Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble-free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to instructions

SAFETY

1.1. ELECTRICAL SAFETY
WARNING! It is the user’s responsibility to check the following:
Check all electrical equipment and appliances to ensure that they are safe before use. Inspect power supply leads, plugs, and all electrical connections for wear and damage. Sealey recommend that an RCD (Residual Current Device) is used with all electrical products. You may obtain an RCD by contacting your local Sealey stockist.
If the product is used in the course of business duties, it must be maintained in a safe condition and routinely PAT (Portable Appliance Test) tested.
For electrical safety information, it is important that the following information is read and understood.
1.1.1. Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply.
1.1.2. Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.
1.1.3. Important: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with the correct fuse – see fuse rating in these instructions.
X DO NOT pull or carry the appliance by the power cable.
X   DO NOT pull the plug from the socket by the cable.
X   DO NOT use worn or damaged cables, plugs, or connectors. Ensure that any faulty item is repaired or replaced immediately by a qualified electrician.
1.1.4. This product is fitted with a BS1363/A 13 Amp 3 pin plug.
If the cable or plug is damaged during use, switch the electricity supply and remove it from use.
Ensure that repairs are carried out by a qualified electrician.
Replace a damaged plug with a BS1363/A 13 Amp 3 pin plug. If in doubt contact a qualified electrician.
a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.
b) Connect the BROWN live wire to the live terminal ‘L’.
c) Connect the BLUE neutral wire to the neutral terminal ‘N’.
Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight. Sealey recommends that repairs are carried out by a qualified electrician.
1.2. GENERAL SAFETY
WARNING!
The pump must be used in accordance with Health & Safety, government, local authority, and water authority rules and regulations.
** Familiarise yourself with application and limitations, as well as the specific potential hazards peculiar to the pump.
WARNING! Disconnect the pump from the mains power before changing accessories, servicing or performing any maintenance.
**
Maintain the pump in good condition (use an authorized service agent). Keep the pump clean.
Replace or repair damaged parts. Use genuine parts only. Unauthorized parts may be dangerous and will invalidate the warranty.
Only use for pumping liquids under 35°C.
If pump is used to pump water from a well, drain or deep receptacle, take adequate precautions to stop persons or animals from falling in.
Use the built-in handle to lower or raise the pump. It may be necessary to attach a suitable rope or pulley to the handle.
If the bottom of the water container is covered with sludge, sand, gravel or mud etc, suspend the pump or place it on a raised base to operate above the solid matter. Sand and such substances will reduce the working life of the pump, and invalidate your warranty.
In flood situations, the user is responsible for ensuring that appropriate backup procedures, alarms, etc are correctly installed in case of pump failure.
** In swimming pools, fish ponds, etc, ensure the location is clear of people and animals, including removal of fish from the pond.
X This pump is not designed for continuous use in a fish pond or similar water feature or display.
X DO NOT operate the pump if any parts are damaged or missing as this may cause failure and/or possible personal injury.
X DO NOT use the pump for any purpose other than for that which it is designed.
X DO NOT use to pump chemicals, fuels or salt water.
X DO NOT insert hands into the mouth of the pump as this could lead to injury.
X DO NOT use to pump septic tanks or settling pits. DO NOT pump any liquids other than water.
X DO NOT operate the pump out of water. The pump pick-up area must be completely submerged during operation.
X DO NOT exceed the maximum submersible depth – see specifications.
X DO NOT operate the pump during freezing temperatures. DO NOT leave the pump in water that may freeze.
X DO NOT use in swimming pools if people could come into contact with the water whilst the pump is in use.
X DO NOT use for pumping sea water or inflammable, corrosive, explosive or dangerous liquids.
X DO NOT carry the pump by its electrical cable, or outlet pipe. Use the handle only.
X When not in use switch off the pump and remove the plug from the power supply. Rinse pump, drain out any water, and store in a frost-free, safe location.
WARNING!** DO NOT allow uncontrolled discharge of contaminated water which would pollute the environment.

INTRODUCTION

Manufactured from corrosion-resistant materials with – stainless steel motor case and Noryl® base cover
– WPD235A.V2
– Stainless steel body and motor case
– WPS225A.V2
Fitted with automatic cut-out. Designed for operation in dense and dirty water. Suitable for the effective drainage of cellars, sinks, cisterns, baths and the general transfer of water and dense liquids.

SPECIFICATION

Model No:……………………………………………….. WPD235A.V2 …………………………………….. WPS225A.V2

Cut-Out: ……………………………………………………….. Automatic ………………………………………….. Automatic
Maximum Head: ………………………………………………………. 8m …………………………………………………. 7.5m
Maximum Output/Min: ………………………………….. 217L(47gal) ……………………………………….. 225L(49gal)
Maximum Particle Size:………………………………………… 35mm ……………………………………………….. 15mm
Maximum Water Depth:…………………………………………….. 7m ……………………………………………………. 5m
Minimum Water Depth:…………………………………………. 40mm ……………………………………………….. 30mm
Motor Power:………………………………………………………..750W ………………………………………………… 750W
Outlet OD: ……………………………………………………….. Ø38mm ………………………………………………Ø38mm
Supply: …………………………………………………………………230V …………………………………………………. 230V

OPERATION

WARNING! Ensure you read, understand and apply safety instructions.
4.1. Fit appropriate discharge pipe to pump outlet and secure with clip. Ensure the diameter of the discharge pipe is the same as, or greater than, the outlet diameter. A smaller pipe will adversely affect the pump flow rate.
4.2. Position the pump in the water, and place the outlet pipe securely in the discharge receptacle or area. We recommend the pump is submerged with its discharge outlet facing up to release any trapped air.
4.3. Plug the pump into the electrical mains supply and switch it on. The pump will automatically turn on as the level of water rises (fig.1.A). As the water level lowers, the float will automatically switch the pump off as it reaches the minimum height (B). The float may be adjusted by shortening or lengthening the cable. The pump will switch on if the water level is up to or above the maximum length of the float cable. To function correctly the float must move freely. Ensure the float can do so and that the cable is not restricted. Check that the pump and discharge are working correctly.
4.4. The water into which the pump is placed will act as the motor cooling agent. For this reason, the pump must remain submerged at all times. Should the pump have to be used in shallow water DO NOT operate for more than 10 minutes. Failure to follow this rule will damage the unit and will invalidate your warranty.
NOTE See fig.2 to determine the minimum clearance required if using a pump in a restricted area i.e. well, etc.

MAINTENANCE

WARNING! With the exception listed below, all pump, float and electrical cable service maintenance and repair must only be undertaken by an authorized service agent. Failure to observe this rule may be dangerous and will invalidate your warranty.
WARNING! Ensure the pump is disconnected from the main power supply before attempting any service or maintenance.
5.1. Keep all parts of the pump clean. Rinse, drain and allow to dry before storing the pump.
5.2. Regularly check the water inlet on the base of the pump to ensure there are no blockages. To access the impeller carefully undo the base hex-headed screws and remove the base. Clean the impeller and replace the base ensuring that the O ring is correctly located.
DO NOT dismantle any other part of the unit.

TROUBLESHOOTING

TROUBLESHOOTING

a. Motor operates but there is no suction.| 1. Water level below min suction depth.
2. Air bubbles in the pump accumulated during submersion. or float is incorrectly positioned so the pump does not stop at a minimum level and sucks in air.
3. Clogged intake filter or discharge pipe.| 1. Stop the pump.
2. Release air by inclining the pump and re-immersing it in water.
3. Remove blockage, and clean the unit.
b. Reduced water volume for the level of water| 1. Discharge pipe bent. or pinched.
2. Discharge pipe too narrow.
3. Pump partially blocked.| 1. Straighten pipe.
2. Use a wider diameter pipe.
3. Clean pump.
c. The pump will not start or suddenly stops during
operation.| 1.No electrical power.
2. Float not working.
3. Impeller is jammed.| 1. Check cable, plug, and fuse.
2. Contact the authorized service agent.
3. Clean the pump.

ENVIRONMENT PROTECTION
** Recycle unwanted materials instead of disposing of them as waste. All tools, accessories, and packaging should be sorted, taken to a recycling center, and disposed of in a manner that is compatible with the environment. When the product becomes completely unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids according to local regulations.
WEEE REGULATIONS
Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment (WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid waste authority for recycling information.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications, and component parts without prior notice. Please note that other versions of this product are available. If you require documentation for alternative versions, please email or call our technical team on [email protected] or 01284 757505.
Important: No Liability is accepted for incorrect use of this product.
Warranty:** Guarantee is 12 months from purchase date, proof of which is required for any claim.

Sealey Group, Kempson Way, Suffolk Business
Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500
01284 703534
[email protected]
www.sealey.co.uk
**** © Jack Sealey Limited
Original Language Version

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

SEALEY User Manuals

Related Manuals