Thank you for buying this product. Please read this user manual in advance and use the product safely. Please keep this user manual for future reference.

maxell MXES-FR230 Foot Use EMS Sport Device-

Contents of the box  ※ Inside the storage pouch

maxell MXES-FR230 Foot Use EMS Sport Device-Contents| Accessories

maxell MXES-FR230 Foot Use EMS Sport Device-
Accessories

---|---

Introduction

Before reading the instruction manual

  • This instruction manual is subject to change without notice.
  • In order to improve the product, the appearance of some parts or specifications may be changed without notice.
  • Unauthorized duplication of part or all of this instruction manual is prohibited except for personal use.
    Moreover, without permission.

Disclaimer

  • We assume no responsibility for any damage caused by fire, earthquake, action by any third party, other accidents, customer’s intention or fault, incorrect use, or use under other abnormal conditions.
  • The warranty stated in the warranty certificate is all we warrant, and we do not warrant anything except for this warranty including express warranty and implied warranty.
  • We assume no responsibility for any damage caused by any usage not described in this Instruction Manual.
  • This product is not intended for use with equipment and devices related to human life such as medical equipment and devices, nuclear equipment and devices, aerospace equipment and devices, transportation equipment, and equipment and devices which require a high standard of reliability. We assume no responsibility if this product is used for the control systems of these types of equipment and devices and if any injury or fire occurs due to the failure of the product.

Safety caution

Please be sure to observe it for safe use.

| Danger| Danger refers to misuse which might lead to death or serious injury*1 to a high degree.
---|---|---
| Warning

| The warning refers to misuse which might lead to death or serious injury1 .
| Caution| Caution refers to misuse which might lead to injury
2and may cause property damage*3

Example of symbols


| Prohibited actions when handling the product. Graphic symbols representing speci­c instructions are shown in black color in the shape of .
| Caution to ­re, electric shock, high temperature when handling the product. Graphic symbols representing speci­c instructions are shown in black color in the shape of .
| Instruction which must be followed. Graphic symbols representing speci­c instructions are shown in white color in the of ●.

Danger****


Prohibited to use with the following electronic medical equipment

  1. Heart rate regulator implanted in the body.
  2.  Medical equipment to maintain life such as cardiopulmonary machine, etc.
  3.  ECG and other external electronic medical equipment. It may cause medical electronics accidents and impediments to the body.

|
Do not touch leaked liquid
If liquid leaks from this device and gets into the eye, do not rub. Rinse with plenty of clean water immediately and consult a doctor. It may cause blindness.|
Keep batteries out of reach of children Children may swallow the battery. If a battery is swallowed, it may cause death. Consult a doctor immediately for instructions.|
Warning

The following people must consult the doctor before use

  1. People with acute disease.
  2. People with malignant tumors.
  3. People with infectious diseases.
  4. Pregnant women or shortly after delivery.
  5. People with heart failure.
  6. People with fever.
  7. People with anemia.
  8. People with infection, wounds, etc. on the skin surrounding the application area.
  9.  People with abnormal blood pressure.
  10. People who feel an abnormality and need rest.
  11. People with vertebral fracture, sprains, muscle is torn, or similar acute (pain) disease.
  12. People with perceptual disorders resulting from advanced endovascular disorders due to diabetes, etc.
  13. People who have undergone plastic surgery or breast augmentation surgery.
  14.  Except the above-mentioned, who feel an abnormality in their body. It may cause accidents or physical deterioration.

|

The following people must not use the device

  1. People who are consuming or recently consumed alcohol.
  2. People under 18
  3. person who weighs more than 100 kg

|
---|---
If you feel unwell, stop use immediately
This may cause accidents or physical deterioration.| **
Do not use near your heart, head, face, eyes, neck, or vulva
This may cause accidents or physical deterioration.| **

Do not use in highly humid locations such as bathroom
This may cause overheating, electric shock, malfunction, mold or rust.| ****

Do not put into heating appliances such as microwave ovens or pressure cookers
This may cause overheating, smoke or fire.| **
---|---
Do not operate with wet hands
This may cause overheating, shock, malfunction.|
Do not pour liquid or water on the device**
This may cause overheating, smoke, fire, rupture, malfunction or injury.|


Store in a place out of a child’s reach
This may cause accidents or physical deterioration.|
Do not sleep during use
This may cause accidents or injury.|
Do not wear metal accessories such as necklaces during use
This may cause a strong electric shock.|

Do not disassemble or remodel
This may cause overheating, smoke, fire, rupture, liquid leak, malfunction, or injury|
Stop using broken devices
This may cause accidents or injury.| **
Do not use multiple devices at the same time
This may cause accidents or injury.| **

Do not use with other EMS devices
This may cause accidents or injury.| **
Do not use while standing
This may cause accidents or injury.| **

Do not carry out housework involving water, knives, or fire during use
This may cause accidents or injury.| **
Do not short the terminals
This may cause overheating, electric shock, malfunction, or injury.| **

Do not put into the fire
This may cause smoke, fire, or rupture.| ****

Caution

Charge within 10-35°C
Charging out of this temperature range may result in liquid leak, overheating, rupture or malfunction.|
Do not forcibly press the device
This may deform, liquid leak, overheating, fire, rupture, or malfunction.|


Do not use the device on the same body part more than once a day
Even up to 2 different parts per day.|
Do not use continuously
Continuous usage may result in muscular or neuropathic pain.| **
Do not use other electrical devices such as mobile phones during the use
This may cause accidents.| **

Do not use before or whilst driving
This may cause traffic accidents.| ****

  • Do not use and store in locations of high temperature
    This may cause accidents, injury, or malfunction.

  • Do not step on, drop or apply strong shock to the device
    This may deform, liquid leak, overheating, fire, rupture, or malfunction.

  • Do not place flammable or heavy objects on the device, or cover the device with foreign objects such as towels or cushions
    This may cause overheating, fire, rupture, liquid leak.

  • Do not use for purposes other than body training, relaxation
    This may cause accidents or injury.

  • **Do not exercise while using this product
    This may cause injury.
    Precautions for the controller, power adapter, and charging cable**

  • Charge once every 3 months
    The battery will deteriorate and cannot be used.

  • Use only the attached power adapter and charging cable
    This may cause overheating, fire, rupture, or malfunction.

  • Do not use the power adapter or charging cable for anything other than this product
    This may cause overheating, fire, rupture, or malfunction.

  • Securely and fully insert the power adapter
    If the plug is not inserted fully, it may cause electric shock or fire due to accumulated dust.

  • If any abnormality occurs during charging, immediately disconnect the power
    adapter from the outlet This may cause overheating, fire, rupture, or malfunction.
    Precautions for remote control

  • Insert the “+” and “-” poles of the battery correctly
    This may cause rupture, damage, malfunction, or injury due to overheating or leakage.

  • Use specified battery
    This may cause rupture, damage, malfunction, or injury due to overheating or leakage.

  • Do not use a battery that has exceeded the recommended usage period
    It may cause injury or malfunction.

  • Precautions for using the remote control
    The remote control of this product (hereafter, this remote control) uses the 315 MHz frequency, band In this frequency band, it is used for wireless keys of  front doors and remote control key for the car as well as for specific low-power devices such as telemeters, Tele controls, and data transmission.

  1. If you use a cardiac pacemaker, please consult the medical device manufacturer as it uses a specified low-power.
  2. Before using this remote control, make sure that there are no specific low-power devices such as telemeters, Tele controls, and data transmissions nearby.
  3. In the unlikely event that this remote control causes harmful radio wave interference with a specific low-power device, immediately change the location or operate the controller without using the remote control.
  4. If you have any other problems, such as harmful radio wave interference caused by using this remote controller, please contact our “Customer Support Center”.
  5. This remote control has been certified as a specified low power device based on the Radio Law. Therefore, no license is required to use it. However, it is prohibited to disassemble or modify the product or remove the certification label.
  6. Do not use in places where the use of mobile phones or wireless devices is prohibited such as in hospitals or priority seats in trains.

Name of each part

Main Unit

maxell MXES-FR230 Foot Use EMS Sport Device-parts


Controller

maxell MXES-FR230 Foot Use EMS Sport Device-Controller

Remote Control

maxell MXES-FR230 Foot Use EMS Sport Device-Remote
Control

Usage

Remote Control

Remove insulation sheet Pull out the insulation sheet of the remote control.

Controller

Charging (Charge before use )

  • Connect the device and the power adapter with the cable.
  • When the power adapter is plugged into a power outlet, the LED will light up and charging will begin.
  • When charging is complete, the power button will stop flashing and remain lit. Remove the power adapter and charging cable.maxell MXES-FR230 Foot Use EMS Sport Device-parts1

Precautions for charging the controller

  • Charging time is approximately 2.5 hours (charging time varies depending on the remaining battery capacity and the charging environment).
  • The buttons cannot be operated while charging.
  • Please use only the supplied charging adapter and charging cable.
  • Charge in an ambient temperature between 10 ~ 35˚C.
  • The number of times that can be used per charge varies depending on the intensity setting level, usage environment and usage conditions.
  • When storing, please charge once every 3 months. Otherwise, the battery may deteriorate and cannot be used.※The remote control battery cannot be charged.
Number of Training Intensity 15 Approx. 20 times

※Training Mode

When Using

Attach to the main unit
Pay attention to the positions of the snap stud and socket, and attach the controller firmly to the main unit until you hear a click.

maxell MXES-FR230 Foot Use EMS Sport Device-unit

Put your feet on the main unit
Place the product on the floor and put your feet on the main unit while seated.
※If you use the product while standing, you may lose balance due to the intensity of electrical stimulation, and you may fall and get injured.
※ Cannot be used with socks or stockings. Please use the product with barefoot.
※ Wipe off sweat and dirt before use.

maxell MXES-FR230 Foot Use EMS Sport Device- Putt

Turn on the power
Press and hold the power button (approx. 2 seconds) A beep will sound and
the power button will light. When the device turns on, the intensity is preset to level 1 (minimum).
※If your body is not in close contact with the conductive parts, a beeping sound will continue and the power button will blink (approx. 1 minute). If there is no close contact with the body within this 1 minute, the power will
be turned off automatically.
※The power of the controller cannot be turned on by operating the remote control.

maxell MXES-FR230 Foot Use EMS Sport Device-Beep

※Please use the remote control for the following procedures.
Switch modes
By pressing the mode button on the remote control, a sound is emitted from the controller and the mode will
be switched. When the power is turned on, the mode is set to training.
※When you switch the mode, intensity starts from 1 (minimum ).
*The sound of the controller and mode switching

maxell MXES-FR230 Foot Use EMS Sport Device- Switch
modes

Mode and Features| Training Steps

| Stimulation
Frequency
Type| Intensity
Level
Selection| Training Time

---|---|---|---|---
Training mode

A variety of stimuli can effectively train the wide range of muscles of the legs and hips

| 20 Steps| 25 Types| 15 Level| approx. 1 0 mins
Relaxation Mode

It provide a mild and comfortable stimulus to the feet

| 14 Steps| 17 Types| 15 Level| approx. 1 0 mins
Sole Relaxation Mode

It provides a comfortable tapping feeling

to the feet

| 3 Steps| 3 Types| 15 Level| approx. 1 0 mins
Calf Relaxation Mode

It provide a comfortable massaging effects to the calf

| 3 Steps| 3 Types| 15 Level| approx. 1 0 mins

Adjusting intensity

  • Adjust by pressing the intensity selection buttons “+” and “-” on the remote control. There are 15 levels of electrical stimulation.

  • When you operate the “+” or “-” button, it makes a beeping sound.

  • When the intensity reaches 15 (maximum) or 1 (minimum), it gives a beeping sound.
    ※When the power is turned on, the intensity level is 1 (minimum).

  • You can also use the controller to switch modes and adjust the intensity. < Switch modes with the controller>

  • Pressing the power button (short press) while the power button is lit will cause the controller to make a sound and switch the mode. When the power is turned on, the mode is set to training.
    < Adjust intensity with the controller>

  • While the power button is lit, press the controller intensity selection buttons “+” and “-” to adjust. There are 15 levels of electrical stimulation.

  • When you operate the “+” or “-” button, it makes a beeping sound.

  • When the intensity reaches 15 (maximum) or 1 (minimum), it makes beeping sounds.
    ※When the power is turned on, the intensity level is 1 (minimum).
    ※The intensity selection buttons of the controller are an electrostatic type, so they may not work in the following cases.

  • Pressing with your nails

  • Wearing adhesive plaster

  • Operating with dry fingers

  • A sticker on the controller

  • Controller is dirty

Usage example

  • The following usage is recommended. (Be sure to use while sitting or lying down)
    ※If you use the product while standing, you may lose balance due to the intensity of electrical stimulation,
    and you may fall and get injured.
    ※If your body is not in close contact with the conductive parts, a beeping sound will continue, and the power button will blink (approx. 1 minute). If there is no close contact with the body within this 1 minute, the power will be turned off automatically.
    ※Wipe off sweat and dirt before use.

Recommended Usage| Vertical Use

| Horizontal Use

| Using for Calves
---|---|---|---
maxell MXES-FR230 Foot Use EMS Sport Device-Vertical
Use| maxell MXES-FR230 Foot Use EMS Sport
Device-Horizontal Use| maxell MXES-FR230
Foot Use EMS Sport Device-Calves
Objective| Stimulation to the entire lower leg

Training soles, calves, and anterior

shin muscles

| Stimulation to the soles of the feet Caring for your feet while relaxing| Stimulate your calves

while relaxing

Recommended

Modes

| Training| Relaxation Sole Relaxation| Relaxation

Calf Relaxation

Recommended Usage| For Thighs| For Hip
maxell -Thighs|
Objective| Stimulate and train thegluteus maximus muscles| Stimulate and train the gluteus maximus muscles
Recommended Modes| Training| Training

❾Training finishes
※The power will automatically turn off in approx.10 minutes in any of the modes.

  • To turn off the power during use, press and hold the power OFF button of the remote control to OFF (approx. 2 seconds). Alternatively, press and hold the power button on the controller (approx. 2 seconds). As it makes the beeping sounds, the light of the power button will be turned off and the power will be turned off.
  • After starting the operation, approx.10 mins, it will have a beep sound and then automatically turn OFF.

Caution

  • If you feel pain or numbness during use, switch off the device, change the position of your feet or sitting position, and then try again.
  • Do not forcibly increase the intensity.
  • In the beginning, please start the training from a low-intensity level (level 1, etc.), and gradually increase the intensity after getting used to electrical stimulation.
  • Traning steps will be switched automatically and do not support manual operation.
  • When the device is stopped during the training, the next training will start from the beginning.
  • Use within 10-35°C.
  • If the power button does not light on or the electrical stimulus cannot be felt, the battery may be exhausted. Please charge the controller.
  • Be sure to disconnect the charging cable before use.

If you feel pain during electrical stimulation

  • Wet 2 pieces of non-woven fabric or thin cloths with water, wring them well,
    place a piece on each conductive part of both sides of the main unit.
    ※The controller and the main unit are not waterproof. Please do not allow the controller or the main unit to get wet.
    ※Please do not use wet tissues with chemicals (for face cleansing, makeup removing, etc).
    ※When you placing the non-woven fabric, please do not let it touch the controller or the snaps.

