Product Information

Specifications:

  • Models: VC-EA1600SE, VC-EA1800SE
  • Type: Vacuum Cleaner
  • Maximum Power
  • Brand: TOSHIBA
  • Model Number: PN: PKFCBOMPR0010

Product Usage Instructions

Instruction for Your Safety:

Read the manual carefully before using the vacuum cleaner to ensure proper and safe use.

  • Do not modify the unit. Only authorized engineers should disassemble or repair it.
  • Unplug the vacuum cleaner before maintenance.
  • Avoid using near-flammable substances or in wet conditions to prevent electric shock or fire.
  • Do not use the vacuum cleaner with damaged cords or plugs.

Cautions:

  • Supervise children around the appliance to prevent accidents.
  • Avoid using near heat sources to prevent deformation or fire hazards.
  • Properly unplug the vacuum cleaner after each use to avoid electrical issues.

FAQ

  • Q: Can I wash the vacuum cleaner with water?
    A: No, washing the vacuum cleaner with water can cause electric shock. Avoid using it in a bathroom.

  • Q: What should I do if the supply cord is damaged?
    A: If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or a qualified person to avoid hazards.

  • Q: Can children use the vacuum cleaner unsupervised?
    A: The appliance is not intended for use by children without supervision. Always supervise children around the vacuum cleaner.

INSTRUCTION FOR YOUR SAFETY.

  • Read this manual first before using your vacuum to learn the proper use.
  • These instructions in this section should be read and observed well for your safety

WARNING

  • Do not modify. Only an authorized engineer is allowed to disassemble or repair the unit.
  • If the supply cord is damaged, to avoid hazards, it must be replaced by the manufacturer its service agent, or a similarly qualified person.
  • Unplug your vacuum cleaner before beginning maintenance.
  • Do not plug or unplug with A wet hand. a wet hand may cause an electric shock and injury.
  • Do not suck up kerosene, gasoline, or a cigarette stub. That may cause fire.
  • Do not wash with water or use in a bathroom your vacuum cleaner. That may cause an electric shock.
  • Do not remove the power plug from the vacuum cleaner to use for another purpose. The plug is designed for only this model.
  • Do not scratch, damage, modify, bend sharply jerk, or twist a cord, or bundle cords. Do not pinch acord or place a heavy object on cord Damaged cord may cause fire or short-circuiting.
  • Periodically clean the plug. That may cause an electric shock, short-circuiting, or fire due to improper insulation.
  • Do not use your vacuum cleaner when the power supply plug is damaged or the plug of a wall socket is loose. That may cause an electric shock, short-circuiting, or fire.
  • Do not connect other than the power supply written to your vacuum cleaner›s rating plate. That may cause an explosion or fire ion should be read and observed well for your own safety.

CAUTIONS

  • The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities,or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Children should be supervised to ensure that they do not play with the appliance.
  • Hold a plug when reeling the cord. Otherwise, the plug may run wild and hit you.
  • Do not use near an inflammability thing such as gasoline, benzine, thinner, etc. That may cause an explosion or fire.
  • Do not use your vacuum cleaner for long time with the closed exhaust port. Overheating causes a deformation of the unit or fire.
  • Do not use your vacuum cleaner near fire. Heat may deform the vacuum cleaner’s body, so may cause shortcircuiting or fire.
  • When unplugging the vacuum cleaner, always hold the plug and not the power cord. Jerking the cord may damage the cord and cause an electric leak or shortcircuiting.
  • Unplug your vacuum cleaner each time after using it. May cause an injury, burn, or electrical shock or electrical fire due to the deterioration of insulation
  • Do not allow children to play with the vacuum cleaner.

INSTRUCTIONS

  • This vacuum cleaner is for home use. Do not use this vacuum cleaner for any purpose other than cleaning.
  • This vacuum cleaner is not suitable for industrial use,
  • It must not be used outdoors.
  • It must not be used on people or animals.
  • Do not use vacuum cleaner for the following items. Liquid such as water, etc. and wet dust, Sharp objects such as glass, pins, cutlery, etc., Much sand and gravel, etc. Which clog the vacuum cleaner.
  • The bad thing of breathability, such as a plastic wrap.
  • It is strongly recommended to use original dust bads. Using a dust bag different from a specified one may cause mechanical failure.The performance and quality of those bages are not guaranteed.

INSTRUCTIONS

  • Do not press the floor brush too hard against the floor.
  • Slide the brush lightly over the floor.
  • Sliding the brush over sand dust may damage the floor.
  • Do not close your vacuum cleaner Cover forcibly. If dust bag is not inserted, the cover cannot be closed

THROW DUST AWAY

Preparation

  • This vacuum cleaner is for home use.
  • Do not use this vacuum cleaner for any purpose other than cleaning.
  • This vacuum cleaner is not suitable for industrial use,
  • It must not be used outdoors.
  • It must not be used on people or animals.
  • Do not use a vacuum cleaner for the following items. Liquid such as water, etc. and wet dust, Sharp objects such as glass, pins, cutlery, etc., Much sand and gravel, etc. Which clog the vacuum cleaner.
  • The bad thing of breathability, such as a plastic wrap.
  • It is strongly recommended to use original dust bads. Using a dust bag different from a specified one may cause mechanical failure. The performance and quality of those bags are not guaranteed.

How to throw the dust away
General requirements for cloth bag and paper bag
Detach the hose and pull the releasing handle at the front of the dust bag compartment lid upwards, then open the lid.TOSHIBA-VC-EA1600SE-Vacuum-
Cleaner-fig- \(4\)

Note :
Hold the body firmly to open lid. Be careful not to have your hand pinched. Remove the dust bag by bag collar support.(Replace it if it is paper bag).

Requirements for a cloth bag
Slide away the fastener and empty the dust bag if it is cloth bag.

Note:

The cloth bag is washable with water. After washing the cloth bag, dry up by ridding the cloth bag of any moisture.
Finally, fit the cloth bag to the main body.

How to set the dust bag

  • Requirements for cloth bag
    Fold the cloth bag open end and slide the fastener.
    Note:
    If the fastener is not set right in place or the creases do not contact each other at the center,it may cause dust leak from this opening.

  • General requirements for cloth bag and paper bag
    Slide the dustbag into the guide on the dust bag holder. Close the dust bag lid.
    Note:
    Never use the vacuum cleaner without ensuring that a dust bag is in place.The dust box tid will not close if the dust bag is not in its proper place. (please use the paper bag only once).

NAME AND FUNCTIONS OF COMPONENTS

How to fix AccessoryTOSHIBA-VC-EA1600SE-Vacuum-Cleaner-fig-
\(6\)

Fit the accessory holder in an extension pipe Attach three kinds of accessories in the accessory holder.

TOSHIBA-VC-EA1600SE-Vacuum-Cleaner-fig- \(7\)

Power control switch

MODEL VC-EA1800SE
When the vacuum cleaner is turned on by ON/ OFF Switch, the power is MIDDLE and two lights turn on. – Push “+” or “-” button and adjust the power to match cleaning area.

MODEL VC-EA1600SE

  • Move the power control Switch right and left.
    Adjust the power to match the cleaning area.
    For normal use pull out the plug cord up to the yellow mark and maximum to the red mark

  • Always install each one.

  • Unless installed, it may cause trouble

Connecting the hose

  • Attachment:- Insert the hose while pushing a button.
  • Removal:- Detach the hose while pushing the button.
  • Insert the pipe rotation of the hose into the blower outlet. It can blow the dust.
  • Do not bring up the vacuum cleaner with a hose when the pipe rotation is inserted.
  • The vacuum cleaner falls suddenly and you may get injured.
  • Do not use a long time, it will get hot.
  • Do not throw it on a person, garbage may fly toward the person.

Suction regulator

To adjust the suction power, use the sliding suction regulator switch. Move the switch backward to open the orifice. The suction power decreases as the result. By sliding the switch forward, the orifice closes. Subsequently. the suction power by the floor brush increases

Extension PipeTOSHIBA-VC-EA1600SE-Vacuum-Cleaner-fig-
\(11\)

Adjust the length, by pushing the regulation button in the direction of the arrow

Floor brush

  • Switching between carpet and flooring
    • Flooring: Press lever A
    • Carpet: Press lever B
  • Dusting brush for furniture, shelves, books, etc.
    • Crevice nozzle for radiators, crevices, comers, between cushions
  • Accessory holder for attaching to an extension pipe.
    • Upholstery nozzle for cushions and draperies

HOW TO STORE

Permanent Storage

Storage
You may stand in a corner of the room after using a vacuum cleaner.
Insert the stand stopper in the hole on the main body.

Temporary Storage
You may use an instant stand to interrupt using a vacuum cleaner. Insert the stand stopper to the instant holder.

INSTRUCTION
Do not lift the vacuum in the storage position because the stand stopper may suddenly come off and hurt you.

CLEANING

Main unit and accessories

Wipe using dry cloth or cloth soaked with a neutral detergent.
INSTRUCTION
Do not wipe using benzine

Filter

Clean filter
Open the lid and remove the dust bag. This filter is removed by holding it at the top (as shown in the diagram) and pulling it outwards. Remove dust.
Note:
The fiter dose not need replacement. Do not wash with water.

HEAPA Filter

Remove HEPA filter from the unit, then remove dust by patting it gently TOSHIBA-VC-EA1600SE-Vacuum-Cleaner-fig- \(16\)

TROUBLESHOOTING

Do not modify. Only an authorized engineer is allowed to disassemble or repair the unit. Such an act may cause fire, short-circuiting, or injury. When your vacuum Is out of order, contact the product shop.

Permanent StorageTOSHIBA-VC-EA1600SE-Vacuum-Cleaner-fig-
\(17\)

If an abnormality occurs when using the cleaner, disconnect the power plug, and after approx. 15 sec. Connect the plug again to check the operation. if the abnormality still occurs check the following

  • The main unit and cord may be heated with the heat of the motor during operation but it is normal.
  • If you use a vacuum with the dust bag full or long with the crevice nozzle attached, the protector works and stops the operation. Then unplug the vacuum, empty the dust bag and leave your vacuum at a cool place about an hour. Then it will be ready again for use.

SPECIFICATIONS

Model Name VC-EA1600SE &VC-EA1800SE
Maximum Power VC-EA1800SE 1800W VC-EA1600SE 1600W

Rated Power

| VC-EA1800SE 1650W VC-EA1600SE 1550W|
Power supply| AC 220V 50Hz|
Net weight| 5.1 kg|
*Dimensions )L x W H(| 515310x250 mm|
Dust container capacity| 4.5 L|
Cord length**| 5 m|

Suction Control

| Up/ Down Switch VC-EA1800SE Variable Switch VC-EA1600SE|

Accessories

| – Upholstery nozzle

– Dusting brush

– Crevice nozzle

– Accessory holder

|