CANADIAN SPA COMPANY KS-10006 St Lawrence 20 Swim Spa User Manual

May 15, 2024
Canadian Spa Company

CANADIAN SPA COMPANY KS-10006 St Lawrence 20 Swim Spa

CANADIAN-SPA-COMPANY-KS-10006-St-Lawrence-20-Swim-Spa-
image

Specifications

  • Dimensions: 594 x 228 x 137 cm (234 x 90 x 54 inches)
  • Model: KS-10006
  • Power Supply: 50Hz

Product Information

The St Lawrence 20 Swim Spa is a luxurious and spacious swim spa designed for relaxation and exercise. Equipped with safety features, audio/video options, and built-in maintenance guidelines, this spa offers a premium experience for users.

Usage Instructions

Safety Information

When using the swim spa, ensure to follow these essential safety instructions:

  1. Always supervise children closely when using the product to prevent accidents.
  2. Avoid electrical shock risks by not tampering with components or connecting unauthorized devices.
  3. Maintain the spa regularly to ensure safe operation.
  4. Avoid operating audio/video controls while inside the spa.

Important Recommendations

  • Do not sit on the spa cover or place objects on it.
  • Remove any water or debris that collects on the spa cover.
  • Avoid using the spa immediately after strenuous exercise.
  • If you experience discomfort or dizziness while using the spa,
    stop and consult a physician.

Risk Reduction Guidelines

  • Avoid placing electric appliances near the spa to reduce the risk of electrocution.
  • Supervise children at all times and securely attach and lock down the spa cover after each use to prevent drowning.
  • Consult a doctor before using the spa if pregnant, diabetic, in poor health, or under medical care.
  • If feeling uncomfortable, dizzy, or sleepy, exit the spa immediately as heat can lead to hypothermia or unconsciousness.

Frequently Asked Questions

  • Q: How often should I perform routine maintenance on my swim spa?
    • A: It is recommended to conduct routine maintenance once every 3 months to ensure proper operation of the unit.
  • Q: Can I bring objects into the spa?
    • A: Do not bring any objects into the spa that could damage the spa shell. Never insert any object into any opening of the spa.
  • Q: What should I do if I feel pain or dizziness while using the spa?
    • A: If you experience pain or dizziness while using the spa, discontinue use immediately and seek medical advice from a physician.

“`

ST LAWRENCE 20 SWIM SPA
St Lawrence 20′ Swim Spa
Owners Manual 594 x 228 x 137 cm (234 x 90 x 54″) KS-10006
For Service Support please contact us anytime: support.canadianspacompany.com
canadianspacompany.com

ST LAWRENCE 20 SWIM SPA

SAFETY INFORMATION

IMPORTANT SAFETY INSTRUCTIONS When installing and using this electrical equipment be sure to follow these basic safety precautions: 1. WARNING: To reduce the risk of injury, do not permit children to use this product
unless they are closely supervised at all times. 2. DANGER: Risk of accidental drowning. Extreme caution must be exercised to
prevent unauthorised access by children. To avoid accidents, ensure that children cannot use this spa unless they are supervised at all times. 3. DANGER: Risk of injury. The suction fittings in this spa are sized to match specific water flow created by the pump. Should the need arise to replace the suction fitting or the pump, ensure that the flow rates are compatible. Never operate the spa if suction fittings are broken or missing. Never replace a suction fitting with one rated less than the flow rate marked on the original suction fitting. 4. DANGER: Risk of Electrical Shock. Install at least 5 feet (1.5m) from all metal surfaces. As an alternative, spa may be installed within 5 feet (1.5m) of metal surfaces if each metal surface is permanently connected (bonded) by a minimum ground wire. 5. DANGER: Risk of Electrical Shock. Do not permit any electrical appliance such as a light, telephone, radio, television, etc. within 5 feet (1.5m) of a spa unless such appliances are installed and built-in by the manufacturer. 6. ELECTRICAL SUPPLY: The electrical supply for this product must include a suitably rated switch or circuit breaker to open all ungrounded supply conductors to comply with the national electrical standards. This disconnect must be readily accessible and visible to the spa occupant but installed at least 5 feet (1.5m), from the spa water. 7. WARNING: To reduce the risk of injury: a) The water in the spa should never exceed 40°C (104°F). Water temperature between 38°C (100°F) and 40°C (104°) is considered safe for a healthy adult. Lower water temperatures are recommended for young children and when the spa use exceeds 10 minutes. b) Since excessive water temperatures have a high potential for causing foetal damage during early months of pregnancy, pregnant women should limit spa water temperatures to 38°C (100°F) c) Before entering a spa, the user should measure the water temperature with an accurate thermometer since the tolerance of water temperature regulating devices varies. d) The use of alcohol, drugs, or medication before or during spa use may lead to unconsciousness with the possibility of drowning. e) Obese persons and persons with a history of heart disease, low or high blood pressure, circulatory system problems, or diabetes should consult a physician before using a spa. f) Persons using medication should consult a physician before using a spa since some medication may induce drowsiness while other medication may affect heart rate, blood pressure, and circulation.

8. AUDIO/VIDEO EQUIPMENT WARNINGS (Optional equipment based on model) CAUTION: Risk of Electrical Shock. Do not leave compartment door open.
9. CAUTION: Risk of Electrical Shock. Replace components only with identical components.
10. WARNING: Prevent Electrocution. Do not connect any auxiliary components (for example cable, additional speakers, headphones, additional audio/video components, etc.) to system.
11. CAUTION: Risk of Electrical Shock. Do not service this product yourself as opening or removing audio covers may expose you to dangerous voltage or other risk of injury. Refer all servicing to qualified service personnel.
12. CAUTION: Risk of Electrical Shock. When the power supply connections or power supply cord(s) are damaged; if water is entering the audio / video compartment or any electrical equipment compartment area; if the protective shields or barriers are showing signs of deterioration; or if there are signs of other potential damage to the unit, turn off the unit and refer the servicing to a qualified service personnel.
13. This unit should be subject to periodic routine maintenance (for example, once every 3 months) to make sure that the unit is operating properly.
14. CAUTION: Do not operate audio video controls while inside the spa 15. Installation of the spa for other than a residential dwelling will result in voiding
the manufacturer’s warranty. 16. Do not bring any object into the spa that could damage the spa shell. 17. Never insert any object into any opening. 18. WARNING: Do not sit on the spa cover or place objects on it. 19. Remove any water or debris that may collect on the spa cover. 20. WARNING: Do not use the spa immediately after strenuous exercise. 21. If you feel pain or dizziness at any time while using the spa, discontinue use and
contact a physician. 22. WARNING: To reduce risk of injury it is especially important that persons with
pre-existing health conditions or problems such as obesity, heart disease, high or low blood pressure, circulatory problems, pregnancy or diabetes to consult their doctor before using the spa. 23. WARNING: Observe reasonable time limits when using the spa. Long exposures at high temperatures can cause high body temperatures. Symptoms may include dizziness, nausea, fainting, drowsiness, and reduced awareness. These effects could possibly result in drowning. 24. WARNING: The spa jets produce a stream of water with relatively high pressure. Prolonged exposure of localized area of the body may cause bruises to the skin. 25. IMPORTANT: The include warning sign must be posted where all users of the spa can see and read it. 26. WARNING: To avoid risk of drowning. The Spa cover should be in place and properly latched when spa is not in use. 27. IMPORTANT: Read and understand the warnings on the spa cover. 28. Proper water chemistry is necessary to maintain the water and prevent possible damage to spa components.

WARNING
REDUCE THE RISK OF ELECTROCUTION 1. Never place an electric appliance within 5 feet (1.5m) of spa.
REDUCE THE RISK OF CHILDREN DROWNING 1. Supervise children at all times. 2. Attach and lock down spa cover after each use.
REDUCE THE RISK OF OVERHEATING 1. Check with a doctor before use if pregnant, diabetic, in poor health, or under medical care. 2. Exit immediately if uncomfortable, dizzy, or sleepy. Spa heat can cause hypothermia and unconsciousness. 3. Spa heat in conjunction with alcohol, drugs, or medication can cause unconsciousness.
WHEN PREGNANT; soaking in hot water for long periods can harm your fetus. Measure water temperature before entering 1. Do not enter spa if water is hotter than 100ºF (38oC). 2. Do not stay in spa for longer than 10 minutes.

REGISTER YOUR WARRANTY ONLINE
Please be sure to register your swim spa so we can efficiently assist with any questions you may have. Until your spa has been registered, we will not have record of your ownership.
To register your spa, visit: canadianspacompany.com/pages/warranty- registration

SERIAL NUMBER:____Purchase Date:___

(2)

ST LAWRENCE 20 SWIM SPA
St Lawrence 20′ Swim Spa

Delivery Options

Collection Buyer collects swim spa using own transport from our warehouses. Please arrange 96 hours prior to collection
Kerbside Delivery to outside the kerbside of house, customer to be present to sign for the delivery. Customer responsible to removed Swim Spa from truck.
Back Garden Placement Delivery from our warehouse and delivered to customers Swim Spa location. Customer to provide access for position and Crane Check measurements required for each spa.

