Product Information

Specifications:

  • Brand: Etac
  • Product Name: OptimaL
  • Model Number: 78352
  • Release Date: 2023-11-01
  • Version: 9
  • Dimensions: 735×800 mm (folded), 175 mm (depth)
  • Weight: 3.1 kg
  • Maximum User Weight: 150 kg

Product Usage Instructions

Device Description:
OptimaL is a foldable wall-mounted toilet arm support with an integrated supporting leg.

Intended Purpose:
The device is designed to facilitate access to the toilet for individuals with restricted functional ability. It provides stability and support for sitting down and standing up before and after performing toilet needs.

Intended User Group:
Individuals with a height of 146 cm or more, or a mass of 40 kg or more can use the device. Caregivers and clinicians/technicians may also use it.

Intended Environment:
The device is suitable for indoor use in home environments or institutions, particularly in bathrooms. Avoid using it in corrosive environments like swimming pools.

Intended Application:
The device can be used multiple times per day, for short-term or long-term use, in contact with intact skin. It is suitable for refurbishment and reuse.

Expected Service Life:
The device has an expected service life of 10 years. For detailed information, refer to www.etac.com.

Indications:
The device is suitable for individuals with balance issues,functional impairments, and a history of falls due to disability.

Contraindications:
There are no known contraindications for using the device.

Warnings:

  • Installation must be done by a professional.
  • Ignoring installation instructions may lead to injury.
  • Do not use a defective device.

Frequently Asked Questions (FAQ):

Q: Can OptimaL be used in swimming pools?
A: No, the device is not suitable for use in swimming pools or similar corrosive environments.

Q: What is the maximum weight capacity of OptimaL?
A: The maximum user weight capacity is 150 kg.

Q: How often can the device be used?
A: The device can be used several times per day for short-term or long- term use.

General information

Thank you for choosing an Etac product.
In order to avoid damage during assembly,handling and use, it is important to read this manual and save it for future reference. You can also find it at www.etac.com. You can select your language via the “International” and “Local websites” link. Here you will also find other product documentation, such as prescriber information, pre-purchase guide,and reconditioning instructions.
In the manual, the user is the person sitting in the chair. The carer is the person helping the user.

Device description
OptimaL is a foldable wall-mounted, toilet arm support with an integrated supporting leg.

Intended purpose
OptimaL (hereafter also referred to as ”the device” or ”the product”), is a medical device intended for alleviation of or compensation for a functional impairment due to an injury or disability. The device is designed to facilitate access to the toilet for people with restricted functional ability. The raised seat and/or arm supports intend to provide stability and support when sitting down and standing up before and after performing toilet needs.

Intended user group
The user group for the device is based on the individual’s functional ability and not on a specific diagnosis, health condition or age.
It is intended for individuals with a height of 146 cm or more, or a mass of 40 kg or more.
Secondary users of the device are caregivers providing assistance and clinicians/technicians who set up the device.

Intended environment
The device is intended for indoor use at home environments or institutions and is suitable for use in bathrooms, but not swimming pools or similar corrosive environments.

Intended application
The device is intended for short-term and long-term use and can be applied several times per day. The device is intended to be used in contact with intact skin.
The device is intended for refurbishment and reuse.

Expected service life
The expected service life is 10 years. For complete information regarding the service life of the device, see www.etac.com.

Indications
Indication for use is disability, including, but not limited to, an individual with fluctuating balance issues, physiological and/or functional impairment, and/or a history of falls.

Contraindications
There are no known contraindications.

Warnings
Warnings describing a risk element for a specific action or setting of the device can be found in the relevant section.

  • Installation may only be carried out by a professional.
  • Ignoring installation or assembly instructions may result in injury.
  • A defective device must not be used.
  • Do not stand on the device

Declaration of conformity
The device meets the requirements of the Medical Device Regulation (EU) 2017/745.
The device is tested and meets the requirements of the EN ISO 10993-1, SS EN 12182.

Pre-purchase information

Pre-purchase information can be found at www.etac.com.

Adverse event
In case of an adverse event occurred in relation to use of the device, it should be reported to your local dealer and the national competent authority in a timely manner.
The local dealer will forward information to the manufacturer.

Customization
is everything that goes beyond the manual’s instructions and settings. Device specially adapted by the customer must not retain Etac’s CE marking. Etac’s warranty expires. If there is any uncertainty regarding the execution of the customization, consult Etac.
Device coupled with another device may not retain either device’s CE mark unless combination agreements exist. Contact Etac for current information.

Device description…………………………..Figure A

etac-78352-OptimaL-toilet-1

  1. Supporting leg
  2. Handle
  3. Wall bracket
  4. Arm support with handle 5. Product label
  5.  Item no label

Symbols………………………………………….Figure B
Symbols in the manual and on the device:

etac-78352-OptimaL-toilet-2

  1. Warning, precaution or limitation.
  2. Useful advice and tips.
  3. Material for recycling.
  4. Maximum user weight (see technical data)
  5. Cleaning
  6. (see maintenance)
  7. Read instructions for use
  8. Product weight

Explanation item no label:………………Figure C

etac-78352-OptimaL-toilet-3

  1. Product name
  2. Product description
  3. Serial number
  4. Item number
  5. Date of manufacture
  6. Barcode acc.to GS1-128 GTIN-14 and serial number*

The device’s date of manufacture can be read from the barcode on the device. The number 11 is shown below the barcode in brackets. The number combination after these brackets is the date of manufacture.

Technical data…………………………………Figure D

etac-78352-OptimaL-toilet-4

Assembly……………………………………….. Figure E

etac-78352-OptimaL-toilet-5

Maintenance

Clean the device with a solvent-free detergent which has a pH of 5-9, or with a 70% disinfectant solution. Can be decontaminated at max. 85°C if so required.
Constituent materials are corrosion-resistant.
5-year guarantee against material and manufacturing defects. For terms and conditions,see www.etac.com.

Storage
The device should be stored indoors in a dry place at a temperature above 5°C.
If the device has been stored for a long time (more than four months), its function must be checked by an expert before use.

Accessories……………………………………. Figure F

  1. Attachment for signal device

Etac Ltd.
Unit 60, Hartlebury Trading Estate,
Hartlebury, Kidderminster,
Worcestershire, DY10 4JB
+44 121 561 2222

Promefa AG
Kasernenstrasse 3A
8184 Bachenbülach, CH
+41 44 872 97 79

Etac Supply Center AB
Långgatan 12
SE-334 33 Anderstorp

+46 371 58 73 00
info@etac.com
www.etac.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals