TruGroove ID-49 Perimeter Fixtures Drywall Ceiling Trim Instruction Manual

May 15, 2024
TruGroove

TruGroove ID-49 Perimeter Fixtures Drywall Ceiling Trim

Product Information

Product Specifications

  • Product Name: TruGroove Perimeter fixtures
  • Installation Type: Drywall ceiling installation
  • Mounting Options: Trim and Trimless
  • Power Feed Locations: 2 per module

Product Usage Instructions

Product Usage Instructions – Trim Installation

  1. Review all instructions, including fixture/sensor wiring and mechanical details, before starting installation.
  2. Identify the components required for trim installation: Flat End Set, Wall Rail, Joiner Kit, Variable End Set, Trim Flange, and Tools Required.
  3. Ensure installation is following national and local building and electrical codes.
  4. Prepare the ceiling framing and follow the specified dimensions for wall rails and mounting bracket/cable installation.
  5. Attach the wall rails to wall studs at the specified height from the Above Finished Floor (AFF) dimension.
  6. Install the TruGroove Perimeter modules following layout drawings or row configuration documents for module length and mount distances.

Product Usage Instructions – Trimless Installation

  1. Review all instructions before starting installation.
  2. Identify the components required for trimless installation: Wall Rail, Flat End Set, Joiner Kit, Variable End Set, Tools Required, and Trimless Flange.
  3. Ensure installation is per national and local building and electrical codes.
  4. Prepare the ceiling framing based on the provided diagrams for standard drywall or textured wall installations.
  5. Make sure to provide the required regress for your job based on the TruGroove Perimeter fixture modules above plenum heights.
  6. Mount the wall rails at the specified height from the AFF dimension and follow the framing requirements.

Frequently Asked Questions (FAQ)

  • Q: What tools are required for installing TruGroove Perimeter fixtures?
    A: The tools required include those specified in the manual for both trim and timeless installations. Make sure to have them ready before starting the installation process.

  • Q: How many power feed locations are available per module?
    A: There are two power feed locations available per module for both trim and timeless installations.

  • Q: What are the mounting options for TruGroove Perimeter fixtures?
    A: TruGroove Perimeter fixtures can be installed with either trim or trimless mounting options based on your preference and design requirements.

System Overview

These instructions review how to install TruGroove Perimeter fixtures. Modules can be installed as individual standalone units, or they can be joined together to create continuous runs. The graphics below show the components required to install a typical run of TruGroove Perimeter fixtures.

IMPORTANT:
Read all instructions including fixture/sensor wiring AND mechanical details before beginning installation.

TruGroove-ID-49-Perimeter-Fixtures-Drywall-Ceiling-Trim-fig-
\(1\)

These instructions review how to install TruGroove Perimeter fixtures. Modules can be installed as individual standalone units, or they can be joined together to create continuous runs. The graphics below show the components required to install a typical run of TruGroove Perimeter fixtures.

IMPORTANT:
Read all instructions before beginning installation.

TruGroove-ID-49-Perimeter-Fixtures-Drywall-Ceiling-Trim-fig-
\(2\)

Ceiling Preparation/Framing Requirements

TruGroove-ID-49-Perimeter-Fixtures-Drywall-Ceiling-Trim-fig-
\(3\)

Typical commercial ceiling framing components are shown in the diagram above. Refer to layout drawings or row configuration documents for a module or run lengths. Refer to page 4 for the required framing opening. NOTE: The above- finished floor dimension (AFF) is required and used for framing and wall rail installation reference.

  • IMPORTANT: For framing module ends, add 1/4” to run or module length at each end.
  • IMPORTANT: Deep channel track (by others) must be installed and framed to the required opening shown.
  • IMPORTANT: These instructions cover ceiling drywall thickness of 1/2” – 5/8”.

Installation Instructions

  1. Ceiling Preparation (Flat Wall)
    Ceiling preparation covers ceiling framing, attachment of wall rails and mounting bracket/cable installation. The above diagram covers all required dimensions for standard drywall installation. NOTE: Framed opening size must be followed for proper fit.
    Ceiling Preparation (Textured Wall)
    Optional: Textured walls. The above diagram covers all required dimensions for standard drywall installation with a textured wall. IMPORTANT: To ensure a proper fit, blocking (by others) must be the same as wall texture.

  2. Wall Rail Installation 4” Regress
    Tr groove perimeter fixture modules are available in two different above- plenum heights. Refer to the layout drawings for the required regress for your job. Standard 4” regress is shown in the above diagram. Attach wall rails (hardware by others) to wall studs. at a specified height from the AFF dimension.
    Wall Rail Installation 2” Regress
    TruGroove perimeter fixture modules are available in two different above- plenum heights. Refer to the layout drawings for the required regress for your job. Optional 2” regress is shown in the above diagram. Attach wall rails (hardware by others) to wall studs. at a specified height from the AFF dimension.TruGroove-ID-49-Perimeter-Fixtures-Drywall-Ceiling-Trim-fig-
\(4\)

  3. Mount Installation
    Refer to page 1 for the typical suspension cable location on each fixture housing. To install the 1st module, two brackets and suspension cables are required. When joining luminaires, only one bracket and suspension cable are required for each joining module.

  4. Power Feed Preparation
    Determine required power feel locations. Refer to page 1 for typical power feed locations for each housing. Prepare the power feed drop conduit and suspend it close to the required location. The attachment to the fixture module is shown in step 8.

  5. Fixture Installation
    Lift the fixture module past the ceiling plane, Tilt as shown and engage the housing hook on the wall rail.

  6. 6. a Fixture Installation – Ambient
    Insert suspension cables installed in step 3 through cable grippers inside the fixture housing. IMPORTANT: Ensure suspension cables are vertical. Level the fixture and trim the excess cable to 1” below the fixture. Tuck the remaining cable inside the fixture.TruGroove-ID-49-Perimeter-Fixtures-Drywall-Ceiling-
Trim-fig- \(5\)

  7. 6b. Fixture Installation – Graze
    Remove the graze packaging insert from both ends of the housing. Engage housing on wall rail. Insert suspension cables installed in step 3 through cable grippers inside the fixture housing. Pull cables through and refer to the next step for levelling instructions.

  8. Fixture Installation- Graze
    To adjust the fixture level, support the bottom of the housing and release the cable gripper plunger shown. The cable will slide freely and allow fine-tuning of the housing position. Repeat the process at each cable gripper location using the same procedure to ensure housing is level.

  9. Power Feed Connection
    Break 7/8” knockout at end of housing at required power feed location. Install conduit connector (by others) and complete electrical connections. For a row end, tuck wires inside the wiring cavity and follow endplate instructions starting in step 13.

  10. Fixture Joining
    Slide the dimpled side of the jointer bracket approximately 1 inch inside the top channel of module 1. Tap biscuit aligners just past halfway inside module 2 as shown.TruGroove-ID-49-Perimeter-Fixtures-Drywall-Ceiling-Trim-fig-
\(6\)

  11. Fixture Joining
    Secure the joiner bracket to module 1 with the screw provided. Slide module 2 on the rail and engage on the free end of the joiner bracket. Complete all required electrical connections and tuck all wires inside both wiring cavities.

  12. Fixture Joining
    IMPORTANT: Before sliding fixtures together, make sure all wires are properly tucked inside fixture wiring cavities. Slide fixture housings together and attach a second joiner bracket screw.

  13. 12a. Trim Flange Installation

    • 12b. Trimless Flange InstallationTruGroove-ID-49-Perimeter-Fixtures-Drywall-Ceiling-Trim-fig- \(7\)
  14. Flat End Installation
    Remove the lens from the end module(s). Set aside and keep in a clean area until the end of the installation.

  15. Flat End Installation
    At tach upper endplate to housing with screws provided.

  16. Flat End Installation
    At module ends, trim deep channel track as shown to allow lower endplate installation later.

  17. Variable End Installation
    After fixture modules have been installed and levelled, measure the distance between the wall and the fixture end. Trim variable endplate as required. INSTALLATION TIP: Before the next step, attach 2 screws shown above to the housing. Fully tighten then back off 1/2 turn.TruGroove-ID-49-Perimeter-
Fixtures-Drywall-Ceiling-Trim-fig- \(8\)

  18. Variable End Installation
    After the variable endplate has been trimmed to size, slide the endplate toward the wall guiding open slots to-wards screws installed in step 16. Hook slots on screws and push towards the wall.

  19. Variable End Installation
    Check that the endplate edge is flush with the housing and attach the final screw to lock it in place.

  20. Panel Installation
    Starting at one end, align the first grid panel with the end of the housing and lift in position.

  21. Panel Installation
    Insert washer inside rectangular panel slot. Attach to the housing using the screw provided. Fully tighten the screw then back of 1/4 turn to allow the panel to glide up and down without play.TruGroove-ID-49-Perimeter-Fixtures-
Drywall-Ceiling-Trim-fig- \(9\)

  22. Panel Installation
    Repeat the screw and washer installation procedure along the panel length as shown. Repeat panel installa-tion to complete the required run.

  23. Panel Installation
    After installation, panels will rest as shown and be ready for trim flange installation.
    IMPORTANT: As panels are not accessible after drywall installation, ensure all panels can glide up and down freely without play. Adjust as needed.

  24. Variable Panel Installation
    Raise variable and full-size panels to the housing level. Align the full-size panel with the end of the housing and overlap the variable panel on top. Support in position for attachment.

  25. Variable Panel Installation
    Follow the instructions in step 20 and secure both panels together to housing as shown. Fully tighten screws and back off 1/4 turn to allow panels to glide freely without play. NOTE: When installed, the variable panel will match the length of the variable endplate installed in steps 16-18.TruGroove-ID-49
-Perimeter-Fixtures-Drywall-Ceiling-Trim-fig- \(10\)

  26. Drywall Installation
    NOTE: These instructions cover drywall thickness of 1/2” – 5/8”. Install drywall and trim flush to the framing opening.

  27. Lower Endplate Installation
    Engage the mid endplate inside a groove in the lower endplate Use washers (x2) and the screw provided to join togeth-er as shown. Attach the endplate to trim the flange end with the screw provided.
    IMPORTANT: Before tightening the screw, make sure the endplate and flange are aligned.

  28. Trim Installation
    Starting at one end, raise the trim flange to the ceiling opening and guide against the outside edge of the fixture endplate installed in steps 14-15.

  29. Trim Installation
    Lift trim flange towards ceiling making sure to engage panel edge into trim flange groove.TruGroove-ID-49-Perimeter-Fixtures-Drywall-Ceiling-Trim-fig-
\(11\)

  30. Trim Flange Installation
    Align the end of the trim flange with the upper fixture endplate. Using a right-angle driver, secure the trim flange to the deep channel track with wafer head screws (by others).

  31. Trim Flange Installation
    For proper attachment and alignment of trim flange sections, install screws at all hole locations.

  32. Trim Flange Installation
    Fr om inside ceiling opening, secure the lower endplate to the upper endplate using the screw provided.

  33. Trim Flange Installation
    For a wall end or wall-to-wall installation, install the first trim flange section as shown in steps 29-30. To join trim flange sections, follow steps 33-34. Measure and cut the last section of the trim flange to fit at the other wall end.TruGroove-ID-49-Perimeter-Fixtures-Drywall-Ceiling-Trim-fig-
\(12\)

  34. Trim Flange Installation
    Tap the biscuit aligner just past halfway inside the trim flange as shown.
    INSTALLATION TIP: When closing a run, tap the biscuit aligner more than halfway to create sufficient clearance for the last trim flange section.

  35. Trim Flange Installation
    To attach the next piece of the trim flange, align the biscuit aligner with the groove, slide the trim flange against the installed trim flange and attach it with screws as shown in steps 29-30. Repeat the steps to install all remaining trim flange sections.

  36. Lens Installation
    Re-install the lens removed in step 13. For the graze version shown above, position the textured side of the lens away from the wall. INSTALLATION TIP: Start on one end, squeeze the lens together and insert it into the housing. Gently push the lens bottom-up one inch at a time until done.TruGroove-ID-49
-Perimeter-Fixtures-Drywall-Ceiling-Trim-fig- \(13\)

  37. Flat End Installation
    Install flat endplate and back plate to housing with screws provided. Fully tighten screws then back off 1/2 turn. Ensure the flat endplate can glide up and down without play.

  38. Flat End Installation
    After installation, the lat endplate will rest as shown and be ready for timeless flange installation. IMPORTANT: As panels are not accessible after drywall installation, ensure all panels can glide up and down freely without play. Adjust as needed.

  39. Panel Installation
    Sta ring at one end, align the first grid panel with the end of the housing and lift in position.

  40. Panel Installation
    Insert washer inside rectangular panel slot. Attach to the housing using the screw provided. Fully tighten the screw then back of 1/4 turn to allow the panel to glide up and down without play.TruGroove-ID-49-Perimeter-Fixtures-
Drywall-Ceiling-Trim-fig- \(14\)

  41. Panel Installation
    Repeat the screw and washer installation procedure along the panel length as shown. Repeat panel installa-tion to complete the required run.

  42. Drywall Installation
    NOTE: These instructions cover drywall thickness of 1/2” – 5/8”. Install drywall and trim flush to the framing opening.

  43. Flat End Installation
    Rai se perforated endplate to the ceiling plane. Slide up between drywall and flat endplate.

  44. Flat End Installation
    From the inside ceiling opening, align holes with a flat endplate and attach with screws (x2) provided. Lift against drywall and secure to structure using drywall screws (by others).TruGroove-ID-49-Perimeter-Fixtures-Drywall-
Ceiling-Trim-fig- \(15\)

  45. Trimless Flange Installation
    Lift the timeless flange towards the ceiling making sure to engage the panel edge into the timeless flange groove.