  • Do not use the product in the following ways.
    The left and right non-woven fabrics are in contact
    Using one piece of non-woven fabric
    Using non-woven fabrics in layers. Using dry non-woven fabric

maxell MXES-FR230 Foot Use EMS Sport Device-non-woven

  • Even after changing the position of your feet or the sitting position or using a non-woven fabric, you still feel strong
    electrical stimulation, stop using this product immediately.

Storage Method

  • After use, wipe off sweat and moisture, remove the controller from the main unit. Fold the main unit, and store it in the storage pouch with the controller, remote control, charging cable, and power adapter. If you leave the product without wiping off sweat and moisture, the product life may be shortened.
  • Make sure that the power is not turned on, and store it away from high temperatures, high humidity, direct sunlight, and dusty places.
  • When not in use for a long period of time, charge the controller and remove the battery from the
    remote control for storage.
    Please charge the battery once every 3 months. Otherwise, the battery may deteriorate and cannot be used.

Maintenance

Never carry out maintenance during charging and ensure the power supply is off.
Be sure to the power off and remove the controller from the main unit.
Maintenance of main unit, controller, and remote control

  • Please use a dry and soft cloth to wipe away the dirt on the device.

  • For severe dirt, please use a damp soft cloth to wipe away the dirt on the device gently. Please squeeze out water from a wet cloth before wiping.
    Caution

  • This product is not waterproof. Please do not splash water on the main unit, controller, and remote control.

  • Do not wipe with chemicals such as benzene, thinner, or alcohol.

  • If the product is used without being cleaned or stored for a long period of time, it may cause
    performance deterioration and malfunction. Regular maintenance is recommended.
    Replace Battery of the remote control
    If the LED on the remote control does not light, or if the remote control does not respond when you point it at the controller, the battery may be exhausted. Replace with new batteries.
    ※The included battery is for trial use. The battery life may be short.
    ※The remote control battery cannot be charged.

Open the battery lid
Use a coin etc. to open the battery lid.
※Be careful not to lose the battery lid.

maxell MXES-FR230 Foot Use EMS Sport Device-lid
Take out the battery
Put your finger in the recess, press from the bottom, and take out the battery.

maxell MXES-FR230 Foot Use EMS Sport Device-lid2
Insert a battery
Insert the battery with the “+” mark facing up.
Battery Used Button type lithium battery CR2032
( Recommendation: Maxell Manufacturer )
※Make sure that the battery is installed securely.

maxell MXES-FR230 Foot Use EMS Sport Device-lid3
Close the battery lid
Use a coin etc. to close the battery lid.
※Make sure that the battery lid is tightly closed. If the battery cover is not closed securely, the remote control may not operate.

maxell MXES-FR230 Foot Use EMS Sport Device-lid4
Caution

  • Do not insert the battery with the “+” and “-” poles in the incorrect orientation.
    This may cause rupture, damage, malfunction, or injury due to overheating or leakage.

  •  If a battery or battery lid is swallowed, contact a doctor immediately for instructions.

  • Be sure to replace the battery with a new one.

  • For the removed battery, cover the “+” and “-” poles with adhesive tape to insulate it, then dispose of it according to the disposal rule of the district where you live (city).

Troubleshooting

Problem Cause Solution
Cannot power on (controller) Controller battery level is low Charge the

controller
The time to press and hold the power
the button is not long enough| When the power button is pressed for approx.
2 seconds, a beep sounds and the power turns
on
Trying to turn on the power with the
remote control| The power cannot be turned on with the
remote control. Press and hold the power
button on the controller (approx. 2 seconds)
The beeping does not stop
(controller )| The controller and the main unit are
not connected| Please securely attach the controller to the
main unit
Not into:iv contact with the body| Please adjust the position where you put your fee or site   swoon
Extremely dry skin| use water to moisten your rim end try again
Device cannot
operate (controller,
main unit)| Ccesedie battery is exhausted| Charge the controller
Power turns on renomaucaly after certain time| This device will stop after a mode approx.
10 mins
Cannot feel the
training
Electrical stimulation is
weak, and does not
increase| Not in close contact with the body| Please adjust the position where you put your
feet or sitting position
Confront. Battery level is low| Chzege the Controller
Intensity setting is low| Press “+” on the intensity selection button to
increase the intensity
r: is in a age rent mode

