coolcenter MC130LV Solid Door User Manual

May 15, 2024
CoolCenter

coolcenter-LOGO

coolcenter MC130LV Solid Door

coolcenter-MC130LV-Solid-Door-PRODUCT

Product Specifications

  • Model Options : MC130UV, MC130URST (solid door), MC130LV, MC130LVW (glass door)
  • Power Supply : 230 V/50 Hz
  • Refrigerant: R290/R600a
  • Cooler Cable Length : 1.5m
  • Fuse Requirement : 10A
  • Electrical Wiring Code : Green/Yellow: Earth, Blue: Neutral,
  • Brown : Live

Product Usage Instructions:

Important Safety Instructions:

  1. Read the instruction manual for full use of the cabinet.
  2. Operate the appliance according to the given instructions.
  3. Contact the dealer in case of malfunctions.
  4. Place the cabinet in a dry and ventilated place away from heat sources and direct sunlight.
  5. Avoid storing inflammable materials inside the cabinet.
  6. No asbestos or CFC is used in construction.
  7. Do not defrost with mechanical devices or use electrical appliances inside the storage compartment.

Electrical Connection:

  • The cabinet operates on 230 V/50 Hz power supply.
  • Do not use extension cords for plugging the unit into a socket.
  • All earthing requirements must be observed.
  • Connect to a normal socket with a 10A fuse.

Unpacking and Installation:

  • The cooler can be single-mounted or built into furniture.
  • Ensure minimum installation distances for proper functioning.
  • Install back wall stoppers to avoid installation too close to the wall.
  • Level the cabinet using the adjustable legs provided.
  • Clean the cabinet before use and wait 2 hours if horizontally transported before starting up.
  • The freezer is equipped with a lock in the control panel.

FAQ:

  • Q: Can I use an extension cord to plug in the unit?
    • A : No, it is recommended not to use extension cords for plugging the unit into a socket. The wall socket should be easily accessible.
  • Q: What should I do if the cabinet malfunctions?
    • A : Contact your dealer immediately in case of any malfunctions for proper assistance and repair.

Important safety instructions

  1. To obtain full use of the cabinet, we recommend reading this instruction manual.
  2. It is the user’s responsibility to operate the appliance under the instructions given.
  3. Contact your dealer immediately in case of any malfunctions.
  4. Place the cabinet in a dry and ventilated place.
  5. Keep the cabinet away from strongly heat-emitting sources and do not expose it to direct sunlight.
  6. Always keep in mind that all electrical devices are sources of potential danger.
  7. Do not store inflammable material such as thinner, gasoline etc. in the cabinet.
  8. We declare that no asbestos nor any CFC are used in the construction.
  9. The oil in the compressor does not contain PCB.

ONLY FOR APPLIANCES WITH REFRIGERANT R290/R600a!

This appliance contains a flammable refrigerant, so make sure of good ventilation around theappliance. Do not use mechanical devices when defrosting, this can cause leakage of the cooling system. Do not use electrical appliances inside the refrigerated storage compartment.
Any repair of the appliance should be carried out by a skilled technician (EN 60335-2-89: 2010). Electrical connecting

The cabinet operates on 230 V/50 Hz.

A cooler is equipped with 1,5m cable. The wall socket should be easily accessible. Never use an extension cord for plugging the unit into a socket.

All earthing requirements stipulated by the local electricity authorities must be observed. The cabinet plug and wall socket should then give the correct earthing. If in doubt, contact your local supplier or authorized electrician. The cooler can be connected to a normal socket with 10A fuse.
The wires in this main lead are colored in accordance with the following code: Green/Yellow: Earth, Blue: Neutral, Brown: Live.
All electrical connections must be done by skilled electricians.

Unpacking and installation

This cooler can be single mounted or it can be built into the furniture. If you want to build in your cabinet, please note the following required minimum installation distances:

  1. There must be at least 50 mm free space above the cabinet in order for the cooling system to work satisfactorily.
  2. There must be sufficient space at the hinge side to clean and replace the shelves and clean around the hinge.
  3. There are two back wall stoppers (2 pcs) packed along the unit. These stoppers have to be installed on the cooler’s back wall in order to avoid installation too close to the wall.

Remember to attach these stoppers before installation, or to ensure that they are already installed in their place.

