CANADIAN SPA TP500 Montreal UV Spa Hot Tub User Guide
- May 15, 2024
- CANADIAN SPA
Table of Contents
- SAFETY INFORMATION – Europe (50Hz)
- Delivery Options
- Hot tub equipment side
- Pre-Delivery Information
- Filling up your Spa
- Plug and Play Installation
- How your spa functions
- Spa Functions
- TROUBLESHOOTING GUIDE
- Standard Settings 1 x Pump
- Troubleshooting
- Fill it up!
- Ready Mode and Rest Mode
- Restricting Operation
- Show and Set Time-of-Day
- General Messages
- Set ups
- Your Hot Tub Parts
- CN6013 Circuit Board
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Montreal UV Spa
Owners Manual TP500
213 x 153 x 79cm (84 x 61 x 32″)
KH-10033
For
Service Support please contact us anytime:
support.canadianspacompany.com
SAFETY INFORMATION – Europe (50Hz)
IMPORTANT SAFETY INSTRUCTIONS
When installing and using this electrical equipment be sure to follow these basic safety precautions:
-
WARNING: To reduce the risk of injury, do not permit children to use this productunless they are closely supervised at all times.
-
DANGER: Risk of accidental drowning. Extreme caution must be exercised to prevent unauthorised access by children. To avoid accidents, ensure that children cannot use this spa unless they are supervised at all times.
-
DANGER: Risk of injury. The suction fittings in this spa are sized to match specific water flow created by the pump. Should the need arise to replace the suction fitting or the pump, ensure that the flow rates are compatible. Never operate the spa if suction fittings are broken or missing. Never replace a suction fitting with one rated less than the flow rate marked onthe original suction fitting.
-
DANGER: Risk of Electrical Shock. Install at least 5 feet (1.5m) from all metal surfaces. As an alternative, spa may be installed within 5 feet (1.5m) of metal surfaces if each metal surface is permanently connected (bonded) by a
minimum ground wire. -
DANGER: Risk of Electrical Shock. Do not permit any electrical appliance such as a light, telephone, radio, television, etc. within 5 feet (1.5m) of a spa unless such appliances are installed and built-in by the manufacturer.
-
ELECTRICAL SUPPLY: The electrical supply for this product must include a suitably rated switch or circuit breaker to open all ungrounded supply conductors to comply with the national electrical standards. This disconnect must be readily accessible and visible to the spa occupant but installed at least 5 feet (1.5m), from the spa water.
-
WARNING: To reduce the risk of injury:
a) The water in the spa should never exceed 40°C (104°F). Water temperature between 38°C (100°F) and 40°C (104°) is considered safe for a healthy adult.
Lower water temperatures are recommended for young children and when the spa use exceeds 10 minutes.
b) Since excessive water temperatures have a high potential for causing foetal damage during early months of pregnancy, pregnant women should limit spa water temperatures to 38°C (100°F)
c) Before entering a spa, the user should measure the water temperature with an accurate thermometer since the tolerance of water temperature regulating devices varies.
d) The use of alcohol, drugs, or medication before or during spa use may lead to unconsciousness with the possibility of drowning.
e) Obese persons and persons with a history of heart disease, low or high blood pressure, circulatory system problems, or diabetes should consult a physician before using a spa.
f) Persons using medication should consult a physician before using a spa since some medication may induce drowsiness while other medication may affect heart rate, blood pressure, and circulation. -
AUDIO/VIDEO EQUIPMENT WARNINGS (Optional equipment based on model)
CAUTION: Risk of Electrical Shock. Do not leave compartment door open. -
CAUTION: Risk of Electrical Shock. Replace components only with identical components.
-
WARNING: Prevent Electrocution. Do not connect any auxiliary components (for example cable, additional speakers, headphones, additional audio/video components, etc.) to system.
-
CAUTION: Risk of Electrical Shock. Do not service this product yourself as opening or removing audio covers may expose you to dangerous voltage or other risk of injury. Refer all servicing to qualified service personnel.
-
CAUTION: Risk of Electrical Shock. When the power supply connections or power supply cord(s) are damaged; if water is entering the audio / video compartment or any electrical equipment compartment area; if the protective shields or barriers are showing signs of deterioration; or if there are signs of other potential damage to the unit, turn off the unit and refer the servicing to a qualified service personnel.
-
This unit should be subject to periodic routine maintenance (for example, once every 3 months) to make sure that the unit is operating properly.
-
CAUTION: Do not operate audio video controls while inside the spa
-
Installation of the spa for other than a residential dwelling will result in voiding the manufacturer’s warranty.
-
Do not bring any object into the spa that could damage the spa shell.
-
Never insert any object into any opening.
-
WARNING: Do not sit on the spa cover or place objects on it.
-
Remove any water or debris that may collect on the spa cover.
-
WARNING: Do not use the spa immediately after strenuous exercise.
-
If you feel pain or dizziness at any time while using the spa, discontinue use and contact a physician.
-
WARNING: To reduce risk of injury it is especially important that persons with pre-existing health conditions or problems such as obesity, heart disease, high or low blood pressure, circulatory problems, pregnancy or diabetes to consult their doctor before using the spa.
-
WARNING: Observe reasonable time limits when using the spa. Long exposures at high temperatures can cause high body temperatures. Symptoms may include dizziness, nausea, fainting, drowsiness, and reduced awareness. These effects could possibly result in drowning.
-
WARNING: The spa jets produce a stream of water with relatively high pressure.
Prolonged exposure of localized area of the body may cause bruises to the skin. -
IMPORTANT: The include warming sign must be posted where all users of the spa can see and read it.
-
WARNING: To avoid risk of drowning. The Spa cover should be in place and properly latched when spa is not in use.
-
IMPORTANT: Read and understand the warnings on the spa cover.
-
Proper water chemistry is necessary to maintain the water and prevent possible damage to spa components.
WARNING
REDUCE THE RISK OF ELECTROCUTION
- Never place an electric appliance within 5 feet (1.5m) of spa.
REDUCE THE RISK OF CHILDREN DROWNING
- Supervise children at all times.
- Attach and lock down spa cover after each use.
REDUCE THE RISK OF OVERHEATING
- Check with a doctor before use if pregnant, diabetic, in poor health, or under medical care.
- Exit immediately if uncomfortable, dizzy, or sleepy. Spa heat can cause hypothermia and unconsciousness.
- Spa heat in conjunction with alcohol, drugs, or medication can cause unconsciousness.
WHEN PREGNANT; soaking in hot water for long periods can harm your fetus. Measure water temperature before entering
- Do not enter spa if water is hotter than 100ºF (38oC).
- Do not stay in spa for longer than 10 minutes.
REGISTER YOUR WARRANTY ONLINE
Please be sure to register your spa so we can efficiently assist with any
questions you may have.
Until your spa has been registered, we will not have record of your ownership.
To register your spa, visit: canadianspacompany.com/pages/warranty-
registration
SERIAL NUMBER:____Purchase Date:
Delivery Video Guides on Canadian Spa Company channel
Delivery Options
Collection
Buyer collects hot tub using own transport from our warehouses.
Please arrange 96 hours prior to collection
Kerbside
Delivery to outside the kerbside of house, customer to be present to sign for
the delivery. Customer responsible to position the spa after it is removed
from truck.
Back Garden Placement
Delivery from our warehouse and delivered to customers hot tub location.
Customer to provide access for position.
Check measurements required for each spa.
Cancellation Policy
We require a 48-hour cancellation notice in writing or email prior to your
scheduled delivery. If we are notified later, then a reasonable cancellation
charge will be applied.
Back Garden Placement & Demonstration
Delivery from warehouse to customer, moved into hot tub location then fully
installed (including all accessories) and commissioned
(No Electrics). Followed by a maintenance tutorial.
Customer to provide access for position.
Check your measurement guidelines for each spa.
Optional crane service is available on request
BACK GARDEN DELIVERY FORM
Take your smart phone and tape measure outside with you and attach information directly from your phone! At your convenience upload your information to our site and our experienced delivery team will organise your delivery and installation.
Back Garden Placement :
Fill in our online Back Garden Form
Kerbside Drop Off:
Arrange a convenient time to deliver
- FILTER BASKET: Assembly that holds the filter cartridge (Note: configurations may differ from model to model).
- LED SPA PILLOW: To rest you head and neck (replaceable).
- AIR CONTROLLER: These are located around the top of your spa. Increase or decrease the force of your jets by opening or closing the air control valves.
- ILLUMINATED CUP HOLDER: Placeholder for drinking receptacle.
- WATERFALL ON/OFF VALVE: Located on top rail of spa used to adjust the waterfall flow.
- LED ILLUMINATED SPEAKER: Audio speaker system for playing music from an MP3 device
- AROMATHERAPY: A small canister that holds scented beads and works in conjunction with the air control system to create an aromatic experience.
- AUDIO VOLUME CONTROL: Allows control of functions from within the hot tub connected Bluetooth (6 button control).
- TOPSIDE CONSOLE: Button pad and temperature display panel located on the top of the spa into which various commands, control sequences and options for operating the spa can be input. User can set temperature, filtration cycle and heating mode through the console.
- SUCTION FITTING: Located at the bottom of the spa, used to return water back into the filter and pump system.
- JET (VARIOUS): Device that ejects air and water, creating water movement in the spa. Adjustable, directional, rotational and interchangeable.
- WATERFALL & PERIMETER LIGHTING: To create a relaxing spa mood.
- VACUUM BRAKE: Ensures the suction inside the spa is cut off immediately if blocked.
- LARGE DIVERTER: Diverts the flow of water from one jet zone to another
- MAIN SPA LIGHT
- DRAIN OUTLET
HOW JETS WORK
Air is mixed with the water by using the air controls to create massage(s) of
varying degrees. Water flow is adjusted by simply turning the outer face of
the full sized jets. Our hot tubs have a combination of pulsating, rotating,
and directional adjustable jets.
| 2.25” Directional jet Adjustable and interchangeable jet features
adirectional nozzle. The jet can be removed byturning it counter-clockwise. To
replace thejet push inward and clockwise until it clicksinto place.| | Air
Controller
These are located around the top of your spa. Increase or decrease the force
of your jets by opening or closing the air control valves.| | 2.25” Twin Roto
jet
Adjustable and interchangeable jet spins and pulsates. The jet can be removed
by turning it counter-clockwise. To replace the jet push inward and clockwise
until it clicks into place.
---|---|---|---|---|---
| 3” Directional jet Adjustable and interchangeable jet features a directional
nozzle. The jet can be removed by turning it counter-clockwise. To replace the
jet push inward and clockwise until it clicks into place.| | Waterfall control
Located on the topside of the spa, this valve adjusts water flow to the
waterfall.| | 5” (Jumbo) Directional jet Adjustable and interchangeable jet
features a directional nozzle. The jet can be removed by turning it counter-
clockwise. To replace the jet push inward and clockwise until it clicks into
place.
| 3” Massage jet
Rotational and interchangeable jet which spins to deliver a soothing massage.
The jet can be removed by turning it counterclockwise.
To replace the jet push inward and clockwise until it clicks into place.| |
Aroma basket cap
Open cap to place aromatherapy beads. Close after use.| | 5” Massage jet
Rotational and interchangeable jet features an internal spinner to deliver a
low pressure soothing massage. The jet can be removed by turning it counter-
clockwise. To replace the jet push inward and clockwise until it clicks into
place.
Hot tub equipment side
CONTROL PACK: Unit that controls spa operations, containing electronic
programming boards, heater and all connections for Pump(s), Light(s), Ozone
Generation Unit and Topside Console.
Also referred to as ‘Spa Pack’ or ‘Controller’.
HEATER : Electrical resistance device located in the Spa Controller
containing the heating element and 2 temperature sensors. The flow through
heater heats the spa’s water as it flows across the heating element. Heaters
are available in several wattages.
MASSAGE PUMP: Electro-mechanical device to move water, consisting of a wet end
and a motor.
OZONE /UV GENERATOR: Device that generates ozone to aid n maintaining
water quality. Generates Ozone and UV to help eliminate organic material such
as body oils, dead skin cells and hair.
DRAIN VALVE: Valve located on the outside of spa cabinet used to drain
water from the spa. A garden hose can be attached to the drain valve.
EQUIPMENT BAY: Located under the spa shell covered by access panels that
houses the spa controller and equipment.
SLICE VALVE: Two-position (open or closed) sliding valve, used to cut off
water flow which allows for service to be performed on the spa equipment
without the need to drain the spa. Slice valve operations: up for open, down
(toward the valve body) for closed.
UV Light Water Treatment System
- Input Voltage: AC 230V 50/60 HZ
- Operating Current: 100mA
- Power: 15W
- Purification of water: 15L / Minute
- UV Lamp Lifetime 6000-8000 Hr
- Replace UV Bulb Annually
How to change Canadian Spa Wave Zone Lamp
IMPORTANT:
- Turn off the power.
- Allow the UV Lamp to cool before replacing.
- Do not look at a lit UV Lamp to avoid eye damage.
Turn both red valves off horizontal position (see photos above) to SHUT OFF the water and isolate the UV chamber.
|
---|---
Step 1: Unscrew the 2 red-marked screws.| Step 2: Remove the red lid
|
Step 3: Unplug this white connector| Step 4: Take out this black protective
sleeve
|
Step 5: Pull out the bulb to change it| Step 6: Put the bulb inside the metal
tube and cover it with black protective sleeve
|
Step 7: Plug in the white connector| Step 8: Cover the red lid and install
these 2 screws
Wave Zone UV Lamp Kit KK-11202
The Advanced Oxidation Process is used in Canadian Spa Company’s Hot Tubs.
Combining our Ozone Generator with Ultra Violet Light creates a unique
bacteria fighting superhero: Super Hydroxyl Radicals. They easily overcome
even the most powerful of bacteria.
Canadian Spa Hot Tub Health Status
Our new Spa Status lets you know the health of your spa.Our LED’s changes
colour to alert you 24 x 7.
Now you can easily monitor your spa operations.
Pre-Delivery Information
Spa Delivery Access Guide
Before delivery check your spa height and width and add 5cm clearance on each side to ensure access.
Check that the hot tub can clear a 90° turn
Rotary Isolation Switch (pictured). Make sure you have a qualified electrician prepare the electrics. Allow 5 metre slack to connect to Spa.
Ensure you have prepared a level concrete base or a properly fitted existing
patio or decking with access to a drain.
NOTE : A 10-15 cm concrete base is ideal preparation for a hot tub.
Access: Canadian Spa hot tubs are usually delivered on a flat bed
trailer, up to 5 metres long, 2.4 metres wide and 3.5 metres high. Please
ensure that there is adequate access for such a vehicle to reach your
property. When off loading from our vehicle to the spa site, a minimum of
1100mm width is required, (some models vary) this also needs to be flat and a
minimum clear vertical height of 9ft should be considered also.
Electrical supply: If you are having your spa installed, it will be
necessary to have a dedicated electrical circuit supply fitted. You will
require up to 32 Amp (type C Breaker) supply, dependent on the length from the
service point. Your spa must be protected via a RCD and suitable over current
protection.
A minimum of 5 metres of cable is required for connection into your spa from
the Isolator.
Electrical installation: Arrange for a licensed electrician run the
required 230-volt power line to the spa installation site.
This power line must be permanently connected (hard-wired) to the mains
supply. Do not use extension cords or plug-in type connections. At the site
where the spa is to be located leave 5 metres of cable and the appropriate
cable gland. All electrical wiring to a spa must be installed by a qualified,
licensed electrician, and meet required electrical standards.
Water : The best means of filling your spa is with a garden hosepipe (use
cold water not hot water). Please ensure that you have one readily available.
If you are aware that your water pressure is poor, we should be advised prior
to delivery. The design of our spas allows for easy drainage, again, using the
hosepipe which conveniently fits onto the drain valve situated at the base of
your spa. Ideally, you should empty the water to a nearby drain. You may wish
to purchase a suitable submersible pump to speed up this process.
Decking around your spa: Ensure that you are aware of the above
measurements. Always consider during your planning that any decking boards and
supporting beams that you install allow access to the sides of your Spa. It is
the customers’ responsibility to ensure that any decking is clear of these
areas prior to any visit by our technicians (Allow 1 metre clearance around
your hot tub and if you have decking ensure part of your decking can be
removed in order to gain access for future repair or servicing). If you are
unsure then please ask before ground construction and the delivery of your
spa.
Your spa must be sited on a solid, flat, level base which is the same size or
larger than the spa. The base can be either a 10-15cm concrete slab or
suitably strengthened timber decking or existing patio area assuming it has
suitable foundations of hardcore. Whatever base area is chosen, it must be of
suitable load bearing capacity. Please ensure your base has suitable drainage.
Ensure part of your decking can be removed in order to gain access for future repair or servicing
Optional Crane Service is available
Filling up your Spa
IMPORTANT : Before filling the spa, it is important to read and
understand the water chemistry section of this manual. Do not proceed until
the water chemistry section is understood and the source water is tested.
Verify that the spa is in the desired final location. Refer to the ‘Choose
your location’ section – once filled, the spa cannot be moved without
draining.
Follow these filling instructions to avoid damage to the spa pumps:
-
Leave power to the spa off until spa is completely filled.
-
Never leave an unfilled spa exposed to direct sunlight with out the Spa Cover installed. Resulting damage such as bubbles and wrinkles in the spa shell and fading of the jet faces is not covered by the manufacturer’s warranty.
-
Never operate spa pump without water because this could result in permanent pump and/or heater damage which is not covered by the manufacturer’s warranty.
-
Remove all warning labels from spa shell.
-
Remove the filter lid, basket and filter cartridge.
-
Inspect all Jets (shipping may cause jets to become loose or detached). Check to see that the black Drain Valve (located to the left or right of the front access panel) is closed.
IMPORTANT : Follow the next steps closely to prevent damage to the Spa Pump.
Filter Type: Glacier Microban Filter Set SKU: KA-10082 -
Insert garden hose or other clean water source directly into filter housing. Push hose pipe into filter housing until it stops. Fill up to top of the honeycomb grill of the skimmer (see photo above). Secure hose placement and turn on water.
Filling the spa through the filter housing prevents an air lock from occurring in the spa pump, which is an air pocket preventing the flow of water through the pump. Permanent damage caused by running the pump with an air lock (or without water) is not covered by the manufacturer’s warranty. -
Check for leaks! Although spas are fully checked at the factory, shipping and delivery might cause a leak.
-
Before power is applied familiarise yourself with the spa control operations.
-
Turn water off and remove hose.
-
Reinstall filter cartridge, basket and filter lid.
-
Add start-up Chemicals after power is turned on.
Draining your Spa/Using drain valve
IMPORTANT : Before draining your spa shut off the electrical breaker connected to the spa.
- Inset closed position. (Push in to release internal O-Ring seal prior to Step #2)
- Extended closed position )pull out to fully extended position and remove cap); place cap in safe place.
- Full extended closed position (attach garden hose in the full extended closed position).
- Open position for draining (turn hose and fitting ¼ turn clockwise and insert ½ way to open position for draining).
- Open position for draining (turn hose and fitting ¼ turn counter clockwise and pull out to full extended closed position).
- Full closed extended position (remove hose and replace cap).
- With replaced cap screwed on, turn ¼ turn clockwise and push in all the way to inserted closed position.
- Closed inserted position.
Accessing your spa controls
Plug and Play Installation
|
---|---
CONNECTING HOT TUB TO SOCKET
Our spa comes with an 13 amp RCD already connect to your spa
This can be easily plugged into a waterproof socket.
The cable can be disconnected and moved to the other side of the spa if
needed.
Installation : Direct wire electrical power requirements
Power connections
Single Phase (A) is the normal wiring configuration for most household
electrical installations (3 wires: live, neutral and earth). If however you
have insufficient Amps you will need to use other connection (see below).
Single Phase connection (B) is used in circumstances where the power supply is
limited and where you need more Amps.
Phase (C) is used in certain areas of Europe where 3 Phase power is available
and the installation warrants it.
NOTE : Canadian Spa Company requires that the electrical installation of
your hot tub is carried out by a professionally licensed electrician and that
all local electrical and building codes are adhered to, unless Plug & Play
models.
CONNECTING HOT TUB TO RCD AND CONSUMER PANEL:
- All hot tubs must be wired with the appropriate sized wiring. Failure to do so will cause equipment damage and will not be covered by your warranty
- All hot tubs must be protected with a appropriately sized RCD (Residual Current Device) in the consumer panel. Have your electrician verify using the diagram opposite.
ADDITIONAL ITEMS NEEDED TO HELP COMPLETE ELECTRICAL CONNECTION:
- RCD Breaker,
- Electrical cable (check length and width for amperage and distance),
- Cable gland.
- Tidy clips
A.) Single Phase connection (most common):
Single Phase (live 1, neutral 1, live 2, neutral 2, ground)] 230VAC, 50/60Hz,
2þ, 16A, (Circuit Breaker rating = 20A max each phase line.).
Installation: Electrical power requirements
B.) 2 x Single Phase
(live 1, neutral 1, live 2, neutral 2, ground)] 230VAC, 50/60Hz, 2þ, 16A,
(Circuit Breaker rating = 20A max each phase line.)
In 2x16A Service: Pump 2 (if any) and the Heater are on one service.
Everything else is on the other service.
For 2-Wire connection:
- Completely remove jumper on J51 and J88.
- Completely remove jumper on J52 and J62.
- Make a connection between jumper J60 andJ36
- Make a connection between jumper J41 and J12
- Make a connection between jumper J46 and J75
- Make a connection between jumper J20 and J77
- Make a connection between jumper J38 and J54
- Put DIP switches A2, A3 and A5 on ON
C.) 3-Phase 5 wires (live 1, live 2, live 3, neutral, ground)]
400VAC, 50/60Hz*, 3þ, 16A, ( Circuit Breaker rating = 20A max each phase
line.)
In 3x16A Service:
Pump 2 is on one service.
The Heater is on another service.
Everything else is on the remaining service.
For 3-phase connection:
- Completely remove jumper on J51 and J88.
- Completely remove jumper on J52 and J62.
- Make a connection between jumper J60 andJ45
- Make a connection between jumper J41 and J79
- Put DIP switches A2 and A3 on ON and DIP switch A5 on OFF.
POWERING UP YOUR SPA
Once the spa is properly wired and filled with water, the spa power can be turned on and Start-up chemicals added.
-
Turn on RCD breaker. If breaker trips immediately check Neutral and Ground Wire connections. Upon initial power up, 4 sets of numbers flash on the LED display of the topside Console. The last number in the sequence is the incoming power meter which can be used to verify that the spa is wired correctly.
-
The spa begins an automatic priming routine which will last 6 minutes (“Pr” is on the LED display).
-
The priming routine will automatically run each spa pump to prime. When the “Pr” is displayed, press any PUMP button to prime that pump or wait for the priming routine to turn on the Pump. IMPORTANT: To avoid pump damage, do not run pumps for more than 1 minute without moving water. If no water is moving, turn the power off and perform air lock procedure.
-
The Topside Console display flashes “38C/100F” then press “–C/F” for approximately 2 minutes to determine water temperature as it flows through the heater.
-
The default pre-set temperature is 36.5°C. The last measured temperature is constantly displayed on the LCD readout. This temperature will be current only when the pump has been running for at least 2 minutes. Set the desired temperature between 26- 40°C (80-104°F) by pressing the temp button(s).
If the water temperature is below the set temperature, the spa’sheater and heat indicator light will turn on. All features of the Topside Console will be available. The spa will heat approximately 1° every 30 minutes per 1,000 litres. -
Check for leaks! Although spas are fully checked at the factory, shipping & delivery might cause a leak. Remember to pay
particular attention to barrel unions adjoining the heater.
Contact your Canadian Spa dealer directly if there is a problem.
If your new spa pump does not prime (flow) on the initial start-up you may be experiencing an “air lock”.
This normal occurrence can be easily corrected by loosening the plumbing union on the suction side of the Jet or Pump until water flows into the pump and all air is expelled.
PRESS BUTTONS SLOWLY FOR FIRST RUN WHEN STARTING UP ONCE PR EXITS, SET TEMPERATURE ON SPA (SEE SPA OPERATION SECTION FOR DIFFERENT SPA TOPSIDES)
How your spa functions
ATTACHING YOUR SPA COVER
The Spa Cover is an important accessory to help preserve the spa’s
temperature. The Spa Cover also serves as a safety device, preventing
unauthorised users from entering the spa. Proper installation of the Spa Cover
is an important addition in the spa installation.
- Remove Spa Cover from packaging.
- Place Spa Cover on spa in order to allow easy access to the topside console when opening the cover.
- Line up attaching straps and secure with mounting hardware and use locking mechanism to lock Spa Cover in place.
IMPORTANT:
Always lock Spa Cover in place when not using the spa. Do not walk or sit on
Spa Cover.
Remove snow build-up to avoid breaking the foam inner core. Do not drag Spa
Cover on rough surfaces.
TOP MOUNT”HOT TUB COVER LIFTER
Fully compatible with ALL our Canadian Spa hot tubs and spas and most other
brands; this Cover Lifter is the ideal choice to complement your Hot Tub,
making cover removal and replacement a quick, one-handed operation and
reducing wear and tear.
- Low-profile design
- Virtually zero clearance required behind spa – great for tight spaces (particularly if your spa is located in a gazebo)
- Mounts directly to the spa
- Fits up to 2.4m Spas
- Made of Aluminium
BOTTOM MOUNT” HOT TUB COVER LIFTER.
Fully compatible with Canadian Spas; this Cover Lifter is the ideal choice to
complement your hot tub or spa, making cover removal and replacement a quick,
one-handed operation while reducing wear and tear on your hot tub cover.
- Mounts directly to the spa
- Made of black powder-coated Aluminum
- Requires 31 cm – 46 cm rear clearance
LED LIGHTING
Change the colour of your spa with a press of a button, 13 colour options to choose from. Chromatherapy is a great way to relax in your spa using colours to change your mood.
Spa Functions
Pumps
Press the “Jets 1” button once to turn pump 1 on or off, and to shift between
low- and high-speeds if equipped. If left running, the pump will turn off
after a time-out period. The pump 1 low-speed will time out after 30 minutes.
The high-speed will time out after 15 minutes.
The low-speed of pump 1 runs when the other pump is on. If the spa is in Ready
Mode, Pump 1 low may also activate for at least 1 minute every 30 minutes to
detect the spa temperature (polling) and then to heat to the set temperature
if
needed.
When the low-speed turns on automatically, it cannot be deactivated from the
panel, however the high speed may be started.
Filtration and Ozone
Pump 1 low and the ozone generator will run during filtration.
The system is factory-programmed with two filter cycles that will run 10
minutes after power-up. The filter duration is programmable.
Freeze Protection
If the temperature sensors within the heater detect a low enough temperature,
then the pump automatically activate to provide freeze protection. The pump
will run either continuously or periodically depending on conditions.
In colder climates, an optional additional freeze sensor may be added to
protect against freeze conditions that may not be sensed by the standard
sensors. Auxiliary freeze sensor protection acts similarly except with the
temperature thresholds determined by the switch. See your dealer for details.
Clean-up Cycle
When a pump is turned on by a button press, a clean-up cycle begins 30 minutes
after the pump is turned off or times out.
The pump and the ozone generator will run for 30 minutes or more, depending on
the system.
Temperature and Temp Range
Adjusting the Set Temperature
When using a panel with Up and Down buttons (Temperature buttons), pressing Up
or Down will cause the temperature to flash. Pressing a temperature button
again will adjust the set temperature in the direction indicated on the
button. When the LCD stops flashing, the spa will heat to the new set
temperature when required.
TEMPERATURE UP
TEMPERATURE DOWN
Pressing the button again will cause the temperature to change in one
direction (e.g. UP). After allowing the display to stop fl ashing, pressing
the Temperature Button will cause the temperature to flash and the next press
will change the temperature in the opposite direction (e.g. DOWN).
The temperature can be set between 16°C and 40°C (60°F and 104°F).
Press-and-Hold
If a Temperature button is pressed and held when the temperature is flashing,
the temperature will continue to change until the button is released. If only
one temperature button is available and the limit of the Temperature Range is
reached when the button is being held, the progression will reverse direction.
LIGHTS
Press light button to turn on and off the lights.
Each consecutive press will alternate through different lighting modes and
colours.
Airlock warning messages
If you receive any of these error messages on your spa you could have an
airlock: FLO
How to release an airlock
Air Lock Release Valves
To bleed air from the pump valves (see photo opposite):
- Turn one of these valves slightly until you can here a hissing noise
- Once water comes out tighten the valve back up, pump has been bled of the trapped air
If your new spa pump does not prime (flow) on the initial start-up you may be
experiencing an “air lock”.
This normal occurrence can be easily corrected by loosening the plumbing union
on the suction side of the Jet or Pump until water flows into the pump and all
air is expelled.
PRESS BUTTONS SLOWLY FOR FIRST RUN WHEN STARTING UP ONCE PR EXITS, SET
TEMPERATURE ON SPA
Chlorine Granules – Disinfection
To protect your health, ensure that your spa water is disinfected thoroughly
on a regular basis. This is particularly important in spas, as the high water
temperatures provide an ideal breeding ground for bacteria. To prevent water
care problems, there must always be sufficient levels of disinfectant in the
water.
The use of Chlorine granules is the traditional method of disinfecting spas.
Chlorine granules dissolve quickly, without residues, and do not bleach the
surfaces. The granules are pH-neutral, i.e. the pH value of the water does not
change with the dosing of the granules.
Check the pH value using the 3 function test strips at least once a week, and,
if necessary, adjust it to 7.2 – 7.6. Add 10 g/m³ of Chlorine granules after
each bathing session. Let the circulation pump run for 10 minutes, and then
check afterwards using 3 function test strips that the ideal value of 1.0 –
1.5 ppm (mg/L). is reached. If necessary, continue to dose. The granules are
dosed directly into hot tub water. K A-10123
pH Up and pH Down
The pH value is the basis for reliable disinfection. The care products only
work perfectly when the levels are correct, meaning the water is not harmful
to skin, hair or eyes. The ideal pH value is between 7.2 and 7.6. The pH value
is influenced by various factors. For example it increases when fresh water is
added. Increasing the water temperature or using the jets changes the pH
value. Therefore, check the value at least once a week and, if necessary,
increase the levels using pH Up or decrease with pH Down. The granules are
dosed directly into
the spa water.
pH Up: KA-10051 / pH Down: KA-10050 Foam Free
If your spa water has a tendency to foam, then we recommend you add Foam Free.
The product is added directly to the spa water. If the water continues to
foam, even after the product has been added, replace the water.
K A-10054
Scale Control
The overall hardness is a measure of the amount of calcium and magnesium in
the water. Scale Control prevents calcium precipitations forming on the walls
and in the pipes of your spa. Youcan find out the overall hardness level of
your water by contacting your local water supplier. With a level over 200 ppm
(mg/L)., heating the water can cause lime-scale deposits on the walls,
creating rough surfaces. To prevent lime-scale deposits, always use Scale
Control after refilling.
K A-10055 Alkalinity Booster
Alkalinity booster will prevent erratic changes in the pH level of the spa/hot
tub water. Alkalinity Booster will help the bromine or chlorine in the spa/hot
tub work more efficiently. Alkalinity Booster raises the total alkalinity of
the spa/ hot tub water preventing any corrosion that could be cause by low
alkalinity.
K A-10146
Test strips
Canadian Spa 3 Way Test strips to check the levels of Chlorine, PH and Total
Alkalinity. Simple and easy to use. Ensure your spa is always safe to use.
Pack of 50 strips. Dip a test strip into the water and compare to the colour
chart to take readings for: – Chlorine, pH, Total Alkalinity.
TIP : Chlorine and pH should be checked EVERY TIME the spa is used to
ensure that the water is safe to use! Go to App, put in your test results and
it will tell you what to add and how much.
K A-10052
Spa Clear
Super highly Concentrated Clarifier
- Adds brilliance back to spa water
- Aids filter in removing suspended particles
- Non-toxic. Will not affect pH level.
- Reduces chlorine demand when used regularly
- Restores water clarity
K A-10053
TROUBLESHOOTING GUIDE
PROBLEM | POSSIBLE CAUSE | SOLUTION |
---|---|---|
CLOUDY WATER | A) organic contaminants build-up |
B) suspended particles
C) pH high
D) total alkalinity too high
E) poor filtration
F) high dissolved solids| A) shock treatment with Granular Chlorine
B) add Granular Chlorine, use SPA-BALL
C) add pH DOWN until pH level reads 7.2–7.6
D) add pH DOWN, adjust total alkalinity to 80–150 p.p.m.
E) dirty filter, replace filter
F) empty spa and refill
COLOURED WATER| Debris in water| Use Chlorine Granules.
FOAMING| High concentration of oils and organic contaminants being agitated by
jet| Squirt FOAM-FREE on foam. Use the SPA-BALL
SCALE DEPOSITS| High calcium level, high pH, high alkalinity| Drain partially,
add Granular Chlorine, correct pH level to 7.2–7.6 and alkalinity to 80–150
p.p.m.
ODOUR| High level of organic contaminants combined chlorine.Chlorine level too
high| Shock with Granular Chlorine
EYE/SKIN IRRITATION| A) pH too low
B) combined chlorine due to high concentration of organic contaminants| A) add
pH up until level is 7.2–7.6
B) shock with Granular Chlorine, add disinfectant
NO CHLORINE/ BROMINE READING| A) high concentration of organic contaminants
using up sanitizers
B) test trips may be ineffective| A) add Granular Chlorine
B) replace at least once a year, keep cool and out of sunlight
Low PH and low-quality chlorine causes the heater element to calcify
pH SCALE
• Reduced efficacy of disinfection
• Corrosion of metals
• Skin & eye irritation
• Unpleasant odour| • Reduced efficacy of disinfection
• Skin & eye irritation
• Forms limescale deposits
• Staining of the filter
---|---
|
---|---
Helps to keep your spa clean and achieve crystal clear water!
Canadian Spa Company Spa Ball KA-10003
Chemical Video Guides on Canadian Spa Company channel
1 Pump Control System (TP500)
Initial Start-up
When your spa is first activated the display will do a count sequence of M100,
L232, V52, 1-3 afterwards a message will display ‘RUN PUMPS PURGE AIR’ on
Priming Mode – now press the JET Button to make sure the pump is running and
water flowing from the jets. If there is no movement of water please visit our
Service Portal:
support.canadianspacompany.com submit
a ticket in our system and our global team will effectively solve your issue
quickly and efficiently 24/7.
Priming Mode will run for approximately 5 minutes (Press TEMP-UP to skip
Priming Mode) then the spa will begin to run Jets on low speed and after a few
minutes the heater will start when in ‘R’ (Ready Mode).
Display Symbols
A – Heat | F – Light | K – Auxiliary (Jets 3 or Microsilk) |
---|---|---|
B – Ready Mode | G – Cleanup Cycle | L – Temperature Range (High/Low) |
C – Rest Mode | H – Jets 1 | M – Set (Programming) |
D – bbaTM 2 On | I – Jets 2 | N – Filter Cycle (1 or 2 or Both) |
E – WiFi (Cloud Connection) | J – Blower | O – AM or PM (Time) |
Standard Settings 1 x Pump
Press Menu button until you reach the mode you require.
TEMP
– Temp Up button – until arrow is either pointing up or down. (Arrow up will
maintain heat / Arrow down will drop the temp by 10 degrees.)
– Menu button to select.
MODE
– Temp Up button – press until either Ready or Rest is displayed (Ready
maintains its set temperature / Restwill only heat within the filtration
cycles)
– Menu button to select.
SET TIME
– Temp Up button – hour will flash on display.
-
press Temp up button until desired hour.
– Menu button to select – minutes will flash. -
press Temp Up button until desired minute.
– Menu button to select.
FLIP
– Temp Up button – will invert the display so it can be seen in spa.
– Menu button to select.
LOCK
Panel Lock
– Temp Up button – PANEL will be displayed.
- Temp Up button – cycle between On and Off.
- Once ON is displayed press MENU button to select.
(The buttons on topside panel will now be unresponsive)
Temp Lock
– Temp DOWN button – TEMP will be displayed.
- Temp up button – cycle between On and Off.
- Once ON is displayed press MENU button to select.
(The Temperature buttons will now be unresponsive – jet buttons will work)
UNLOCK
– Press and hold down TEMP UP while you press the MODE Button 2x Slowly.
(Topside panel is now unlocked and normal operations enabled)
HOLD
- Temp Up button – ‘HOLDING FOR 1:00’ will be displayed. (Pump/s will shut down for 1 minute to allow time to replace filters)
- Press Temp Up-to restart or wait for the minute HOLD to end.
FLTR 1
– Temp Up button – BEGN will be displayed.
– Temp Up button – Hour will be flashing.
-
Press Temp Up button to cycle to the hour preferred to start.
– Menu button to select – minutes now flash. -
Temp Up to adjust the minutes – goes up 15 minutes with every press.
– Menu button to select.
RUN HRS is then displayed.
– Temp Up button – press to how many hours you would like the filtration cycle to run. (recommended filtering cycle – 4 hours twice a day)
– Menu button to select. -
Minutes – press TEMP Up button – goes up in 15 minutes every press.
– F1 ENDS – Menu button to select.
FLTR 2
-
Temp Up button – OFF will be displayed press Temp Up for it to be ON
– Menu button to select.
– Temp Up button – BEGN will be displayed.
– Temp Up button – Hour will be flashing. -
Press Temp Up button to cycle to the hour preferred to start.
– Menu button to select – minutes now flash. -
Temp Up to adjust the minutes – goes up 15 minutes with every press.
– Menu button to select.
– RUN HRS is then displayed.
– Temp Up button – press to how many hours you would like the filtration cycle to run.
– Menu button to select. -
Minutes – press TEMP Up button – goes up in 15 minutes every press.
– Menu button to select.
F2 ENDS – press MENU button to select.
