GENELEC 8340A Smart Active Monitor Speaker System
Product Information
The 8340A is a Genelec Smart Active Monitor (SAM) system designed for professional monitoring tasks requiring high precision and reliability. It features the Minimum Diffraction EnclosureTM (MDETM) and advanced Directivity Control WaveguideTM (DCWTM) technologies, which provide excellent frequency balance even in difficult acoustic environments. The system can be set up and used with the Genelec Loudspeaker Manager GLMTM and the proprietary Genelec monitor control network and software, offering much more versatile acoustic settings and features. The 8340A SAM monitor supports both standard analog line level audio and AES/EBU formatted digital audio signals.
Main Features
- Minimum Diffraction EnclosureTM (MDETM) technology
- Advanced Directivity Control WaveguideTM (DCWTM) technology
- Intelligent Signal Sensing (ISSTM)
- Energy-saving mode
- Support for both analog and digital audio signals
- Genelec Loudspeaker Manager GLMTM support
Product Usage
To use the 8340A SAM monitor system:
- Connect the MAINS INPUT to the mains supply using the supplied mains cable. The product supports any mains voltage globally (100-240 VAC, 50-60 Hz) so it can be plugged in anywhere.
- If you have the Genelec Loudspeaker Manager GLMTM, use it to set up and configure the system, using the GLM network cable and the GLM Network Microphone. Refer to the GLMTM System Operating Manual for instructions on how to use it.
- If you don’t have the GLMTM, use the settings on the monitor for system setup. These settings are limited but provide the basic acoustical calibrations and input selection. To use this method, set the STORED switch OFF.
- Configure the DIP switches for stand-alone use based on your requirements.
- Connect the audio source to the system using either the DIGITAL IN AES/EBU, DIGITAL THRU AES/EBU or ANALOG IN connectors.
- Use the sensitivity control to adjust the volume level (in dBu) for 100 dB SPL (1 m).
- Use the LED DISABLE switch to turn off the front LED if required.
- Turn on the power and the system is ready for use.
Note: The Intelligent Signal Sensing (ISSTM) can be turned on to put the monitor automatically into a deep sleep state where the product consumes less than one Watt of power. Upon sensing an input signal the monitor automatically wakes up to full operation. The wait until entering the ISS power save can be configured using the GLM software. When the ISS is active you can have your monitoring system ready for action at all times.
Introduction
Congratulations and a thank you for the purchase of this Genelec Smart Active
Monitor (SAM) system. This manual addresses the stand-alone setup and use of
the 8340A SAM monitor. These monitors can also be set up and used with the
Genelec Loudspeaker Manager GLM™ and the proprietary Genelec monitor control
network and software, offering much more versatile acoustic settings and
features. Use with the GLM™ is described in the GLM™ System Operating Manual.
All Genelec SAM systems are designed to integrate easily into all professional
environments, supporting both standard analog line level audio and AES/EBU
formatted digital audio signals.
The 8340A is suitable for professional monitoring tasks demanding high
precision and reliability of monitoring. The Minimum Diffraction Enclosure™
(MDE™) and advanced Directivity Control Waveguide™ (DCW™) technologies provide
excellent frequency balance even in difficult acoustic environments.
Each monitor is supplied with a mains cable, one 5 m GLM network cable and an
operating manual.
Energy saving Intelligent Signal Sensing (ISS™) can be turned on to put the
monitor automatically into a deep sleep state where the product consumes less
than one Watt of power. Upon sensing an input signal the monitor automatically
wakes up to full operation. The wait until entering the ISS power save can be
configured using the GLM software. When the ISS is active you can have your
monitoring system ready for action at all times.
System setup using GLM™ Control Network
Although the 8340A can be used without the GLM™ software and control network,
they only reach their full potential when set up and calibrated using the GLM™
software. Genelec Loudspeaker Manager GLM™ and the proprietary Genelec monitor
control network and software offer automated acoustic equalization and
alignment for any reproduction system from simple stereo to very complex 3D
immersive audio setups including also one or more subwoofers. GLM setup is
fast and accurate. The settings can be controlled with a computer or be
permanently stored in the monitors to make the setup available at all times
even when a computer is not in use. Genelec recommends setting up SAM
monitoring systems using GLM. You can find a detailed description of the setup
and the use of GLM™ in the GLM™ System Operating Manual.
The setup is fast and consists of the following steps:
Figure 1. GLM control network cabling
- Connect a CAT5 (RJ45) cable between each monitor (and subwoofer) and finally to the control network input of the GLM Adapter device (see Figure 1).
- Connect the GLM Adapter device to computer USB connector.
- Using a microphone stand, place the Genelec measurement microphone at the listening location with the microphone pointing upwards and the microphone top at the height of the engineer’s ear. The microphone is a part of the GLM User Kit.
- Connect the microphone cable to the microphone input in the GLM Adapter device.
- Download the GLM software at the Genelec web site (www.genelec.com).
- Install the GLM software and follow the instructions in the software to measure and set up your monitors.
- If you plan to not use a computer for controlling the monitors, use the GLM software to write the setting into the monitors (use menu item “Store | Store the Current Group Settings…”).
While the GLM network is disconnected the settings stored using the Genelec Loudspeaker Manager software can be selected in use by setting the STORED switch ON.
Setup without using the GLM
When GLM is not available, you can use the settings on the monitor for system
setup. These settings are limited but provide the basic acoustical
calibrations and input selection. To use this method, set the STORED switch
OFF.
Connect the MAINS INPUT to the mains supply. These products support any mains
voltage globally (100-240 VAC, 50-60 Hz) so they can be plugged in anywhere.
If the mains power is provided with a generator, inverter or certain lower-
quality UPS devices, we recommend filtering of the mains power voltage
harmonics and taking care that the voltage supply is stable.
Figure 2. Connectors and controls on the back panel of a 8340A.
The ANALOG IN connector is used for analog audio signals. The maximum input
level is +25 dBu. These monitors produce 100 dB SPL sound level at 1 meter in
free space for an analogue input signal of -6 dBu.
The DIGITAL IN AES/EBU female XLR connector is for AES/EBU formatted digital
audio input signals. This input is selected automatically when a valid digital
audio signal is present. Analog input is selected when the AES/EBU signal
input is disconnected. The AES/EBU input supports two channels in a single
cable). When the digital source device controls the digital output level, it
may be advantageous to lower the level on the monitor’s controls, which will
enable the use of a higher digital signal level with more digital resolution.
With digital inputs the audio is referenced to 0 dBFS (dB relative to the
digital full scale, the largest level that can be represented in the AES/EBU
signal). These monitors produce 100 dB SPL sound level at 1 meter in free
space for a digital input signal of –30 dBFS. The DIGITAL OUT male XLR carries
an unaltered copy of the digital signal fed into the digital in connector.
This enables daisy-chaining up to four monitors.
The CONTROL NETWORK RJ-45 connectors are used with Genelec Loudspeaker
Manager™ (GLM™) network. These connectors are not Ethernet LAN compatible. Do
not connect to Ethernet LAN.
Stand-Alone Control Functions
Bass Roll-Off Control
Bass Roll-Off control attenuates the monitor’s output near the cut-off
frequency. Attenuation levels of -2 dB, -4 dB or -6 dB (both switches ON) can
be selected.
Monitor
Mounting Position
| Treble Tilt| Bass Tilt| Bass Roll-Off| Desktop
---|---|---|---|---
Flat anechoic response| None| None| None| None
Free standing in a damped room| None| -2 dB| None| None
Free standing in
a reverberant room
| None| -4 dB| None| None
Near field on
a reflective surface
| None| -2 dB| None| -4 dB
In a corner| None| -4 dB| -4 dB| None
Table 1. Suggested Tone Control settings for some typical monitor placement positions.
Desktop 160 Hz
The desktop low frequency control (switch 5) attenuates the bass frequencies
around 160 Hz by 4 dB. This feature is de-signed to compensate for the boost
often occurring at this frequency range when the monitor is placed upon a
meter bridge, table or similar reflective surface.
Bass Tilt Control
The Bass Tilt control switches (swiches 3 and 4) offer three at-tenuation
levels for the bass response below 800 Hz, usually necessary when the monitors
are placed near room boundaries. The attenuation levels are -2 dB, -4 dB and
-6 dB.
Treble Tilt Control
Treble Tilt control allows adjusting the treble response above 5
Figure 3. The location of the acoustic axis is on the center-line of the monitor at the given height “h”.
Figure 4. Symmetrical layout and keeping the acoustic axis clear from obstructions minimizes reflection surfaces and maintains accurate localisation because reflections are symmetrical.
Figure 5. Recommended distances from a single wall to the front baffle of free-standing monitors. Correct (green) and not recommended (red).
Figure 6. Recommended monitor positioning for 5.1 multi-channel audio
reproduction
kHz by +2 dB, -2 dB or -4 dB, which can be used for correcting an excessively
bright or dull sounding system or to compensate for high frequency level loss
if the monitor is placed behind a screen.
LED Disable
This switch shuts off the front panel LED light.
ISS
This switch activates or deactivates the ISS automatic power saving function.
The default time for ISS activation is 60 minutes, but can be adjusted in GLM.
Digital
The Digital switch selects the digital audio channels on the AES/EBU. Turning
both switches on reproduces the sum of the A and B channels. A 6 dB of
attenuation is applied to avoid
Colour | Indication |
---|---|
Solid greed | Normal state, normal operation |
Blinking green | GLM is adjusting the monitor |
Green blink every 10 sec. | Monitor is an ISS power saving sleep state |
Red blink | Power amplifier overload protection is active (audio is |
modified because of protection)
Solid red| Monitor is muted
Yellow| Monitor is not in the active (playing) group
Yellow blinking| Overheat protection is active (audio is modified
because of protection)
Table 2. Monitor front panel light indications summary
overloading the monitor. If the AES/EBU cable is operated in dual-wire mode,
the monitor detects this automatically and the channel selection switches have
no effect.
Level
The Level switches scale down the monitor output level in 10 dB steps. The
effects of these switches add up and combine with the effect of the rotary
level adjustment control. The combined total setting range is 42 dB.
Stored
Stored switch selects the use of the controls on the monitor’s back panel or
the settings stored inside the monitor memory using the GLM system calibration
software. Setting the Stored switch to OFF position selects the settings
defined by the monitor’s own controls. Setting the Stored switch to ON
position selects the use of internally stored GLM settings. Using the Stored
option overrides all adjustments done with the monitor’s own controls.
Operating Environment
These monitors are designed for indoor use only. The permissible ambient temperature is 15-35 degrees Celsius (50-95°F) and relative humidity 20% to 80% (non-condensing). When the product has been stored or transported in cool environment and is taken into a warm room, wait 0.5-1 hours before opening any packing to prevent condensation of humidity before connecting to mains power. Sufficient cooling must be ensured. The minimum clearance is 50 mm (2 in) behind, above and on both sides of the monitor. The space must be ventilated sufficiently to dissipate the heat.
Mounting and Placing Monitors
Mounting Options
The vibration-insulating Isolation Positioner/Decoupler™ (Iso-Pod™) table
stand allows tilting of the monitor for correct alignment of the acoustic
axis. The stand can be attached to three points on the enclosure, allowing
vertical and two horizontal positions. Aim the monitor so that its acoustic
axis point towards the listening position (see Figure 3). Vertical orientation
is preferable, as this eliminates acoustical cancellation problems around the
crossover frequency. Place the monitors symmetrically at equal distances from
the listening position. If possible, place the listening position on the left-
right centerline of the room (see Figure 4). When a monitor far away (1 to 2.2
m, 3-7 ft) from the acoustically hard wall behind the monitor, an acoustic
reflection from the wall may cause cancellation of low frequencies and reduce
bass output.
Acoustic reflections from objects like desks, cabinets, computer monitors etc.
can cause unwanted colouration and blurring of the sound image. Minimize these
by placing the monitors away from acoustically reflective surfaces. Putting
the monitors on stands behind and above a mixing console usually improves the
response over placing monitors on a meter bridge. Symmetrical positioning of
the sound-reflecting objects maintains a balanced soundstage (see Figure 4).
A wide variety of ceiling and wall mounts are available through your Genelec
dealer. The 8340A can be fitted with König & Meyer monitor mounts using two M6
x 10 mm threaded holes on the enclosure back. There is an M10 x 10 mm threaded
hole in the base of the monitor. Do not use this thread for mounting the
monitor on a microphone stand. Monitor stands typically have an incompatible
3/8” UNC thread. A wide selection of accessories is available for Genelec
monitors. Consult the Genelec Accessories Catalogue at
www.genelec.com or your local distributor/dealer for
information.
Front Panel Light
Normally, the light on the front panel is green, indicating normal operational mode. Red and yellow colours are used to indicate special situations. See Table 2 above.
Use with Subwoofers
Genelec recommends using the 7300 series subwoofers. For more detailed system
configuration and matching products, please consult the online Genelec Product
Selection Tool at www.genelec.com.
Maintenance
There are no user-serviceable parts inside the monitor. Maintenance or repair
must only be done by a Genelec-certified service.
Figure 7. The curves above show the effect of the “Bass Tilt”, “Treble Tilt”, “Desktop Low Frequency” and “Bass Roll-Off” controls on the free field response of the 8340A.
Safety Considerations
Although the 8340A has been designed in accordance with international safety standards, to ensure safe operation and to maintain the monitor under safe operating conditions, the following warnings and precautions must be observed:
- Servicing and adjustment must only be performed by a certified Genelec service. The monitor enclosure must not be opened.
- Do not use this product with an unearthed mains cable or a mains connection without the protective earth contact as this may lead to personal injury.
- To prevent fire or electric shock, do not expose the unit to water or moisture.
- Do not place any objects filled with liquid, such as vases on the monitor or near it.
- Note that the amplifier is not completely disconnected from the AC mains service unless the mains power cord is removed from the amplifier or the mains outlet.
- Free flow of air behind the monitor is necessary to maintain sufficient cooling.
- Do not obstruct airflow around the monitors.
WARNING!
These monitors are capable of producing sound pressure levels in excess of 85
dB, which may cause permanent hearing damage.
Guarantee
The Genelec 8340A is guaranteed for two years against
Figure 8. The upper curve group shows the horizontal directivity characteristics of the 8340A measured at 1 m. The lower curve shows the system’s power response.
Figure 9. The curve above shows the delay variation of the 8340A as a function of frequency.
manufacturing faults or defects altering performance. Refer to the reseller for full sales and guarantee terms.
FCC
Compliance to FCC Rules
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help
- Modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment under FCC rules.
Figure 10. The curves above show the horizontal directivity characteristics of the 8340A.
Figure 11. The curves above show the vertical directivity characteristics of the 8340A.
SYSTEM SPECIFICATIONS
| 8340A
Lower cut-off frequency, –6 dB| < 38 Hz
Upper cut-off frequency, –6 dB| > 22 kHz
Accuracy of frequency response, ± 1.5 dB| 45 Hz – 20 kHz
Maximum short term sine wave acoustic output on axis in half space, averaged
from 100 Hz to 3 kHz at 1 m| ≥ 110 dB SPL
Maximum long term RMS acoustic output in the same conditions with IEC weighted
noise (limited by driver protection circuit) at 1 m| 100 dB SPL
Maximum peak acoustic output per pair in a listening room with music material
at 1 m| ≥ 118 dB
Self generated noise level in free space at 1 m on axis (A-weighted)| ≤ 5 dB
Harmonic distortion at 90 dB SPL at 1 m on axis Freq: 50…100 Hz
100 Hz
|
< 2 %
< 0.5 %
Drivers|
Bass| 165 mm (61/2 in) cone
Treble| 19 mm (3/4 in) metal dome
All drivers are magnetically shielded|
Weight| 8.4 kg (18.5 lb)
Dimensions|
Height| 350 mm (1313/16 in)
Width| 237 mm (93/8 in)
Depth| 223 mm (813/16 in)
Height with Iso-Pod™| 365 mm (143/8 in)
AMPLIFIER SECTION
8340A |
---|
Bass amplifier short term output power Treble amplifier short term output power
(Long term output power is limited by driver protection circuitry)
| 150 W
150 W
Amplifier system THD at nominal output| <0.01%
System Signal to Noise ratio, A-weighted Bass
Treble
| ****
109 dB
110 dB
Mains voltage| 100-240 VAC 50/60 Hz
Power consumption|
ISS active| < 1 W
Idle| 12 W
Full output (short term)| 180 W
SIGNAL PROCESSING SECTION
8340A |
---|
Analog signal input connector XLR female, balanced 10 kOhm
Maximum analog input signal
Analog input sensitivity (100 dB SPL at 1 m) Analog input gain selection, rotary control
| pin 1 gnd
pin 2 non-inverting,
pin 3 inverting
+25.0 dBu
-6 dBu
Adjustable from +6 to -6 dBu
Digital signal input connector XLR female 110 Ohm Digital signal output / Thru
connector XLR male 110 Ohm| AES/EBU Single Wire AES/EBU Single Wire
Digital audio input Word length Sample rate
Digital input sensitivity (100 dB SPL at 1 m ) Digital input gain sensitivity, rotary control
| ****
16 – 24 bits
32 – 192 kHz
-30 dBFS
Adjustable from +6 to -6 dBu
Control network Type Connection| ****
Proprietary GLM™ network 2 RJ45, CAT5 cables
Crossover frequency| 2.6 kHz
GLMTM software frequency response adjustment* Parametric notch filters
Shelving filters
| ****
16
2 LF and 2 HF
System room response calibration| Genelec GLM AutoCal™ AutoCalTM, GLMTM manual, Stand-alone*
- The notch and shelving filters adjustments, AutoCalTM and GLMTM manual system calibration features are part of the Genelec Loudspeaker Manager (GLMTM) software
Genelec Document D0133R003 Copyright Genelec Oy 9.2017. All data subject to change without prior notice.
International enquiries: Genelec, Olvitie 5
FIN-74100, Iisalmi, Finland Phone +358 17 83881
Fax +358 17 812 267 Email genelec@genelec.com
In the U.S. please contact: Genelec, Inc., 7 Tech Circle Natick, MA
01760,
USA Phone +1 508 652 0900
Fax +1 508 652 0909
Email genelec.usa@genelec.com
In Sweden
Genelec Sverige
Tureholmsvägen 12
125 35 Älvsjö
Sweden
Phone +46 8 449 5220
Email sweden@genelec.com
In China please contact: Beijing Genelec Audio Co.Ltd B33 – 101
Universal Business Park
No. 10 Jiuxianqiao Road Chaoyang District
100015 Beijing, China
Phone +86 400 700 1978
Email genelec.china@genelec.com
In Japan
Genelec Japan Inc.
2-22-21 Akasaka,Minato-ku
07-0052,Tokyo
Phone +81-3-6441-0591
genelec.japan@genelec.com
Email genelec.japan@genelec.com
References
- World Leader in Studio Monitors - Genelec.com
- GENELEC真力 · 有源监听音箱领跑者 | Genelec(真力)——始于 1978 年,来自芬兰的有源音箱制造商。
- World Leader in Studio Monitors - Genelec.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>