TESLA TT26EX21 Split Type Air Conditioner User Manual
- June 1, 2024
- Tesla
Table of Contents
- TESLA TT26EX21 Split Type Air Conditioner
- Product Specifications
- Product Usage Instructions
- Frequently Asked Questions
- SAFETY RULES AND RECOMMENDATIONS FOR THE INSTALLER
- NAMES OF PARTS
- EMERGENCY & AUTO-RESTART FUNCTION
- OPERATING INSTRUCTIONS
- INSTALLATION
- Refrigerant piping connection
- INFORMATION FOR THE INSTALLER
- MAINTENANCE
- TROUBLESHOOTING
- INSTRUCTION FOR SERVICING
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
TESLA TT26EX21 Split Type Air Conditioner
Product Specifications
- Product Type: Split-Type Air Conditioner
- Model Variants: TT26EX21-0932IA, TT34EX21-1232IA, TT51EX21-1832IA, TT68EX21-2432IA, TT26EX81-0932IAW, TT34EX81-1232IAW, TT34EXC1-1232IAWPC, TT34EX82BM-1232IAW, TT34EX82SM-1232IAW, TT51EX81-1832IAW, TT68EX81-2432IAW Ver. 2022
Product Usage Instructions
Safety Rules and Recommendations
It is important to follow safety rules and recommendations for both installers and users as outlined in the manual.
Names of Parts
Indoor Unit
- Front panel
- Air filter
- Optional filter (if installed)
- LED Display
- Signal receiver
- Terminal block cover
- Ionizer generator (if installed)
- Deflectors
- Emergency button
- Indoor unit rating label (Stick position optional)
- Airflow direction louver
- Remote controller
Outdoor Unit
- Air outlet grille
- Outdoor unit rating label
- Terminal block cover
- Gas valve
- Liquid valve
Indoor Unit Display
Led | Function |
---|---|
SLEEP | Lights up during Timer operation when the air conditioner is |
operational. Displays the malfunction code when a fault
occurs.
Temperature display / Error code| If present, displays temperature or error
code.
TIMER| Lights up during Timer operation.
Emergency & Auto-Restart Function
Emergency function:
The emergency button is located on the E-box cover of the unit under the front
panel.
Auto-restart function:
The unit is preset with an auto-restart function. In case of a power failure,
the settings are memorized. When power is restored, the unit will restart with
the previous settings.
Frequently Asked Questions
- Q: How do I clean the air filters?
- A: To clean the air filters, carefully remove them from the unit and wash with lukewarm water. Allow them to dry completely before reinstalling.
- Q: How often should I service the air conditioner?
- A: It is recommended to service the air conditioner at least once a year to ensure optimal performance.
“`
SPLIT-TYPE AIR CONDITIONER
USER MANUAL
ENG
BIH/ MNE
BG
For R32 DC Inverter models:
TT26EX21-0932IA TT34EX21-1232IA TT51EX21-1832IA TT68EX21-2432IA
TT26EX81-0932IAW TT34EX81-1232IAW TT34EXC1-1232IAWPC TT34EX82BM-1232IAW
TT34EX82SM-1232IAW TT51EX81-1832IAW TT68EX81-2432IAW
GR HR HU MKD RO SLO SRB
Ver. 2022
ENG
BIH/ MNE
OPERATING INSTRUCTION
Note: All the pictures in this manual are just schematic diagrams, the actual
is the standard. Please read this owner’s manual carefully and thoroughly
before operating the unit! Take care of this manual for future reference.
UPUTSTVO ZA UPOTREBU
Napomena: Sve slike u ovom prirucniku su samo sematski dijagrami, fizicki
proizvod je standard. Molimo Vas da pazljivo i temeljno procitate ovo uputstvo
za upotrebu prije koriscenja ureaja! Sacuvajte ovo uputstvo za buducu
upotrebu.
BG
: , . , !
GR HR
: , . ! .
UPUTE ZA UPOTREBU
Napomena: Sve slike u ovom prirucniku su samo shematski dijagrami, fizicki
proizvod je standard. Molimo Vas da pazljivo i temeljito procitate ovo
uputstvo za upotrebu prije koristenja ureaja! Cuvajte ovaj prirucnik za buduce
koristenje.
HU
FELHASZNÁLÓI KÉZIKÖNYV
Megjegyzés: A kézikönyvben található képek csak sematikus ábrák, az aktuális a
szabvány. Kérjük, figyelmesen olvassa el ezt a kézikönyvet mieltt mködtetné az
eszközt! rizze meg ezt a kézikönyvet a késbbiekre is.
MKD RO SLO
: , . ! .
MANUAL DE UTILIZARE
Nota: Fotografiile din acest manual sunt doar diagrame schematice. V rugm s
citii “Manualul de Utilizare” cu atenie, înainte de a utiliza aerul
condiionat, pentru a asigura funcionarea corespunztoare. Pstrai manualul
pentru referine ulterioare.
PRIROCNIK ZA UPORABO
Opomba: Vse slike v tem prirocniku so le shematske risbe, dejansko stanje je
standard. Prosimo, da pred uporabo skrbno in temeljito preberete ta prirocnik
za uporabo! Prirocnik shranite za kasnejso uporabo.
SRB
UPUTSTVO ZA UPOTREBU
Napomena: Sve slike u ovom prirucniku su samo sematski dijagrami, fizicki
proizvod je standard. Molimo Vas da pazljivo i temeljno procitate ovo uputstvo
za upotrebu pre koriscenja ureaja! Sacuvajte ovo uputstvo za buducu upotrebu.
ENG
SAFETY RULES AND RECOMMENDATIONS FOR THE INSTALLER
· Read this guide before installing and using the appliance. · During the
installation of the indoor and outdoor units the access to the working area
should be forbidden to
children. Unforeseeable accidents could happen. · Make sure that the base of
the outdoor unit is firmly fixed. · Check that air cannot enter the
refrigerant system and check for refrigerant leaks when moving the air
conditioner. · Carry out a test cycle after installing the air conditioner and
record the operating data. · The ratings of the fuse installed in the built in
control unit are 4A / 250V . · Protect the indoor unit with a fuse of suitable
capacity for the maximum input current or with another overload
protection device. · Ensure that the mains voltage corresponds to that stamped
on the rating plate. Keep the switch or power plug
clean. Insert the power plug correctly and firmly into the socket, thereby
avoiding the risk of electric shock or fire due to insufficient contact. ·
Check that the socket is suitable for the plug , otherwise have the socket
changed. · The appliance must be fitted with means for disconnection from the
supply mains having a contact separation in all poles that provide full
disconnection under overvoltage category III conditions, and these means must
be incorporated in the fixed wiring in accordance with the wiring rules. · The
air conditioner must be installed by professional or qualified persons. · Do
not install the appliance at a distance of less than 50 cm from inflammable
substances (alcohol, etc.) or from pressurised containers (e.g. spray cans). ·
If the appliance is used in areas without the possibility of ventilation,
precautions must be taken to prevent any leaks of refrigerant gas from
remaining in the environment and creating a danger of fire · The packaging
materials are recyclable and should be disposed of in the separate waste bins
.Take the air conditioner at the end of its useful life to a special waste
collection centre for disposal. · Only use the air conditioner as instructed
in this booklet. These instructions are not intended to cover every possible
condition and situation . As with any electrical household appliance , common
sense and caution are therefore always recommended for installation, operation
and maintenance. · The appliance must be installed in accordance with
applicable national regulations. · Before accessing the terminals , all the
power circuits must be disconnected from the power supply. · The appliance
shall be installed in accordance with national wiring regulations. · This
appliance can be used by children aaged from 8 years and above and persons
with reduced physical, sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or instruction concerning
use of the appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and user maintenance
shall not be made by children without supervision.
SAFETY RULES AND RECOMMENDATIONS FOR THE USER
· Do not try to install the conditioner alone; always contact specialized
technical personnel. · Cleaning and maintenance must be carried out by
specialized technical personnel. In any case disconnect the
appliance from the mains electricity supply before carrying out any cleaning
or maintenance. · Ensure that the mains voltage corresponds to that stamped on
the rating plate. Keep the switch or power plug
clean. Insert the power plug correctly and firmly into the socket , thereby
avoiding the risk of electric shock or fire due to insufficient contact. · Do
not pull out the plug to switch off the appliance when it is in operation,
since this could create a spark and cause a fire, etc. · This appliance has
been made for air conditioning domestic environments and must not be used for
any other purpose , such as for drying clothes, cooling food, etc. · The
packaging materials are recyclable and should be disposed of in the separate
waste bins . Take the air conditioner at the end of its useful life to a
special waste collection center for disposal.
