NOYAFA NF-271 Laser Distance Meter Instruction Manual

June 3, 2024
NOYAFA

Laser Distance Meter
Instruction Manual
VER: V1
NOYAFA NF 271 Laser Distance Meter

Your excellent helper in the laser distance test!

NF-271 Laser Distance Meter

NOYAFA NF 271 Laser Distance Meter - FIG 4

Please read the complete instructions including safety precautions before attempting any testing.
Please read all of the operational guide and safety regulations in this manual before operation. Improper operations without complying with this manual guide could cause damage to the device, influence measurement results, or bodily injury to the user.
The instrument is not allowed to disassemble or repair in any way. It is forbidden to do any illegal modification or performance change for the laser emitter.
Please keep it out of reach of children and avoid using it by any irrelevant personnel.
It is strictly prohibited to shoot eyes or other parts of the body with the laser; it is not allowed to take the laser to shoot any object’s surface with a strong reflection.
Due to electromagnetic radiation interference to other equipment and devices, please don’t use the meter in the plane or around medical equipment, and don’t use it in inflammable, explosive environments.
Discarded batteries or meter devices shall not process just like household garbage, please handle them in line with related laws and regulations.
Any quality issues or any questions on the meter, please contact local distributors or manufacturers in time, we are ready to offer solutions for you.

Overview

NF-271 is designed to measure Distance, Area, Volume, and Pythagorean measurement, which is mainly applied in indoor decoration and design, and building construction. In these basic functions, NF-272L has upgraded many more functions, such as Level measurement, Vertical measurement, Voice broadcast, Degree measurement, and so on.

NOYAFA NF 271 Laser Distance Meter - FIG 5

1 Add 2 Subtract
3 Power & Clear 4 Measure
5 Menu 6 Benchmark & Unit switch
7 Record query & setting

Display Instruction

NOYAFA NF 271 Laser Distance Meter - FIG 6

1 Battery condition 7 Setting
2 Beep 8 Display
3 Buzzer (271) g Data storage
Voice broadcast (272L) 10 Data storage number (271)
4 Laser function opener Degree (272L)
5 Benchmark point 11 Signal
6 Area/volume/ Pythagorean 12 Auxiliary indicator
13 Unit

Product Features

NOYAFA NF 271 Laser Distance Meter - FIG 7

Operation instructions

3.1. Turn on & off
Long press” “2s to turn on,
Long press” “2s to turn it off.

3.2. Single measurement
Press ” “turn on the laser and Press” ” again, and the result will display on the screen.
3.3. Continuous measurement
Long press” ” 2s to go in, and the MAX & MIN will show. Press “ ” or ” ” to quit. Besides, it will stop if no operation after 3mins.
3.4. Area measurement
Press “  ” to go in when the testing mode is in Single measurement, and Press” “to get the length & width, then it will work out the area on the screen.
3.5. Volume measurement
Press “ ” to go in when the testing mode is in Area measurement, and Press “ ” to get the length & width & height values, then it will work out the volume on the screen.
3.6. Pythagorean measurement
Press “ ” to go in when the testing mode is in Volume measurement, then press “ ” to get the 1 & 2 values, it will work out the height “L” on the screen.NOYAFA NF 271 Laser Distance Meter - FIG 8

3.7. Secondary Pythagorean measurement “1”
Press “ ” to go in when the testing mode is in Pythagorean measurement, then press” ” to get the 1 & 2 & 3 values, it will work out the height “L” on the screen.NOYAFA NF 271 Laser Distance Meter - FIG 9

3.7. Secondary Pythagorean measurement “2”
Press “ ” to go in when the testing mode in Pythagorean measurement 1, then press “ ” to get the 1 & 2 & 3 values, it will work out the height “L” on the screen.

3.8. Level measurement ( Only for NF-272L )
Press “ ” to go in when the testing mode is in Pythagorean measurement 2 , then press “ ” to get the 1 , it will automatically calculate the angle degree between the hypotenuse and the horizontal edge, vertical Length “H” and horizontal length “L”.NOYAFA NF 271 Laser Distance Meter - FIG
11

3.9. Vertical measurement ( Only for NF-272L )
Press “ ” to go in when the testing mode is in Level measurement, then press “ ” to go in, then press “ ” to get the 1 & 2 lengths, it will work out the degree “θ” and length “L”.
3.10. Addition & subtraction measurement
Under the Single, Area, Volume measurement mode, press “ ” to get a result “A”, then press “  ” or “ “, press “ ” again to get another result “B”, then it will automatically calculate the value (“A+B “or “A-B”).

3.11. Unit switching
Long press “ ” 2s to switch the unit, optional from (0.000m—)0.00m-03.00ft-0100″°/0—>0.0in—>0%in)
3.12. Benchmark switching
Press “ ” to go in, and you can set the benchmark to measure from the front side 0), or from the end side (2).

3.13. Unit switching
Press “ ” to go in, and you can query the data measured before. Then press “ ” or” ” to quit.
3.14. Setting
Press” ” 2s to go in, the flashing arrow on the screen indicates that the Buzzer/Voice broadcast switch setting has been entered. Press” ” or “ ” to adjust the Off/On. Then press “ ” to go voice calibration setting, by pressing” ” or “ “, adjust the parameters. Press “ ” to quit.

NOYAFA NF 271 Laser Distance Meter - FIG 14

Specification

Model NF-271 NF-272L
Range 50m 70m
Accuracy +/-1.5 mm
LCD screen FSNT with backlight
Wavelength & Output 620-680nm, <1mw
Working temperature 0-40°C
Storage temperature -20-60°C
Laser Off The 30s
Auto-off 2minutes
Protection level IP54
Power AAA 850mAh Lithlium battery
Voice broadcast X V
Degree measurement X V
Level measurement X V
Unit switching m/ft/in/ft+in
Benchmark switching
Single measurement V
Continuous measurement
Area measurement V
Volume measurement V
Pythagorean measurement
Vertical measurement X V

Addition & subtraction
measurement| X| V
Data storage| 50 sets| 99 sets
Size| 1195026mm
Weight| 100g

Packing List

1 Packing List 1 pcs
2 Carry bag 1 pcs
3 USB cable 1 pcs
4 Reflector board 1 pcs
5 AAA battery 3pcs
6 Manual 1 pcs
7 Qualification certification 1 pcs

Error reasons and solutions

Code Reason Solution
203 High or low temperature Measure at the required temperature range
220 Low battery Replace new battery
254 Wrong calculate Measure again incorrect operation
255 Weak signal Test the strong reflection ability of the target
256 Strong signal Don’t measure under strong light
257 Out-of-measure range Measure within the range
300 hardware error Restart, or contact dealer if it happens again

Overview — Laser distance meters

NOYAFA NF 271 Laser Distance Meter - FIG 15

Your excellent helper in the laser distance test!

Documents / Resources

| NOYAFA NF-271 Laser Distance Meter [pdf] Instruction Manual
NF-271, NF-272L, NF-271 Laser Distance Meter, NF-271, Laser Distance Meter, Distance Meter, Meter
---|---
| NOYAFA NF-271 Laser Distance Meter [pdf] Instruction Manual
NF-271, NF-272L, NF-275L, NF-271 Laser Distance Meter, NF-271, Laser Distance Meter, Distance Meter, Meter

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals