Product Information
The product is a versatile thermostat that can be used for various heating and cooling systems. It can be used for conventional heating and cooling systems with up to 2 stages each, heat pumps with auxiliary heat, boilers or radiant systems with air handlers, and power extender kit thermostat wiring.
Specifications
- Compatible Systems: Conventional heating and cooling, heat pump (air or geothermal) with auxiliary heat, boiler or radiant system with air handler and conventional cooling or heating
- Compatible Stages: Up to 2 stages for heating and cooling
- Compatible Wiring : RC, RH, G, S, O/B, Y, Y2, NTC+, NTCC, AUX/W, E/W2
Product Usage Instructions
Conventional Heating and Cooling
For conventional heating and cooling systems with up to 2 stages each:
- Connect the wires in the following order: RC, Jumper, RH, G, S, O/B, Y, Y2, NTC+, NTCC, AUX/W, E/W2
- Ensure that the jumper between RC and RH is not removed.
Heat Pump (Air or Geothermal) with Auxiliary Heat
For heat pump systems with auxiliary heat:
- Connect the wires in the following order: RC, Jumper, RH, G, S, O/B, Y, Y2, NTC+, NTCC, AUX/W, E/W2
- Ensure that the jumper between RC and RH is not removed.
Boiler or Radiant System with Air Handler and Conventional Cooling or
Heating
For boiler or radiant systems with air handlers and conventional cooling or
heating:
- Connect the wires in the following order: RC, RH, NTC+, G, NTC-, S, C, O/B, AUX/W, Y, E/W2, Y2
- Ensure that the jumper between RC and RH is not removed.
Power Extender Kit Thermostat Wiring:
For power extender kit thermostat wiring:
- Connect the wires in the following order: RC, Jumper, RH, G, S, O/B, Y, Y2, NTC+, NTCC, AUX/W, E/W2
- Ensure that the jumper between RC and RH is not removed.
FAQ
Q: Can I remove the jumper between RC and RH?
A: In most cases, the jumper between RC and RH should not be removed.
However, there are specific instructions for certain systems where the jumper
should be removed. Please refer to the relevant section in the product usage
instructions for detailed information.