Cancellation Policy We require a 48-hour cancellation notice in writing or email prior to your scheduled delivery. If we are notified later, then a reasonable cancellation charge will be applied.
Back Garden Placement & Demonstration Delivery from warehouse to customer, on flat bed (Customer supplied crane) then fully installed (including all accessories) and commissioned
(No Electrics). Followed by a maintenance tutorial. Customer to provide access for position.
Check your measurement guidelines for each Swim Spa Optional crane service is available on request

BACK GARDEN DELIVERY FORM
Take your smart phone and tape measure outside with you and attach information directly from your phone! At your convenience upload your information to our site and our experienced delivery team will organize your delivery and installation.

ST LAWRENCE 20 SWIM SPA

1. FILTER BASKET: Assembly that holds the filter cartridge (Note: configurations may differ from model to model).
2. SPA PILLOW: To rest you head and neck (replaceable). 3. AIR CONTROLLER: These are located around the top of your spa.
Increase or decrease the force of your jets by opening or closing the air control valves. 4. ILLUMINATED CUP HOLDER: Placeholder for drinking receptacle. 5. WATERFALL ON/OFF VALVE: Located on top rail of spa used to adjust the waterfall flow. 6. LED ILLUMINATED SPEAKER: Audio speaker system for playing music from an MP3 device 7. AROMATHERAPY: A small canister that holds scented beads and works in conjunction with the air control system to create an aromatic experience. 8. AUDIO VOLUME CONTROL: Allows control of functions from within the Swim Spa connected Bluetooth (6 button control). 9. TOPSIDE CONSOLE: Button pad and temperature display panel located on the top of the spa into which various commands, control sequences and options for operating the

spa can be input. User can set temperature, filtration cycle and heating mode through the console. 10. SUCTION FITTING: Located at the bottom of the spa, used to return water back into the filter and pump system. 11. JET (VARIOUS): Device that ejects air and water, creating water movement in the spa. Adjustable, directional, rotational and interchangeable. 12. WATERFALL & PERIMETER LIGHTING: For a relaxing spa mood. 13. VACUUM BRAKE: Ensures the suction inside the spa is cut off immediately if blocked. 14. LARGE DIVERTER: Diverts the flow of water from one jet zone to another. 15. MAIN SPA LIGHT 16. DRAIN OUTLET 17. SWIM JET AIR CONTROLS 18. SWIM JETS 19. TETHER POINT: Allows you to tether a swim pole in order to give extra resistance when swimming against the flow of the jets.

HOW JETS WORK Air is mixed with the water by using the air controls to create massage(s) of varying degrees. Water flow is adjusted by simply turning the outer face of the full sized jets. Our Swim Spas have a combination of pulsating, rotating, and directional adjustable jets.

2.25″ Directional jet Adjustable and interchangeable jet features a directional nozzle. The jet can be removed by turning it counter-clockwise. To replace the jet push inward and clockwise until it clicks into place.

Air Controller These are located around the top of your spa. Increase or decrease the force of your jets by opening or closing the air control valves.

2.25″ Twin Roto jet Adjustable and interchangeable jet spins and pulsates. The jet can be removed by turning it counter-clockwise. To replace the jet push inward and clockwise until it clicks into place.

3″ Directional jet Adjustable and interchangeable jet features a directional nozzle. The jet can be removed by turning it counter-clockwise. To replace the jet push inward and clockwise until it
clicks into place.

Waterfall control
Located on the topside of the spa, this valve adjusts water flow to the waterfall.

5″ (Jumbo) Directional jet Adjustable and interchangeable jet features a directional nozzle. The jet can be removed by turning it counter-clockwise. To replace the jet push inward and clockwise until it clicks into place.

3″ Massage jet Rotational and interchangeable jet which spins to deliver a soothing massage. The jet can be removed by turning it counterclockwise. To replace the jet push inward and clockwise until it clicks into place.

Aroma basket cap Open cap to place aromatherapy beads. Close after use.
(4)

5″ Massage jet Rotational and interchangeable jet features an internal spinner to deliver a low pressure soothing massage. The jet can be removed by turning it counter-clockwise. To replace the jet push inward and clockwise until it clicks into place.

LED Pop-up speaker

ST LAWRENCE 20 SWIM SPA
Swim Spa equipment side
Slice valves

LED Pop-up speaker

2.5″ Pump union

Pump 2

Ozone Heater Control

MP3 2.5″ Pump

Generator

pack Amplifier union

Pump 1

CONTROL PACK: Unit that controls spa operations, containing electronic programming boards, heater and all connections for Pump(s), Light(s), Ozone Generation Unit and Topside Console. Also referred to as Spa Pack’ or Controller’.
HEATER: Electrical resistance device located in the Spa Controller containing the heating element and 2 temperature sensors. The flow through heater heats the spa’s water as it flows across the heating element. Heaters are available in several wattages.
MASSAGE PUMP: Electro-mechanical device to move water, consisting of a wet end and a motor. OZONE /UV GENERATOR: Device that generates ozone to aid in maintaining water quality. Generates Ozone and UV to help eliminate organic material such as body oils, dead skin cells and hair.
DRAIN VALVE: Valve located on the outside of spa cabinet used to drain water from the spa. A garden hose can be attached to the drain valve.
EQUIPMENT BAY: Located under the spa shell covered by access panels that houses the spa controller and equipment.
SLICE VALVE: Two-position (open or closed) sliding valve, used to cut off water flow which allows for service to be performed on the spa equipment without the need to drain the spa. Slice valve operations: up for open, down (toward the valve body) for closed.

Swim Spa side view

(5)

UV Light WS T aL AtWeRrE NTC Ere2 0aStWmI M eS PnAt System

· Input Voltage: AC 230V 50/60 HZ · Operating Current: 100mA · Power: 15W

· Purification of water: 15L / Minute · UV Lamp Lifetime 6000-8000 Hr · Replace UV Lamp Annually

canadianspacompany.com

IMPORTANT: 1) Turn off the power. 2) Allow the UV Lamp to cool before replacing. 3) Do not look at lit Lamps to avoid eye damage.
Step 1: Turn both red vales off horizontal position (as photos below) to isolate the UV Silver chamber.

How to change the Black Ice UV Lamp & Tube
To replace UV Light Lamp Only
Remove pressure fit end and replace Lamp. The end of the Lamp has 4 pins that fit into 4 pin plug, there will be no water as the clear quartz tube is sealed in UV Chamber, replace end and put back in and turn on valves.

Black Ice UV Kit KK-11216
UV Quartz Glass Tube & `O’ ring

To replace UV Quartz Glass Tube & UV Light Lamp.
Follow UV Lamp replacement but before installing new UV Lamp unscrew end off UV Chamber and you will find a Quartz glass tube and a O’ ring – replace tube and putO’ ring near the top of the Tube, insert into chamber and screw back metal end, then install new UV Lamp. (Make sure to use gloves).

UV 15w Lamp & Gloves

How to change Canadian Spa Wave Zone Lamp
IMPORTANT: 1) Turn off the power. 2) Allow the UV Lamp to cool before replacing. 3) Do not look at a lit UV Lamp to avoid eye damage.

ON

OFF

Turn both red vales off horizontal position

(see photos opposite) to SHUT OFF the

water and isolate the UV chamber.

Step 1: Unscrew the 2 red-marked screws.

Step 2: Remove the red lid Step 3: Unplug this white Step 4: Take out this black

connector

protective sleeve

Step 5: Pull out the Lamp to Step 6: Put the Lamp inside Step 7: Plug in the white Step 8: Cover the red lid and

change it

the metal tube and cover it

connector

install these 2 screws

with black protective sleeve

Wave Zone UV Lamp Kit
KK-11202 The Advanced Oxidation Process is used in Canadian Spa Company’s Swim Spas. Combining our Ozone Generator with Ultra Violet Light creates a unique bacteria fighting superhero: Super Hydroxyl Radicals. They easily overcome even the most powerful of bacteria.

NORMAL OPERATION

REMINDER NOTIFICATIONS

NEEDS ASSISTANCE

Spa Status LED (Optional)
Our new Spa Status LED provides convenience, right at your finger tips. Check the status of your spa by looking at the colour of the LED light from afar ­ no more breaking your back trying to remove your cover just to see if your spa is running!
(6)

ST LAWRENCE 20 SWIM SPA
Pre-Delivery Information

X

Before delivery check your spa height and width and add 5cm clearance on each side to ensure
access.

