KOHLER 1538434-2-A Linear Chandelier Installation Guide

May 15, 2024
Kohler

KOHLER 1538434-2-A Linear Chandelier

KOHLER-1538434-2-A-Linear-Chandelier-product

Product Information

Specifications

  • Product Name: Linear Chandelier
  • Model Number: 1538434-2-A
  • Manufacturer: KOHLER
  • Max Bulb Wattage: 40W
  • Bulb Type: E12 base Type T (bulbs not included)
  • Usage: Indoor Only

Product Usage Instructions

  1. Before You Begin
    Ensure electricity is turned off at the circuit breaker or fuse box before installation. The electrical outlet box must be properly grounded.

  2. Prepare the Site
    Remove the mounting plate from the canopy by unthreading the thumb nuts from the canopy.

  3. Install the Mounting Plate
    Securely attach the mounting plate to the electrical outlet box using anchor screws and mounting screws.

  4. Connect the Downrods
    Connect the downrods to the chandelier using the swivel joint.

  5. Attach the Downrods to the Canopy
    Insert the electrical wires through the canopy and secure them using nuts, washers, and safety wire.

  6. Connect the Safety Wire (If Applicable)
    Attach the safety wire to the mounting plate securely using a clamp and M2 hex wrench.

  7. Connect the Electrical Wires
    Cut down the electrical wires to an appropriate length and connect them following electrical standards. Ensure proper grounding.d

Frequently Asked Questions (FAQ)

  • Q: Can this chandelier be installed on a sloped ceiling?
    A: Yes, if mounting on a sloped ceiling, ensure that the length of the mounting plate is perpendicular to the slope of the ceiling.

  • Q: What is the maximum bulb wattage supported by this fixture?
    A: The fixture has been rated for bulbs up to 40W. Do not exceed this rating.

Thank You for Choosing KOHLER

Need help? Contact our Customer Care Center.

Warranty

This product is covered under the KOHLER® Indoor Lighting Fixtures Limited Warranty, found at kohler.com/warranty. For a hard copy of warranty terms, contact the Customer Care Center.

Tools and Materials

KOHLER-1538434-2-A-Linear-Chandelier- \(1\)

Plus:

  • Max 40 W E12 Base T Bulb

Before You Begin

KOHLER-1538434-2-A-Linear-Chandelier- \(2\)

DANGER: Risk of electric shock. To avoid electrical shock, the electricity must be turned OFF at the circuit breaker or fuse box before beginning installation.
DANGER: Risk of electric shock. To avoid electrical shock, the electrical outlet box must be properly grounded.
CAUTION: Risk of property damage. To avoid risk of fire, this fixture has been rated for bulbs up to 40 W. Do not exceed this rating.
IMPORTANT! Do not exceed recommended wattage. Rated Max 40 W E12 base Type T bulb(s) not included.
NOTE: If mounting on a sloped ceiling, the length of the mounting plate must be perpendicular to the slope of the ceiling.

Follow all local plumbing, building, and electrical codes.
Please read all instructions before you begin.

  • The fixture should be installed by a qualified electrician.
  • This fixture is for indoor use only.

Carefully inspect the fixture for damage.

Prepare the Site

KOHLER-1538434-2-A-Linear-Chandelier- \(3\)

Remove the mounting plate from the canopy by unthreading the thumb nuts from the canopy.

Install the Mounting Plate

KOHLER-1538434-2-A-Linear-Chandelier- \(4\)

  • Temporarily install the mounting plate.
  • Position the flat side of the mounting plate flat against the electrical outlet box.
  • Align the mounting holes on the mounting plate with the holes on the electrical outlet box.
  • Mark the outer holes of the mounting plate.
  • Remove the mounting plate.
  • Drill the holes for the ceiling anchors (use a 1/4″ drill bit for concrete or a 3/8″ drill bit for drywall/wood).
  • Insert the appropriate anchors (provided) into your ceiling. The anchors are not load bearing and are used to keep the entire canopy flat against the ceiling.
  • Reinstall the mounting plate onto the electrical outlet box and insert the anchor screws (included) into the ceiling. Carefully pull out the electrical wires from the electrical outlet box and allow the electrical wires to hang down. Securely tighten the mounting plate to the electrical outlet box with the mounting screws (included).

Connect the Downrods

KOHLER-1538434-2-A-Linear-Chandelier- \(5\)

  • Determine the height that you want the fixture to be located. Select a combination of different length downrods that will position the fixture at the desired height.
  • Insert the electrical wires from the chandelier through one of the downrods without threads. Thread that downrod onto the chandelier.
  • Insert the electrical wires through each downrod and then thread the downrods together one at a time.
  • Insert the electrical wires through the swivel joint. Thread the swivel joint onto the end of the downrods.
  • Thread the other downrod without threads onto the chandelier.
  • Thread the remaining downrods and swivel joint together.
  • Verify that both swivel joints are facing the same direction and perpendicular to the length of the fixture.

Attach the Downrods to the Canopy

KOHLER-1538434-2-A-Linear-Chandelier- \(6\)

  • Insert the electrical wires through the canopy.
  • Insert the ends of the swivel joints into the canopy.
  • Position the serrated washer, the flat washer, and then thread the nut onto the swivel joint with the electrical wires. Position the serrated washer and the flat washer on the other swivel joint without the electrical wires.
  • Attach one end of the safety wire on the swivel joint without the electrical wires. Thread the nut onto the swivel joint. Securely tighten the nuts.

Connect the Safety Wire (If Applicable)

KOHLER-1538434-2-A-Linear-Chandelier- \(7\)

  • Loosen the clamp on the safety wire using the provided M2 hex wrench. Pull the end of the safety wire out.
  • With two people, lift the fixture up to the ceiling to attach the safety wire to the mounting plate.
  • Loop the safety wire around the mounting plate.
  • Insert the end of the safety wire into the clamp and tighten the clamp using the provided M2 hex wrench.
  • Verify that the safety wire and clamps are securely tightened.

Connect the Electrical Wires

KOHLER-1538434-2-A-Linear-Chandelier- \(8\)

  • If needed, the length of the electrical wires can be cut down to 6″ (152 mm) – 12″ (305 mm) longer than the downrods.
  • Make a loop in the ground wire and wrap around the grounding screw on the mounting plate. Tighten the grounding screw.
  • Attach the ground wire (bare copper), from the fixture, to the ground wire (usually bare copper or green) in the electrical outlet box.
  • Fasten the ground wires together with the provided wire nut and wrap the wire nut with electrical tape.
  • Attach the neutral wire (with the grooves), from the fixture, to the neutral wire (usually white) in the electrical outlet box.
  • Fasten the neutral wires together with the provided wire nut and wrap the wire nut with electrical tape.
  • Attach the hot wire (with the writing), from the fixture, to the hot wire (usually black) in the electrical outlet box. Fasten the hot wires together with the provided wire nut and wrap the wire nut with electrical tape.

Secure the Fixture

KOHLER-1538434-2-A-Linear-Chandelier- \(9\)

  • Verify that all plastic wire nuts are securely fastened and strands of bare wire are not exposed.
  • Carefully position the electrical wires inside the electrical outlet box behind the mounting plate.
  • With two people, lift the chandelier and position the canopy over the mounting plate. Align the two holes in the canopy with the screws in the mounting plate.
  • Secure the canopy to the mounting plate with the two provided thumb nuts.

Install the Shade

KOHLER-1538434-2-A-Linear-Chandelier- \(10\)

  • Remove the socket ring from each of the light bulb sockets.
  • If the rubber washer is not attached to the socket ring, remove the rubber washer from the light bulb socket. Position the rubber washer inside the glass shade so that the rubber washer sits flat at the bottom of the glass shade and around the light bulb socket.
  • Position the glass shade onto the light bulb socket.
  • Insert the socket ring tool into the two holes at the base of the socket ring.
  • Using the socket ring tool, insert the socket ring into the glass shade and thread the socket ring onto the light bulb socket. Tighten the socket ring.
  • Repeat for all glass shades.
  • Gently twist the light bulb tool over the end of the light bulb(s).
  • Insert the light bulb(s) into the light bulb socket(s).
  • Turn ON the main electrical supply from the main fuse or circuit breaker.
  • Confirm proper operation.

kohler.com
©2023 Kohler Co.
1538434-2-A

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals