CFI V3W Vaporlume LED Wet Location Instruction Manual

May 15, 2024
CFI

Day-Brite
V3W Vaporlume LED Wet Location

Instruction Manual

INSTALLATION INSTRUCTIONS

CAUTION : THE INSTALLATION AND SERVICING OF THIS PRODUCT SHOULD BE PERFORMED BY A QUALIFIED ELECTRICIAN OR SERVICE PERSONNEL.
UNIT IS FULLY ASSEMBLED AND READY TO INSTALL. IF ACCESS TO THE WIRING COMPARTMENT IS NEEDED, USE THE FOLLOWING PROCEDURE.
WARNING: DO NOT PENETRATE HOUSING. THIS WILL VOID WET LOCATION LISTING.

  1. REMOVE LENS FROM FIXTURE BY OPENING RETAINING LATCHES. (SEE FIG 1) CAREFULLY SET LENS TO THE SIDE.
  2. WHILE SUPPORTING THE LED BOARD TRAY, REMOVE THE SCREW AT EACH END OF THE TRAY. (SEE FIG 2) ENSURE THAT THE LED BOARD LEADS ARE NOT PUT UNDER TENSION WHILE CAREFULLY LOWERING THE BOARD TRAY UNTIL IT IS SUSPENDED BY THE TWO PLASTIC LANYARDS. (SEE FIG 3)
  3. MAKE ALL WIRING CONNECTIONS TO FIXTURE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND ALL APPLICABLE LOCAL CODES.
  4. REPLACE BOARD TRAY BY REVERSING PROCESS IN STEP 2.
  5. REPLACE LENS BY REVERSING PROCESS IN STEP 1. ENSURE ALL LATCHES ARE PROPERLY SECURED.CFI V3W Vaporlume LED Wet Location

STANDARD CONDUIT MOUNTING (FIG 4) MUST BE ATTACHED TO SUPERSTRUCTURE ADEQUATE TO SUPPORT FIXTURE. FOR OTHER MOUNTING OPTIONS, SEE ADDITIONAL INSTRUCTION SHEETS.

CFI V3W Vaporlume LED Wet Location - designed

NOTES:

  • DO NOT REMOVE HUB FROM FIXTURE.
  • FACTORY INSTALLED HUB PLUG MUST REMAIN IN FIXTURE AT END OF ROW.
  • FEED WIRE NUTS THROUGH CONDUIT HUB AFTER WIRES HAVE BEEN CONNECTED.

CAUTION : This fixture is designed for permanent installation in ordinary (Non-Hazardous) locations in accordance with the National Electrical Code and all applicable local codes. Do not use in areas of limited ventilation or in high ambient enclosures. The lamp and fixture operate at high temperatures.
Contact with combustible materials can cause fire and personal contact can cause severe burns.
CAUTION : THE INSTALLATION AND SERVICING OF THIS PRODUCT SHOULD BE PERFORMED BY A QUALIFIED ELECTRICIAN OR SERVICE PERSONNEL

MOUNTING STUD LOCATIONS:
TWO 1/4-28 MOUNTING STUDS ARE PROVIDED FOR THE ATTACHMENT OF VARIOUS MOUNTING ACCESSORIES.
REFER TO FIGURE 5 FOR THE STUD SPACING.

CFI V3W Vaporlume LED Wet Location - STUDS

CAUTION : This fixture is designed for permanent installation in ordinary (Non-Hazardous) locations in accordance with the National Electrical Code and all applicable local codes. Do not use in areas of limited ventilation or in high ambient enclosures. The lamp and fixture operate at high temperatures.
Contact with combustible materials can cause fire and personal contact can cause severe burns.

Signify Corporation North America
200 Franklin Square Drive
Somerset, NJ 08873
Phone: 855-486-2216
www.day-brite.com| Signify Canada Ltd./Signify Canada Ltée.
281 Hillmount Road Markham
ON, Canada L6C 2S3 Phone: 800-668-9008
www.cfi-lighting.com
---|---

Day-Brite

Documents / Resources

| CFI V3W Vaporlume LED Wet Location [pdf] Instruction Manual
V3W Vaporlume LED Wet Location, V3W, Vaporlume LED Wet Location, LED Wet Location, Wet Location, Location
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

CFI User Manuals

Related Manuals