  46. Trimless Flange Installation
    Align the ends of the timeless flange with the perforated endplate. Push timeless flange tight against drywall and attach to the structure using drywall screws (by others).

  47. Trimless Flange Installation
    For a wall end or wall-to-wall installation, install the first rimless flange section as shown in steps 43-44. To join trimless flange sections, follow steps 47-49. Measure and cut the last section of the trimless flange to fit at the other wall end.

  48. Trimless Flange Installation

    • Tap the biscuit aligner just past halfway inside the trim-less flange as shown.
    • INSTALLATION TIP: When closing a run, tap the biscuit aligner more than halfway to create sufficient clearance for the last timeless flange section.TruGroove-ID-49-Perimeter-Fixtures-Drywall-Ceiling-Trim-fig- \(16\)
  49. Trimless Flange Installation
    To attach the next timeless flange section, align the biscuit aligner groove and slide the timeless flange tightly against the installed section.

  50. Trimless Flange Installation
    Secure trimless flange to structure using drywall screws as shown in step 44. Repeat the steps to install all remaining trimless flange sections.

  51. Drywall Mudding/Finishing
    Mud, sand and paint the ceiling as required.TruGroove-ID-49-Perimeter-
Fixtures-Drywall-Ceiling-Trim-fig- \(17\)

This equipment has been tested and found to comply with the limits for a Class A digital device, under part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interreference when the equip- ment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used by the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Sensor in Rows

Single Sensor Controlling Whole Row

  1. Purple & brown (or purple & grey/pink) control wires MUST be connected between fixtures.
    Note:
    A maximum of 8 drivers can be wired to 8 sensors; confirm the fixture driver count with the factory.TruGroove-ID-49-Perimeter-Fixtures-Drywall-Ceiling-
Trim-fig- \(18\)
    Multiple Sensors Controlling Separates Zones in a Row

  2. Purple & brown (or purple & grey/pink) control wires MUST NOT be connected between zones.
    Notes:

    • A maximum of 8 drivers can be wired to one sensor; confirm the fixture driver count with the factory.
    • Only one sensor is allowed on a wired zone. (Sensors can be paired together wirelessly via a mobile app).TruGroove-ID-49-Perimeter-Fixtures-Drywall-Ceiling-Trim-fig- \(19\)

Sensor Spacing

  • For correct operation, the sensor should be placed a minimum distance of 8ft apart.
  • Wireless sensors should be placed no further than 40ft apart for good wireless signal connection.TruGroove-ID-49-Perimeter-Fixtures-Drywall-Ceiling-Trim-fig- \(20\)

Important Consideration When Using Sensor in a Row

  • For fixtures with wireless sensors (CS, SB or RA options):
    • DO NOT connect fixture purple and brown (or purple & grey/pink) control wires to an external dimming switch.
    • Fixture mains wiring should not be connected to a circuit with an external on/off switch.
  • For the best aesthetic condition, place sensors at the ends of the row only so as not to break the continuous lens.
  • For better occupancy coverage in longer rows, sensors may be placed mid-run, but keep in mind this will break the continuous lens into discrete sections. Alternatively, remote sensors may be used, note the same wiring rules will apply.

Occupancy Sensor Coverage:

Note:
The longer dimension of the detection area (Y1, Y2) is parallel to the longer dimension of the luminaire.

TruGroove-ID-49-Perimeter-Fixtures-Drywall-Ceiling-Trim-fig-
\(21\)

Daylight Sensor
The light sensor measures the total amount of light in a circular field of approximately 80% of the PIR detection area. The following aspects should be observed during installation:

  • Minimum distance from the window ≥ 2ft (0.6m).
  • Prevent light reflections from outside entering the sensor (for example sunlight reflection on a car hood) as this will lead to incorrect light regulation.

As a guideline, the formula 0.72 X H can be used to calculate the minimum distance between the window and the sensor whereby H is the height from the bottom of the window to the sensor.

TruGroove-ID-49-Perimeter-Fixtures-Drywall-Ceiling-Trim-fig-
\(22\)

The detection area for the movement sensor can be roughly divided into two parts;

  • Minor movements (a person moving ≤ 3ft/s or 0.9m/s).
  • Major movements (a person moving ≥ 3ft/s or 0.9m/s).

Photosensor spatial response

ATTENTION:
Install under national and local building and electrical codes.

© 2019 Signify Holding. All rights are reserved. Reproduction in whole or part is prohibited without the written consent of the copyright owner.

  • Phone: 604.888.6811
  • Web: ledalite.com/products

Revision C November 16, 2023

Signify North America Corporation. 400 Crossing Blvd, Suite 600 Bridgewater, NJ 08807.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>