To ensure correct function it is important that the cabinet is level. The cabinet is supplied with legs (4pcs), these can be adjusted. See fig. 1.1.

coolcenter-MC130LV-Solid-Door-FIG1

Before use, we recommend that the cabinet is cleaned, see the section on maintenance and cleaning.

Important!

If the cabinet has been horizontally placed during transport, please wait 2 hours before starting up the cabinet.

Lock

The freezer is supplied with a lock in the control panel. See Pic 1.2

coolcenter-MC130LV-Solid-Door-FIG2

Thermostat

The cooler is equipped with electronic temperature control. The electronic thermostat (Dixell XR02CX) is located on the upper panel. See Pic 1.3

coolcenter-MC130LV-Solid-Door-FIG3

Setting the cooler temperature:

Electronic temperature control unit

  1. Light switch
  2. Snowflake/defrost-button
  3. SET-button
  4. Temperature setting up/down
  5. The power switch (turns off the compressor) Does not work as a main switch!

Temperature can be changed by the following way:

The thermostat has been pre-set, and in most cases, it is not necessary to adjust the settings.

The factory setting for the temperature is +5°C and the difference 2 degrees. (If for some reason difference wishes to be modified, please contact the manufacturer)

When turning on the cabinet the display will show the current temperature in the cabinet.

Display set temperature:

Press this key and the display will show the set temperature. Press the key again to return to normal reading

Set new temperature:

Press this key continuously for more than 3 seconds and the display shows the set temperature

Press this key to increase the set temperature.

Press this key to lower the set temperature.

Press this key to save the new settings. The display will flash with the new value and will then return to normal reading.

Alarm codes:

‘P1 ’ Flashing in the display: indicates that the cabinet sensor is defective.The cabinet will strive to keep the set temperature until it has been repaired.

‘P2 ’ Flashing in the display: indicates that the evaporator sensor is defective.

This does not influence the operation of the cabinet but should be repaired as soon as possible.

During the automatic defrost, a snowflake icon appears on the screen.
This is a fully automatic operation and does not require any action from the user.

Defrosting

The cooler defrosts automatically when the compressor stops. Defrosting water runs into a basin next to the compressor where it automatically evaporates.

Maintenance and cleaning

Remove cooler plug from the socket.

The cabinet must be periodically cleaned. Clean the external and internal surfaces of the cabinet with a light soap solution and subsequently wipe dry. External surfaces, if stainless steel, can be maintained using steel oil.

Do NOT use cleansers containing chlorine or other harsh cleansers, as these can damage the stainless steel surfaces and the internal cooling system.

Clean the condenser and compressor compartment of the refrigeration unit regularly at least once a year by vacuuming and using a brush lightly, more often depending on the conditions.

Do not use a sprinkler near or direct on the refrigerator. This could cause a short circuit and damage the electrical parts.

Service

The cooling system is a hermetically sealed system and does not require supervision, only

cleaning.

If the cabinet fails to cool, check if the reason is a power cut. If you cannot locate the reason to the failure of the cabinet, please contact your supplier. Please inform model and serial number of the cabinet. You can find this information on the rating label which is placed inside the cabinet in the top right hand side.

Disposal

Disposal of the cabinet must take place in an environmentally correct way. Please note existing regulations on the disposal for WEE products. There may be special requirements and conditions which must be observed. In professional use manufacturer is responsible to cover costs related  to WEE-waste scrapping. This unit can be supplied as WEE-waste to the recycling center without costs. Manufacturer/importer has paid recycling costs

Technical Data

  • Model: MC130
  • Defrosting: automatic
  • Cooling: fan assisted
  • Temperature control: electronic type: Dixell XR02CX
  • (K x L x S) mm : 850 x 600 x 600 mm
  • (K x L x S) mm: 620 x 510 x 485 mm
  • Net weight: 47 kg
  • Gross weight: 52 kg
  • (K x L x S) mm: 910 x 610 x 650 mm
  • Net volume: 119 l
  • Gross volume: 130 l
  • Rated Input power: 100 W
  • Temperature: +5°C
  • Energy consumption: 1,12 kWh/24h
  • Noise level: 44 dB
  • Refrigerant: R600a, 35 g
  • Voltage/Frequency, V/Hz : 230V / 50Hz
  • Climate class: class 4 (+30°C / 55%RH)
  • Certificates: CE, EC Declaration of Conformity (LVD) 2014/35/EU, (EMC) 2014/30/EU, (RoHS) Directive 2011/(MD) 2006/42/EC 65/EC

Manufactured / Imported by:

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals