“`html

Specifications:

  • Product: Amiral Plug-In Modules
  • Operating Voltage: 230V/50Hz
  • Refrigeration Control: Dixell XR77
  • Installation: Parallel installation of separate modules
  • Temperature Control: Electronic temperature control for each
    module

Product Usage Instructions:

1. General Information:

The Amiral Plug-In Modules consist of separate modules installed
in parallel, each with its own refrigeration unit. The User
Interface (UI) module serves as the user terminal and control unit
for the automat.

2. Installation:

Follow the installation drawing and checklist provided by the
manufacturer for proper setup. Ensure the device is levelled and
all preparations are made before installation. The manufacturer’s
installer team or authorized partners should handle the
installation and operational testing.

3. Air Circulation:

Air intake for cooling is from the top of the frontal top plate,
while warm air flows out from the top of the cooling cassette.
Follow the manufacturer’s instructions for maintenance and use a
pump cart to move the modules if needed.

4. Electrical Connections:

The device operates on 230V/50Hz mains power and should be
connected to grounded sockets with a universal 10A fuse. Do not use
extension cords for connection, and all electrical work must be
done by a certified electrician.

5. Temperature Control:

Each module is equipped with electronic temperature control
(Dixell XR77) located behind the top plate. The factory sets the
optimal controller settings, and only a service technician
authorized by the manufacturer should make adjustments.

Frequently Asked Questions (FAQ):

Q: Can I modify the size of the automat and add more

modules?

A: Yes, you can modify and expand the automat with additional
modules according to your needs. Contact the manufacturer for
guidance on possibilities.

Q: What should I do if I notice a fault in the operation of the

product?

A: Contact the seller’s/manufacturer’s service immediately for
assistance with any operational faults.

“`

USER MANUAL
AMIRAL PLUG-IN MODULES
1

EN
IMPORTANT SAFETY INSTRUCTIONS
1. Before commissioning the automatic machine and in order to achieve optimal operating characteristics,
1. we recommend reading this user manual. 2. It is the user’s responsibility to operate the machine in accordance with the instructions provided. 3. If you notice a fault in the operation of the pruduct, contact the seller’s/manufacturer’s service
immediately. 4. Place the modules in a dry and ventilated place. 5. Do not place the modules in the immediate vicinity of another heat-giving device or expose it to
direct sunlight. 6. Please note that there is always a risk associated with electrical appliances and their use. 7. Never store flammable liquids such as thinner, gasoline, etc. in the compartments inside the
modules. 8. We confirm that no asbestos or other environmentally harmful CFCs have been used in the
manufacture.
GENERAL
Automat consists of separate Amiral-modules installed in parallel, each with its own separate refrigeration unit. The UI (UserInterface) -module operates as an user terminal and control unit for the automat.
The modules are connected to each others and installed as a complete grocery automat that meets the customer’s demand. Automat can be located on the middle floor or against the wall. If necessary, the automat size can be modified and expanded with additional modules according to the need. Ask the manufacturer about the possibilities.
Freezer/cooler lockers are always in separate modules. The number of doors per module may vary according to the customer’s needs. Module doors are operating with magnetic locks (Note: during a power outage, the locks remain open).
INSTALLATION AND SETTING UP THE DEVICE
Before installation take note to the manufactures´installation drawing and instructions. Upon order manufacturer confirms all details by delivering 1. Identified Installation Drawing and 2. Check List for preparing the installation site -documents.
Make sure that all preparations for the installation have been made according to the Installation Drawing and Check List provided by the manufacturer.
2

To be noted before installation; -The devices are designed for indoor installation (climate class 3, operating conditions max. +25°C / 60% relative humidity). -Refrigeration units generate heat when running, so make sure that the installation space is adequately ventilated -Pay attention to sufficient installation distances to ensure air circulation in the refrigeration equipment
Description of air circulation: Air in-take for the cooling machine is from the top of the frontal top plate. Air out-take (warm air flowing out) is forced by fans upwards from the top of the cooling cassette.
-ethernet ­ (RJ45) correct location of the plug (wired internet) -location and number of sockets -size and number of fuses
To facilitate maintenance, pay attention to the manufacturer’s instructions. The modules can be moved with a pump cart. There are 4 adjustment legs under the device. Make sure the device is installed levelled. The installation and operational testing of automat is always carried out by the manufacturer’s own installer team or partners specifically authorized by the manufacturer. Additionally the Software Provider always participate in the final operational testing.
ELECTRICAL CONNECTIONS
The device operates on 230 V/50 Hz mains power. The modules are suitable for connection to normal grounded sockets with a universal 10A fuse. Never use an extension cord for connecting the device. All electrical work must be done by a certified electrician.
TEMPERATURE CONTROL
Each module of the automat is equipped with electronic temperature control (Dixell XR77) Each module has its own controller, which can be found at the top of the device behind the top plate.
3