3
ENG
· Always use the appliance with the air filter mounted . The use of the
conditioner without air filter could cause an excessive accumulation of dust
or waste on the inner parts of the device with possible subsequent failures.
· The user is responsible for having the appliance installed by a qualified
technician , who must check that it is earthed in accordance with current
legislation and insert a thermomagnetic circuit breaker.
· The batteries in remote controller must be recycled or disposed of properly.
Disposal of Scrap Batteries –Please discard the batteries as sorted municipal
waste at the accessible collection point.
· Never remain directly exposed to the flow of cold air for a long time. The
direct and prolonged exposition to cold air could be dangerous for your health
.Particular care should be taken in the rooms where there are children , old
or sick people.
· If the appliance gives off smoke or there is a smell of burning, immediately
cut off the pow er supply and contact the Service Centre.
· The prolonged use of the device in such conditions could cause fire or
electrocution. · Have repairs carried out only by an authorised Service Centre
of the manufacturer . Incorrect repair could
expose the user to the risk of electric shock, etc. · Unhook the automatic
switch if you foresee not to use the device for a long time. The airflow
direction must be
properly adjusted. · The flaps must be directed downwards in the heating mode
and upwards in the cooling mode. · Only use the air conditioner as instructed
in this booklet. These instructions are not intended to cover every
possible condition and situation. As with any electrical household appliance,
common sense and caution are therefore always recommended for installation ,
operation and maintenance. · Ensure that the appliance is disconnected from
the power supply when it will remain inoperative for a long period and before
carrying out any cleaning or maintenance. · Selecting the most suitable
temperature can prevent damage to the appliance.
SAFETY RULES AND PROHIBITIONS
· Do not bend, tug or compress the power cord since this could damage it.
Electrical shocks or fire are probably due to a damaged power cord.
Specialized technical personnel only must replace a damaged power cord.
· Do not use extensions or gang modules. · Do not touch the appliance when
barefoot or parts of the body are wet or damp. · Do not obstruct the air inlet
or outlet of the indoor or the outdoor unit. The obstruction of these openings
causes a reduction in the operative efficiency of the conditioner with
possible consequent failures or damages. · In no way alter the characteristics
of the appliance. · Do not install the appliance in environments where the air
could contain gas , oil or sulphur or near sources of
heat. · This appliance is not intended for use by persons (including children
) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a person
responsible for their safety. · Do not climb onto or place any heavy or hot
objects on top of the appliance. · Do not leave windows or doors open for long
when the air conditioner is operating. · Do not direct the airflow onto plants
or animals. · A long direct exposition to the flow of cold air of the
conditioner could have negative effects on plants and animals. · Do not put
the conditioner in contact with water. The electrical insulation could be
damaged and thus causing electrocution. · Do not climb onto or place any
objects on the outdoor unit · Never insert a stick or similar object into the
appliance. It could cause injury. · Children should be supervised to ensure
that they do not play with the appliance. If the supply cord is damaged, it
must be replaced by the manufacturer,its service agent or similarly qualified
persons in order to avoid a hazard.
4
ENG
NAMES OF PARTS
Indoor unit
No. Description
1 Front panel
2 Air filter
3 Optional filter (if installed)
4 LED Display
5 Signal receiver
6 Terminal block cover
7 Ionizer generator(if installed)
8 Deflectors
9 Emergency button
10
Indoor unit rating label (Stick position optional)
11 Airflow direction louver
12 Remote controller
Outdoor unit
No. Description 13 Air outlet grille 14 Outdoor unit rating label 15 Terminal
block cover 16 Gas valve 17 Liquid valve
Note: The above or the next pages mentioned figures are only intended to be a
simple diagram of the appliance and may not correspond to the appearance of
the units that have been purchased.
5
ENG
INDOOR UNIT DISPLAY
No. Led 1 SLEEP
2
Temperature display (if present) / Error code
3 TIMER
Function
SLEEP mode
1. Lights up during Timer operation when the air conditioner is operational
2. Displays the malfunction code when fault occurs.
Lights up during Timer operation.
The shape and position of switches and indicators may be different according to the model, but their function is the same.
EMERGENCY & AUTO-RESTART FUNCTION
Emergency function
If the remote controller fails to work or maintenance necessary, proceed as
following: · Open and lift the front panel up to an angle to reach
the emergency button. · For heating model, press the emergency button
at first time, the unit will operate in COOL mode. Press at second time within
3 seconds, the unit will operate in HEATmode. Press at third time after 5
seconds, the unit will turn off. · For cooling only model, press the emergency
button at first time, the unit will operate in COOL mode. Press again, the
unit will turn off.
front panel
Emergency button The emergency button is located on E-box cover of the unit
under the front panel.
Auto-restart function
The appliance is preset with an auto-restart function. In case of a sudden
power failure, the module will memorizes the setting conditions before the
power failure. When the power restores, the unit will restart automatically
with the previous settings preserved by the memory function.
The shape and position of the emergency button may be different according to
the model, but their function is the same.
6
ENG
REMOTE CONTROLLER
No.
Button
Function
1
To turn on or off the air conditioner .
2
OPTION To activate or deactivate optional function (Check below table).
3
To decrease temperature, time setting or choose the function.
4
To increase temperature , time setting or choose the function.
5
ECO
To activate / deactivate the ECO function which enables the unit automatically to sets the operation to achieve energy savings.
6
TURBO
Press this button to activate/deactivate the Superfunction which enables the unit to reach the preset temperature in the shortest time.
7
MODE
To select the mode of operation (AUTO COOL DRY FAN HEAT)
To select the fan speed of auto/mute/low/mid/mid/high/high/turbo , cycle as below
8
FAN
Flashing
1. If press time interval is over 2 seconds, to activate the swing of vertical flap(left/right)
or deactivate it.
9
2. If press time interval is in 2 seconds, the swing angle range of vertical flap will cycle as below.
deactivate
1. If press time interval is over 2 seconds, to activate the swing of horizontal
deflectors(left/right) or deactivate it.
10
2. If press time interval is in 2 seconds, the swing angle range of horizontal deflectors(left/right) will cycle as below.
Flashing
deactivate
ON/OFF ON
OFF
Mode AUTO COOL DRY FAN HEAT AUTO COOL DRY FAN HEAT
OPTIONS TIMER DISPLAY HEALTH I FEEL TIMER DISPLAY HEALTH SLEEP MILDEW I FEEL TIMER DISPLAY HEALTH MILDEW I FEEL TIMER DISPLAY HEALTH I FEEL TIMER DISPLAY HEALTH SLEEP I FEEL 8°C H CLEAN TIMER DISPLAY HEALTH I FELL CLEAN TIMER DISPLAY HEALTH SLEEP MILDEW I FEEL CLEAN TIMER DISPLAY HEALTH MILDEW I FEEL CLEAN TIMER DISPLAY HEALTH I FEEL CLEAN TIMER DISPLAY HEALTH SLEEP I FEEL 8°C H
7
ENG
You will hear a beep when you press the following buttons or select the following optional functions, though the actual model haven’t this function, we express our apologies:
Optional Function: COMFORTABLE COOLING
airflow Optional Function: COMFORTABLE HEATING
airflow
HEALTH Optional Function: generate the ionizer button: SWING LEFT/RIGHT
Hold and together over 3 seconds to activate of deactivate the Lock function
Meaning of symbols on the liquid crystal display
No.
Symbols
Meaning
1
Single indicator
2
Lock function indicator
3
Battery indicator
4
AUTO
Mode Auto function indicator
5
COOL
Mode Cooling indicator
6
DRY
Mode Dry indicator
7
FAN
Mode Fan indicator
8
HEAT
Mode Heating indicator
9
ECO
ECO function indicator
8
No. 10
11
12
Flashing
13 14 15
16
17
18
19
ENG
Symbols TIMER
Flashing
Meaning Timer indicator Temperature indicator Fan speed indicator: Auto low low mid mid high Mute indicator SUPER indicator Flap swing angle indicator Deflector swing angle indicator Comfortable cooling airflow indicator Comfortable heating airflow indicator
Optional functions indicator Notes: There is no HEALTH/WIND FREE/ GEN MODE functions for current models, we express our apologies.