PREF
Service tech
UTIL
Service tech
Troubleshooting
USE | POSSIBLE CAUSE | SOLUTION |
---|
•No power
•RCD trips| Breaker or RCD off
Loose wire connection
Mis-wired
Component failure| Check that RCD breaker is turned ON
Check wire connections
Check wiring per diagram, especially neutral wire Perform elimination test to
determine failed component. See elimination test section
•Heater not operating or spa not heating| Temperature set to low Water level
too low
Blown fuse
Component failure| Set temperature above current water temperature Add water
until water level is 1 inch (25mm) above Water Line Check 30amp bus fuse on
control board Contact dealer
•Pump not operating or turns off after a short time| Air lock
Improper voltage to pump
Time out
Component failure
Thermal overload| See Air lock procedure Page 12
Contact dealer or qualified electrician
As a safety precaution, the Spa Controller only allows Pump operation for 15
minutes continuously
Contact dealer or qualified electrician
During extreme high ambient temperatures the pump motor may reach the motor
thermal overload limit. Wait until motor cools and retry. if problem persists
contact dealer
•Pump surging
•Light will not turn on| Low water level
Burned out bulb
Light bulb may have fallen out| Add water until water level is 1 inch (25mm)
above water line
Change bulb
Unscrew back housing and reinsert bulb
•Ozone Generation Unit will not operate| Blown fuse
Burned out UV bulb
Component failure| Check Ozone fuse Replace unit Contact dealer
•No water Flow from Jets| Air lock
Adjustable jets turned off
Faulty pump or motor
Slice valve closed
Clogged filter| See air lock procedure Turn jets on
Contact dealer
Open slice valve
Clean or change filter
•Jet popped Out| Jet face not seated
Broken jet| Insert jet and turn clockwise until jet snaps into place you will
feel the jet seat
Contact dealer
•No air flow from jet| Adjustable jets turned off Air control valve not open
Broken jet
Jet not seated properly| Turn jets on
Open air control valve
Contact dealer
Insert jet and turn clockwise until jet snaps into place as it seats
•Noisy Pump or Motor| Air lock
Low water level
Clogged filter
Damaged or warn motor bearings| See air lock procedure
Add water until water level is 1 inch (25mm) above water line
Clean or replace filter
Contact dealer
•Spa Overheating| High ambient temperature Filtration duration| During extreme
high ambient temperatures the spa may overheat due to internal friction with
in the plumbing.
Reduce set temperature or remove spa cover to cool.
Reduce filtration cycle duration to minimum setting
•Spa will not turn off| Spa is trying to heat
Spa is on high filter cycle| Check set temperature or heat indicator light on
topside console is ON
Check filter cycle and reduce to 2 or 4
•Abnormal water| Excessive evaporation
Excessive splashing| Check and adjust spa cover if needed
Monitor water level after each use
•Water not clean| Dirty or clogged filter
Pore water chemistry
Insufficient filtration
Cycle duration High solids content| Clean or replace filter
See common water problems section
Based on usage Adjust filtration cycle duration
See common water problem section
SERVICE PORTAL
The FAQ section provides answers to your hot tub questions.
Submit a ticket in our system and our global team will effectively solve your
issue quickly and efficiently 24/7.
Fill it up!
Preparation and Filling
Fill the spa to its correct operating level. Be sure to open all valves and
jets in the plumbing system before filling to allow as much air as possible to
escape from the plumbing and the control system during the filling process.
After turning the power on at the main power panel, the top-side panel display
will go through specific sequences. These sequences are normal and display a
variety of information regarding the configuration of the hot tub control.
**Priming Mode – MO19***
This mode will last for 4-5 minutes or you can manually exit the priming mode
after the pump(s) have primed.
Regardless of whether the priming mode ends automatically or you manually exit
the priming mode, the system will automatically starts normal heating and
filtering at the end of the priming mode. During the priming mode, the heater
is
disabled to allow the priming process to be completed without the possibility
of energizing the heater under low-flow or no-flow conditions. Nothing comes
on automatically, but the pump can be energized by pushing the “Jets” or “Aux”
buttons.
Priming the Pump
As soon as the above display appears on the panel, push the “Jets” button once
to start the Pump in low-speed and then again to switch to high-speed. will
now be running in high-speed to facilitate priming. If the pump has not primed
after 2 minutes, and water is not flowing from the jets in the spa, do not
allow the pump to continue to run. Turn off the pump and repeat the process.
Note : Turning the power off and back on again will initiate a new pump
priming session. Sometimes momentarily turning the pump off and on will help
it to prime. Do not do this more than 5 times. If the pump will not prime,
shut off the power to the spa and call for service.
Important: A pump should not be allowed to run without priming for more than 2
minutes. Under NO circumstances should a pump be allowed to run without
priming beyond the end of the 4-5 minute priming mode. Doing so may cause
damage to the pump and cause the system to energize the heater and go into an
overheat condition.
Exiting Priming Mode
You can manually exit Priming Mode by pressing the “Warm” or “Cool” button.
Note that if you do not manually exit the priming mode as described above, the
priming mode will be automatically terminated after 4-5 minutes. Be sure that
the pump have been primed by this time. Once the system has exited Priming
Mode, the top-side panel will momentarily display the set temperature but the
display will not show the water temperature yet, as shown below.
This is because the system requires approximately 1 minute of water flowing through the heater to determine the water temperature and display it.
Power-up Screens
Each time the System powers up, a series of numbers is displayed.
After the startup sequence of numbers, the system will enter Priming Mode (See
Page 3).
Ready Mode and Rest Mode
In order for the spa to heat, a pump needs to circulate water through the
heater. The pump that performs this function is known as the “primary pump.”
Primary pump is a 2-Speed Pump 1, Ready Mode (indicated by R ) will
circulate water periodically, using Pump 1 Low, in order to maintain a
constant water temperature, heat as needed, and refresh the temperature
display.
This is known as “polling.”
Rest Mode (indicated by R ) will only allow heating during programmed
filter cycles. Since polling does not occur, the temperature display may not
show a current temperature until the primary pump has been running for a
minute or two.
In Rest Mode, the spa will only heat to set temperature during programmed
filter times.
Water Temperature Setting
Show and Set Time-of-Day
Be sure to set the Time-of-Day
Setting the time-of-day can be important for determining filtration times and
other background features.
When in the TIME menu, SET TIME will flash on the display if no time-of-day is
set in the memory.
24-hour time display can be set under the PREF menu.
Note:
This note refers to systems that do not keep track of Time-of-Day when powered
down.
If power is interrupted to such a system, Time-of-Day is not stored. The
system will still operate and all other user settings will be stored. If
filter cycles are required to run at a particular time of day, resetting the
clock will return the filter times to the actual programmed periods.
When such a system starts up, it defaults to 12:00 Noon, so another way to get
filter times back to normal is to start up the spa at noon on any given day.
SET TIME will still flash in the TIME Menu until the time is actually set, but
since the spa started at noon, the filter cycles will run as programmed.
Flip (Invert Display)
Restricting Operation
The control can be restricted to prevent unwanted use or temperature
adjustments. Locking the panel prevents the controller from being used, but
all automatic functions are still active.
Locking the Temperature allows Jets and other features to be used, but the Set
Temperature and other programmed settings cannot be adjusted.
Temperature Lock allows access to a reduced selection of menu items. These
include Set Temperature, FLIP, LOCK, UTIL, INFO and FALT LOG
Unlocking
This Unlock sequence may be used from any screen that may be displayed on a
restricted panel. If the panel has both an UP and a Down button, the ONLY
button that will work in the Unlock Sequence is the UP button. The temperature
will not Unlock if the Unlock sequence is done while the panel is displaying
“LOCK”.
Show and Set Time-of-Day
Be sure to set the Time-of-Day
Setting the time-of-day can be important for determining filtration times and
other background features.
When in the TIME menu, SET TIME will flash on the display if no time-of-day is
set in the memory.
24-hour time display can be set under the PREF menu.
Note:
This note refers to systems that do not keep track of Time-of-Day when powered
down.
If power is interrupted to such a system, Time-of-Day is not stored. The
system will still operate and all other user settings will be stored. If
filter cycles are required to run at a particular time of day, resetting the
clock will return the filter times to the actual programmed periods.
When such a system starts up, it defaults to 12:00 Noon, so another way to get
filter times back to normal is to start up the spa at noon on any given day.
SET TIME will still flash in the TIME Menu until the time is actually set, but
since the spa started at noon, the filter cycles will run as programmed.
Flip (Invert Display)
The control can be restricted to prevent unwanted use or temperature
adjustments. Locking the panel prevents the controller from being used, but
all automatic functions are still active.
Locking the Temperature allows Jets and other features to be used, but the Set
Temperature and other programmed settings cannot be adjusted.