The refrigeration controller can be found behind the top plate.
The optimal settings of the controller are pre-adjusted at the factory by the manufacturer. The settings should be changed only by a service technician authorized by the manufacturer.
DEFROST
The modules of the automat work with an automatic defrosting. The defrosted water is directed to an internal water pool, from where it automatically evaporates.
MAINTENANCE AND CLEANING
The inner and outer surfaces of the vending machine as well as door seals should be regularly cleaned with a mild detergent. After this, dry the surfaces. Do not use substances that contain bleaching or other chemical ingredients when cleaning, as these may damage surfaces. Each module has its own separate refrigeration and freezing machinery. NEVER rinse the compressor compartment with water, as this may cause short circuits and damage to electrical components. All modules have their own power cable. The condenser is located at the top of the module, behind the top plate. The top plate can be removed by gently lifting.
It is recommended to clean the condenser at least two (2) times / year or as needed. The customer can take care of the cleaning themselves or ask the manufacturer for a service offer. Separate service agreement from the manufacturer available on request. If the device does not work due to clogging of the condenser, the warranty does not cover the maintenance costs.
4

The condenser is located at the top of the device, behind the top plate.
MAINTENANCE AND POSSIBLE MALFUNCTIONS
If your devices experience software problems, check for the following possible causes:
– The power cord is disconnected or broken – The Ethernet cable is not connected, assembled wrongly or broken -The fuse is broken – Power outage
If the problem persists, contact Core Factory Oy’s service.
If the appliance experiences refrigeration problems or breakdowns of mechanical parts, contact the manufacturer’s service.
Mechanical parts include:
-Doors -Gaskets -Handle -Led- lights -Locks -or other structural element
When contacting the service, mention: o Precise location of the device o Your other contact information o As accurate description of the problem as possible
The product plate of each module can be found on the back wall of the device.
DISPOSAL
5

The disposal of refrigeration equipment must be carried out in an environmentally friendly manner as required by law. Please note the current regulations regarding the disposal of refrigeration equipment.
In professional use, the costs of disposing of WEEE waste are borne by the manufacturer of the product. The costs of recycling WEEE waste have been paid by the manufacturer of this equipment and can be delivered to the WEEE waste recycling centre free of charge.

TECHNICAL SPECIFICATIONS
The automat may consist of the Admiral -modules described below;

USER INTERFACE External dimensions (W x D x H) Net weight (kg): Fuse: Connection power (W): Operator display:

300 x 802 x 2365 mm 105 kg 10 A 650 10″ Touch screen

The module includes the automation supplier’s equipment and a temperature monitoring control unit.

C9/C12/C15 External dimensions (W x D x H): Internal dimensions (W x D x H): 15 cooler lockers Doorway (W x H): Net weight (kg): Temperature range: Fuse: Net volume (l): Connection power (W): Defrost: Refrigerant: Thermostat: Climate class: Operating conditions:

1470 x 802 x 2365 mm 449 x 605 x 389 mm 370 x 305 mm 319 kg +4…+8º C 10 A 1508 litres 336 W Automatic R290 Electronic 3 Max +25 ºC / 60 % relative humidity

F10/F14 External dimensions (W x D x H): Internal dimensions (W x D x H): 14 freezer lockers
Doorway (W x H): Net weight (kg): Temperature range: Fuse:

980 x 802 x 2365 mm 430 x 605 x 398 mm (big, 2 lockers) 430 x 605 x 262 mm (small, 12 lockers) 370 x 173 mm (small), 370 x 305 mm (big) 276 kg -18…-20º C 10 A

6

Net volume (l): Connection power (W): Defrost: Refrigerant: Thermostat: Climate class: Operating conditions:

964 litres 732 W Hot gas R290 Electronic 3 Max +25 ºC / 60 % relative humidity

WARRANTY
The devices have a 2-year operating warranty guaranteed by the manufacturer. The warranty terms are determined by Coolcenter Forssa Oy’s general delivery terms.

The software supplier is responsible for the hardware of the automated operating software (touch screen, PC, RFID reader, router, etc.) as well as programming, functional testing and user guidance for the customer. The software provider defines and is separately responsible for their warranty.

Service contact
Coolcenter Forssa Oy Sipilänkatu 11 30100 FORSSA, Finland
Matti Moisander tel. +358 50 3560987 email: service@coolcenter.fi