GE HTX26GASWWW Hotpoint 6.2 Cu. Ft. Capacity Gas Dryer User Manual
- May 15, 2024
- GE
Table of Contents
GE HTX26GASWWW Hotpoint 6.2 Cu. Ft. Capacity Gas Dryer
DRYER DIMENSIONS (IN INCHES)
EXHAUST OPTIONS: 3-way via rear, left and bottom. Dryer is shipped exhausted to the rear. Alternate exhausting knockouts are supplied.
CIRCUIT REQUIREMENTS: An individual properly-grounded branch circuit, with a three-prong grounding-type receptacle, protected by a 15- or 20-amp circuit breaker or a time-delay fuse, is required.
GAS DRYER ELECTRIC RATING : 120V, 60Hz, 6 Amp
GAS (BTU/HR) : 22,000. Factory-equipped for natural gas. Tested for LP gas. LP gas supply requires an optional conversion kit. Check installation instructions for correct kit and have a qualified gas technician install a conversion kit. See dryer ducting information for proper installation.
INSTALLATION INFORMATION: For complete information, see installation
instructions packed with product for current dimensional data.
SPECIAL INSTALLATION REQUIREMENTS
ALCOVE OR CLOSET INSTALLATION:
- If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back.
- The dryer MUST be exhausted to the outside.
- Minimum clearances between dryer cabinet and adjacent walls or other surfaces are: 0″ either side, 1″ front, top and rear
- Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed.
- No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
BATHROOM OR BEDROOM INSTALLATION:
- The dryer MUST be exhausted to the outdoors.
- The installation must conform with the local codes, or in the absence of local codes, with the National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.
MINIMUM CLEARANCES OTHER THAN ALCOVE OR CLOSET INSTALLATION:
Minimum clearances to combustible surfaces 0″ both sides, 1″ rear.
POWER CORDS: GE Appliances strongly recommends the use of factory
specified parts. Select the power cord to fit your installation requirements.*
NOTE: If the dryer circuit is on a circuit protected by a GFCI breaker,
then 3-wire installation is not permitted.
Hose wiring and dryer must be configured for 4-wire.
Part Number | Type | Length | Amperage |
---|---|---|---|
WX9X2 | 3-Prong | 4 Feet | 30 |
WX9X3 | 3-Prong | 5 Feet | 30 |
WX9X4 | 3-Prong | 6 Feet | 30 |
WX9X18 | 4-Prong | 4 Feet | 30 |
WX9X19 | 4-Prong | 5 Feet | 30 |
WX9X20 | 4-Prong | 6 Feet | 30 |
For complete information, see installation instructions packed with your dryer.
DUCTING MATERIALS:
For best performance, this dryer should be vented with 4″ diameter all-rigid metal exhaust duct. If rigid metal duct cannot be used, then UL-listed flexible metal (semi-rigid) ducting can be used (Kit WX08X10077). In special installations, it may be necessary to connect the dryer to the house vent using a flexible metal (foil-type) duct. A UL-listed flexible metal (foil- type) duct may be used ONLY in installations where rigid metal or flexible metal (semi-rigid) ducting cannot be used AND where a 4″ diameter can be maintained throughout the entire length of the transition duct. Please see installation instruction packed with your dryer for complete instructions when using flexible metal (foil-type) ducting.
EXHAUST LENGTH CALCULATION:
-
Determine the number of 90° turns needed for your installation.
If you exhaust to the side or bottom of dryer, add one turn. -
The maximum length of 4″ rigid (aluminum or galvanized) duct which can be tolerated is shown in the table. A turn of 45° or less may be ignored.
Two 45° turns within the duct length should be treated as a 90° elbow. A turn over 45° should be treated as a 90° elbow.
Dryers MUST be exhausted to the outside.
CAUTION: For personal safety, do not terminate exhaust into a chimney,
under any enclosed house floor (crawl space), or into an attic, since the
accumulated lint could create a fire hazard or moisture could cause damage.