Check that the Swim Spa can clear a 90° turn

Access: Canadian Swim Spas tubs are usually delivered on a flat bed trailer, up to 5 metres long, 2.4 metres wide and 3.5 metres high. Please ensure that there is adequate access for such a vehicle to reach your property. When off loading from our vehicle to the spa site, a minimum of 1100mm width is required, (some models vary) this also needs to be flat and a minimum clear vertical height of 9ft should be considered also.
Electrical supply: If you are having your spa installed, it will be necessary to have a dedicated electrical circuit supply fitted. You will require up to 32 Amp (type C Breaker) supply, dependent on the length from the service point. Your spa must be protected via a RCD and suitable over current protection.
A minimum of 5 metres of cable is required for connection into your spa from the Isolator.
Electrical installation: Arrange for a licensed electrician run the required 230-volt power line to the spa installation site. This power line must be permanently connected (hard-wired) to the mains supply. Do not use extension cords or plug-in type connections. At the site where the spa is to be located leave 5 metres of cable and the appropriate cable gland. All electrical wiring to a spa must be installed by a qualified, licensed electrician, and meet required electrical standards.
Water: The best means of filling your spa is with a garden hosepipe (use cold water not hot water). Please ensure that you have one readily available. If you are aware that your water pressure is poor, we should be advised prior to delivery. The design of our spas allows for easy drainage, again, using the hosepipe which conveniently fits onto the drain valve situated at the base of your spa. Ideally, you should empty the water to a nearby drain. You may wish to purchase a suitable submersible pump to speed up this process.

Rotary Isolation Switch (pictured). Make sure you have a qualified electrician prepare
the electrics. Allow 5 metre slack to connect to Spa.

Ensure you have prepared a level concrete base or a properly fitted existing patio or decking with access to a drain.

NOTE: A 10-15 cm concrete base is ideal preparation for a Swim Spa.
Decking around your spa: Ensure that you are aware of the above measurements. Always consider during your planning that any decking boards and supporting beams that you install allow access to the sides of your Spa. It is the customers’ responsibility to ensure that any decking is clear of these areas prior to any visit by our technicians (Allow 1 metre clearance around your Swim Spa and if you have decking ensure part of your decking can be removed in order to gain access for future repair or servicing). If you are unsure then please ask before ground construction and the delivery of your spa. Your spa must be sited on a solid, flat, level base which is the same size or larger than the spa. The base can be either a 10-15cm concrete slab or suitably strengthened timber decking or existing patio area assuming it has suitable foundations of hardcore. Whatever base area is chosen, it must be of suitable load bearing capacity. Please ensure your base has suitable drainage.

Ensure part of your decking can be removed in order to gain access for future repair or servicing
Optional CraneService is available

(7)

ST LAWRENCE 20 SWIM SPA

Filling up your Spa
IMPORTANT: Before filling the spa, it is important to read and understand the water chemistry section of this manual. Do not proceed until the water chemistry section is understood and the source water is tested.
Verify that the spa is in the desired final location. Once filled, the spa cannot be moved without draining.
Follow these filling instructions to avoid damage to the spa pumps: 1. Leave power to the spa off until spa is completely filled. 2. Never leave an unfilled spa exposed to direct sunlight with
out the Spa Cover installed. Resulting damage such as bubbles and wrinkles in the spa shell and fading of the jet faces is not covered by the manufacturer’s warranty.
3. Never operate spa pump without water because this could result in permanent pump and/or heater damage which is not covered by the manufacturer’s warranty.
4. Remove all warning labels from spa shell. 6. Remove the filter lid, basket and filter cartridge.
7. Inspect all Jets (shipping may cause jets to become loose or detached). Check to see that the black Drain Valve (located to the left or right of the front access panel) is closed.
IMPORTANT: Follow the next steps closely to prevent damage to the Spa Pump.
Filter Type: Glacier Antimicrobial Filter 4 pack KA-10009

Draining your Spa/Using drain valve
IMPORTANT: Before draining your spa shut off the electrical breaker connected to the spa.

1. Inset closed position. (Push in to release internal O-Ring seal prior to Step #2)

2. Extended closed position )pull out to fully extended position and remove cap); place cap in safe place.

3. Full extended closed position (attach garden hose in
the full extended closed position).

4. Open position for draining (turn hose and fitting ¼ turn clockwise and insert ½ way to open position for draining).

8. Insert garden hose or other clean water source directly into filter housing. Push hose pipe into filter housing until it stops. Fill up to top of the skimmer Secure hose placement and turn on water. Filling the spa through the filter housing prevents an air lock from occurring in the spa pump, which is an air pocket preventing the flow of water through the pump. Permanent damage caused by running the pump with an air lock or without water) is not covered by the manufacturer’s warranty.
9. Check for leaks! Although spas are fully checked at the factory, shipping and delivery might cause a leak.
10.Before power is applied familiarise yourself with the spa control operations.
11. Turn water off and remove hose. 12. Reinstall filter cartridge, basket and filter lid.
13. Add start-up Chemicals after power is turned on.

5. Open position for draining (turn hose and fitting ¼ turn counter clockwise and pull out to full extended closed position).

6. Full closed extended position (remove hose and
replace cap).

7. With replaced cap screwed on, turn ¼ turn clockwise and

8. Closed inserted position.

push in all the way to inserted

closed position.

Accessing your spa controls

To access the Control Pack undo the 4 screws on both panel strips

(8)

ST LAWRENCE 20 SWIM SPA

Installation: Electrical power requirements

Power connections

ELECTRICAL REQUIREMENTS FOR SWIM SPAS

Single Phase (A) is the normal wiring configuration for most household electrical installations (3 wires: live, neutral and earth). If however you

have insufficient Amps you will need to use other connection (see below). 2 Single Phase connection (B) is used in circumstances where the

power supply is limited and where you need more Amps. 3 Phase (C) is used in certain areas of Europe where 3 Phase power is available and

the installation warrants it. NOTE: Canadian Spa Company requires that the electrical installation of your Swim Spa is carried out by a

professionally licensed electrician and that all local electrical and building codes are adhered to.

CONNECTING SWIM SPA TO RCD AND CONSUMER PANEL:
· All Swim Spas must be wired with the appropriate sized wiring. Failure to do so will cause equipment damage and will not be covered by your warranty
· All Swim Spas must be protected with a appropriately sized RCD (Residual Current Device) in the consumer panel. Have your electrician verify using the diagram opposite.

ADDITIONAL ITEMS NEEDED TO HELP COMPLETE ELECTRICAL CONNECTION:

1. RCD Breaker, 2. Electrical cable (check length and width for amperage and distance), 3. Cable gland. 4. Tidy clips

A.) Single Phase connection (most common): Single Phase (live 1, neutral 1, live 2, neutral 2, ground)] 230VAC, 50/60Hz, 2þ, 16A, (Circuit Breaker rating = 20A max each phase line.)
Consumer panel RCD Breaker
Swim Spa control

PUMP 1 J56 J57 J55 J59

J31=CE HTR SEL

J6 J
K2

F6 30A J60 J41
3

J52

J51

TB1 1

J12 J4 J42

J36 J37 J72

2

1

3

2

4

J53

J

5 9 4 7 5 8

0

PUMP 1 J56 J57 J55 J59
A/V HOT J81
F2 10A 250VAC CIRC PUMP J20 OZONE
F7 10A 250VAC J18
AUX**

J25=HTR1

J26=HTR2

J9

J33 K9

J32

J27=HTR3

K4

J13 K6

J30=TEST

J46

J31=CE

J38

HTR

SEL

K2 F6 30A
TB1 1 2

J39

J60 J41

J10 J43 K12
F8 30A

J51 J52 J98

1

J109

F3 0.3A SLO-BLOW

K1

K8 J19
230V J24
115V 115V T1

K3

2

J49 J44 J48

J37 J72 J4 J42 J1 J3 J47 J61

3 4
4

J36 J12 J88 J62

K5 3 J53 J58
J111
J11

2

3

J15

LIGHT

K7

F4 3A SLO-BLOW

GND ON S1

J110 J45 J79 J54 J77 J75 J78

J6 J7

J50
J34 J35 MAIN MAIN

J108 J107 J91

J5 AUX

J101 J27 J23

J22

SERIAL

J26 J30

J25 J31
J29 VAC

J8 AUX J40
REMOTE

10 J17 J16
AUX J28 FRZ

(9)

ST LAWRENCE 20 SWIM SPA

Installation

B.) 2 x Single Phase
(live 1, neutral 1, live 2, neutral 2, ground)] 230VAC, 50/60Hz, 2þ, 16A, (Circuit Breaker rating = 20A max each phase line.)
In 2x16A Service: Pump 2 (if any) and the Heater are on one service. Everything else is on the other service.
For 2-Wire connection: 1.Completely remove jumper on J51 and J88. 2.Completely remove jumper on J52 and J62. 3. Make a connection between jumper J60 andJ36 4. Make a connection between jumper J41 and J12 5. Make a connection between jumper J46 and J75 6. Make a connection between jumper J20 and J77 7. Make a connection between jumper J38 and J54 8. Put DIP switches A2, A3 and A5 on ON

C.) 3-Phase 5 wires (live 1, live 2, live 3, neutral, ground)] 400VAC, 50/60Hz*, 3þ, 16A, ( Circuit Breaker rating = 20A max each phase line.)
In 3x16A Service: Pump 2 is on one service. The Heater is on another service. Everything else is on the remaining service.
For 3-phase connection: 1.Completely remove jumper on J51 and J88. 2.Completely remove jumper on J52 and J62. 3. Make a connection between jumper J60 andJ45 4. Make a connection between jumper J41 and J79 5. Put DIP switches A2 and A3 on ON and DIP switch A5 on OFF.

POWERING UP YOUR SPA Once the spa is properly wired and filled with water, the spa power can be turned on and Start-up chemicals added.
1. Turn on RCD breaker. If breaker trips immediately check Neutral and Ground Wire connections. Upon initial power up, 4 sets of numbers flash on the LED display of the topside Console. The last number in the sequence is the incoming power meter which can be used to verify that the spa is wired correctly.
2. The spa begins an automatic priming routine which will last 6 minutes (“Pr” is on the LED display).
3. The priming routine will automatically run each spa pump to prime. When the “Pr” is displayed, press any PUMP button to prime that pump or wait for the priming routine to turn on the Pump. IMPORTANT: To avoid pump damage, do not run pumps for more than 1 minute without moving water. If no water is moving, turn the power off and perform air lock procedure.
4. The Topside Console display flashes “38C/100F” then press “–C/F” for approximately 2 minutes to determine water temperature as it flows through the heater.

5. The default pre-set temperature is 36.5°C. The last measured temperature is constantly displayed on the LCD readout. This temperature will be current only when the pump has been running for at least 2 minutes. Set the desired temperature between 26- 40°C (80-104°F) by pressing the temp button(s). If the water temperature is below the set temperature, the spa’s heater and heat indicator light will turn on. All features of the Topside Console will be available. The spa will heat approximately 1° every 30 minutes per 1,000 litres.
6. Check for leaks! Although spas are fully checked at the factory, shipping & delivery might cause a leak. Remember to pay particular attention to barrel unions adjoining the heater. Contact your Canadian Spa dealer directly if there is a problem.
If your new spa pump does not prime (flow) on the initial start-up you may be experiencing an “air lock”.
This normal occurrence can be easily corrected by loosening the plumbing union on the suction side of the Jet or Pump until water flows into the pump and all air is expelled.
PRESS BUTTONS SLOWLY FOR FIRST RUN WHEN STARTING UP
ONCE PR EXITS, SET TEMPERATURE ON SPA (SEE SPA OPERATION SECTION FOR DIFFERENT SPA TOPSIDES)

(10)

ST LAWRENCE 20 SWIM SPA
How your spa functions

DRAIN VALVE

AO3P AO P ³
UV SYSTEM

OZONE LINE
CHECK VALVE

PRE-FILTER REMOVES
Debris

OZONE MIXING CHAMBER

MAZZEI INJECTOR PUMP

T VALVE

CONTROL HEATER

T VALVE

ANTI-BACTERIAL FILTERS INHIBITS BACTERIAL GROWTH

ATTACHING YOUR SPA COVERS 2 PIECES The Spa Cover is an important accessory to help preserve the spa’s temperature. The Spa Cover also serves as a safety device, preventing unauthorized users from entering the spa. Proper installation of the Spa Cover is an important addition in the spa installation. 1) Remove Spa Cover from packaging. 2) Place Spa Covers on SWIM SPA in order to allow easy access to the topside console when opening the cover. 3) Line up attaching straps and secure with mounting hardware and use locking mechanism to lock Spa Covers in place.
IMPORTANT: Always lock Spa Cover in place when not using the spa. Do not walk or sit on Spa Cover. Remove snow build-up to avoid breaking the foam inner core. Do not drag Spa Cover on rough surfaces.
Optional Rolling Cover KC-10252 The Roll On Roll Off cover is made from carbon fibre making it 25% lighter than other rolling spa covers, resulting in super easy use for anyone. In fact, they are designed to enable one person to roll the cover off in less than a minute. This cover is cleverly designed to have built-in eyelets that allow air to escape as is rolls up so it does not get bigger and bigger.

Basket cover lifter KA-10061
· Ideal for Swim Spas · Mounts directly to spa · Aluminium · Fits up to 94″ wide spas · Requires 12″ clearance

TOP MOUNT SWIM SPA COVER LIFTER Fully compatible with ALL our Canadian Spa Swim Spas and spas and most other brands; this Cover Lifter is the ideal choice to complement your Swim Spa, making cover removal and replacement a quick, one-handed operation and reducing wear and tear. · Low-profile design · Virtually zero clearance required behind spa ­ great for tight spaces
(particularly if your spa is located in a gazebo) · Mounts directly to the spa · Fits up to 2.4m Spas · Made of Aluminium
(11)

ST LAWRENCE 20 SWIM SPA
2 Pump Control System (TP600)
Initial Start-up When your spa is first activated the display will do a count sequence of M100, L232, V52, 1-3 afterwards a message will display `RUN PUMPS PURGE AIR’ on Priming Mode
JETS Activates jets
Pump 1

TEMP UP Increase Temperature

JETS Activates jets
Pump 2
JETS Activates jets
Pump 3

LIGHTS On/Off/ Light modes
TEMP DOWN Decrease
Temperature

Display Symbols

Pumps Press the “Jets 1” button once to turn pump 1 on or off, and to shift between low- and high-speeds if equipped. If left running, the pump will turn off after a time-out period. The pump 1 low-speed will time out after 30 minutes. The high-speed will time out after 15 minutes.
The low-speed of pump 1 runs when the other pump is on. If the spa is in Ready Mode, Pump 1 low may also activate for at least 1 minute every 30 minutes to detect the spa temperature (polling) and then to heat to the set temperature if needed. When the low-speed turns on automatically, it cannot be deactivated from the panel, however the high speed may be started.

Temperature and Temp Range
Adjusting the Set Temperature When using a panel with Up and Down buttons (Temperature buttons), pressing Up or Down will cause the temperature to flash. Pressing a temperature button again will adjust the set temperature in the direction indicated on the button. When the LCD stops flashing, the spa will heat to the new set temperature when required.

Pressing the button again will cause the temperature to change in one direction (e.g. UP).

TEMPERATURE UP

TEMPERATURE DOWN

Pumps 2 and 3 Jets 2 and 3 button once to turn pump 1 on or off
Filtration and Ozone Pump 1 low and the ozone generator / UV will run during filtration. The system is factory-programmed with two filter cycles that will run 10 minutes after power-up. The filter duration is programmable.
Freeze Protection If the temperature sensors within the heater detect a low enough temperature, then the pump automatically activate to provide freeze protection. The pump will run either continuously or periodically depending on conditions.
In colder climates, an optional additional freeze sensor may be added to protect against freeze conditions that may not be sensed by the standard sensors. Auxiliary freeze sensor protection acts similarly except with the temperature thresholds determined by the switch. See your dealer for details.
Clean-up Cycle When a pump is turned on by a button press, a clean-up cycle begins 30 minutes after the pump is turned off or times out. The pump and the ozone generator will run for 30 minutes or more, depending on the system.

After allowing the display to stop fl ashing, pressing the Temperature Button will cause the temperature to flash and the next press will change the temperature in the opposite direction (e.g. DOWN). The temperature can be set between 16°C and 40°C (60°F and 104°F).
Press-and-Hold If a Temperature button is pressed and held when the temperature is flashing, the temperature will continue to change until the button is released. If only one temperature button is available and the limit of the Temperature Range is reached when the button is being held, the progression will reverse direction.
LIGHTS Press light button to turn on and off the lights. Each consecutive press will alternate through different lighting modes and colours.
MENU Press light button then temp up to access different features and filtering options.
Priming Mode will run for approximately 5 minutes (Press TEMP-UP to skip Priming Mode) then the spa will begin to run Jets on low speed and after a few minutes the heater will start when in `R’ (Ready Mode).