The following angle can not be selected for current models, we express our
apologies.
Flashing
Replacement of Batteries
Remove the battery cover plate from the rear of the remote controller, by
sliding it in the direction of the arrow. Install the batteries according the
direction (+and -) shown on the Remote Controller. Reinstall the battery cover
by sliding it into place.
Use 2 LRO 3 AAA (1.5V) batteries . Do not use rechargeable batteries . Replace
the old batteries with new ones of the same type when the display is no longer
legible. Do not dispose batteries as unsorted municipal waste. Collection of
such waste separately for special treatment is necessary.
Note: Child-lock: Press and together to activate Display ON/OFF: Long press
ECO button
Please remove batteries to avoid leakage damage when not using for a long
time.
9
ENG
WARNING! 1. Direct the remote controller toward the Air conditioner. 2. Check
that there are no objects between the remote control
and the Signal receptor in the indoor unit. 3. Never leave the remote
controller exposed to the rays of the
sun. 4. Keep the remote controller at a distance of at least 1m from
the television or other electrical appliances.
OPERATING INSTRUCTIONS
The air sucked by the fan enters from the grill and passes through the filter,
then it is cooled/dehumidified or heated through the heat exchanger.
The direction of the air outlet is motorized up and down by flaps, and
manually moved right and left by the vertical deflectors, for some models, the
vertical deflectors could be controlled by motor as well.
Filter Heat Exchanger
Signal receptor
“Swing” control of the air flow
1. Press the button to activate the FLAP , 1. If press time interval is in 2
seconds, the swing will cycle as below
deactivate
2. If press time interval is over 2 seconds, it will be deactivate the air
flow is directed alternatively from up to down .In order to guarantee an even
diffusion of the air in the room.
2. Press the button to activates the motorized deflectors 1. If press time
interval is in 2 seconds the swing will cycle as below
flashing deactivate
2. If press time interval is over 2 seconds, it will be deactivate the air
flow is directed alternatively from left to right. (Optional function, depends
on the models). The deflectors are positioned manually and placed under the
flaps. They allow to direct the air flow rightward or leftward.
WARNING!
· This adjustment must be done while the appliance is switched off.
· Never position “Flaps” manually, the delicate mechanism might seriously
damaged!
· Never poke fingers, sticks or other objects in the air inlet or outlet
vents. Such accidental contact with live pants might cause unforeseeable
damage or hurt.
· The following angle can not be selected for current models, we express our
apologies.
“flap” movement
Fan
Deflectors
“flaps”
flashing
10
ENG
Cooling mode
The cooling function allows the air condit- ioner to cool the room and at the
same time reduces Air humidity.
To activate the cooling function (COOL) , press the MODE button until the
symbol COOL appears on the display. The cooling function is activated by
setting the button or at a temperature lower than that of the room. To
optimize the function of the Air conditioner, adjust the temperature (1), the
speed (2) and the direction of the air flow (3) by pressing the button
indicated.
Heating mode
The heating function allows the air conditi- oner to heat the room.
To activate the heating function (HEAT) , press the MODE button until the
symbol HEAT appears on the display. With the button or set a temperature
higher than that of the room. To optimize the function of the Air conditioner
adjust the temperature (1), the speed (2) and the direction of the air flow
(3) by pressing the button indicated.
WARNING!
In HEATING operation, the appliance can automatically activate a defrost cycle, which is essential to clean the frost on the condenser so as to recover its heat exchange function. This procedure usually lasts for 2-10 minutes during defrosting,indoor unit fan stop operation. After defrosting ,it resumes to HEATING mode automatically.
Dry mode
This function reduces the humid- ity of the air to make the room more
comfortable.
To set the DRY mode, Press MODE until DRY appears in the display. An automatic function of alternating cooling cycles and air fan is activated.
Fan mode (not FAN button)
The air conditioner works in only ventilation.
To set the FAN mode, Press MODE until FAN appears on the display.
Auto mode
Automatic mode.
To activate the AUTO mode of operation, press the MODE button on the remote
controller until the symbol AUTO appears on the display. In AUTO mode , the
air conditioner will run automatically according to the room temperature.
11
ENG
Display function (indoor display)
Switch on/off the LED display on panel
Press OPTION at the fist time, select the DISPLAY by pressing the
button or until symbol DISPLAY is flashing; Press OPTION again to
switch off the LED display on the panel, and
appears on the
remote controller display. Do it again to switch on the LED display.
ECO function
The air conditioner works in economic mode
Only in Heating or Cooling model, press ECO button and symbol ECO will appear
on the display, the air conditioner will work in energy saving process. To
cancel this function, pressing the MODE to switch other mode or pressing the
ECO button again.
Turbo function
To activate turbo function,pressing the button TURBO or pressing the button
FAN until symbol appears on the display. To cancel this function, pressing the
FAN to switch other fan speed or pressing the TURBO button again. In
AUTO/HEAT/COOL/FAN mode, When you select TURBO feature, it will use the
highest fan setting to blow strong airflow.
Sleep function
Press OPTION at the fist time , select the SLEEP by pressing the button or
until symbol SLEEP is flashing; Press OPTION again to activate
the SLEEP function, and SLEEP appears on the display. Do it again to
deactivate this function. After 10 hours running in sleep mode, the air
conditioner will return to the previous setting mode.
Mildew function
Press OPTION at the fist time , select the MILDEW by pressing the button or until symbol MILDEW is flashing;
Press OPTION again to activate the MILDEW function, and
appears on the display. Do it again to
deactivate this function. This function enable the air conditioner still blow airflow about 15 minutes to dry the
indoor inner parts to avoid mildew, when the air conditioner is off.
Note: MILDEW function only available in DRY/COOLING mode
12
ENG
Self-clean function
Switch off the air conditioner.
Press OPTION at the fist time , select the CLEAN by pressing the
button or until symbol CLEAN is flashing; Press OPTION again to
activate the CLEAN function, and
appears on the display. Do it
again to deactivate this function.
1. This function help carry away the accumulated dirt, bacteria, etc from the
evaporator.
2. This function will run about 30 minutes, and it will return to the pre-
setting mode .You can press or MODE to cancel this function during the
process. You will hear 2 beeps when it’s finished or cancelled.
3. It’s normal if there are some noise during this function process, as
plastic materials expand with heat and contract with cold.
4. We suggest operate this function as the following ambient condition to
avoid certain safety protection features.
Indoor unit
Temp<30°C
Outdoor unit
5°C <Temp<30°C
5. We suggest operate this function per 3 months.
8°C heating function
Only can be set in Heating mode
1. Press OPTION at the first time, select the 8°C H by pressing the button or until symbol 8°C H is flashing;
Press OPTION again to activate the 8°C heating function, and
appears on the display. Do it again or
change the mode to deactivate this function.
2. This function enable the setting temperature 8°C when heating.
Timer function
To set the automatic switch-on /off of the air conditioner
For timer on, before proceeding with the time: Switch the conditioner
off (with the key ). program the working mode with the button MODE and the fan
speed with the button FAN.
Timer setting/change/cancel: 1. Press OPTION at the fist time, select the
Timer by pressing the button or until symbol TIMER is flashing;
2. Press OPTION again, the data symbol like be flashing;
and TIMER will
3. To set the timer orchange the timer:
(1) Press the button or to set the expected timer (Increase or
decrease at half-hour intervals) the symbols and TIMER both are
flashing.
(2) Press OPTION or wait for 5 seconds without any operation
to confirm the timer, the pre-setting timer like
and symbol
will be on the display.
To cancel the timer (if TIMER is on)
Figure 1 Timer-on when switch off
Press OPTION or wait for 5 seconds without any operation to
cancel the timer .
Note: All processing should be operated in 5 seconds, otherwise the processing will be cancelled.
Figure 2 Timer-off when switch on
13
ENG
I FEEL function
Press OPTION at the fist time , select the I FEEL by pressing the button
or until symbol I FEEL is flashing; Press OPTION again to activate
the I FEEL function, and I
appears on the display. Do it again to
deactivate this function.
This function enable the remote control to measure the temperature
at its current location and send this signal 7 times in 2 hours to the air
conditioner to enable the air conditioner to optimize the temperature
around you and ensure maximum comfort. It will automatically
deactivate 2 hours later , or indoor temperature exceed the range
0~50°C.
Operating Temperature
The air conditioner is programmed for comfortable and suitable living conditions as below if used outside the conditions, certain safety protection features might come into effect.,
Fix air conditioner:
Temperature
Room temperature
Outdoor temperature
Cooling operating 17°C~32°C
15°C~43°C for T1 Climate 15°C~52°C for T3 Climate
Mode Heating operating
0°C~27°C
-7°C~24°C
Drying operating 17°C~32°C
15°C~43°C for T1 Climate 15°C~52°C for T3 Climate
Inverter air conditioner:
Temperature
Room temperature
Outdoor temperature
Cooling operating
17°C~32°C
15°C~53°C -15°C~53°C For models with low temperature cooling system
Mode Heating operating
0°C~30°C
-20°C~30°C
Drying operating
17°C~32°C
15°C~53°C -15°C~53°C For models with low temperature cooling system
WARNING!
· The unit does not operate immediately if it is turned on after being turned
off or after changing the mode during operation.This is a normal self-
protection action,you need waiting for about 3 minutes.
· The capacity and efficiency are according to the test conducted at full-load
operation(The highest speed of indoor fan motor and the maximum open angle of
the flaps and deflectors are requested.)
14
ENG
INSTALLATION
Important considerations
· The air conditioner you buy must be installed by professional personnel and
the Installation manual is used only for the professional installation
personnel! The installation specifications should be subject to our after-sale
service regulations.
· When filling the combustible refrigerant, any of your rude operations may
cause serious injury or injuries to human body or bodies and object or
objects.
· A leak test must be done after the installation is completed. · It is a must
to do the safety inspection before maintaining or repairing an air conditioner
using combustible refrigerant in order to ensure that the fire risk is reduced
to minimum. · It is necessary to operate the machine under a controlled
procedure in order to ensure
that any risk arising from the combustible gas or vapor during the operation
is reduced to minimum. · Requirements for the total weight of filled
refrigerant and the area of a room to be equipped with an air conditioner (are
shown as in the following Tables GG.1 and GG.2)
The maximum charge and the required minimum floor area
m = (4 m3) x LFL , m = (26 m3) x LFL, m = (130 m3 ) x LFL
1
2
3
Where LFL is the lower flammable limit in kg/m3, R290 LFL is 0.038 kg/ m3, R32 LFL is 0.038 kg/m3.
For the appliances with a charge amount m1 < M = m2: The maximum charge in a room shall be in accordance with the following:
m = 2.5 x (LFL)(5/4) x h x (A)1/2
max
0
The required minimum floor area Amin to install an appliance with refrigerant charge M (kg) shall be in accordance with following:
A = (M/ (2.5 x (LFL)(5/4) x h ))2
min
0
Where:
mmax is the allowable maximum charge in a room, in kg; M is the refrigerant charge amount in appliance, in kg;
Amin is the required minimum room area, in m2; A is the room area, in m2;
LFL is the lower flammable limit, in kg/m3;
h0 is the installation height of the appliance,in meters for calculating mmax or Amin, 1.8 m for wall mounted.
Table GG.1 – Maximum charge (kg)
Category
LFL (kg/m3)
h0 (m)
4
Floor area (m2)
7
10
15
20
30
50
0.6
0.05
0.07
0.08
0.1
0.11
0.14
0.18
R290
0.038
1 1.8
0.08
0.11
0.13
0.16
0.19
0.2
0.3
0.15
0.2
0.24
0.29
0.34
0.41
0.53
2.2
0.18
0.24
0.29
0.36
0.41
0.51
0.65
0.6
0.68
0.9
1.08
0.32
1.53
1.87
2.41
R32
0.306
1 1.8
1.14
1.51
1.8
2.2
2.54
3.12
4.02
2.05
2.71
3.24
3.97
4.58
5.61
7.254
2.2
2.5
3.31
3.96
4.85
5.6
6.86
8.85
15
ENG
Table GG.2 – Minimum room area (m2)
Category
LFL (kg/m3)
R290
0.038
R32
0.306
h0 (m)
0.6 1 1.8 2.2
0.6 1 1.8 2.2
4 0.152kg
1.224kg
Charge amount (M) (kg) Minimum room area (m2)
7
10
15
20
30
0.228kg 0.304kg 0.456kg 0.608kg 0.76kg
82
146
328
584
912
30
53
118
210
328
9
16
36
65
101
6
11
24
43
68
1.836kg 2.448kg 3.672kg 4.896kg 6.12kg
29
51
116
206
321
10
19
42
74
116
3
6
13
23
36
2
4
9
15
24
50 0.988kg
1514 555 171 115 7.956kg 543 196 60 40
Installation Safety Principles
1. Site Safety
· Open Flames Prohibited · Ventilation Necessary
2. Operation Safety
· Mind Static Electricity · Must wear protective clothing and anti-static
gloves · Don`t use mobile phone
3. Installation Safety
· Refrigerant Leak Detector · Appropriate Installation Location
Please note that: 1. The installation site should be in a well-ventilated
condition. 2. The sites for installing and maintaining an air conditioner
using Refrigerant R290 should be free from open fire or welding, smoking,
drying oven or any other heat source higher than 370 which easily produces
open fire; the sites for installing and maintaining an air conditioner using
Refrigerant R32 should be free from open fire or welding, smoking, drying oven
or any other heat source higher than 548 which easily produces open fire. 3.
When installing an air conditioner, it is necessary to take appropriate anti-
static measures such as wear antistatic clothing and/or gloves. 4. It is
necessary to choose the site convenient for installation or maintenance
wherein the air inlets and outlets of the indoor and outdoor units should be
not surrounded by obstacles or close to any heat source or combustible and/or
explosive environment. 5. If the indoor unit suffers refrigerant leak during
the installation, it is necessary to immediately turn off the valve of the
outdoor unit and all the personnel should go out till the refrigerant leaks
completely for 15 minutes. If the product is damaged, it is a must to carry
such damaged product back to the maintenance station and it is prohibited to
weld the refrigerant pipe or conduct other operations on the user’s site. 6.
It is necessary to choose the place where the inlet and outlet air of the
indoor unit is even. 7. It is necessary to avoid the places where there are
other electrical products, power switch plugs and sockets, kitchen cabinet,
bed, sofa and other valuables right under the lines on two sides of the indoor
unit.
16
Special Tools
Tool Name Mini Vacuum Pump Filling Device Leak Detector
Concentration Detector
Pressure Gauge
Fire Extinguisher
ENG
Requirement(s) for Use
It should be an explosion-proof vacuum pump; can ensure certain precision and
its vacuum degree should be lower than 10Pa.
It should be a special explosion-proof filling device; have certain precision
and its filling deviation should be less than 5g.
It should be calibrated regularly; and its annual leak rate should not exceed
10g.
A. The maintenance site should be equipped with a fixed-type combustible
refrigerant concentration detector and connected to a safeguard alarm system;
its error must be not more than 5%.
B. The installation site should be equipped with a portable combustible
refrigerant concentration detector which can realize two-level audible and
visual alarm; its error must be not more than 10%.
C. The concentration detectors should be calibrated regularly. D. It is
necessary to check and confirm the functions before using the concentration
detectors.
A. The pressure gauges should be calibrated regularly. B. The pressure gauge
used for Refrigerant 22 can be used for Refrigerants R290
and R161; the pressure gauge used for R410A can be used for Refrigerant 32.
It is necessary to carry fire extinguisher(s) when installing and maintaining
an air conditioner. On the maintenance site, there should be two or more kinds
of dry powder, carbon dioxide and foam fire extinguishers and that such fire
extinguishers should be placed at stipulated positions, with eye-catching
labels and in handy places.
Selecting the Installation Place
Indoor unit
· Install the indoor unit on a strong wall that is not subject to vibrations.
· The inlet and outlet ports should not be obstructed:the air should be able
to blow all over the room.
· Do not install the unit near a source of heat, steam,or flammable gas.
· Do not install the unit where it will be exposed to direct sunlight.
· Select a site where the condensed water can be easily drained out, and where
it is easily connected to outdoor unit.
· Check the machine operation regularly and reserve the necessary spaces as
shown in the picture.
· Select a place where the filter can be easily taken out.
Mounting plate
Condensed water Sleeve drain pipe Insulating covering Electrical cable Water
drain pipe
17
ENG
Outdoor unit
· Do not install the outdoor unit near sources of heat, steam or flammable
gas.
· Do not install the unit in too windy or dusty places. Do not install the
unit where people often pass.Select a place where the air discharge and
operating sound will not disturb the neighbours.
· Avoid installing the unit where it will be exposed to direct sunlight (
other wise use a protection , if necessary, that should not interfere with the
air flow).
· Reserve the spaces as shown in the picture for the air to circulate freely.
· Install the outdoor unit in a safe and solid place. · If the outdoor unit is
subject to vibration, place
rubber gaskets onto the feet of the unit.
Installation Diagram
Outdoor unit
Minimum space to be reserved (mm) showing in the picture
Indoor unit
Indoor unit
Outdoor unit
The purchaser must ensure that the person and/or company who is to install,
maintain or repair this air conditioner has qualifications and experience in
refrigerant products.
Installation of the Indoor unit
Before starting installation, decide on the position of the indoor and outdoor
units, taking into account the minim- um space reserved around the units
WARNING!
· Do not install your air conditioner in a wet room such as a bathroom or
laundry etc
· The installation site should be 250cm or more above the floor.
18
ENG
To install, proceed as follows:
Installation of the mounting plate
1. Always mount the rear panel horizontally and vertically 2. Drill 32 mm
deep holes in the wall to fix the plate; 3. Insert the plastic anchors into
the hole; 4. Fix the rear panel on the wall with provided tapping screws 5. Be
sure that the rear panel has been fixed firmly enough to withstand the weight
Note: The shape of the mounting plate may be different from the one above, but
installation method is similar .
Drilling a hole in the wall for the piping
1. Make the piping hole (65) in the wall at a slight downward slant to the
outdoor side.
2. Insert the piping-hole sleeve into the hole to prevent the connection
piping and wiring from being damaged when passing through the hole.
Indoors
Outdoors
WARNING! The hole must slope downwards towards the exterior
Note: Keep the drain pipe down towards the direction of the wall hole,
otherwise leakage may occur
Electrical connections-Indoor unit
1. Open the front panel. 2. Take off the cover as indicated in the piciure (
by
removing a screw or breaking the hooks). 3. For the electrical connections,
see the circuit diagram on
the right part of the unit under the front panel. 4. Connect the cable wires
to the screw terminals by
following the numbering ,Use wire size suitable to the electric power input
(see name plate on the unit) and according to all current national safety code
requirements.
WARNING!
· The cable connecting the outdoor and indoor units must be suitable for
outdoor use.
· The plug must be accessible also after the appliance has been installed so
that it can be pulled out if necessary.
· An efficient earth connection must be ensured. · If the power cable is
damaged, it must be replaced by an
authorised Service Centre.
Note: Optional the wires can been connected to the main PCB of indoor unit by
manufacturer according to the model without terminal block.
Front panel Wiring diagram
Terminal block cover
19
ENG
Refrigerant piping connection
The piping can be run in the 3 directions indicated by numbers in the picture
. When the piping is run in direction 1or 3, cut a notch along the groove on
the side of the indoor unit with a cutter. Run the piping in the direction of
the wall hole and bind the copper pipes , the drain pipe and the power cables
together with the tape with the drain pipe at the bottom, so that water can
flow freely. · Do not remove the cap from the pipe until connecting it,
to avoid dampness or dirt from entering. · If the pipe is bent or pulled too
often , it will become stiff
. Do not bend the pipe more than three times at one point. · When extending
the rolled pipe, straighten the pipe by unwinding it gently as shown in the
picture.
Shape the connection pipe YES
NO Extending the rolled pipe
Connections to the indoor unit
1. Remove the indoor unit pipe cap (check that there is no debris inside).
2. Insert the fare nut and create a flange at the extreme end of the
connection pipe.
3. Tighten the connections by using two wrenches working in opposite
directions.
4. For R32/R290 refrigerants, mechanical connectors should be outdoors.
Indoors
Outdoors The connectors should be outdoors
Torque wrench
Indoor unit condensed water drainage
The indoor unit condensed water drainage is fundamental for
the success of the installation. 1. Place the drain hose below the piping,
taking care not to create siphons.
2. The drain hose must slant downwards to aid drainage.
3. Do not bend the drain hose or leave it protruding or twisted and do not put the end of it in water. If an extension is connected to the drain hose, ensure that it is lagged when it passes into the indoor unit.
4. If the piping is installed to the right, the pipes, power
cable and drain hose must be lagged and secured onto
the rear of the unit with a pipe connection.
1. Insert the pipe connection into the relative slot.
NO
2. Press to join the pipe connection to the base.
YES NO
20
Installation of the indoor unit
Covered by vinyl tape
connection cable
refrigerant pipe
insulation sleeve
connection cable 1 (for heat-pump)
Probe cable (for heat-pump)
refrigerant pipe Condensed water drain pipe
Mounting plate
ENG
After having connected the pipe according to the instructions, install the
connection cables. Now install the drain pipe. After connection, lag the pipe,
cables and drain pipe with the insulating material.
1. Arrange the pipes ,cables and drain hose well.
2. Lag the pipe joints with insulating material , securing it with vinyl
tape.
3. Run the bound pipe , Cables and drain pipe through connection cable the
wall hole and mount the indoor unit onto the upper part of the mounting plate
securely.
4. Press and push the lower part of the indoor unit tightly against the
mounting plate.
Installation of the outdoor unit
· The outdoor unit should be installed on a solid wall and fastened securely.
· The following procedure must be observed before co- nnecting the pipes and
connecting cables : decide
which is the best position on the wall and leave enough space to be able to
carry out maintenance easily. · Fasten the support to the wall using screw
anchors which are particularly suited to the type of wall; · Use a larger
quantity of screw anchors than normally required for the weight they have to
bear to aviod vibration
during operation and remain fastened in the same position for years without
the screws becoming loose. · The unit must be installed following the national
regulations.
Outdoor unit condensed water drainage (only for heat pump models)
The condensed water and the ice formed in the outdoor unit during heating
operation can be drained away thro- ugh the drain pipe
1. Fasten the drain port in the 25mm hole placed in the part of the unit as
shown in the picture.
2. Connect the drain port and the drain pipe. Pay attention that water is
drained in a suitable place.
drain port
drain pipe
Electrical connections
1. Remove the handle on the right side plate of outdoor unit. 2. Connect the
power connection cord to the terminal board. Wiring
should fit that of indoor unit. 3. Fix the power connection cord with wire
clamp. 4. Confirm if the wire has been fixed properly. 5. An efficient earth
connection must be ensured. 6. Recover the handle.
wiring diagram on the back of the cover
screw
21
ENG
Connecting the pipes
Screw the flare nuts to the outdoor unit coupling with the same tightening
procedures described for the indoor unit. To avoid leakage, pay attention to
the following points:
1. Tighten the flare nuts using two wrenches. Pay attention not to damage the
pipes.
2. If the tightening torque is not sufficient , there will probably be some
leakage. With excessive tightening torque there will also be some leakage, as
the flange could be damaged.
3. The surest system consists in tightening the connection by using a fix
wrench and a torque wrench.
Bleeding
Air and humidity left inside the refrigerant circuit can cause compressor
malfunction. After having connected the indoor and outdoor units, bleed the
air and humidity from the refrigerant circuit by using a vacuum pump.