Never terminate the exhaust into a common duct or plenum with a kitchen
exhaust, since the combination of lint and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back
drafts, bird nesting, etc. The wall cap must also be located at least 12″
above the ground or any other obstruction with the opening pointed down.
ACCESSORIES*
GE Part Number | Description |
---|---|
WX09X10002 | 4′ 30 Amp. 3-Wire Dryer Cord |
WX09X10003 | 5′ 30 Amp, 3- Wire Dryer Cord |
WX09X10004 | 6′ 30 Amp 3-Wire Dryer Cord |
WX09X10018 | 4′ 30 Amp. 4-Wire Dryer Cord |
WX09X10019 | 5′ 30 Amp. 4-Wire Dryer Cord |
WX09X10020 | 6′ 30 Amp. 4-Wire Dryer Cord |
WX08X10086 | 8′ Flexible Dryer Duct l:lith 2 screw clamps |
PM08X10085 | 8′ Flexible Dryer Duct with 2 screw clamps, retail kit |
WX8X73 | 8′ Flexible Dryer Duct with 2 tension clamps |
PM8X73 | 8′ Flexib le Dryer Duct with 2 tension clamps, ret ail kit |
W X0 8 X10130 -100 PK | 4″ Dryer Tension Clamp |
WX08X10131-50PK | 4″ Dryer Screw Clamp |
WX8X74 | 50′ Dryer Duct |
PM8X85 | Universal Outdoor Dryer Exhaust |
PM15X104 | Gas Dryer Connector Kit – 4′ x 5/8″ gas connector |
PM15X114 | Gas Dryer Connector Kit, coated with auto shut off; 4′ x 5/ 8″ gas |
connector
WE01X25160| Drying Rack
WE49X22606| Rear Exhaust Opening Cover
14-D346-33| Gas Dryer Hold-Down Kit (Mobile Homes)
WE25X217| Propane gas conversion kit.
*Accessories sold separately.
Dryer exhausting information – use metal duct only vertical and horizontal ducting.
For every extra 90° elbow, reduce the allowable vent system length by 10 ft.
Two 45° elbows will be treated like one 90° elbow.
For the side exhaust installations, add one 90° elbow to the chart.
When calculating the total vent system length, you must add all the straight
portions and elbows of the system (including the transition duct).
Laundry Center length includes factory-installed elbow that does not impact
vent length.
Domestic dryer models | Best performance |
---|
Maximum length of 4″ dia rigid metal duct
Exhaust hood type
Number of 90° turns| A 4″ opening| B 2-1/2″ opening
Long Vent 6.0 – 8.0 cu. ft. capacity electric & gas dryers (HTX26)| 0
1
2
3
4
5| 120 ft.
100 ft.
85 ft.
70 ft.
60 ft.
55 ft.
| 90 ft.
75 ft.
65 ft.
55 ft.
45 ft.
35 ft.
FEATURES AND BENEFITS
AutoDry – AutoDry monitors the internal air temperature to determine the ideal drying time, protecting your garments from over drying.
Powerful Venting & Flexible Installation – Powerful airflow offers long- lasting performance from lint build-up and offers venting solutions up to 120 feet for greater installation flexibility .
Large Diffuser for Even Drying – A large internal heat diffuser allows for warm air to evenly spread throughout your clothes during the cycle, making this the ideal dryer for large loads and bulky items.
Durable Aluminized Drum – This durable, long-lasting design resists corrosion and optimizes drying performance.
Reversible Dryer Door – Door can swing from either direction, making it easier to access the last sock from the back of the drum.
Shallow Depth Design – Reaching into your dryer is easier than ever thanks to the shallow depth design, which also fits into more spaces without sacrificing capacity.
Up-Front Lint Filter – Simplify the task of lint removal with our convenient
upfront lint filter, enhancing airflow within the appliance and for your
garments.
CUSTOMER SUPPORT
COMPATIBLE WASHER:
HTW265ASWWW – Hotpoint® 4.0 cu. ft. Capacity Washer
with Stainless Steel Basket, Cold Plus
and Water Level Control
HTX26GASWWW: White
Specification Revised 2/24