Dr Brown s AC184 Insta-Feed Bottle Warmer Instruction Manual
- June 10, 2024
- Dr Brown s
Table of Contents
Dr Brown s AC184 Insta-Feed Bottle Warmer
Product Information
The Insta-FeedTM Bottle Warmer is an electrical appliance designed to warm baby bottles and food jars. It comes with a warming chamber, indicator light, power button, sterilizing lid, adapter ring, measuring cup, lift-out basket, and storage caps. The nominal voltage of the warmer is 120VAC/60Hz 500W.
Important Safeguards
- Read the entire instruction manual before operating.
- Use the detachable power-supply cord or extension cord whose electrical rating is at least as great as the electrical rating of the appliance.
- If the appliance is of grounded type, use a grounding-type 3-wire cord for extension.
- Arrange the longer cord in such a way that it does not drape over the countertop or tabletop where it can be tripped over, snagged, or pulled on unintentionally (especially by children).
Instructions for Use:
Caution: Always unplug the warmer before filling. Do not use Sterilizing Lid for warming.
-
Remove the Measuring Cup from the rear of the warmer.
-
Add water to the Measuring Cup, following the Warming Guide on page 5 to determine the amount of water to add based on your bottle type. Note: These amounts are a guide only. There are many variables that can impact the final temperature of the bottle or food jar you are warming, such as starting temperature, size, and shape. Always test the temperature before feeding your baby.
-
Pour the water from the Measuring Cup directly into the Warming Chamber. Do not overfill, as overfilling may cause the bottle/food jar to be overheated or may cause damage to the unit.
-
Replace the Measuring Cup and plug in the power cord.
Note: The first time the unit is plugged in, the warming cycle may begin automatically. If the Indicator Light is on upon plugging unit in, wait for the warming cycle to end (Indicator Light will turn off) and allow the unit to cool down for 10 minutes before using. -
Press the Power Button. The Indicator Light will turn on, indicating the warming cycle has begun. Caution: Always add water and then press Power Button. If the Power Button is pressed first, steam may form when water is added. WARNING: DO NOT reach over the appliance while in use, as steam will cause burns and serious
injuries. Do not touch hot surfaces during or immediately after use. -
Once the warming cycle is complete, remove the bottle/food jar from the Warming Chamber using the Lift-Out Basket. Note: The Lift-Out Basket may be hot. Use caution when removing it from the Warming Chamber.
Note: If the Power Button is pressed without water added, the unit will shut off automatically after a short period. If this happens, wait at least 10 minutes to allow warmer to cool before adding water and starting warming cycle.
Package Contents: Insta-Feed™ Bottle Warmer Quick Reference Guide 2x Storage Caps
Specifications:
Nominal voltage: 120VAC / 60Hz 500W
WARNING: Read the ENTIRE instruction manual to become familiar with the features of the product before operating. Failure to operate the product correctly can result in damage to the product, personal property and cause serious injury. A copy of these instructions is also available online at drbrownsbaby.com/customer-support
IMPORTANT SAFEGUARDS
WHEN USING ELECTRICAL APPLIANCES, PRECAUTIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK AND INJURY TO PERSONS, INCLUDING THE FOLLOWING:
-
Read all instructions.
-
This appliance shall not be used by children. Close supervision is necessary when any appliance is used near children.
-
Do not attempt disassembly. The use of accessory attachments is not recommended by Handi-Craft Company and may cause injuries.
-
DO NOT IMMERSE IN WATER.
-
HOUSEHOLD USE ONLY.
-
Do not touch hot surfaces. Use handles or knobs.
-
DO NOT open Sterilizing Lid or reach over the appliance while in use, as steam will cause burns and serious injuries. Do not touch lid or interior parts during use, as serious injury may occur.
-
Always remove the Sterilizing Lid carefully by the handle. Take care when removing the Sterilizing Lid as there may be some residual steam—keep hands and face away.
-
Allow the steam to clear before reaching into the unit. Always retrieve the sterilized parts by removing the Lift-Out Basket.
-
To protect against electrical shock, do not immerse cord or plug in water or other liquids.
-
Close supervision is necessary when any appliance is used near children.
-
This appliance shall not be used by children. Keep the appliance and its cord out of reach of children.
-
Before serving, unplug cord from wall outlet.
-
Unplug from outlet when not in use and before cleaning. Allow to cool before putting on or taking off parts.
-
Always unplug the warmer before filling. Do not use Sterilizing Lid for warming.
-
Do not operate any appliance with a damaged cord or plug or after the appliance malfunctions or has been damaged in any manner. Return appliance to the nearest authorized service facility for examination, repair or adjustment.
-
Misuse of the product may cause potential injury.
-
The heating element surface is subject to residual heat after use.
-
Do not use outdoors.
-
Do not let cord hang over edge of table or counter or touch hot surfaces.
-
Do not place on or near a hot gas or electric burner or in a heated oven.
-
Extreme caution must be used when moving an appliance containing hot liquids.
-
To operate, plug cord into wall outlet. To disconnect, turn any control to “off,” then remove plug from wall outlet.
-
Always add water and then press Power Button. If the Power Button is pressed first,steam may form when water is added.
-
Never freeze glass containers, as glass may break.
-
Do not use this warmer for frozen milk or food. Always thaw frozen milk or food overnight in the refrigerator first before warming.
-
Do not use appliance for other than intended use.
-
Never immerse the warmer or power cord in water.
-
When in use, the warmer contains hot water. Be careful to avoid spilling or splashing any water on yourself when removing contents from the warmer.
-
Before serving, be sure food is at a safe temperature.
-
Warming food for long periods is not recommended.
-
Food should not be heated for too long.
-
Before feeding, always check the content temperature of the bottle or the small jar.
-
This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of electric shock, this plug is intended to fit into a polarized outlet only one way. If the plug does not fit fully into the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not attempt to modify the plug in any way.
-
Before servicing, unplug cord from wall outlet. Do not leave cord within child’s reach.
-
The preheating of the appliance is not necessary.
-
A short power-supply cord is provided to reduce the risk resulting from becoming entangled in or tripping over a longer cord.
-
Extension cords (or longer detachable power-supply cords) are available and may be used if care is exercised in their use.
-
If an extension cord (or a long detachable power-supply cord) is used:
- The marked electrical rating of the detachable power-supply cord or extension cord should be at least as great as the electrical rating of the appliance;
- If the appliance is of the grounded type, the extension cord should be a grounding-type 3- wire cord; and
- The longer cord should be arranged so that it will not drape over the countertop or tabletop where it can be tripped over, snagged, or pulled on unintentionally
(especially by children).
-
Children shall not play with the appliance.
-
Any maintenance servicing should be performed by an authorized service representative.
-
NOT FOR SPACE HEATING PURPOSES.
SAVE THESE INSTRUCTIONS
PARTS OF THE INSTA-FEED™ BOTTLE WARMER
- Warming Chamber
- Indicator Light
- Power Button
- Sterilizing Lid
- Adapter Ring
- Measuring Cup
- Lift-Out Basket
- Storage Caps
WARMING BOTTLES AND FOOD JARS
CAUTION: Always unplug the warmer before filling.
Do not use Sterilizing Lid for warming.
-
Remove the Measuring Cup from the rear of the warmer.
-
Add water to the Measuring Cup, following the Warming Guide on page 5 to determine the amount of water to add based on your bottle type.
Note: These amounts are a guide only. There are many variables that can impact the final temperature of the bottle or food jar you are warming, such as starting temperature, size, and shape. Always test the temperature before feeding your baby. -
Pour the water from the Measuring Cup directly into the Warming Chamber. Do not overfill, as overfilling may cause the bottle/food jar to be overheated or may cause damage to the unit.
-
Replace the Measuring Cup and plug in the power cord.
Note: The first time the unit is plugged in, the warming cycle may begin automatically. If the Indicator Light is on upon plugging unit in, wait for the warming cycle to end (Indicator Light will turn off) and allow the unit to cool down for 10 minutes before using. -
Place the bottle or food jar inside the Warming Chamber as outlined below.
- Wide Neck Bottle: Place bottle directly into Warming Chamber.
- Narrow Bottle: Place Adapter Ring on top of Warming Chamber, then place bottle in Warming Chamber. The Adapter Ring will keep your bottle centered over the heating plate for even warming.
- Note: To prevent leakage when warming Dr. Brown’s® bottles, remove the internal parts, collar, and nipple/teat, and replace with the included Storage Cap.
- Food Jar: Place food jar into the Lift-Out Basket, then place Lift-Out Basket in Warming Chamber.
- Note: Always remove the lid of the food jar prior to warming. After warming cycle is complete, be sure to stir food thoroughly until it is an even temperature throughout.
-
Press the Power Button. The Indicator Light will turn on, indicating the warming cycle has begun.
CAUTION: Always add water and then press Power Button. If the Power Button is pressed first, steam may form when water is added.
WARNING: DO NOT reach over the appliance while in use, as steam will cause burns and serious injuries. Do not touch hot surfaces during or immediately after use.
Note: If the Power Button is pressed without water added, the unit will shut off automatically after a short period. If this happens, wait at least 10 minutes to allow warmer to cool before adding water and starting warming cycle. -
When the Indicator Light turns off, the warming cycle is done. Remove the bottle/food jar promptly to avoid overheating. Gently stir or swirl content to ensure it warms evenly.
DO NOT shake.
Note: Always test the temperature before feeding your baby. Adjust the amount of water added to the warming chamber as needed; if the bottle/food jar is too cold, add slightly more water next time. If the bottle/food jar is too warm, use slightly less water next time. -
Wait at least 10 minutes to allow warmer to cool before using again.
WARMING GUIDE
STERILIZING SMALL PARTS
CAUTION: Always unplug the warmer before filling.
The sterilize feature can be used for any small part safe for steam
sterilization. DO NOT sterilize bottles in this sterilizer.
-
Add 2 oz / 60 mL of water directly into the Warming Chamber. Do not overfill, as overfilling may cause damage to the unit.
-
Place small parts (nipples/teats, pacifiers/soothers, etc.) to be sterilized in the Lift-Out Basket.
-
Place the Lift-Out Basket with small parts into the Warming Chamber.
-
Place the Adapter Ring on top of the Warming Chamber.
-
Place the Sterilizing Lid on top of the Adapter Ring.
-
Plug in the power cord and press the Power Button. The Indicator Light will turn on, indicating the sterilizing cycle has begun.
WARNING: DO NOT open Sterilizing Lid or reach over the appliance while in use, as steam will cause burns and serious injuries. Do not touch hot surfaces during or immediately after use. -
When the Indicator Light turns off, the sterilizing cycle is done.
-
Allow the unit to cool for at least 10 minutes before removing the Sterilizing Lid,Adapter Ring, and Lift-Out Basket.
CAUTION: Be sure to observe the 10-minute cooling time as warmer parts and sterilized parts will be hot. Always remove the Sterilizing Lid carefully by the handle. Take care when removing the Sterilizing Lid as there may be some residual steam—keep hands and face away. Allow the steam to clear before reaching into the unit. Always retrieve the sterilized parts by removing the Lift-Out Basket.
TROUBLESHOOTING TIPS
- If the warmer is not operating, check that the power cable is connected to the power outlet and water has been added to warming chamber.
- If Indicator Light does not come on/warming cycle does not start, warmer may be cooling down. Wait 10 minutes and try again.
- If Indicator Light comes on upon plugging in but before Power Button is pressed, it is possible the Power Button was pressed while the warmer was unplugged. Wait for the warming cycle to end (Indicator Light will turn off) and allow the unit to cool down for 10 minutes before using.
- If bottle/food is too warm/too cold after warming cycle, note the Warming Guide only shows approximate amount of water needed. Warming times are impacted by many variables, so adjust the amount of water added as needed. If the bottle/food jar is too cold, add slightly more water next time. If the bottle/food jar is too warm, use slightly less water next time.
CLEANING THE INSTA-FEED™ BOTTLE WARMER AND PARTS
CAUTION: ALWAYS TURN OFF, UNPLUG, AND ALLOW THE UNIT TO COOL BEFORE CLEANING.
Bottle Warmer Unit: Wipe outer surface and inside the Warming Chamber with a
damp cloth or sponge using mild liquid soap. Wipe with clean water and allow
unit to air dry. DO NOT SUBMERGE UNIT IN WATER.
Lift-Out Basket, Adapter Ring, Sterilizing Lid, and Measuring Cup: Dishwasher
safe
(top rack only) or wash with soapy water. Rinse with clean water and allow to
air dry.
DE-SCALING THE INSTA-FEED™ BOTTLE WARMER
It is recommended to de-scale you Insta-Feed™ Bottle Warmer every four weeks
to ensure the unit continues to work properly. To de-scale, follow the steps
below.
- Unplug the appliance from power.
- Mix 2 oz / 60 mL of white vinegar with 4 oz / 120 mL of water. DO NOT USE BLEACH.
- Pour the white vinegar and water mixture directly into the Warming Chamber.
- Allow the mixture to stand in the unit until any mineral deposits dissolve.
- Discard the cleaning mixture and rinse with clean water.
- Wipe the Warming Chamber dry with cloth or allow to air dry.
NOTE: DO NOT USE BLEACH, HARSH ABRASIVES OR SOLVENTS TO CLEAN THE WARMING CHAMBER OR HEATING ELEMENTS AS THEY MAY CAUSE PERMANENT DAMAGE AND WILL VOID THE WARRANTY.
LIMITED PRODUCT WARRANTY
Dr. Brown’s Natural Flow® Insta-Feed™ Bottle Warmer includes a one-year
warranty against defects in material and workmanship from date of purchase. In
the unlikely event of a malfunction or defect during the warranty period,
please contact Handi-Craft’s Customer Service. If outside of the US or Canada,
please contact your local distributor. You will be required to provide proof
of purchase.
This warranty does not cover a defect that has been caused by negligence,
accidents or improper use of the appliance.
CUSTOMER SERVICE
If you experience unsatisfactory operation or have questions/comments, please
call Handi-Craft’s Customer Service at
1-800-778-9001, send an email to info
@handi-craft.com, or write to Handi-Craft Company, Customer Service, 4433
Fyler Avenue, St. Louis, Missouri 63116 USA.
Our Customer Service Representative will advise you how to correct the problem
yourself or will ask you to return the product for repair or replacement. If
outside of the US or Canada, please contact your local distributor.
FCC Compliance Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation. Importer: Handi-
Craft Company
Address: 4433 Fyler Ave., St. Louis, MO 63116
Phone: 800-778-9001
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
HANDI–CRAFT COMPANY ST. LOUIS, MISSOURI 63116 USA/EE.UU.
©2023 Handi-Craft Company.
All Rights Reserved. F2
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>