Refrigerant Pressure Inspection
Air-returning Low-pressure Range of Refrigerant R290: 0.4-0.6Mpa; Air-
exhausting High-pressure Range: 1.52.0Mpa; Air-returning Low-pressure Range of
Refrigerant R32: 0.8-1.2Mpa; Air-exhausting High-pressure Range: 3.23.7Mpa; It
means that the refrigerating system or refrigerant of an air conditioner is
abnormal if the air-exhausting and airreturning pressure ranges of the
detected compressor exceed the nor mal ranges to a large extent.
connection pipes
flare nuts liquid tap
gas tap
indoor unit gas valve
liquid valve tap
service port nut
protection caps
service port
vacuum pump
Bleeding
The air and humidity left inside the refrigerant circulat- ion can cause
compressor malfunction. After having connected the indoor and outdoor units,
bleed the air and humidity from the refrigerant circulation using a vacuum
pump.
1. Unscrew and remove the caps from the 2 – way and 3-way valves.
2. Unscrew and remove the cap from the service port.
3. Connect the vacuum pump hose to the service port.
4. Operate the vacuum pump for 10 – 15 minutes until an absolute vacuum of 10
mm Hg has been reached.
5. With the vacuum pump still in operation , close the low – pressure knob on
the vacuum pump coupling. Stop the vacuum pump.
6. Open the 2 – way valve by 1/4 turn and then close it after10 seconds.
Check all the joints for leaks using liquid soap or an electronic leak device.
7. Turn the body of the 2-way and 3-way valves. Disconnect the vacuum pump
hose.
8. Replace and tighten all the caps on the valves.
22
ENG 3-way valve diagram
connect to indoor unit
open position spindle
Connect to outdoor unit
Valve core
needle service port cap
Service port nut
2. Turn 8. Tighten
Indoor unit
Refrigerant flow direction
3-way valve
2-way valve
6. Open 1/4 turn
7. Turn to fully open the valve
1. Turn
Valve cap
8. Tighten
7. Turn to fully open the valve Valve cap 1. Turn
8. Tighten
Operation test
1. Wind insulating covering around the joints of the indoor unit and fix it
with insulating tape.
2. Fix the exceeding part of the signal cable to the piping or to the outdoor
unit.
3. Fix the piping to the wall ( after having coated it with insulating tape)
using clamps or insert them into pla- stic slots.
4. Seal the hole in the wall through which the piping is passed so that no
air or water can fill.
Indoor unit test · Do the ON/OFF and FAN operate normally? · Does the MODE
operate normally? · Do the set point and TIMER function properly? · Does each
lamp light normally? · Do the flap for air flow direction operate normally? ·
Is the condensed water drained regularly?
23
Clamps
insulating covering
piping (indoor)
insulating tape
piping gasket
(outdoor)
wall
ENG
Outdoor unit test · Is there any abnormal noise or vibration during operation?
· Could the noise , the air flow or the condensed water drainage disturb the
neighbours? · Is there any coolant leakage? Note: the electronic controller
allows the compressor to start only three minutes after voltage has reached
the system.
INFORMATION FOR THE INSTALLER
MODEL capacity (Btu/h) Lenght of pipe with standard charge Maximum distance between indoor and outdoor unit Additional refrigerant charge Max. diff. in level between indoor and outdoor unit Type of refrigerant 1
1 Refer to the data rating label sticked on the outdoor unit.
Tightening torque for protection caps and flange connection
PIPE
Tightening torque [N x m]
Corresponding stress (using a 20cm wrench)
1/4″ (6)
15 – 20
wrist strength
3/8″ (9.52)
31 – 35
arm strength
1/2″ (12)
35 – 45
arm strength
5/8″ (15.88)
75 – 80
arm strength
9k/12k 5m 15m
20g/m 5m
R410A
18k/24k 5m 15m
30g/m 5m
R410A
Service port nut Protection caps
Tightening torque [N x m] 7 – 9
25 – 30
MODEL capacity (Btu/h) Lenght of pipe with standard charge Maximum distance between indoor and outdoor unit Additional refrigerant charge Max. diff. in level between indoor and outdoor unit Type of refrigerant 1
9k/12k 5m 25m
15g/m 10m R32/R290
1 Refer to the data rating label sticked on the outdoor unit. 2 The total charge amount should under the maximum according to the table GG.1.
Tightening torque for protection caps and flange connection
PIPE
Tightening torque [N x m]
Corresponding stress (using a 20cm wrench)
1/4″ (6)
15 – 20
wrist strength
3/8″ (9.52)
31 – 35
arm strength
1/2″ (12)
35 – 45
arm strength
5/8″ (15.88)
75 – 80
arm strength
Service port nut Protection caps
18k/24k 5m 25m
25g/m 10m R32/R290
Tightening torque [N x m] 7 – 9 25 – 30
24
ENG
Wiring diagram
For different models, the wiring diagram may be different. Please refer to the
wiring diagrams pasted on the indoor unit and outdoor unit respectively. On
indoor unit, the wiring diagram is pasted under the front panel; On outdoor
unit, the wiring diagram is pasted on the backside of the outdoor handle
cover.
Front panel
Wiring diagram
Outdoor handle cover
Wiring diagram
Note: For some models the wires has been connected to the main PCB of indoor
unit by manufacturer without terminal block.
Cable wires specification
ON-OFF Type MODEL capacity (Btu/h)
N
Power supply cable
L
E
N
L
Connection supply
1
cable
2
3
9k
12k
18k
1.0mm2 AWG18 1.0mm2 AWG18 1.0mm2 AWG18
1.0mm2
sectional area
1.0mm2 (1.5mm)2 AWG18 (AWG16)
1.0mm2 (1.5mm)2 AWG18 (AWG16)
1.0mm2 (1.5mm)2 AWG18 (AWG16)
1.5mm2 AWG16 1.5mm2 AWG16 1.5mm2 AWG16
1.0mm2 (1.5mm)2
1.5mm2
1.0mm2
1.0mm2 (1.5mm)2
1.5mm2
1.0mm2
1.0mm2 (1.5mm)2
1.5mm2
0.75mm2
0.75mm2
0.75mm2
0.75mm2
0.75mm2
0.75mm2
0.75mm2
0.75mm2
0.75mm2
24k
2.5mm2 AWG14 H05RN-F
2.5mm2 AWG14 H05RN-F
2.5mm2 AWG14 H05RN-F 0.75mm2 0.75mm2 0.75mm2 0.75mm2 0.75mm2
0.75mm2
25
ENG
INVERTER TYPE R410a MODEL capacity (Btu/h)
N
Power supply cable
L
E
N
Connection supply
L
cable
1
9k
12k
18/22k
sectional area
1.0mm2 (1.5mm)2 AWG18 (AWG16)
1.0mm2 (1.5mm)2 AWG18 (AWG16)
1.0mm2 (1.5mm)2 AWG18 (AWG16)
1.0mm2 (1.5mm)2 AWG18 (AWG16)
1.0mm2 (1.5mm)2 AWG18 (AWG16)
1.0mm2 (1.5mm)2 AWG18 (AWG16)
1.5mm2 AWG16
1.5mm2 AWG16
1.5mm2 AWG16
1.0mm2 (1.5mm)2 1.0mm2 (1.5mm)2
1.5mm2
1.0mm2 (1.5mm)2 1.0mm2 (1.5mm)2
1.5mm2
1.0mm2 (1.5mm)2 1.0mm2 (1.5mm)2
1.5mm2
1.0mm2 (1.5mm)2 1.0mm2 (1.5mm)2
1.5mm2
INVERTER TYPE R32 MODEL capacity (Btu/h)
N
Power supply cable
L
N
Connection supply
(L)
cable
1
9k
1.5mm2 1.5mm2 1.5mm2 0.75mm2 0.75mm2 0.75mm2 0.75mm2
12k
18k
sectional area
1.5mm2
1.5mm2
1.5mm2
1.5mm2
1.5mm2
1.5mm2
0.75mm2
0.75mm2
0.75mm2
0.75mm2
0.75mm2
0.75mm2
0.75mm2
0.75mm2
outdoor
24k
2.5mm2 AWG14 2.5mm2 AWG14 2.5mm2 AWG14 0.75mm2 0.75mm2 0.75mm2 0.75mm2
24k
2.5mm2 2.5mm2 2.5mm2 0.75mm2 0.75mm2 0.75mm2 0.75mm2
power supply
indoor
26
ENG
MAINTENANCE
Periodic maintenance is essential for keeping your air conditioner efficient. Before carrying out any maintenance , disconnect the power supply by taking the plug out from the socket.
