LifeBasis RN-55 Radon Detector for Home Radon Tester Portable User Manual

May 15, 2024
LifeBasis

LifeBasis RN-55 Radon Detector for Home Radon Tester Portable

LifeBasis-RN-55-Radon-Detector-for-Home-Radon-Tester-Portable-
PRODUCT

Thank you very much for using this product.In order to enjoy the service of this product, please keep and read the instructions carefully.

KEY FEATURES

  1. Measurement indicator. Blinks when the instrument is active.
  2. Low battery level indicator. Change batteries as soon as possible when this icon appears.
  3. “LONG TERM AVERAGE”. Long-term average.
  4. Measuring value.
  5. Unit of measure: pCi/L or Bq / M ).
  6. “SHORT TERM AVERAGE”. Short-term average.
  7. The measurement period for short-term average. Ranges between 1 and 7 days.
  8. “RESET”. Reset button. Use to start a new measurement period. Note: Removes all stored data from the previous measurement.
  9. ‘MODE’. Button to display the number of measurement days since the last reset. Appears on the screen for 20 seconds.
  10. Battery holder for 3x AAA alkaline batteries ( LRO3 ) not included.
  11. Opening of battery cover. Radon sensor vent.

SAFETY

Contact the seller if the product requires service or repairs. The front or back cover must not be opened Avoid subjecting the unit to shock, impact, pressure, vibrations, dust, and moisture.
The unit must not be exposed to direct sunlight for extended periods. Use only AAA alkaline batteries ( LR03 ) not including. Batteries must not be exposed to flame or other high-heat sources. Battery terminals should not be touched and kept free of dust, sand, and liquids.

GETTING STARTED

  1. Firstly, Pull out the plastic tab by the battery lid at the back of the Monitor.
  2. Then the display shows ‘CAL’ (calibration) and counts up to a minimum 50. The monitor self-test in this phase. Duration time less than 30 sec.
  3. The LCD screen shows up to 4 flashing dashes indicating the time left until radon levels are shown. In this phase, data is obtained for an initial radon level calculation. The phase duration depends on radon levels but typically ranges from 6 to 24 hours. The indicator at the top left of the screen flashes when the monitor is active.
  4. Place the monitor in living areas (e.g., bedroom and living room) and in places deemed representative of the air breathed in each living area.

Note:

  1. The radon monitor should not be exposed to direct sunlight or moisture and should be placed at least 50cm above floor level, and at least 150cm from the nearest door, window or air vent.
  2. Don’t move it during measurement.
  3. If the display shows ‘Err ‘ and a number, press RESET, and remove and reinsert the batteries after cleaning its contacts. If the ‘Err’ persists, contact the seller for support.

HOW TO USE THE MONITOR DISCLAIMER

  • The long-term average represents the average radon value for the ongoing measurement, max one year ( updated once every 24 hours ).
  • The short-term average (SHORT TERM AVERAGE) alternates between showing the radon value over the last day (1 updated hourly) and over the last 7 days ( 7 DAYS – updated once every 24 hours ).
  • The long-term average is used to identify any potential health risk.
  • The short-term average is used primarily to see the effect of measures to reduce the radon level-for example by increasing the ventilation.
  • The building can be diagnosed by taking measurements for one week in all living areas, such as living rooms and bedrooms.
  • This should preferably be followed by long-term measurement in the room which has the highest radon value.
  • For long-term measurement periods and action levels, we recommend following the guidelines from the National Radiation Authority

RESET: Press the button to restart the instrument before a new measurement. This operation removes all stored radon data. Remember to note all previous measurements before using the RESET button.

MODE: Press the button to get information on the number of measurement days since the instrument started for the first time or the last RESET operation. This information is displayed on the lower half of the screen for 20seconds before the screen returns to the ordinary display. It is recommended to keep the monitor continuously ON. Replace the batteries when the low battery indicator shows on the display

Note : Upon battery replacement, the instrument is reset and all stored data deleted

DISCLAIMER

The instrument is tested and quality-assured by production.
It meets the accuracy values set out in the specification table.
In the event of incorrect use or operation of the monitor, the manufacturer/seller cannot be held responsible for the losses resulting from it.
If you have any issues with your instrument, please get in touch with us.

We are more than happy to help!

SPECIFICATION

LifeBasis-RN-55-Radon-Detector-for-Home-Radon-Tester-Portable-
FIG1

DISPOSAL & RECYCLING

You must dispose of the Radon monitor properly according to local laws and regulations. Because this machine contains electronic components, it should be discarded and separated from household waste. When it reaches its end life, contact local authorities to learn about disposal and recycling options. You can help protect the environment! Please remember to respect the local regulations, and dispose of the non-working electrical equipment to an appropriate waste disposal center.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals