hysencontrol HY01RF Wireless Thermostat User Manual
- May 15, 2024
- hysencontrol
Table of Contents
User Manual HY01RF Wireless Thermostat
Many thanks for your selection of our products and services, and also for your trust and support to us
Product Specification
☆ Power: two AA 1.5V alkaline batteries
☆ Range of temperature display: 0~40°C/32~104°F
☆ Insulating condition: Normal environment
☆ Running program: Set per 1 week as a cycle
☆ Installation: Wall mounted or on battery seat
☆Working environment temperature: 0~70°C/32~122°F
☆Range of temperature adjustment: 5~35°C/41~95°F
☆ Display accuracy: 0.5°C or 1°F
☆ Output: Switch relay
☆ Probe sensor: NTC(10k)1%
☆ Size(mm): 1309027 And 10778*28
☆ Contact capacity: 16A/220V(RF electric heating)
5A/220V(RF gas boiler heating)
3A/220V(RF water heating)
Displays & Buttons
Operation Key
NO: | symbols | represent |
---|---|---|
A | SET | set key: short press it to switch programme mode to manual |
mode. At programme mode, press “+”or”-” to adjust the value, it will automatic
enter into temporary manual mode
B| +| Increasing key
C| PRG| clock key: short pressing is setting clock, long pressing
is setting programme Keys locked/unlocked:press “+”and“-”at the same time for
3 seconds
D| –| Decreasing key
E| ****| Power on/off key
Run Mode
Factory Preset Mode
Interval| Monday to Friday| the default value|
Saturday and Sunday| the default value| **
---|---|---|---|---|---
1st| 06:00-08:00| 20°C| 06:00-08:00| 20°C
2nd| 08:00-11:30| 15°C| 08:00-11:30| 15°C
3rd| 11:30-13:30| 15°C| 11:30-13:30| 15°C
4th| 13:30-17:00| 15°C| 13:30-17:00| 15°C
5th| 17:00-22:00| 22°C| 17:00-22:00| 22°C
6th| 22:00-06:00| 15°C| 22:00-06:00| 15°C
Mode| explain| printscreen
---|---|---
Programming mode| Press“ SET ”to switch into programme mode (As
shown in picture one) Programme illustration 5+2 programme function(advanced
options contain of 6+1 and 7 days programme function, you can also cancel this
programme function), that is Monday to Friday is the same setting value, and
Saturday to Sunday is the same setting value。Every day can be divided into 6
time interval Setting the programme value:long press“PRG” to enter into
programme setting mode, then short press“PRG”to switch, press“+ ”or“-”to
adjust value.|
Manual Mode| Press “SET” to enter into manual mode (As shown in
picture two), press“+”or“-”to adjust value.| **
Temporary manual mode| at programme mode,press “ +” or “-” to adjust
the value, it will automatic enter into temporary manual mode|
Sending condition ofThermostat
Send once for 20 minutes
Press on/off key
****Switch over output state
Communication instruction,be long bright display in normal communication and
blinking display in abnormal communication
Transceiver tips
Transceiver LED display instruction:
-
Power light (green light):it’s bright when power on
Signal light(orange light):it’s long bright within 10s after power on (match IP),signal light offwhen it receive match,signal light is blinking within 10s when power off. -
Load light/fault light (red light):
A, When no fault:light on when load output,light offwhen no load output
B, When fault: light is blinking and indication when fault
Signal light blink 1 time when it does not receive 485 signal for 1 hour
(light on 0.25 seconds light off 0.25 seconds), spacing out the light for 2
seconds
IP is fault(IP:FFFF),light blink 2 times (light on 0.25 seconds light off
0.25 seconds), spacing out the light for 2 seconds
Light blink 3 times when it does not receive wireless signal for 1 hour
(light on 0.25 seconds light off 0.25 seconds),spacing out the light for 2
seconds
Light blink 4 times when built-out sensor is fault (light on 0.25 seconds
light off 0.25 seconds), spacing out the light for 2 seconds
Advanced Options
Advanced options can be classified to two sets
MODE 1:
Turn off thermostat,long press SET for 3 seconds,it will display
A01-A09,then press SET to switch between these options
Display symbol | Option content | Press“+”or“-”to adjust value |
---|---|---|
temperature compensation | ||
A01) | Press “+”or“-” key to adjust setting value (—9~9 ) increment:0.5°C. | |
Start differential temperature A02) | Range:1°C~5°C: |
1. When the setting temperature is higher than or equal to the sum of indoor
temperature and the start differential temperature, the heating equipment will
turn on.
2. When the indoor temperature is higher than or equal to the sum of the
setting temperature and the start differential temperature, the heating
equipment will turn off.
| Keypad (A03)| 0 half locked:all keys are locked except for the on-off key;
1 full locked,all keys are locked including the on-off key.
| high temperature protection (A04)| Range:35~70 When the lowest setting
temperature is 35°C,press “ ”,it will display “ ”, high temperature protection
function is canceled; if the indoor temperature is higher than the high
temperature protection value,the heating equipment will be cut off.
| low temperature protection (A05)| Range:5°C~10°C ;When the highest setting
temperature is 10°C,press “ ”,it will display “ ”, low temperature
protection function is canceled; if the indoor temperature is lower than the
low temperature protection value,the heating equipment will turn on.
| setting temperature lowest limiting value(A06)| Range:1°C~10°C:
| setting temperature highest limiting value (A07)| Range:30°C~70°C
| Week programme choice(A08)| WON TUE WED THU FRI SAT SUN : represent 7days
programme
WON TUE WED THU FRI SAT :represent6+1 programme
WON TUE WED THU FRI :represent5+2 programme “ ”represent programme is canceled
| Transceiver I P check ( A 0 9 ):| Within 10 seconds after transceiver power
on,press “ + ”key shortly,check transceiver .Check successfully as shown
MODE 2:
Turn off thermostat, long press “ PRG” for 3 seconds it will display
B01-B08,then press “ SET” ” to switch between these options
Display symbol | Option content | Press“+ ”or“-”to adjust value |
---|---|---|
version number (b01) | version number 1.0 | |
IP high Setting (b02) | Press “+ ”or“ -” key to adjust setting value ( 0 ~ F |
F )
| IP low setting (b03)| Press “+ ”or“ -” key to adjust setting value ( 1 ~ F F
)
| Write transceiver IP address (b04)| Within 10 seconds after transceiver
power on, press“+”key to send address
| valve controlling selection (b05)| Press “ + ”or“ – ” key to adjust setting
value, 0 valve is controlled by thermostat, 1 valve is not controlled by
thermostat, Keep valve in closed state
| Descaling function (b06)| Press“+ ”or“-”key to adjust setting value, 0 turn
off, 1 turn on Descaling function:continue to close valve for 100 hours and
force to open valve for 3 minutes
| Degrees Celsius and Fahrenheit selection (b07)| 0= °C
1= °F
| Factory reset (b08)| Display Ao, long press PRG key,show all setting key and
factory reset
Wiring Diagram
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>