Product Usage Instructions

  1. Safety

    • Only use with Sealey SAC air conditioning units.
    • Do not cover the unit or obstruct air inlet/outlet grilles with items like clothing or furniture.
    • Use the material only for its intended purpose.
    • Avoid use in bathroom or shower room.
    • Store in a safe, cool, dry place away from children when not in use.
  2. Introduction
    This kit is suitable for all types of hinged windows including skylights up to 300cm total perimeter. It is designed for easy installation using the supplied roll of self-adhesive hook & loop tape. The double zip feature allows for easy positioning of the ducting at any height, helping to make your air conditioner or dryer more effective and energy-efficient.

  3. Contents

    • Window seal Velcro tape
    • Window seal with zi
    • Velcro tape
  4. Instructions

  5.   Cleaning
    Clean the window and window frame thoroughly to remove any grease and dust before installation.

  6. Cutting the Velcro Tape to Size
    Cut the Velcro tape to size using scissors. Mark the middle of the window seal and window frame for proper alignment.

  7. Attaching Velcro Tape to Window Frame
    Stick the Velcro tape around the window frame and casement, ensuring proper adhesion without covering the window itself.

  8. Sealing Window to Window Frame
    Attach the narrow side of the window seal to the Velcro tape on the window frame, ensuring a tight seal around the window.

  9. Sealing the Window
    Leave the window slightly ajar and adhere the wide side of the window seal to the Velcro tape on the window for a secure fit.

FAQ

  • Q: Can this kit be used with any air conditioning unit?
    A: This kit is specifically designed for use with Sealey SAC air conditioning units. It is recommended to check compatibility before use with other units.

  • Q: How do I store this product when not in use?
    A: Store the kit in a safe, cool, dry area away from children to prevent damage or misuse.

  • Q: Is this kit suitable for use in a bathroom?
    A: No, this kit is not intended for use in a bathroom or shower room.

  • Q: How can I ensure a proper seal around the window?
    A: Follow the instructions carefully, ensuring that the Velcro tape is properly attached and the window seal is secured tightly to prevent air leaks.

WINDOW SEALING KIT FOR AIR CONDITIONER DUCTING
MODEL NO : SACWK1

  • Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance.
  • IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
  • SEALEY-SACWK1-Window-Sealing-Kit-for-Air-Conditioner-Ducting- \(1\)Refer to instruction  manual

SAFETY

  • To be used with Sealey SAC air conditioning units see sealey website for more details.
  • DO NOT cover the unit with this material, and do not obstruct the air inlet and outlet grilles of the machine with items such as clothing, soft furnishings, furniture, bedding etc.
  • DO NOT use the material for any purpose other than that for which it is designed.
  • DO NOT use in bathroom or shower room.
  • DO NOT allow children to use, when not in use, store in a safe, cool, dry, childproof area.
  • NOTE: This material is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with this material.

 INTRODUCTION

Suitable for all types of hinged windows including skylights up to 300cm total perimeter. Easy to install using the supplied roll of self- adhesive hook & loop tape. Double zip makes positioning the ducting at any height easy. Saves energy by making the air conditioner or dryer more effective.

CONTENTS

  • Window seal
  • Velcro tapeSEALEY-SACWK1-Window-Sealing-Kit-for-Air-Conditioner-Ducting- \(2\)

INSTRUCTIONS

  1. CLEANING
    Clean the window and window frame, making them free from grease and dust.

  2. CUTTING THE VELCRO TAPE TO SIZE
    Cut the Velcro tape to size, using a pair of scissors. Mark the middle (M) of the window seal (fig.1). Mark the middle of the window frame and the casement (fig. 2-4) ( fig. 2 shows an open window, fig.3 a tilted window and fig.4 an open skylight).

  3. VELCRO TAPE TO THE WINDOW FRAME
    Stick the Velcro tape to the window frame around the window. Then stick the Velcro tape fully around the window. Stick the Velcro tape to the front side (in most cases 1 cm wide) of the casement or to the inner surface of the casement (where the window handle is attached).
    CAUTION: DO NOT stick the Velcro tape on the window.

  4. SEALING WINDOW TO WINDOW FRAME
    Stick the narrow side of the window seal to the Velcro tape on the window frame. Work from the centre and fully adhere the
    narrow side all the way around. First fasten side A, then side B, starting in the middle and working all the way to the left and right.
    IMPORTANT! When fastening, point A must be exactly opposite point B.

  5. SEALING THE WINDOW
    Leave the window ajar and adhere the wide side of the window seal to the Velcro tape of the window.
    CAUTION: Leave sufficient space, so that the window seal will not get jammed.

  6. OPENING THE WINDOW SEAL
    Open the zip of the window seal approximately 50 cm. Open the zip preferably at the positions marked with “S” and attach the exhaust air hose.

  7. ATTACHING THE AIR DISCHARGE
    Insert the air discharge hose of the air conditioning system through the hole in the window seal and close the zip until the air discharge hose is properly secured.

  8. CLOSING THE WINDOW
    If you want to close your window, simply detach the cloth from the Velcro tape. When closing the window take care that the seal is not jammed between the casement and window frame.
    NOTE: This window seal ensures that the room remains cool for a longer period of time and keeps insects and mosquitoes out.

SEALEY-SACWK1-Window-Sealing-Kit-for-Air-Conditioner-Ducting-
\(3\) SEALEY-SACWK1-Window-Sealing-
Kit-for-Air-Conditioner-Ducting- \(4\) SEALEY-SACWK1-Window-Sealing-Kit-for-Air-Conditioner-Ducting-
\(5\) The installed item will resemble fig.5 and fig.6.

  • ENVIRONMENT PROTECTION
    Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids according to local regulations.

  • Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

  • Important: No Liability is accepted for incorrect use of this product.

  • Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.

  • Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32

  •  7AR 01284 757500

  • sales@sealey.co.uk

  • www.sealey.co.uk

Original Language Version
© Jack Sealey Limited
SACWK1  Issue: 1  12/01/24