Indoor unit
Antidust filters
1. Open the front panel following the direction of the arrow
2. Keeping the front panel raised with one hand, take out the air filter with
the other hand
3. Clean the filter with water ; if the filter is soiled with oil,it can be
washed with warm water (not exceeding 45°C). Leave to dry in a cool and dry
place.
4. Keeping the front panel raised with one hand , insert the air filter with
the other hand
5. Close
The electrostatic and the deodorant filter (if installed) cannot be washed or
regenerated and must be replaced with new filters after every 6 months.
Cleaning the heat exchanger
1. Open the front panel of the unit and life it till its greatest stroke and
then unhooking it from the hinges to make the cleaning easier.
2. Clean the indoor unit using a cloth with the water (not higher than 40°C)
and neutral soap. Never use aggressive solvents or detergents.
3. If the outdoor unit is clogged , remove the leaves and the waste and
remove the dust with air jet or a bit of water.
antidust filter
End of season maintenance
1. Disconnect the automatic switch or the plug.
2. Clean and replace the filters
3. On a sunny day let the conditioner work in ventilation for some hours , so
that the inside of the unit can dry completely.
Replacing the batteries
When: · There is no confirmation beep heard from the
indoor unit.
· The LCD doesn t act.
How: · Take off the cover at back.
· Place the new batteries respecting the symbols + and – .
N.B: Use only new batteries. Remove the batteries from the remote controller when the conditioner is not in operation
WARNING! Do not throw batteries into common rubbish , they should be disposed
of in the special containers situated in the collection points.
27
ENG
TROUBLESHOOTING
Malfunction
The appliance does not operate
Strange odor Noise of running water A fine mist comes from the air outlet A
strange noise can be heard
Insufficient airflow, either hot or cold
The appliance does not respond to commands
The display is off
Switch off the air conditioner immediately and cut off the power supply in the
event of:
Possible causes Power failure/plug pulled out. Damaged indoor/outdoor unit fan motor. Faulty compressor thermomagnetic circuit breaker. Faulty protective device or fuses. Loose connections or plug pulled out. It sometimes stops operating to protect the appliance. Voltage higher or lower than the voltage range. Active TIMER-ON function. Damaged electronic control board. Dirty air filter. Back flow of liquid in the refrigerant circulation. This occurs when the air in the room becomes very cold, for example in the COOLING or DEHUMIDIFYING/DRY modes. This noise is made by the expansion or contraction of the front panel due to variations in temperature and does not indicate a problem. Unsuitable temperature setting. Obstructed air conditioner intakes and outlets. Dirty air filter. Fan speed set at minimum. Other sources of heat in the room. No refrigerant. Remote control is not close enough to indoor unit. The batteries of remote control need to be replaced. Obstacles between remote control and signal receiver in indoor unit. Active LIGHT function. Power failure. Strange noises during operation. Faulty electronic control board. Faulty fuses or switches. Spraying water or objects inside the appliance. Overheated cables or plugs. Very strong smells coming from the appliance.
28
ENG
Error signals on the display
In case of error, the display on the indoor unit shown the following error codes:
Display Description of the trouble
Display Description of the trouble
Indoor temperature sensor fault
Outdoor discharge temperature sensor fault
Indoor pipe temperature sensor fault
Outdoor IPM module fault
Outdoor pipe temperature sensor fault
Outdoor current detect fault
Refrigerant system leakage or fault
Outdoor PCB EEPROM fault
Malfunction of indoor fan motor
Outdoor fan motor fault
Outdoor air temperature sensor fault
Outdoor suction temperature sensor fault
INSTRUCTION FOR SERVICING
1. Check the information in this manual to find out the dimensions of space
needed for proper installation of the device, including the minimum distances
allowed compared to adjacent structures.
2. Appliance shall be installed, operated and stored in a room with a floor
area larger than 4m2. 3. The installation of pipe-work shall be kept to a
minimum. 4. The pipe-work shall be protected from physical damage, and shall
not be installed in an unventilated space if
the space is smaller than 4m2 . 5. The compliance with national gas
regulations shall be observed. 6. The mechanical connections shall be
accessible for maintenance purposes. 7. Follow the instructions given in this
manual for handling, installing, cleaning, maintaining and disposing of the
refrigerant. 8. Make sure ventilation openings clear of obstruction. 9.
Notice:The servicing shall be performed only as recommended by the
manufacturer. 10. Warning: The appliance shall be stored in a well-ventilated
area where the room size corresponds to the room
area as specified for operation. 11. Warning:The appliance shall be stored in
a room without continuously operating open flames (for example
an operating gas appliance) and ignition sources (for example an operating
electric heater). 12. The appliance shall be stored so as to prevent
mechanical damage from occurring. 13. It is appropriate that anyone who is
called upon to work on a refrigerant circuit should hold a valid and up-to-
date certificate from an assessment authority accredited by the industry and
recognizing their competence to handle refrigerants, in accordance with the
assessment specification recognized in the industrial sector concerned.
Service operations should only be carried out in accordance with the
recommendations of the equipment manufacturer. Maintenance and repair
operations that require the assistance of other qualified persons must be
conducted under the supervision of the person competent for the use of
flammable refrigerants. 14. Every working procedure that affects safety means
shall only be carried out by competent persons. 15. Warning: · Do not use
means to accelerate the defrosting process or to clean, other than those
recommended by the
manufacturer. · The appliance shall be stored in a room without continuously
operating ignition sources (for example: open
flames, an operating gas appliance or an operating electric heater. · Do not
pierce or burn. · Be aware that refrigerants may not contain an odour.
Caution: Risk of fire
Operating instructions 29
Read technical manual
ENG
16. Information on servicing: 1. Checks to the area Prior to beginning work
on systems containing flammable refrigerants, safety checks are necessary to
ensure that the risk of ignition is minimized. For repair to the refrigerating
system, the following precautions shall be complied with prior to conducting
work on the system. 2. Work procedure Work shall be undertaken under a
controlled procedure so as to minimize the risk of a flammable gas or vapour
being present while the work is being performed. 3. General work area All
maintenance staff and others working in the local area shall be instructed on
the nature of work being carried out. Work in confined spaces shall be
avoided. The area around the workspace shall be sectioned off. Ensure that the
conditions within the area have been made safe by control of flammable
material. 4. Checking for presence of refrigerant The area shall be checked
with an appropriate refrigerant detector prior to and during work, to ensure
the technician is aware of potentially flammable atmospheres. Ensure that the
leak detection equipment being used is suitable for use with flammable
refrigerants, i.e. non-sparking, adequately sealed or intrinsically safe 5.
Presence of fire extinguisher If any hot work is to be conducted on the
refrigeration equipment or any associated parts, appropriate fire
extinguishing equipment shall be available to hand. Have a dry powder or CO2
fire extinguisher adjacent to the charging area. 6. No ignition sources No
person carrying out work in relation to a refrigeration system which involves
exposing any pipe work shall use any sources of ignition in such a manner that
it may lead to the risk of fire or explosion. All possible ignition sources,
including cigarette smoking, should be kept sufficiently far away from the
site of installation, repairing, removing and disposal, during which
refrigerant can possibly be released to the surrounding space. Prior to work
taking place, the area around the equipment is to be surveyed to make sure
that there are no flammable hazards or ignition risks. “No Smoking” signs
shall be displayed. 7. Ventilated area Ensure that the area is in the open or
that it is adequately ventilated before breaking into the system or conducting
any hot work. A degree of ventilation shall continue during the period that
the work is carried out. The ventilation should safely disperse any released
refrigerant and preferably expel it externally into the atmosphere. 8. Checks
to the refrigeration equipment Where electrical components are being changed,
they shall be fit for the purpose and to the correct specification. At all
times the manufacturer’s maintenance and service guidelines shall be followed.
If in doubt consult the manufacturer’s technical department for assistance.