Temperature Lock allows access to a reduced selection of menu items. These
include Set Temperature, FLIP, LOCK, UTIL, INFO and FALT LOG
Unlocking
This Unlock sequence may be used from any screen that may be displayed on a
restricted panel. If the panel has both an UP and a Down button, the ONLY
button that will work in the Unlock Sequence is the UP button. The temperature
will not Unlock if the Unlock sequence is done while the panel is displaying
“LOCK”.
General Messages
Priming Mode – MO19
Each time the spa is powered up, it will enter Priming Mode.
The purpose of Priming Mode is to allow the user to run each pump and manually
verify that the pump is primed (air is purged) and water is flowing. This
typically requires observing the output of each pump separately, and is
generally not possible in normal operation. Priming Mode lasts 4 minutes, but
you can exit it earlier by pressing any Temp button. The heater is not allowed
to run during Priming Mode.
Water Temperature is Unknown
After the pump has been running for 1 minute, the temperature will be
displayed.
Too Cold – Freeze Protection
A potential freeze condition has been detected, or the Aux Freeze Switch has
closed, and the pump is activated, depending on how your system was built. The
pump is ON for at least 4 minutes after the potential freeze condition has
ended, or when the aux freeze switch opens. In some cases, the pump may turn
on and off and the heater may operate during Freeze Protection. This is an
operational message, not an error indication.
Water is too Hot (OHS) – MO29
One of the water temp sensors has detected spa water temp 110°F (43.3°C) and
spa functions are disabled. System will auto reset when the spa water temp is
below 108°F (42.2°C).Check for extended pump operation or high ambient temp.
J29 Warning – MO44
J29 is typically used as a Heater Disable input. As such, it should not
typically be shorted at power-up. This message appears if J29 is shorted at
power-up.
Reminder Messages
Alternates with temperature or normal display.
Appears on a regular schedule, e.g. every 90 days.
Change the water in the spa on regular basis to maintain prop er chemical
balance and sanitary conditions.
Alternates with temperature or normal display.
Appears on a regular schedule, e.g. every 180 days.
Vinyl covers should be cleaned and conditioned for maximum life.
Alternates with temperature or normal display.
Appears on a regular schedule, e.g. every 365 days.
Filters should be replaced occasionally to maintain proper spa function and
sanitary conditions.
Appears on a regular schedule, e.g. every 365 days.
Check your ozone and/or UV generator per your spa manufactures’ instructions.
Alternates with temperature or normal display.
Appears on a regular schedule, e.g. every 365 days. Have a service technician
do a check-up on your spa per your spa manufacturer’s instructions.
Heater-Related Messages
Heater Flow is Reduced (HFL) – MO16
There may not be enough water flow through the heater to carry the heat away
from the heating element. Heater start up will begin again after about 1 min.
See “Flow Related Checks” below.
*Heater Flow is Reduced (LF) – MO17**
There is not enough water flow through the heater to carry the heat away from
the heating element and the heater has been disabled. See “Flow Related
Checks” below. After the problem has been resolved, you must press any button
to reset and begin heater start up.
*Heater may be Dry (dr) – MO28**
Possible dry heater, or not enough water in the heater to start it. The spa is
shut down for 15 min. Press any button to reset the heater start-up. See “Flow
Related Checks” below.
Heater is Dry – MO27
There is not enough water in the heater to start it. The spa is shut down.
After the problem has been resolved, you must press any button to reset and
restart heater start up. See “Flow Related Checks”. Heater is too Hot (OHH)
– MO30
One of the water temp sensors has detected 118°f (47.8°C) in the heater and
the spa is shut down. You must press any button to reset when water is below
108°f (42.2°C). See “Flow Related Checks” below.
A Reset Message may Appear with other Messages.
Some errors may require power to be removed and restored.
Flow-Related Checks
Check for low water level, suction flow restrictions, closed valves, trapped
air, too many closed jets and pump prime.
On some systems even when spa is shut down, some equipment may occasionally
turn on to continue monitoring temperature or if freeze protection is needed.
Sensor-Related Messages
Sensor Balance is Poor – MO15
The temperature sensors MAY be out of sync by or 3°F. Call for Service.
*Sensor Balance is Poor – MO26**
The temperature sensors ARE out of sync. The Sensor Balance is Poor fault has
been established for at least 1 hour.
Call for Service.
Sensor Failure – Sensor A: MO31, Sensor B: MO32 A temperature sensor or sensor circuit has failed. Call for Service.
Miscellaneous Messages
No Communications
The control panel is not receiving communication from the System. Call for
Service.
Pre-Production Software
The Control System is operating with test software. Call for Service.
°F or °C is replaced by °T
The Control System is in Test Mode. Call for Service.
- This message can be reset from the topside panel with any button press.
*Memory Failure – Checksum Error – MO22**
At Power-Up, the system has failed the Program Checksum Test. This indicates a
problem with the firmware (operation program) and requires a service call.
*Memory Warning – Persistent Memory Reset – MO21**
Appears after any system setup change. Contact your dealer or service
organization if this message appears on more than one power-up, or if it
appears after the system has been running normally for a period of time.
- This message can be reset from the topside panel with any button press.
Memory Failure – Clock Error* – MO20 – Not Applicable on the BP1500
Contact your dealer or service organization.
Configuration Error – Spa will not Start Up Contact your dealer or service organization.
A Pump Appears to be Stuck ON – MO34
Water may be overheated. POWER DOWN THE SPA. DO NOT ENTER THE WATER. Contact
your dealer or service organization. A Pump Appears to have been Stuck ON when
spa was last powered – MO35
POWER DOWN THE SPA. DO NOT ENTER THE WATER.
Contact your dealer or service organization.
The water level is too low
Some systems have a water level detect, and this message appears if it detects
that the water level is too low.
- This message can be reset from the topside panel with any button press.
Reminder Messages
General maintenance helps.
The display of Reminder Messages can be suppressed by using the PREF Menu.
Reminder Messages can be chosen individually by the Manufacturer. They may be
disabled entirely, or there may be a limited number of reminders on a specific
model. The frequency of each reminder (e.g. 7 days) can be specified by the
Manufacturer.
Press a Temperature button to reset a displayed reminder message.
Alternates with temperature or normal display.
Appears on a regular schedule, e.g. every 7 days.
Check pH with a test kit and adjust pH with the appropriate chemicals.
Alternates with temperature or normal display.
Set ups
Your Hot Tub Parts
CN6013 Circuit Board
Setup #| Circ Pump| Pump 1 Pump 2| Pump 3| Blower Temp
Scale Menu Style
---|---|---|---|---
1| None| 2-Speed| 1-Speed| None| 1-Speed| °C| Standard
2| None| 2-Speed| None| None| 1-Speed| °C| Standard
3| None| 2-Speed| 1-Speed| None| None| °C| Standard
4| None| 2-Speed| None| None| None| °C| Standard
5| None| 2-Speed| 1-Speed| None| 1-Speed| °C| Simple
6| None| 2-Speed| None| None| 1-Speed| °C| Simple
7| None| 2-Speed| 1-Speed| None| None| °C| Simple
8| None| 2-Speed| None| None| None| °C| Simple
9| Programmable Filtration + Polling| 1-Speed| 1-Speed| None| 1-Speed| °C|
Standard
10| Programmable Filtration + Polling| 1-Speed| None| None| 1-Speed| °C|
Standard
11| Programmable Filtration + Polling| 1-Speed| 1-Speed| None| None| °C|
Standard
12| Programmable Filtration + Polling| 1-Speed| None| None| None| °C| Standard
13| Programmable Filtration + Polling| 1-Speed| 1-Speed| None| I-Speed| °C|
Simple
14| Programmable Filtration + Polling| 1-Speed| None| None| 1-Speed| °C|
Simple
15| Programmable Filtration + Polling| 1-Speed| 1-Speed| None| None| °C|
Simple
16| Programmable Filtration + Polling| 1-Speed| None| None| None| °C| Simple
17| None| 2-Speed| 2-Speed| None| None| °C| Standard
18| None| 2-Speed| 1-Speed| 1-Speed| None| °C| Standard
19| None| 2-Speed| 2-Speed| None| None| °C| Simple
20| None| 2-Speed| 1-Speed| 1-Speed| None| °C| Simple
DIP Switch Functions
Fixed-function DIP Switches
A1 Test Mode (normally Off).
A8 in Off position not assigned
A9 in Off position not assigned
A10 in Off position not assigned
A2 In “ON” position, add one high-speed pump (or blower) with Heater.
A3 In “OFF” position, add two high-speed pump with Heater.
A4 In “OFF position, add 4 high-speed pump with Heater.
A5 In “ON” position, enables Special Amperage Rule B. means heater shuts off
when pump is on high speed
A6 Persistent memory reset (Used when the spa is powering up to restore
factory settings as determined by software configuration).
A7 in Off position 1 minute cool down for electric heating on for 5 minute
cool down for gas heating.
WARNING : Setting DIP switches or jumpers incorrectly may cause abnormal
system behaviour and/or damage to system components. Refer to Switchbank
illustration on Wiring Configuration page for correct settings for this
system.
A2, A3 and A4 work in combination to determine the number of high-speed
devices and blowers that can run before the heat is disabled i.e A2 and A3 in
the ON position and A4 in the OFF position will allow the heater to operate
with up to 3 high-speed pumps (or two HS Pumps and Blower) running at the same
time. Heat is disabled when the fourth high-speed pump or blower is turned on.
Note: A2/A3/A4 all off = No heat with any high or blower.
J31 Jumper on 1 pin with 2.0kW or smaller heater Jumper on 2 pins with
3.0kW or higher heater
LIMITED WARRANTY
Canadian Spa Co. Manufacturing extends the following warranties to the
original purchasers of its portable spas:
Structural Warranty: Canadian Spa Co. warrants structure of the spa shell
against water loss due to structural failure for the period of 10 years from
the date of purchase by the original owner. If in Canadian Spa Co. opinion,
structure proves to be defective Canadian Spa Co. will repair or, at its
option, replace the defective structure without charge to the customer Surface
Warranty: Canadian Spa Co. warrants the acrylic finish against defects in
material and workmanship and specifically against blistering, cracking or
delamination for the period of two (2) years from the original purchase date
to the original purchaser. If, in Canadian Spa Co. opinion, the surface proves
to be defective during this period, Canadian Spa Co. will repair or, at its
option, replace the defective spa shell without charge to the customer.
Plumbing Warranty: Canadian Spa Co. warrants the plumbing of the spa will
remain free from leaks for the period of two (2) years from the date of
purchase to the original purchaser.
Equipment Warranty : Canadian Spa Co. warrants the equipment pack (pump,
heater, and control system) against malfunction and defects in the materials
and workmanship for two (2) years from the date of purchase to the original
purchaser.
Skirting Warranty: Canadian Spa Co. warrants the wood skirting
surrounding the spa to be free from defects in materials and workmanship at
the time of purchase. Because wood is a natural product and subject to
weathering, any fading, crazing, cracking or warping of the wood finish is not
covered.
Extent of Warranty: This Limited Warranty applies to portable spas
manufactured after March 31st 2022 and sold by authorised Canadian Spa Co.
dealers to residential retail customers. This Limited Warranty is given only
to the first retail purchaser and terminates upon transfer of ownership.
No warranty is provided on UV lights, light bulbs, light lens covers, filters
or any dealer installed accessories. Cost of installation, removal and/or
shipping of the spa is not covered by this Limited Warranty. In the event
Canadian Spa Co. deems necessary the removal of the spa to a place of repair
or that the spa must be replaced, any and all costs of the spa removal and
replacement; landscaping, decking, fencing and/or structure removal,
alteration and/or replacement; or other costs of providing access to the spa
will be for the purchaser. This Warranty applies only to spas in single
family, residential installations. This Limited Warranty becomes void if the
spa is placed in commercial application.
Guarantee of the insulating cover: Canadian Spa Co. guarantees that the cover
the purchase is free from defects in materials and workmanship.
Where the cover is exposed to strong external influences such as extreme
weather conditions, regular maintenance or protection is essential .
Canadian Spa Co. warrants the cover for the period of two (2) years. Defects
caused by misuse or insufficient care are not covered by the warranty.
TERMS, CONDITIONS AND LIMITATIONS
Any defect or damage caused by installation, alteration or repair by anyone who is not an employee of Canadian Spa Co. or authorised service technician is not covered by the Warranty. This Warranty becomes void if the spa has been subjected to misuse, abuse, alteration or attempted alteration, repairs or attempted repairs by anyone other than an authorised Canadian Spa Co. service technician, improper installation, improper water chemistry, improper maintenance, acts of god, or damage caused beyond the control of Canadian Spa Co. Misuse and abuse shall include any operation of the spas other than as directed in the Canadian Spa Co. Manual.
Examples of misuse and abuse include, without limitation:
- Damage of the spa surface caused by leaving the spa uncovered while the spa is empty of water or due to covering the spa with plastic film of any kind.
- Damage to the spa surface caused by contact with cleaners or solvents.
- Damage caused by the operation of the spas at water temperatures outside of the range of 2 – 40 degrees Celsius.
- Damage caused by unapproved sanitizer such as calcium hypochlorite, tri-chlor type chlorine or any sanitising chemical that may remain undissolved on the spa surface.
- Damage caused by failure to provide even sufficient support for the spa.
Warranty Performance:
In the event of a defect covered under the terms of this Limited Warranty,
notify your authorised Canadian Spa Co dealer. A Canadian Spa Co.
authorised service technician will repair the spa subject to the Terms and
Conditions of this Limited Warranty. Use all reasonable means to protect the
spa from further damage. Reasonable travel charges may be assessed by Canadian
Spa Co. or its authorised service technician if the spa is located outside the
nearest authorised service technician’s service area. This warranty covers
parts ONLY and does not include travel or on-site service charges unless a
Service Contract has been purchased from Canadian Spa Co. Ltd.
Disclaimers :
Canadian Spa Co. or any of its authorised service technicians shall not be
held liable for injury, inconvenience, loss of use, chemical or water damage,
transportation costs, continent liabilities or any other incidental or
consequential costs, expenses or damage as result of any deficiency or alleged
deficiency of the spa. In no event shall Canadian Spa Co. be liable, for any
reason or cause, in excess of the amount paid for the product. No other
warranties, expressed or implied, are valid. No agent, dealer, distributor,
Service Company or other party is authorised to change, modify or extend the
terms of this Limited Warranty in any manner whatsoever.
For Service Support please contact us anytime:
support.canadianspacompany.com
European Head Office:
Canadian Spa Company
Canada House, Salbrook Road,
Salfords, Redhill, Surrey, RH1 5GL,
U.K
T: +44 1293 82409
www.canadianspacompany.co.uk| France
Office:
Alliance SAS
2 Impasse Paul Séjourné
66350 Toulouges
France
T. +33 974 985 119
E: support@canadianspacompany.com|
German Office:
Canadian Spa Company GmBh
Hohenstaufenring 43 – 45
50674 Köln,
Germany
TEL: + 49 22038064038
www.canadianspacompany.de
---|---|---
Canadian Spa Company meets ISO 9001 Standards. When you purchase a hot tub
from Canadian Spa
Company the ISO 9001 Certification assures world class excellence in
manufacturing and customer service.
KM-10235
canadianspacompany.com
References
- AnyRoad: The Leading Experiential Marketing Platform
- canadianspacompany.com/pages/warranty-registration
- Support : Canadian Spa Company
- Hot Tubs, Swim Spas, Replacement Covers - Built for Canadian Winters – Canadian Spa UK
- Canadian Spa GmbH
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>