TCP EGP4A1 LED General Purpose Strip Luminaire Installation Guide

September 5, 2024
TCP

TCP EGP4A1 LED General Purpose Strip Luminaire

Specifications

  • Model: EGP4UA1CCTIS6C115
  • Dimming Controls: Dimmer Voltage Regulator
  • Color Temperature Options: 2700k, 3000k, 3500k, 4000k, 5000k
  • Manufacturer: TCP (Technical Consumer Products Inc.)
  • Website: tcpi.com

Product Usage Instructions

Important Safety Information
WARNING: To avoid electric shock and fire hazards, this product must be installed by a qualified electrician familiar with the construction and operation of the luminaire.

Electrical Connection
Ensure that only UL-listed wiring connectors and wiring with a minimum temperature rating as indicated on the fixture label are used for electrical connections.

Luminaire Installation
For dimming controls, refer to the control manufacturer’s wiring instructions. The internal circuit of the lamp can detect the voltage of the Dimmer to control the output current for continuous dimming.

Mounting Instructions
Use the provided V Hook for chain mounting. Ensure proper end cap alignment for secure installation.

CCT Switch
This luminaire offers field-adjustable wattage and color temperature options. Select from 2700k, 3000k, 3500k, 4000k, or 5000k as needed.

Contact Information
If you require further assistance or information not covered in these instructions, please contact TCP Customer Service Department at 800-324-1496.

FAQ

  • Q: What should I do if the luminaire causes interference with radio or television reception?
    A: Try reorienting or relocating the receiving antenna, increasing separation between the luminaire and receiver, connecting the equipment to a different circuit, or consult a radio/TV technician for help.

  • Q: Can I use non-UL listed wiring connectors with this product?
    A: No, only use UL-listed wiring connectors to ensure safety and compliance with regulations.

IMPORTANT : Install by a Qualified Electrician. Please read the instructions before proceeding with installation. Keep these instructions for future reference.

IMPORTANT : Install by Qualified Electrician. Please read the instructions before proceeding with installation. Keep these instructions for future reference.

RISK OF ELECTRIC SHOCK

  • Turn off power prior to inspection, installation or removal of fixture.
  • Ensure electrical enclosure is properly grounded by National Electrical Code (NEC).

RISK OF FIRE

  • Product must be installed by NEC and/or applicable local codes by a qualified licensed electrician.
  • Wiring connections should be made with UL approved wire connectors.

THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED

ATTENTION

  • Use care when handling the luminaire. Do not drop, press, or bend the light panel to avoid damage during installation.
  • Prior to installation, carefully unpack and properly inspect luminaire for any damage or loose connections that may have occurred during shipping.

ELECTRICAL CONNECTION

Warning : Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE : This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

LUMINAIRE INSTALLATION

NOTE :For connection to dimming controls, consult the control manufacturer’s instructions.

  • USE ONLY UL-LISTED WIRING CONNECTORS AND UL-LISTED WIRING HAVING A MINIMUM TEMPERATURE RATING AS SHOWN ON THE FIXTURE LABEL.
  • The internal circuit of the lamp can detect the voltage of the Voltage Regulator or Dimmer to control the output current change to achieve continuous dimming.

Chain Mounting with V Hook

  • Attach customer-supplied V-Hooks to each end of the luminaire base using designated keyhole slots. (See Figure B)
  • Attach the customer-supplied chain to the V-Hooks and mounting surface per applicable codes.
  1. A: End Cap
  2. B: Chain Mounting with V Hook

CCT-PRODUCT

These instructions are not intended to cover all details or variations in your equipment or your particular requirements for installation, operation or maintenance. Should further information on this product be needed that is not covered by these general installation instructions, please contact the TCP Customer Service Department at phone number 800-324-1496 for further assistance.

Field-Adjustable Wattage & CCT

The end users may adjust the color temperature by the one DIP switch buttons integrated into the driver. Each DIP switch is accommodated with 5 options (left, middle and right ),corresponding to 5 color temperatures, which can perform the desired color temperature.

  1. DIP switches are located on the top of driver.
  2. Select color temperature by sliding switch left or right respectively to the desired value.

325 Campus Dr.
Aurora, Ohio 44202
P: 800-324-1496 tcpi.com
©TCP ОСТ 2017/WF96556

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals