example used the default system password:6666):
-
Parameter initialization:keep the learned remote controller, wireless detectors and RFID cards, others recovery to factory setting. Set the SMS content as:/666643.]
-
Alarm phone number setting format:] x00xx0000000x,A,B] Such as: xxxxxxxxxxx is the phone number(no more than 18 digits),A: alarm voice dial switch(l-on,0-off),B: SMS alarm switch(l-on,0-off).
For Example:
Set 2 alarm phone number, the one 13912345678used to receive the voice dialing and SMS,the one 075581234567only used to receive the voice dialing, then the SMS content should be: 6666’5113912345678,1,152075581234567,1,0] -
IP address setting format should be: aaa,bbb,ccc,ddd,xxxxx] Such as: aaa,bbb,ccc,ddd is the IP address,xxxxx is the port number,use the comma to separate for each address.
For example:
Set the GPRS network sever IP address is 116.62.42.223, ort number is 2001, then the SMS content setting should be: 666690116,62,42,223,2001 * -
Sal Set the local GSM operator GPRS access point APN
For example:
Local GSM operator GPRS access point APN is internet.beeline.kz, then the SMS content setting should be : I 666692internet.beeline.kz*.
Set Control Panel’ s Name by SMS
Set one name to the host, used for the prefix for the alarm SMS, so to
distinguish the position for each alarm host.
SMS setting format 1234 is the user assword, @is the commend words, “XX estate
a building” is the content name (no more than 40 digits).
Searching system setting: SMS format :] 666662], host echo:
YSTEM set:
SN:
LANGUAGE:
ENGINEER PASSWORDUSER PASSWORD:
WIFI RSSI:| Host serial number
Host language
Engineer password
GSM field strength value(0 or 99means the signal unusual)
WIFI field strength value
---|---
Searching system 2
SMS format : 666690*, host echo:
SYSTEM set2:
APN:
GPRS IP:
NTP:
TIME ZONE:
SERVER:| Name of the GPRS access point
GPRS network IP sever & client number
Network time sever domain name
GMT standard time
Sever
---|---
Alarm phone number searching setting SMS format :666651*host echo:
PHONE set:
- 1 alarm phone number, voice switch, SMS switch, general switch
- 2 alarm phone number, voice switch, SMS switch, general switch
- 3 alarm phone number voice switch SMS switch general switch
- 4 alarm phone number voice switch SMS switch general switch
- 5 alarm phone number voice switch SMS switch general switch REDIAL COUNTER: voice alarm redial counters
Delay searching setting SMS format. 6666 33* host echo:
DELAY set:
ENTRY:
EXIT:
SIREN:| delay entering(unit: second)
delay quit(unit: second)
alarming time(unit: minutes)
---|---
Searching switch setting SMS format : 666646 *,host echo:
SWITCH set:
ARM/DISARM BEEP:
ALARM BEEP:
ARM/DISARM SMS:| arm/disarm Beep switch(l: on, 0 : off)
alarm beep switch(l : on, 0 : off)
arm/disarm SMS switch(l : on, 0 : off)
---|---
Learned remote controller & detector quantities
SMS format :666626*,host echo:
DETECTOR learned:
REMOTE:
DETECTOR:
RFID:| learned remote controller quantities
learned detectors quantities
learned RFID card quantities
---|---
PHONE FUNCTION
Push in the main interface, and enter the phone number dialing interface.
Push to look over the dialed phone number.
In any of the following states, phone call operation will be forbidden: GSM
network abnormal, arm/disarm, phone alarm being in progress.
User Daily Operation
Users can operate the alarm host in any ways as below:
- On-site Remote controller, keyboards , RFID cards .
- Remote SMS
- Mobile phone APP
- GPRS alarm center
Out Arm
-
By remote control: press key to trigger “Out Arm”.
-
By keyboard: In Main Interface, press to trigger Out Arm.
-
By RFID tag: In disarm mode, put the RFID card close to the sensitive area on bottom right corner of the alarm host.
-
By remote SMS: Send SMS message 1234#1 (1234 is user password),
the alarm. host will send “System Armed!” SMS to mobile phone to confirm. -
By APP: In Main Menu, select “icon, After around 3 seconds, operation for “Out Arm” is completed, the App status icon updated to Out Arm.
-
The alarm host reminder: A reminding voice “System armed” will be heard, the main Interface displays “Armed” and “Please exit”, and an exit time progress bar appears. The user should leave the alarm zone before exit time.
If Arm/Disarm SMS switch is on, the preset phone will receive SMS of “System Armed!”.
In Out Arm mode, all defense zones are on alert statues. If there is any defense zone being triggered, the alarm host will generate sound and light alarm. Meanwhile, alarm host will send alarm SMS and make calling to preset phone number, and push alarm information to APP/GPRS alarm center. If alarm host has been learned alarming leakage smart plug, the plug will switch on when alarming.
Stay Arm
-
By remote control: press key to trigger “Stay Arm”.
-
By keyboard: In Main Interface, press to trigger Stay Arm.
-
By remote SMS: Send SMS message 1234#3 (1234 is user password), the alarm host will send“System Stay Armed!” SMS to mobile phone to confirm. By APP: In Main Menu, select “ Stay Arm” icon, after around 3 seconds, the operate for “Out Arm” is completed.
-
The alarm host reminder: A reminding voice “System armed” will be heard, the Main Interface displays “Stay Armed”. If Arm/Disarm SMS switch is on, the preset phone will receive SMS “System Stay Armed! “. In Stay Arm mode, only valid Stay Arm defense zones are on alert status. If any defense zones is been triggered, the alarm host will generate sound alarm, Meanwhile, alarm host send alarm SMS and make calling to preset phone number, and push alarm information to APP/GPRS alarm center. If alarm host learned alarming. leakage smart plug, the plug will switch on when alarming.
Disarm -
By remote control: press button to trigger “Disarm”.
-
By keyboard: press on main interface .
-
By RFID tag: in out arm/stay arm mode, put the RFID card close to the sensitive area on bottom right corner of the alarm host. By SMS: Send SMS message 1234#2 (1234 is user password), the alarm host will send“System Disarmed!” SMS to mobile phone to confirm.
-
By APP: In Main Menu, select “ Disarm” icon, after around 3 seconds, the operate for “Out Arm” is completed.
-
The alarm host reminder: A reminding voice “System Disarmed” will be heard, the Main Interface displays “Disarmed”. If Arm/Disarm SMS switch is on,the preset phone will receive SMS “System Disarmed!”. In Disarm mode, all alarm procedure will be terminated, If Arm/Disarm SMS switch is on , the preset phone will receive SMS “System Stay Armed! “. If alarm host learned alarming leakage smart plug, the plug will switch off.
SOS -
By remote control: press【SOS】button on the remote control.
-
By keyboard: Press 【SOS】 on the main interface of the alarm host.
-
By APP: Select”SOS”icon in the main menu.
-
The alarm host reminder: The Main Interface displays “Help”. The alarm host will generate a sound alarm, and send alarm SMS or make calling to the preset phone numbers , simultaneously send the alarm message to mobile phone APP or GPRS alarm center.
Confirm the operation result by SMS
ALARM & REMOTE MONITORING
The host supports multiple types of alarm. When alarm occurs, it sends alarm
messages containing the detector name and number to the user’s mobile phone,
pushes alarm information to the mobile phone APP, and sends alarm information
to the handset monitoring center. At the same time, it dials the user’s
telephone, and the user can conduct on-site monitoring and remote control
after the connection.
The host also supports the following alarm classes
- Main power failure (the alarm is effective after the main power failure lasts for 5 seconds)
- Anti-prying alarm (alarm after separation of main engine wall mounting bracket and main engine)
- Spare battery power shortage (The alarm is valid when the spare battery voltage is less than 3.45V and lasts for 10 seconds under the condition of main power failure.)
- Main power recovery.
SMS Alarm
Alarm occurred, host will send SMS manger to the preset phone numbers,should
Auto Dial Number Setting
- When alarm occurs, host will dial the preset phone numbers. (dial switch should be opened), after user answered, host will displays the current alarm type first, if there is a default recording, it will have voice notice “Press 1 is arm, Press 2 is disarm, Press 3 to monitor, Press 4 to talk”. If user finds the misinformation, press 2 to disarm and end the alarm progress. Users can also press 3 to close the scene alarm. Just hang up the phone without monitor.
- If the user fails to answer or dial, the host will continue to dial the preset phone according to the preset number of dials until the user receives the call.
Preset Telephone Remote Calls Host
When several sets of telephone numbers preset by the host actively call the
alarm host, the host will automatically connect, after the call is connected,
the host can monitor the on-site scene or control the host according to voice
prompts.
Mobile app alarm recieving procedure
When alarm occurs, panel sends push notification to your mobile phone.
Users can check the alarm type in the APP main menu. Tap on ‘Alarm Info’ to
check all records of panel operations and alarm logs.
Networking Alarm Receiving Procedure ~
When alarm occurs, host will send the alarm message to the network monitoring
center via the GPRS. The emergency response can be handled quickly after the
central police have responded to the alarm.
This function will be valid only after the host has been opened with the user
network alarm function and service.)
The IP address must be set up by using SMS, and this function will be
effective.
APN must also be set in foreign or other areas. As for the method of these two
settings, please see SMS message setting parameters).
Technical Parameters
-Input Voltage: DC5V (Micro USB Standard Interface Power Supply)
-Working Current: <500mA
-Siren Output: <80db in 1 meter
-Wireless Frequency: 433Mhz/2.4G/125K
-Wireless Coding: eV1527
-GSM System: 850/900/1800/1900MHz
-WIFI System: IEEE802.11b/g/n wireless standard
-Spare Battery: 3.7V/1000mAh
-Working Temperature: -10 ~ 55 ℃
-Relative Humidity: < 80% (no condensation)
-Product Size: 18211216MM (length x height x thickness)
PACKING LIST
- one set of host with built-in backup battery.
- micro USB 5V / 2A standard power supply, one set of power cord
- mini siren*1
- screw pack*1
- RFID tags*2
- PIR sensor*1
- window/door sensor*1
- remote controller*2