(12)

ST LAWRENCE 20 SWIM SPA
Chemical Guide

FREE Water Test App

Starter Chemical Kit
KA-10122

Deluxe Chemical Kit
KA-10089

Spa Flush
Annually flush the spa to remove bio-film that has attached to the interior of the spa pipes.
KA-10164

Chlorine Granules – Disinfection
To protect your health, ensure that your spa water is disinfected thoroughly on a regular basis. This is particularly important in spas, as the high water temperatures provide an ideal breeding ground for bacteria. To prevent water care problems, there must always be sufficient levels of disinfectant in the water.
The use of Chlorine granules is the traditional method of disinfecting spas. Chlorine granules dissolve quickly, without residues, and do not bleach the surfaces. The granules are pH-neutral, i.e. the pH value of the water does not change with the dosing of the granules. Check the pH value using the 3 function test strips at least once a week, and, if necessary, adjust it to 7.2 ­ 7.6. Add 10 g/m³ of Chlorine granules after each bathing session. Let the circulation pump run for 10 minutes, and then check afterwards using 3 function test strips that the ideal value of 1.0 ­ 1.5 ppm (mg/L). is reached. If necessary, continue to dose. The granules are dosed directly into Swim Spa water. KA-10123

pH Up and pH Down
The pH value is the basis for reliable disinfection. The care products only work perfectly when the levels are correct, meaning the water is not harmful to skin, hair or eyes. The ideal pH value is between 7.2 and 7.6. The pH value is influenced by various factors. For example it increases when fresh water is added. Increasing the water temperature or using the jets changes the pH value. Therefore, check the value at least once a week and, if necessary, increase the levels using pH Up or decrease with pH Down. The granules are dosed directly into the spa water. pH Up: KA-10051 / pH Down: KA-10050
Scale Control
The overall hardness is a measure of the amount of calcium and magnesium in the water. Scale Control prevents calcium precipitations forming on the walls and in the pipes of your spa. You can find out the overall hardness level of your water by contacting your local water supplier. With a level over 200 ppm (mg/L)., heating the water can cause lime-scale deposits on the walls, creating rough surfaces. To prevent lime-scale deposits, always use Scale Control after refilling. KA-10055
Test strips
Canadian Spa 3 Way Test strips to check the levels of Chlorine, PH and Total Alkalinity. Simple and easy to use. Ensure your spa is always safe to use. Pack of 50 strips. Dip a test strip into the water and compare to the colour chart to take readings for: – Chlorine, pH, Total Alkalinity. TIP: Chlorine and pH should be checked EVERY TIME the spa is used to ensure that the water is safe to use! Go to App, put in your test results and it will tell you what to add and how much. KA-10052
(13)

Foam Free
If your spa water has a tendency to foam, then we recommend you add Foam Free. The product is added directly to the spa water. If the water continues to foam, even after the product has been added, replace the water. KA-10054
Alkalinity Booster
Alkalinity booster will prevent erratic changes in the pH level of the spa/Swim Spa water. Alkalinity Booster will help the bromine or chlorine in the spa/Swim Spa work more efficiently. Alkalinity Booster raises the total alkalinity of the spa/Swim Spa water preventing any corrosion that could be cause by low alkalinity. KA10146
Spa Clear
Super highly Concentrated Clarifier · Adds brilliance back to spa water · Aids filter in removing suspended
particles · Non-toxic. Will not affect pH level. · Reduces chlorine demand when
used regularly · Restores water clarity KA-10053

PROBLEM CLOUDY WATER
COLOURED WATER FOAMING SCALE DEPOSITS ODOUR EYE/SKIN IRRITATION NO CHLORINE/ BROMINE READING

ST LAWRENCE 20 SWIM SPA

TROUBLESHOOTING GUIDE

POSSIBLE CAUSE

SOLUTION

A) organic contaminants build-up
B) suspended particles C) pH high
D) total alkalinity too high E) poor filtration
F) high dissolved solids

A) shock treatment with Granular Chlorine B) add Granular Chlorine, use SPA- BALL C) add pH DOWN until pH level reads 7.2­7.6 D) add pH DOWN, adjust total alkalinity to 80­150 p.p.m. E) dirty filter, replace filter F) empty spa and refill

Debris in water

Use Chlorine Granules.

High concentration of oils and organic contaminants being agitated by jet

Squirt FOAM-FREE on foam. Use the SPA-BALL

High calcium level, high pH, high alkalinity

Drain partially, add Granular Chlorine, correct pH level to 7.2­7.6 and alkalinity to 80­150 p.p.m.

High level of organic contaminants combined chlorine. Shock with Granular Chlorine Chlorine level too high

A) pH too low B) combined chlorine due to high concentration
of organic contaminants

A) add pH up until level is 7.2­7.6 B) shock with Granular Chlorine, add disinfectant

A) high concentration of organic contaminants using up sanitizers
B) test trips may be ineffective

A) add Granular Chlorine B) replace at least once a year, keep cool
and out of sunlight

Low PH and low-quality chlorine causes the heater
element to calcify

pH LOW
· Reduced efficacy of disinfection · Corrosion of metals · Skin & eye irritation · Unpleasant odour

pH SCALE pH NORMAL
7.2 -7.6

pH HIGH
· Reduced efficacy of disinfection · Skin & eye irritation

Helps to keep your spa clean and achieve crystal clear water!

· Forms limescale deposits · Staining of the filter

Canadian Spa Company Spa Ball KA-10003

Chemical Video Guides on Canadian Spa Company channel

ST LAWRENCE 20 SWIM SPA

DIP Switch Functions Fixed-function DIP Switches A1 Test Mode (normally Off).

A8 in Off position not assigned A9 in Off position not assigned A10 in Off position not assigned

A2 In “ON” position, add one high-speed pump (or blower) with Heater. WARNING: Setting DIP switches or jumpers incorrectly may cause abnormal

system behaviour and/or damage to system components. Refer to Switchbank

A3 In “OFF” position, add two high-speed pump with Heater.

illustration on Wiring Configuration page for correct settings for this system.

A4 In “OFF position, add 4 high-speed pump with Heater.
A5 In “ON” position, enables Special Amperage Rule B. means heater shuts off when pump is on high speed
A6 Persistent memory reset (Used when the spa is powering up to restore factory settings as determined by software configuration).

A2, A3 and A4 work in combination to determine the number of high-speed
devices and blowers that can run before the heat is disabled i.e A2 and A3 in
the ON position and A4 in the OFF position will allow the heater to operate with up to 3 high-speed pumps (or two HS Pumps and Blower) running at the same time. Heat is disabled when the fourth high-speed pump or blower is turned on.
Note: A2/A3/A4 all off = No heat with any high or blower.

A7 in Off position 1 minute cool down for electric heating on for 5 minute cool down for gas heating.

Airlock warning messages

If you receive any of these error messages on your spa you could have an airlock: FLO

How to release an airlock
Air Lock Release Valves To bleed air from the pump valves (see photo opposite): · Turn one of these valves slightly until you can here a hissing noise · Once water comes out tighten the valve back up, pump has been bled of the trapped air

If your spa pump does not prime (flow) on the initial start-up you may be experiencing an “air lock”.

This normal occurrence can be easily corrected by loosening the plumbing union on the suction side of the Jet or Pump until water flows into the pump and all air is expelled.

PRESS BUTTONS SLOWLY FOR FIRST RUN WHEN STARTING UP ONCE PR EXITS, SET TEMPERATURE ON SPA

(14)

(15)

ST LAWRENCE 20 SWIM SPA

Settings 2 x Pumps standard & Simple Options

Press Menu (Temp Up then Light) button until you reach the mode you require.

– Press Temp Up-to restart or wait for the minute HOLD to end.

TEMP
– Temp Up button ­ until arrow is either pointing up or down. (Arrow up will maintain heat / Arrow down will drop the temp by 10 degrees.)
– Menu (Temp Up then Light) to select.
MODE
– Temp Up button ­ press until either Ready or Rest is displayed (Ready maintains its set temperature / Rest will only heat within the filtration cycles)
– Menu (Temp Up then Light) to select.
SET TIME (Not used with Simple Option)
– Temp Up button ­ hour will flash on display. · press Temp up button until desired hour.
– Menu (Temp Up then Light) to select ­ minutes will flash. · press Temp Up button until desired minute.
– Menu (Temp Up then Light) to select.
FLIP
– Temp Up button ­ will invert the display so it can be seen in spa.
– Menu (Temp Up then Light) button to select.
LOCK
Panel Lock – Temp Up button ­ PANEL will be displayed.
· Temp Up button – cycle between On and Off. · Once ON is displayed press MENU (Temp Up then Light) button to select. (The buttons on topside panel will now be unresponsive) Temp Lock – Temp DOWN button ­ TEMP will be displayed. · Temp up button ­ cycle between On and Off. · Once ON is displayed press MENU (Temp Up then Light) to select. (The Temperature buttons will now be unresponsive ­ jet buttons will work)
UNLOCK
– Press and hold down TEMP UP while you press the MODE Button 2 x Slowly. (Topside panel is now unlocked and normal operations enabled)
HOLD
– Temp Up button ­ `HOLDING FOR 1:00′ will be displayed. (Pump/s will shut down for 1 minute to allow time to replace filters)

FLTR 1 (Set 1 -12 hours every 12 hours on simple)
– Temp Up button ­ BEGN will be displayed. – Temp Up button ­ Hour will be flashing.
· Press Temp Up button to cycle to the hour preferred to start.
– Menu (Temp Up then Light) to select ­ minutes now flash. · Temp Up to adjust the minutes ­ goes up 15 minutes with every press.
– Menu (Temp Up then Light) to select. RUN HRS is then displayed.
– Temp Up button ­ press to how many hours you would like the filtration cycle to run. (recommended filtering cycle – 4 hours twice a day)
– Menu (Temp Up then Light) to select. · Minutes ­ press TEMP Up button ­ goes up in 15 minutes every press.
– F1 ENDS – Menu (Temp Up then Light) to select.
FLTR 2 (Not used with Simple Option)
– Temp Up button ­ OFF will be displayed press Temp Up for it to be ON
– Menu button to select. – Temp Up button ­ BEGN will be displayed. – Temp Up button ­ Hour will be flashing.
· Press Temp Up button to cycle to the hour preferred to start.
– Menu (Temp Up then Light) to select ­ minutes now flash. · Temp Up to adjust the minutes ­ goes up 15 minutes with every press.
– Menu button to select. – RUN HRS is then displayed. – Temp Up button ­ press to how many hours you would
like the filtration cycle to run. – Menu (Temp Up then Light) to select.
· Minutes ­ press TEMP Up button ­ goes up in 15 minutes every press. – Menu button to select. F2 ENDS ­ press MENU (Temp Up then Light) to select.
PREF
Service tech
UTIL
Service tech

(16)

ST LAWRENCE 20 SWIM SPA

Trouble shooting

ISSUE · No power
· RCD trips

POSSIBLE CAUSE
Breaker or RCD off Loose wire connection Mis-wired Component failure

· Heater not operating or spa not heating
· Pump not operating or turns off after a short time

Temperature set to low Water level too low Blown fuse Component failure
Air lock Improper voltage to pump Time out
Component failure Thermal overload

· Pump surging · Light will not turn on · Ozone Generation Unit will not
operate · No water Flow from Jets
· Jet popped Out · No air flow from jet
· Noisy Pump or Motor
· Spa Overheating
· Spa will not turn off · Abnormal water · Water not clean

Low water level Burned out bulb Light bulb may have fallen out Blown fuse Burned out UV bulb Component failure Air lock Adjustable jets turned off Faulty pump or motor Slice valve closed Clogged filter Jet face not seated
Broken jet Adjustable jets turned off Air control valve not open Broken jet Jet not seated properly Air lock Low water level Clogged filter Damaged or warn motor bearings High ambient temperature
Filtration duration Spa is trying to heat
Spa is on high filter cycle Excessive evaporation Excessive splashing Dirty or clogged filter Poor water chemistry Insufficient filtration Cycle duration High solids content

SOLUTION
Check that RCD breaker is turned ON Check wire connections
Check wiring per diagram, especially neutral wire Perform elimination test to determine failed component. See elimination test section
Set temperature above current water temperature Add water until water level is 1 inch (25mm) above Water Line Check 30amp bus fuse on control board Contact dealer
See Air lock procedure (Page 12) Contact dealer or qualified electrician As a safety precaution, the Spa Controller only allows Pump operation for 15 minutes continuously Contact dealer or qualified electrician During extreme high ambient temperatures the pump motor may reach the motor thermal overload limit. Wait until motor cools and retry. If problem persists contact dealer
Add water until water level is 1 inch (25mm) above water line Change bulb Unscrew back housing and reinsert bulb Check Ozone fuse Replace unit Contact dealer
See air lock procedure Turn jets on Contact dealer Open slice valve Clean or change filter
Insert jet and turn clockwise until jet snaps into place you will feel the jet seat Contact dealer
Turn jets on Open air control valve Contact dealer Insert jet and turn clockwise until jet snaps into place as it seats
See air lock procedure Add water until water level is 1 inch (25mm) above water line Clean or replace filter Contact dealer During extreme high ambient temperatures the spa may over heat due to internal friction with in the plumbing. Reduce set temperature or remove spa cover to cool. Reduce filtration cycle duration to minimum setting
Check set temperature or heat indicator light on topside console is ON Check filter cycle and reduce to 2 or 4
Check and adjust spa cover if needed Monitor water level after each use Clean or replace filter See common water problems section Based on usage ,adjust filtration cycle duration See common water problem section

SERVICE PORTAL
The FAQ section provides answers to your Swim Spa questions.
Submit a ticket in our system and our global team will effectively solve your issue quickly and efficiently 24/7.

Need assistance? Visit our Service Portal:
support.canadianspacompany.com

Submit a ticket Customer Support on Canadian Spa Company channel

(17)

ST LAWRENCE 20 SWIM SPA
Fill it up!
Preparation and Filling
Fill the spa to its correct operating level. Be sure to open all valves and jets in the plumbing system before filling to allow as much air as possible to escape from the plumbing and the control system during the filling process. After turning the power on at the main power panel, the top-side panel display will go through specific sequences. These sequences are normal and display a variety of information regarding the configuration of the Swim Spa control.
Priming Mode – MO19*
This mode will last for 4-5 minutes or you can manually exit the priming mode after the pump(s) have primed.
RUN PMP5 PURG AIR —-
Regardless of whether the priming mode ends automatically or you manually exit the priming mode, the system will automatically starts normal heating and filtering at the end of the priming mode. During the priming mode, the heater is disabled to allow the priming process to be completed without the possibility of energizing the heater under low-flow or no-flow conditions. Nothing comes on automatically, but the pump can be energized by pushing the “Jets” or “Aux” buttons.
Priming the Pump
As soon as the above display appears on the panel, push the “Jets” button once to start the Pump in low-speed and then again to switch to high-speed. will now be running in high-speed to facilitate priming. If the pump has not primed after 2 minutes, and water is not flowing from the jets in the spa, do not allow the pump to continue to run. Turn off the pump and repeat the process. Note: Turning the power off and back on again will initiate a new pump priming session. Sometimes momentarily turning the pump off and on will help it to prime. Do not do this more than 5 times. If the pump will not prime, shut off the power to the spa and call for service.
Important: A pump should not be allowed to run without priming for more than 2 minutes. Under NO circumstances should a pump be allowed to run without priming beyond the end of the 4-5 minute priming mode. Doing so may cause damage to the pump and cause the system to energize the heater and go into an overheat condition.
Exiting Priming Mode
You can manually exit Priming Mode by pressing the “Warm” or “Cool” button. Note that if you do not manually exit the priming mode as described above, the priming mode will be automatically terminated after 4-5 minutes. Be sure that the pump have been primed by this time. Once the system has exited Priming Mode, the top-side panel will momentarily display the set temperature but the display will not show the water temperature yet, as shown below.
This is because the system requires approximately 1 minute of water flowing through the heater to determine the water temperature and display it.
—C

ST LAWRENCE 20 SWIM SPA
Ready Mode and Rest Mode
In order for the spa to heat, a pump needs to circulate water through the heater. The pump that performs this function is known as the “primary pump.” Primary pump is a 2-Speed Pump 1, Ready Mode (indicated by ) will circulate water periodically, using Pump 1 Low, in order to maintain a constant water temperature, heat as needed, and refresh the temperature display. This is known as “polling.” Rest Mode (indicated by ) will only allow heating during programmed filter cycles. Since polling does not occur, the temperature display may not show a current temperature until the primary pump has been running for a minute or two. In Rest Mode, the spa will only heat to set temperature during programmed filter times.
Water Temperature Setting

(18)

(19)

ST LAWRENCE 20 SWIM SPA
Show and Set Time-of-Day
Be sure to set the Time-of-Day
Setting the time-of-day can be important for determining filtration times and other background features. When in the TIME menu, SET TIME will flash on the display if no time-of-day is set in the memory. 24-hour time display can be set under the PREF menu.

ST LAWRENCE 20 SWIM SPA
Restricting Operation
The control can be restricted to prevent unwanted use or temperature adjustments. Locking the panel prevents the controller from being used, but all automatic functions are still active. Locking the Temperature allows Jets and other features to be used, but the Set Temperature and other programmed settings cannot be adjusted. Temperature Lock allows access to a reduced selection of menu items. These include Set Temperature, FLIP, LOCK, UTIL, INFO and FALT LOG.

Note:
This note refers to systems that do not keep track of Time-of-Day when powered down.
If power is interrupted to such a system, Time-of-Day is not stored. The system will still operate and all other user settings will be stored. If filter cycles are required to run at a particular time of day, resetting the clock will return the filter times to the actual programmed periods. When such a system starts up, it defaults to 12:00 Noon, so another way to get filter times back to normal is to start up the spa at noon on any given day. SET TIME will still flash in the TIME Menu until the time is actually set, but since the spa started at noon, the filter cycles will run as programmed.
Flip (Invert Display)

Unlocking
This Unlock sequence may be used from any screen that may be displayed on a restricted panel. If the panel has both an UP and a Down button, the ONLY button that will work in the Unlock Sequence is the UP button. The temperature will not Unlock if the Unlock sequence is done while the panel is displaying “LOCK”.
Light Timer Programming
Light Timer Option
If LITE TIMR does not appear in the Main Menu, the Light Timer feature is not enabled by the manufacturer. When available, the Light Timer is OFF by default.

(20)

(21)

ST LAWRENCE 20 SWIM SPA
Adjusting Filtration
Main Filtration
Filter cycles are set using a start time and a duration. Start time is indicated by an “A” or “P” in the bottom right corner of the display. Duration has no “A” or “P” indication. Each setting can be adjusted in 15-minute increments. The panel calculates the end time and displays it automatically.
Filter Cycle 2 Optional Filtration
Filter Cycle 2 is OFF by default. It is possible to overlap Filter Cycle 1 and Filter Cycle 2, which will shorten overall filtration by the overlap amount.

Hold Mode ­
MO37
Hold Mode is used to disable the pump during service functions like cleaning or replacing the filter. Hold Mode will last for 1 hour unless the mode is exited manually.
Drain Mode
Some spas have a special feature that allows a pump to be employed when draining the water. When available, this feature is a component of Hold Mode. Drain Mode will time out with Hold Mode.

Purge Cycles
In order to maintain sanitary conditions, the pump will purge water from their respective plumbing by running briefly at the beginning of each filter cycle. If Filter Cycle 1 is set for 24 hours, enabling Filter Cycle 2 will initiate a purge when Filter Cycle 2 is programmed to begin.
(22)

ST LAWRENCE 20 SWIM SPA

Preferences

F / C (Temp Display)
Change the temperature between Fahrenheit and Celsius.
12 / 24 (Time Display) (Not used in Simple Mode)
Change the clock between 12 hr and 24 hr display.
RE-MIN-DERS (Reminders)
Turn the display of reminder messages (like “Clean Filter”) On or Off. Note: Reminders continue to run in the background even when not displayed. So turning the display of Reminders On or Off does not reset any Reminder counts.
CLN-UP (Clean-up)
Clean-up Cycle Duration is not always enabled, so it may not appear. When it is available, set the length of time Pump 1 will run after each use. 0-4 hours are available.
Additional Utilities
Utilities
In addition to INFO, The Utilities Menu contains the following:
A / B (A/B Sensor Temperatures)
When this is set to On, the temperature display will alternate to display temperature from Sensor A and Sensor B in the heater.
FALT LOG (Fault Log)
The Fault Log is a record of the last 24 faults that can be reviewed by a service tech.
(23)

ST LAWRENCE 20 SWIM SPA

General Messages
RUN PMP5 PURG AIR —-
Priming Mode ­ MO19 Each time the spa is powered up, it will enter Priming Mode. The purpose of Priming Mode is to allow the user to run each pump and manually verify that the pump is primed (air is purged) and water is flowing. This typically requires observing the output of each pump separately, and is generally not possible in normal operation. Priming Mode lasts 4 minutes, but you can exit it earlier by pressing any Temp button. The heater is not allowed to run during Priming Mode.

CLN

Appears on a regular schedule, e.g. every 180 days. Vinyl covers should be cleaned and conditioned for

maximum life.

CHEK OZ
normal display.

Alternates with temperature or

Appears on a regular schedule, e.g. every 365 days. Filters should be replaced occasionally to maintain proper spa function and sanitary conditions.

—C
Water Temperature is Unknown After the pump has been running for 1 minute, the temperature will be displayed.
TOO COLD
Too Cold – Freeze Protection A potential freeze condition has been detected, or the Aux Freeze Switch has closed, and the pump is activated, depending on how your system was built. The pump is ON for at least 4 minutes after the potential freeze condition has ended, or when the aux freeze switch opens. In some cases, the pump may turn on and off and the heater may operate during Freeze Protection. This is an operational message, not an error indication.
WATR TOO HOT —-
Water is too Hot (OHS) ­ MO29 One of the water temp sensors has detected spa water temp 110°F (43.3°C) and spa functions are disabled. System will auto reset when the spa water temp is below 108°F (42.2°C). Check for extended pump operation or high ambient temp.
J29 Warning ­ MO44 J29 is typically used as a Heater Disable input. As such, it should not typically be shorted at power-up. This message appears if J29 is shorted at power-up.
Reminder Messages
C H N G W A T R Alternates with temperature or
normal display.

Appears on a regular schedule, e.g. every 365 days. Check your ozone and/or UV generator per your spa manufacture’s instructions.
5 R V C C H E K Alternates with temperature or
normal display.
Appears on a regular schedule, e.g. every 365 days. Have a service technician do a check-up on your spa per your spa manufacturer’s instructions.

Heater-Related Messages
HTR FLOW LOSS —-

Heater Flow is Reduced (HFL) ­ MO16 There may not be enough water flow through the heater to carry the heat away from the heating element. Heater start up will begin again after about 1 min. See “Flow Related Checks” below.

HTR

—-

Heater Flow is Reduced (LF) ­ MO17 There is not enough water flow through the heater to carry the heat away from the heating element and the heater has been disabled. See “Flow Related Checks” below. After the problem has been resolved, you must press any button to reset and begin heater start up.
HTR MAY BE DRY —- WAIT —-
Heater may be Dry (dr)
­ MO28 Possible dry heater, or not enough water in the heater to start it. The spa is shut down for 15 min. Press any button to reset the heater start-up. See “Flow Related Checks” below.

Appears on a regular schedule, e.g. every 90 days. Change the water in the spa on regular basis to maintain proper chemical balance and sanitary conditions.

CLN

C O V R Alternates with temperature or

normal display.

HTR DRY —-
Heater is Dry* ­ MO27 There is not enough water in the heater to start it. The spa is shut down. After the problem has been resolved, you must press any button to reset and restart heater start up. See “Flow Related Checks”.

(24)

ST LAWRENCE 20 SWIM SPA

HTR TOO HOT —-

Heater is too Hot (OHH)* ­ MO30 One of the water temp sensors has detected 118°f (47.8°C) in the heater and the spa is shut down. You must press any button to reset when water is below 108°f (42.2°C). See “Flow Related Checks” below.
PRE5 BTTN TO R5ET —-
A Reset Message may Appear with other Messages. Some errors may require power to be removed and restored.
Flow-Related Checks Check for low water level, suction flow restrictions, closed valves, trapped air, too many closed jets and pump prime. On some systems even when spa is shut down, some equipment may occasionally turn on to continue monitoring temperature or if freeze protection is needed.
Sensor-Related Messages
5N5R BAL- ANCE
Sensor Balance is Poor ­ MO15 The temperature sensors MAY be out of sync by or 3°F. Call for Service.

°F or °C is replaced by °T The Control System is in Test Mode. Call for Service. This message can be reset from the topside panel with any button press.
MEM
Memory Failure – Checksum Error
­ MO22 At Power-Up, the system has failed the Program Checksum Test. This indicates a problem with the firmware (operation program) and requires a service call.
Memory Warning – Persistent Memory Reset ­ MO21 Appears after any system setup change. Contact your dealer or service organization if this message appears on more than one power-up, or if it appears after the system has been running normally for a period of time. This message can be reset from the topside panel with any button press.
CLOK FAIL
Memory Failure – Clock Error* ­ MO20 Contact your dealer or service organization.

5N5R 5YNC —- CALL FOR 5RVC —-
Sensor Balance is Poor* ­ MO26 The temperature sensors ARE out of sync. The Sensor Balance is Poor fault has been established for at least 1 hour. Call for Service.

CNFG FAIL

CALL FOR 5RVC

Configuration Error ­ Spa will not Start Up Contact your dealer or service organization.

5TUK PUMP

5N5R A B

—- CALL

5RVC —-

Sensor Failure ­ Sensor A: MO31, Sensor B: MO32 A temperature sensor or sensor circuit has failed. Call for Service.

Miscellaneous Messages

NO COMM
No Communications The control panel is not receiving communication from the System. Call for Service.
BETA VER- 5ION —-
Pre-Production Software The Control System is operating with test software. Call for Service.

A Pump Appears to be Stuck ON ­ MO34 Water may be overheated. POWER DOWN THE SPA. DO NOT ENTER THE WATER. Contact your dealer or service organization.

HOT

CALL

5RVC

A Pump Appears to have been Stuck ON when spa was last powered – MO35 POWER DOWN THE SPA. DO NOT ENTER THE WATER. Contact your dealer or service organization.

WATR LEVL
The water level is too low Some systems have a water level detect, and this message appears if it detects that the water level is too low. * This message can be reset from the topside panel with any button press.

(25)

ST LAWRENCE 20 SWIM SPA

Reminder Messages

General maintenance helps. The display of Reminder Messages can be suppressed by using the PREF Menu.

Reminder Messages can be chosen individually by the Manufacturer. They may be disabled entirely, or there may be a limited number of reminders on a specific model. The frequency of each reminder (e.g. 7 days) can be specified by the Manufacturer.

Press a Temperature button to reset a displayed reminder message.

CHEK PH
normal display.

Alternates with temperature or

Appears on a regular schedule, e.g. every 7 days. Check pH with a test kit and adjust pH with the appropriate chemicals.
C H E K C H E M Alternates with temperature or
normal display.

Appears on a regular schedule, e.g. every 7 days. Check sanitizer level and other water chemistry with a test kit

and adjust with the appropriate chemicals.

CLN
normal display.

Alternates with temperature or

Appears on a regular schedule, e.g. every 30 days. Clean the filter media as instructed by the manufacturer.

Appears on a regular schedule, e.g. every 30 days. Residual Current Device (RCD) is an important safety device and must be tested on a regular basis to verify its reliability.

Every user should be trained to safely test the RCD associated with the Swim Spa installation. An RCD will have a TEST and RESET button on it that allows a user to verify proper function.

Warning: If freezing conditions exist, a RCD should be reset immediately or spa damage could result. The end user should always trained to test and reset the RCD on a regular basis.

Swim Spa Parts

Glass fuse 10 Amp. KK-10376

SC30 Buss fuse 30 Amp. KK-10382

f3 fuse topside 1/8. KK-11107

2.25″ Small Point 2.25″ Directional 2.25″ Massage Jet 3.5″ Directional Jet 3.5″ Massage Jet 5″ Directional Jet

Jet KK-10039

Jet KK-10040

KK-10041

KK-10050

KK-10051

KK-10052

5″ Massage Jet KK-10053

10″ Waterfall KK-10155

90 x 90″/228 x 228 Brown Cover (2 Part) KC-10259

Air Control KK-10184

Waterfall valve KK-10141

Water Diverter KK-10191

Aromatherapy Cap KK-10209

LED Light KK-10213

Pop-Up Speaker KK-10043

Bread Pillow KK-010145

Big Red LX 5 hp 2 speed Pump
KK-10319

Big Red LX 5 hp 1 speed Pump
KK-10319

Balboa CN613 BP600/ 2100 (M7)

Control 3 Kw heater

Heater 3kW

KK-10328

KK-10285

(26)

Audio Control (6 Button) KK-11320

UV + Ozone KK-KK-11328

UV 15W lamp kit with sleeve KK-11202

ST LAWRENCE 20 SWIM SPA
BP2100
(27)

ST LAWRENCE 20 SWIM SPA

LIMITED WARRANTY

Canadian Spa Co. Manufacturing extends the following warranties to the original purchasers of its portable spas:
Structural Warranty: Canadian Spa Co. warrants structure of the spa shell against water loss due to structural failure for the period of 10 years from the date of purchase by the original owner. If in Canadian Spa Co. opinion, structure proves to be defective Canadian Spa Co. will repair or, at its option, replace the defective structure without charge to the customer
Surface Warranty: Canadian Spa Co. warrants the acrylic finish against defects in material and workmanship and specifically against blistering, cracking or delamination for the period of two (2) years from the original purchase date to the original purchaser. If, in Canadian Spa Co. opinion, the surface proves to be defective during this period, Canadian Spa Co. will repair or, at its option, replace the defective spa shell without charge to the customer.
Plumbing Warranty: Canadian Spa Co. warrants the plumbing of the spa will remain free from leaks for the period of two (2) years from the date of purchase to the original purchaser.
Equipment Warranty: Canadian Spa Co. warrants the equipment pack (pump, heater, and control system) against malfunction and defects in the materials and workmanship for two (2) years from the date of purchase to the original purchaser.
Skirting Warranty: Canadian Spa Co. warrants the wood skirting surrounding the spa to be free from defects in materials and workmanship at the time of purchase. Because wood is a natural product and subject to weathering, any fading, crazing, cracking or warping of the wood finish is not covered.
Extent of Warranty: This Limited Warranty applies to portable spas manufactured after March 31st 2022 and sold by authorised Canadian Spa Co. dealers to residential retail customers. This Limited Warranty is given only to the first retail purchaser and terminates upon transfer of ownership. No warranty is provided on UV lights, light bulbs, light lens covers, filters or any dealer installed accessories. Cost of installation, removal and/or shipping of the spa is not covered by this Limited Warranty. In the event Canadian Spa Co. deems necessary the removal of the spa to a place of repair or that the spa must be replaced, any and all costs of the spa removal and replacement; landscaping, decking, fencing and/or structure removal, alteration and/or replacement; or other costs of providing access to the spa will be for the purchaser. This Warranty applies only to spas in single family, residential installations. This Limited Warranty becomes void if the spa is placed in commercial application.
Guarantee of the insulating cover: Canadian Spa Co. guarantees that the cover the purchase is free from defects in materials and workmanship. Where the cover is exposed to strong external influences such as extreme weather conditions, regular maintenance or protection is essential . Canadian Spa Co. warrants the cover for the period of two (2) years. Defects caused by misuse or insufficient care are not covered by the warranty.

TERMS, CONDITIONS AND LIMITATIONS Any defect or damage caused by installation, alteration or repair by anyone who is not an employee of Canadian Spa Co. or authorised service technician is not covered by the Warranty. This Warranty becomes void if the spa has been subjected to misuse, abuse, alteration or attempted alteration, repairs or attempted repairs by anyone other than an authorised Canadian Spa Co. service technician, improper installation, improper water chemistry, improper maintenance, acts of god, or damage caused beyond the control of Canadian Spa Co. Misuse and abuse shall include any operation of the spas other than as directed in the Canadian Spa Co. Manual. Examples of misuse and abuse include, without limitation:
· Damage of the spa surface caused by leaving the spa uncovered while the spa is empty of water or due to covering the spa with plastic film of any kind.
· Damage to the spa surface caused by contact with cleaners or solvents. · Damage caused by the operation of the spas at water temperatures
outside of the range of 2 ­ 40 degrees Celsius. · Damage caused by unapproved sanitizer such as calcium
hypochlorite, tri-chlor type chlorine or any sanitising chemical that may remain undissolved on the spa surface. · Damage caused by failure to provide even sufficient support for the spa.
Warranty Performance: In the event of a defect covered under the terms of this Limited Warranty, notify your authorised Canadian Spa Co dealer. A Canadian Spa Co. authorised service technician will repair the spa subject to the Terms and Conditions of this Limited Warranty. Use all reasonable means to protect the spa from further damage. Reasonable travel charges may be assessed by Canadian Spa Co. or its authorised service technician if the spa is located outside the nearest authorised service technician’s service area. This warranty covers parts ONLY and does not include travel or on-site service charges unless a Service Contract has been purchased from Canadian Spa Co. Ltd.
Disclaimers: Canadian Spa Co. or any of its authorised service technicians shall not be held liable for injury, inconvenience, loss of use, chemical or water damage, transportation costs, continent liabilities or any other incidental or consequential costs, expenses or damage as result of any deficiency or alleged deficiency of the spa. In no event shall Canadian Spa Co. be liable, for any reason or cause, in excess of the amount paid for the product. No other warranties, expressed or implied, are valid. No agent, dealer, distributor, Service Company or other party is authorised to change, modify or extend the terms of this Limited Warranty in any manner whatsoever.
For Service Support please contact us anytime:
support.canadianspacompany.com

European Head Office: Canadian Spa Company Canada House, Salbrook Road, Salfords, Redhill, Surrey, RH1 5GL, U.K T: +44 1293 82409 www.canadianspacompany.co.uk

France Office: Alliance SAS 2 Impasse Paul Séjourné 66350 Toulouges France T. +33(0) 411 819 773 E: [email protected]

German Office: Canadian Spa Company GmBh Hohenstaufenring 43 ­ 45 50674 Köln, Germany TEL: + 49 22038064038 www.canadianspacompany.de

KM-10235 02/12/22

Canadian Spa Company meets ISO 9001 Standards. When you purchase a Swim Spa from Canadian Spa Company the ISO 9001 Certification assures world class excellence in manufacturing and customer service.
canadianspacompany.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Canadian Spa Company User Manuals

Related Manuals