PRODUCT

READ AND SAVE THESE INSTRUCTIONS

Package Contents

  • Cool Mist Humidifier
  • 3X Essential Oil Wicks

Specifications

  • Nominal voltage: 120VAC/60Hz
  • Output: 250ml/h Max
  • Power: 22W
  • Water tank capacity: 1gal (3.8L)

WARNING
Read the ENTIRE instruction manual to become familiar with the features of the humidifier before operating. Failure to operate the humidifier correctly can result in damage to the humidifier, risk of electric shock, fire or serious personal injury. Do not attempt disassembly or use with incompatible components. This manual contains instructions for safety, operation and maintenance. It is essential to read and follow all the instructions and warnings in the manual, before setup or use, to operate correctly and avoid damage or serious injury.

IMPORTANT SAFEGUARDS

READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS BEFORE USING THIS APPLIANCE. WHEN USING ELECTRICAL APPLIANCES, PRECAUTIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK AND INJURY TO PERSONS, INCLUDING THE FOLLOWING:

  • The humidifier should always be placed on a firm, flat, waterproof surface at least four feet away from the bedside, five inches from the wall, and away from sunlight. Keep away from computers or sensitive electronic equipment.
  • KEEP OUT OF REACH OF CHILDREN. THIS HUMIDIFIER IS NOT A TOY! Do not let your child play with this humidifier. Serious injury and electrocution might be possible.
  • This humidifier must be operated by an adult only. Children should be supervised to ensure that they do not play with this humidifier.
  • Be sure the appliance is in a stable position and the power cord is away from heated surfaces and out of the way to prevent the humidifier from being tipped over.
  • Before using the humidifier, extend the cord and inspect for any signs of damage. use the unit if the cord has been damaged.
  • The humidifier has a polarized plug (one blade is wider than the other) as a safety feature.
  • This plug will fit into a polarized outlet only one way. If the plug does not fit fully into the outlet, reverse the plug. If it still does not fit, contact a qualified electrician.
  • DO NOT attempt to defeat this safety feature.
  • To avoid fire or shock hazards, plug the appliance directly into a 120V AC electrical outlet.
  • In the event of a malfunction, unplug the humidifier and cease use.
  • Do not use the humidifier for any other purposes than its intended use. Any other use is to be deemed inappropriate and hazardous.
  • Caution: To avoid the risk of fire, shock or personal injury, do not use an extension cord.
  • For household use only. Do not use outdoors.
  • The humidifier should always be unplugged and emptied when not in operation or while being cleaned.
  • Shut off and unplug the humidifier before moving.
  • Do not move or tilt the humidifier while it is in operation.
  • Plug and unplug the humidifier with dry hands. NEVER pull by the cord.
  • Do not operate the humidifier without water. Turn off and unplug the humidifier when the tank is empty.
  • Do not add any medications or essential oils to the nozzle, water reservoir or water tank. SAVE THESE INSTRUCTIONS

Parts of The Cool Mist Humidifier

Dr Browns-AN008-Ultrasonic-Cool-Mist-Humidifier-with-Night-Light-FIG-
\(1\)Dr Browns-AN008
-Ultrasonic-Cool-Mist-Humidifier-with-Night-Light-FIG-
\(2\)

  1. Air Outlet
  2. Water Reservoir
  3. Transducer
  4. Main Housing
  5. Night Light Button
  6. Water Level Sensor
  7. Power Indicator/Low Water Level
  8. Output Controller
  9. Mist Outlet
  10. Essential Oil Wick
  11. Essential Oil Reservoir
  12. Tank Carry Handle
  13. Water Tank
  14. Tank Sealing Cap/Valve

OPERATING INSTRUCTIONS

Always UNPLUG the humidifier before filling.

Fill the water tank

  1. Remove the tank from the base of the humidifier. Turn the water tank upside down.
  2. Remove the tank sealing cap/valve by unscrewing it counterclockwise.
  3. Fill the tank with clean, cool, tap water or distilled water.
  4. Replace the tank cap/valve by screwing it clockwise tightly.
  5. Replace the tank in the base of the humidifier.
  6. Within a few seconds the base of the humidifier will fill up with water and be ready to operate.Dr Browns-AN008-Ultrasonic-Cool-Mist-Humidifier-with-Night-Light-FIG- \(3\)

NIGHT LIGHT OPERATION
Dr Browns-AN008-Ultrasonic-Cool-Mist-Humidifier-with-Night-Light-FIG-
\(4\)

  1. To turn the night light on, press the light button.
  2. Continue pressing to adjust the brightness to your preferred level.
  3. To turn the night light off, press the light button again until the light turns off.

USING YOUR HUMIDIFIER
Dr Browns-AN008-Ultrasonic-Cool-Mist-Humidifier-with-Night-Light-FIG-
\(5\)

  1. Connect the power cable to an available power outlet.
  2. The indicator light will illuminate.
  3. Turn the mist level control clockwise to the desired output to activate the humidifier.
  4. Aim the mist outlet in the desired direction.
  5. To avoid moisture damage to your belongings, ensure that the mist outlet is not directed towards walls, plugs, or furniture.

EMPTYING YOUR HUMIDIFIER

  1. Turn off the humidifier, turn the switch to the Off position and unplug the Humidifier. The indicator light should not be illuminated.
  2. Remove the water tank from the base.
  3. Remove the tank sealing cap/valve by unscrewing it counterclockwise.
  4. Empty any remaining water from the tank and base, then wipe any remaining water with a dry cloth or towel.

USING THE ESSENTIAL OILS FRAGRANCE FEATURE

  1. Remove the mist nozzle from the humidifier.

  2. Pull out the essential oil wick retainer from the mist outlet path.

  3. Insert the wick into the retainer.

  4. Place 2-4 drops of essential oil or aroma oil into the wick. (These oils are available commercially).
    Note: Do not fill the wick in the humidifier as spilt oils can hinder the operation of the humidifier.

  5. Insert the retainer into the humidifier mist outlet path.

  6. Replace the mist nozzle with the humidifier.

  7. To start operation follow the normal operation instructions above. If essential oils or aroma oils are not added, your humidifier will function as a regular humidifier.

TROUBLESHOOTING

If the humidifier is not operating check that:

  1. The power cable is connected to the power outlet.
  2. The mist level control switch is turned to an On position.
  3. The water tank has been properly assembled onto the humidifier base.
  4. There is sufficient water in the tank.
  5. The water level pressure is properly seated.

MAINTENANCE – Care and Cleaning

Daily Maintenance

  1. Turn off, unplug from the outlet and empty water from the tank and base daily.
  2. Clean with a soft cloth or sponge. Allow the water tank to dry naturally upside down (water inlet pointed up). Never immerse the base in water or any other liquid.
  3. Do not use detergent to clean any water-containing parts of the humidifier. Detergents and the film they leave behind can affect the output of the humidifier. Do not use abrasive cleansers or brushes.
  4. Do not leave water in the water tank or base when the unit is not in use as it may result in the build-up of mineral deposits and bacteria that can inhibit the output efficiency of the humidifier.
  5. If water remains in the water tank for more than a day or two, bacterial growth is possible.

Weekly Maintenance

  1. Turn off, unplug from the outlet and empty the water from the tank and base.
  2. Thoroughly clean the humidifier every week by filling the water tank halfway with warm water and adding 2 Tablespoons of white vinegar. Shake vigorously and let sit for 30 minutes.
  3. Empty water tank and rinse with plain water.

End-of-Season Maintenance

  1. Follow the above weekly cleaning procedure at the end of the humidification season, or when the humidifier will not be used for several days, being sure to dry all parts, including the inside of the water tank. Do not store water inside.
  2. Make sure all parts dry completely.
  3. Store the humidifier in a cool, dry place.

WARRANTY

This Ultrasonic Cool Mist Humidifier with Nightlight is warranted against defective material or workmanship for one year from the date of purchase. Any defective part will be repaired or replaced at no charge if it has not been tampered with and the appliance has been used according to these printed instructions. The warranty does not cover the essential oil wicks, performance of the essential oil wicks or fragrances. This Warranty gives you specific legal rights as well as other rights which vary from state to state. If you experience unsatisfactory operation or have any questions/comments, call Handi-Craft’s Customer Service at 1-800-778-9001, or write to Handi-Craft Company, Customer Service, 4433 Fyler Avenue, St. Louis, Missouri 63116 USA. Our Customer Service Representative will advise you how to correct the problem yourself or will ask you to return the product for repair or replacement. Outside of the US or Canada, please contact your local distributor.

FCC Compliance Statement

This device complies with Part 18 of the FCC Rules, Importer: Handi-Craft Company Inc., Address: 4433 Fyler Ave., St. Louis, MO 63116. This product has been tested and complies with the requirements of the Federal Communications Commission, Part 18 for Radio/TV/Communication interference. Although tested, it may affect these devices. If the humidifier is found to interfere, separate the device and/or the humidifier. Conduct only the user maintenance found in this manual. Other maintenance and servicing can cause harmful interference and can void the required FCC compliance. If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on, the user is encouraged to try to correct interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

HANDI–CRAFTCOMPANY
ST. LOUIS, MISSOURI 63116 USA/EE.UU. drbrownsbaby.com
Made in China. Fabricado en China.
May be patented in the USA, see drbrownsbaby.com/patents.
©2022 Handi-Craft Company. All Rights Reserved. F2
DR. BROWN’S and all other trademarks are owned or used under license by Handi- Craft Company

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Dr. Brown’s User Manuals

Related Manuals