le

| Select the mode refeerrg to P 9 0 Exarrpit 44 use
Extreme* dry thin| use water to moisten your skin and try again
Remote control battery is exhausted| Pialtat.tha remote “rater a bailer/ wah a
Sensation is too strong or kith peon..| ireenety settee) Is !ugh| Press “-” on the intensity selection button to
decrease the intesity
no: inCIO:iv contact withthe body| Please adjust the position where you put your
feet or where sitting position
Phrysgd peed-sirs/lion that makes you feel stngeue to electrical stimutoon| Please refer to P.10 “If you feel pain during
the electrical stimulation”, wet 2 pieces of nonwoven fabric or thin cloths with water, wring them well, place a piece on each conductive part of both sides of the main
unit
used tM<MFy| Fa the sane pot of body. use once a day
unable to <huge Conootlerl| The charging cable is nth inserted properly| Securery inset the posser adapter to the end
t1Ddtes not Ighe iRemot«ontniT| Rteneee control testa” k, exhausted| Replacethe remote ccegfeel s battery witha newbattery
Remote control
cannot operate| Radio waves from the remote
control do not reach the controller| Alm the ttifrotic tonuoi at slit commit and operate. Please operate the remot«not closer to the controller
The remote control battery is exhausted| ReViste the remote critter listener vitth a w
Controller battery level is exhausted| Charge the CO–4101kt
Try to turn ON the power path the remote control| The power cannot be turned on with the
remote controll. Press and hold the power
button on the controller (approx. 2 seconds)

Device disposal

Regarding controller
Caution: Regarding disposal of rechargeable batteries in Japan
The controller of this product is equipped with a lithium-ion battery (rechargeable battery).
Rechargeable batteries can be recycled. Please do not remove this rechargeable battery by yourself,
please contact our “Customer Support Center”. For the collection/recycling of rechargeable batteries and cooperating organization of recycling, please refer to the JBRC website.
Regarding remote control
When disposal, be sure to remove the battery (coin-type lithium battery) from the remote control, cover the “+” and “-” poles with adhesive tape to insulate it,  then dispose of it according to the disposal rule of the district where you live (city).
Regarding main unit, power adapter, charging cable
Please dispose it according to the disposal rule of the district of where you live (city).

Specification

Device

(included controller)

| Dimension| W360 x H340 x D22mm (excluding protrusions)
---|---|---
Weight| Approx. 150g
Controller| Battery| Lithium-ion battery 3.7V 120mAh
Operation Time| Each mode approx. 10mins
**Accessories**| Remote Control| Dimension| W37xH70xD11mm (excluding protrusions)
Weight| Approx. 14 g (without battery)
Battery| Coin type battery ( CR2032 )
Transmission Frequency| 315 MHz
Transmission Distance| Approx. 3m (sight distance)
Trial Battery| Coin Type Battery (CR2032)| Installed on the remote control
Power Adapter| Input| AC 100-240V 50 / 60Hz
Output| DC5V / lA Max.
Charging Cable| Length| Approx. 50cm
Storage Pouch| Dimension| W35xH20cm

Antibacterial effect

Part name|  Main unit| The part performed
antibacterial treatment|  Conductive part
---|---|---|---
Test method| Based on
JIS Z 2801-2012| Antibacterial method| Kneaded into conductive
silicone rubber
Testing organization| Guangzhou Microbiology Research Institute (China)

Maxell, Ltd.
30-13 Motoyoyogi-Cho, Shibuya-Ku, Tokyo 151-8527