The following checks shall be applied to installations using flammable
refrigerants: – The charge size is in accordance with the room size within
which the refrigerant containing parts are installed; – The ventilation
machinery and outlets are operating adequately and are not obstructed; – If an
indirect refrigerating circuit is being used, the secondary circuit shall be
checked for the presence of refrigerant; – Marking to the equipment continues
to be visible and legible. Markings and signs that are illegible shall be
corrected; – Refrigeration pipe or components are installed in a position
where they are unlikely to be exposed to any substance which may corrode
refrigerant containing components, unless the components are constructed of
materials which are inherently resistant to being corroded or are suitably
protected against being so corroded. 9. Checks to electrical devices Repair
and maintenance to electrical components shall include initial safety checks
and component inspection procedures. If a fault exists that could compromise
safety, then no electrical supply shall be connected to the circuit until it
is satisfactorily dealt with. If the fault cannot be corrected immediately but
it is necessary to continue operation, an adequate temporary solution shall be
used. This shall be reported to the owner of the equipment so all parties are
advised.
Initial safety checks shall include: -That capacitors are discharged: this
shall be done in a safe manner to avoid possibility of sparking; -That there
no live electrical components and wiring are exposed while charging,
recovering or purging the system; -That there is continuity of earth bonding.
17. Repairs to sealed components 1. During repairs to sealed components, all
electrical supplies shall be disconnected from the equipment being worked upon
prior to any removal of sealed covers, etc. If it is absolutely necessary to
have an electrical
30
ENG
supply to equipment during servicing, then a permanently operating form of
leak detection shall be located at the most critical point to warn of a
potentially hazardous situation. 2. Particular attention shall be paid to the
following to ensure that by working on electrical components, the casing is
not altered in such a way that the level of protection is affected. This shall
include damage to cables, excessive number of connections, terminals not made
to original specification, damage to seals, incorrect fitting of glands, etc.
Ensure that apparatus is mounted securely. Ensure that seals or sealing
materials have not degraded such that they no longer serve the purpose of
preventing the ingress of flammable atmospheres. Replacement parts shall be in
accordance with the manufacturer’s specifications. NOTE: The use of silicon
sealant may inhibit the effectiveness of some types of leak detection
equipment. Intrinsically safe components do not have to be isolated prior to
working on them.
18. Repair to intrinsically safe components Do not apply any permanent
inductive or capacitance loads to the circuit without ensuring that this will
not exceed the permissible voltage and current permitted for the equipment in
use. Intrinsically safe components are the only types that can be worked on
while live in the presence of a flammable atmosphere. The test apparatus shall
be at the correct rating. Replace components only with parts specified by the
manufacturer. Other parts may result in the ignition of refrigerant in the
atmosphere from a leak.
19. Cabling Check that cabling will not be subject to wear, corrosion,
excessive pressure, vibration, sharp edges or any other adverse environmental
effects. The check shall also take into account the effects of aging or
continual vibration from sources such as compressors or fans.
20. Detection of flammable refrigerants Under no circumstances shall
potential sources of ignition be used in the searching for or detection of
refrigerant leaks. Ahalide torch (or any other detector using a naked flame)
shall not be used.
21. Leak detection methods The following leak detection methods are deemed
acceptable for systems containing flammable refrigerants. Electronic leak
detectors shall be used to detect flammable refrigerants, but the sensitivity
may not be adequate, or may need re-calibration. (Detection equipment shall be
calibrated in a refrigerant-free area.) Ensure that the detector is not a
potential source of ignition and is suitable for the refrigerant used. Leak
detection equipment shall be set at a percentage of the LFL of the refrigerant
and shall be calibrated to the refrigerant employed and the appropriate
percentage of gas (25 % maximum) is confirmed. Leak detection fluids are
suitable for use with most refrigerants but the use of detergents containing
chlorine shall be avoided as the chlorine may react with the refrigerant and
corrode the copper pipe-work. If a leak is suspected, all naked flames shall
be removed/ extinguished. If a leakage of refrigerant is found which requires
brazing, all of the refrigerant shall be recovered from the system, or
isolated (by means of shut off valves) in a part of the system remote from the
leak. Oxygen free nitrogen (OFN) shall then be purged through the system both
before and during the brazing process.
22. Removal and evacuation When breaking into the refrigerant circuit to make
repairs or for any other purpose conventional procedures shall be used.
However, it is important that best practice is followed since flammability is
a consideration. The following procedure shall be adhered to: – Remove
refrigerant; – Purge the circuit with inert gas; – Evacuate; – Purge again
with inert gas; -Open the circuit by cutting or brazing. The refrigerant
charge shall be recovered into the correct recovery cylinders. The system
shall be flushed with OFN to render the unit safe. This process may need to be
repeated several times. Compressed air or oxygen shall not be used for this
task. Flushing shall be achieved by breaking the vacuum in the system with OFN
and continuing to fill until the working pressure is achieved, then venting to
atmosphere, and finally pulling down to a vacuum. This process shall be
repeated until no refrigerant is within the system. When the final OFN charge
is used, the system shall be vented down to atmospheric pressure to enable
work to take place. This operation is absolutely vital if brazing operations
on the pipe-work are to take place. Ensure that the outlet for the vacuum pump
is not close to any ignition sources and there is ventilation available.
23. Decommissioning Before carrying out this procedure, it is essential that
the technician is completely familiar with the equipment
31
ENG
and all its detail. It is recommended good practice that all refrigerants are
recovered safely. Prior to the task being carried out, an oil and refrigerant
sample shall be taken in case analysis is required prior to re-use of
reclaimed refrigerant. It is essential that electrical power is available
before the task is commenced. a. Become familiar with the equipment and its
operation. b. Isolate system electrically. c. Before attempting the procedure,
ensure that: – mechanical handling equipment is available, if required, for
handling refrigerant cylinders; – all personal protective equipment is
available and being used correctly; – the recovery process is supervised at
all times by a competent person; – recovery equipment and cylinders conform to
the appropriate standards. d. Pump down refrigerant system, if possible. e. If
a vacuum is not possible, make a manifold so that refrigerant can be removed
from various parts of the system. f. Make sure that cylinder is situated on
the scales before recovery takes place. g. Start the recovery machine and
operate in accordance with manufacturer’s instructions. h. Do not overfill
cylinders. (No more than 80 % volume liquid charge). i. Do not exceed the
maximum working pressure of the cylinder, even temporarily. j. When the
cylinders have been filled correctly and the process completed, make sure that
the cylinders and the equipment are removed from site promptly and all
isolation valves onthe equipment are closed off. k. Recovered refrigerant
shall not be charged into another refrigeration system unless it has been
cleaned and checked.
24. Labelling Equipment shall be labelled stating that it has been de-
commissioned and emptied of refrigerant. The label shall be dated and signed.
Ensure that there are labels on the equipment stating the equipment contains
flammable refrigerant.
25. Recovery When removing refrigerant from a system, either for servicing or
decommissioning, it is recommended good practice that all refrigerants are
removed safely. When transferring refrigerant into cylinders, ensure that only
appropriate refrigerant recovery cylinders are employed. Ensure that the
correct number of cylinders for holding the total system charge are available.
All cylinders to be used are designated for the recovered refrigerant and
labelled for that refrigerant (i.e. special cylinders for the recovery of
refrigerant). Cylinders shall be complete with pressure-relief valve and
associated shut-off valves in good working order. Empty recovery cylinders are
evacuated and, if possible, cooled before recovery occurs. The recovery
equipment shall be in good working order with a set of instructions concerning
the equipment that is at hand and shall be suitable for the recovery of all
appropriate refrigerants including, when applicable, flammable refrigerants.
In addition, a set of calibrated weighing scales shall be available and in
good working order. Hoses shall be complete with leak-free disconnect
couplings and in good condition. Before using the recovery machine, check that
it is in satisfactory working order, has been properly maintained and that any
associated electrical components are sealed to prevent ignition in the event
of a refrigerant release. Consult manufacturer if in doubt. The recovered
refrigerant shall be returned to the refrigerant supplier in the correct
recover cylinder, and the relevant waste transfer note arranged. Do not mix
refrigerants in recovery units and especially not in cylinders. If compressors
or compressor oils are to be removed, ensure that they have been evacuated to
an acceptable level to make certain that flammable refrigerant does not remain
within the lubricant. The evacuation process shall be carried out prior to
returning the compressor to the suppliers. Only electric heating to the
compressor body shall be employed to accelerate this process. When oil is
drained from a system, it shall be carried out safely.
Smart WiFi app user manual can be found at: https://tesla.info/wp-
content/uploads/pdf/TeslaTTWiFiapp.pdf
References
Read User Manual Online (PDF format)