Dr Brown s AC177 Bottle Sterilizer and Dryer Instruction Manual
- June 12, 2024
- Dr Brown s
Table of Contents
- AC177 Bottle Sterilizer and Dryer
- READ AND SAVE THESE INSTRUCTIONS
- **** IMPORTANT SAFEGUARDS
- PREPARING FOR USE
- USING THE APPLIANCE
- CLEANING THE APPLIANCE
- DESCALING
- REPLACING THE FILTER
- WARRANTY
- CUSTOMER SERVICE
- FCC Compliance Statement
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
AC177 Bottle Sterilizer and Dryer
Instruction Manual Bottle Sterilizer and Dryer
Model Number AC177
AC177 Bottle Sterilizer and Dryer
https://qrco.de/bdZV5e
INSTRUCTIONS FOR USE
READ AND SAVE THESE INSTRUCTIONS
Package Contents:
Bottle Sterilizer and Dryer
Measuring Cup
2 Filters
Instruction Manual
Specifications:
Nominal voltage: 120 VAC, 60 Hz, 600 W
WARNING: Read the ENTIRE instruction manual before use to ensure proper
safety precautions, operation and maintenance of this product. Failure to
operate in a safe and responsible manner could result in damage to the product
or personal property and cause serious injury. A copy of these instructions is
also available online at drbrownsbaby.com/customer-
support
**** IMPORTANT SAFEGUARDS
WHEN USING ELECTRICAL APPLIANCES, PRECAUTIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK AND INJURY TO PERSONS, INCLUDING THE FOLLOWING:
- Read all instructions.
- This appliance shall not be used by children. Close supervision is necessary when any appliance is used near children. Do not attempt disassembly. The use of accessory attachments not recommended by Handi-Craft Company and may cause injuries.
- Ensure that the wall outlet voltage matches the voltage of the appliance.
- Do not operate appliance after it malfunctions or has been damaged in any manner. Return appliance to the nearest authorized service facility for examination, repair or adjustment.
- If the supply cord or plug is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified person in order to avoid hazard.
- Place appliance on a level, heat-resistant surface.
- Do not place on or near a hot gas or electric burner, or in a heated oven.
- Do not let cord hang over the edge of a table or counter, or touch hot surfaces.
- DO NOT IMMERSE IN WATER.
- HOUSEHOLD USE ONLY.
- Do not use outdoors.
- Unplug from outlet when not in use and before adding water.
- Do not spill liquid on cord or plug.
- Do not move appliance while in use or when it contains hot liquids.
- To operate, plug cord into wall outlet. To disconnect, press power button, then remove plug from wall outlet.
- DO NOT open lid or reach over the appliance while in use, as steam will cause burns and serious injuries.
- DO NOT touch hot surfaces, including lid, tray and lower rack, during or immediately after use.
- After sterilizing, wait 10 minutes for parts to cool, then open lid carefully by handle and beware of residual steam.
- DO NOT EXCEED the recommended amount of water.
- If it is necessary to drain water from the base, always POUR AWAY FROM YOU.
- As the unit switches from the sterilization to the drying cycle, it is expected to see a large initial release of steam as the fan turns on. Keep a safe distance from the unit while this cycle is in process.
- Unplug from outlet and allow to cool for 60 minutes before cleaning and descaling the unit or replacing the filter.
- Be careful to avoid spilling or splashing water on yourself when removing contents.
- The heating element surface is subject to residual heat after use.
- Keep the appliance and its cord out of reach of children.
- Do not use appliance for other than intended use.
- Appliances are not intended to be operated by means of an external timer or separate remote-control system.
- NOT FOR SPACE HEATING PURPOSES.
- This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of electric shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not modify the plug in any way.
- A short power-supply cord (or short detachable power-supply cord) is provided to reduce the risks resulting from becoming entangled in or tripping over a longer cord.
- Extension cords (or longer detachable power-supply cords) are available and may be used if care is exercised in their use.
- If an extension cord (or a long detachable power-supply cord) is used:
- The marked electrical rating of the detachable power-supply cord or extension cord should be at least as great as the electrical rating of the appliance;
- If the appliance is of the grounded type, the extension cord should be a grounding-type 3- wire cord; and
- The longer cord should be arranged so that it will not drape over the countertop or tabletop where it can be tripped over, snagged, or pulled on unintentionally (especially by children).
SAVE THESE INSTRUCTIONS
PARTS
1. Lid
2. Tray
3. Removable Handle
4. Lower Rack
5. Heating Plate| 6. Base
7. Control Panel
8. Measuring Cup
9. Filter
10. Filter Cover
---|---
PREPARING FOR USE
CAUTION: Unplug from outlet before adding water.
-
Wash items to be sterilized in hot, soapy water and rinse well.
-
Position the appliance on a level, heat-resistant surface and out of reach of children.
-
Remove the lower rack, tray and lid from the base.
-
For Automatic Sterilize/Dry or Sterilize Only functions, fill the measuring cup to the solid FILL LINE (110 mL) with WATER and pour the water ONTO THE HEATING PLATE. For Dry Only function, do not add water.
Note: For best performance, use recommended water and descale monthly. Water with minerals may shorten the life of this appliance.
CAUTION: DO NOT EXCEED the recommended amount of water. -
Place the lower rack on the base. Arrange bottles or cups upside down over prongs and add small items in remaining space. If using Dr. Brown’s® bottles, see page 3 for suggested arrangements.
-
Stack the tray on top of the lower rack and add additional small items.
Note: This appliance can sterilize any item that can withstand boiling water, such as pacifiers/soothers, teethers, toys and utensils. -
Place the lid on top of the tray. Ensure that the lid fits securely on the tray without any gaps.
-
Plug into wall outlet.
USING THE APPLIANCE
-
Press the Power Button.
Note: When the sterilizer is turned on, the appliance will beep and the indicator above the power button will light up. -
Choose the desired function:
Automatic Sterilize/Dry
A. Press the Automatic Sterilize/Dry Button. The appliance will beep one
time and the sterilization cycle will start.
Note: If there is not enough water added, incomplete sterilization may
occur. If the unit was not able to sterilize completely, it will beep and the
indicator light will flash for one hour. If this happens, wait 10 minutes to
allow unit to cool, then add water to the solid FILL LINE of the measuring cup
(110 mL), pour the water onto the heating plate and restart the sterilization
cycle.
WARNING: DO NOT open lid or reach over the appliance while in use, as
steam will cause burns and serious injuries. DO NOT touch hot surfaces,
including lid, tray and lower rack, during or immediately after use.
B. When the sterilization cycle is complete, the drying cycle will begin
automatically. The drying cycle lasts approximately 45 mins.
CAUTION: As the unit switches from the sterilization to the drying cycle,
it is expected to see a large initial release of steam as the fan turns on.
Keep a safe distance from the unit while this cycle is in process.
C. When the drying cycle is complete, the appliance will beep 5 times and
switch off automatically.
Sterilize Only
A. Press the Sterilize Only Button. The appliance will beep one time and
the sterilization cycle will start.
Note: If there is not enough water added, incomplete sterilization may
occur. If the unit was not able to sterilize completely, it will beep and the
indicator light will flash for one hour. If this happens, wait 10 minutes to
allow unit to cool, then add water to the
solid FILL LINE of the measuring cup (110 mL), pour the water onto the heating
plate and restart the sterilization cycle.
WARNING: DO NOT open lid or reach over the appliance while in use, as
steam will cause burns and serious injuries. DO NOT touch hot surfaces,
including lid, tray and lower rack, during or immediately after use.
B. When the sterilization cycle is complete, the appliance will beep 5 times
and switch off automatically.
Note: This cycle lasts approximately 9 minutes but may vary by the amount
of water you add, the number of items to be sterilized and other environmental
factors.
CAUTION: Wait 10 minutes for parts to cool, then open lid carefully by
handle and beware of residual steam.
Dry Only
A. Press the Dry Only Button. The appliance will beep one time and the drying
cycle will start.
B. When the drying cycle is complete, the appliance will beep 5 times and
swith off automatically. This cycle lasts approximately 45 minutes.
Note: Any cycle can be stopped at any time by pressing the power button.
CAUTION: If it is necessary to drain water always POUR AWAY FROM YOU, as
shown by the symbol on base.
CLEANING THE APPLIANCE
CAUTION: Unplug from outlet and allow to cool for 60 minutes before
cleaning. DO NOT IMMERSE IN WATER.
Clean at least once a week when in regular use.
BASE AND HEATING PLATE: Wipe all surfaces with a damp cloth or sponge.
TRAY, LID, LOWER RACK AND MEASURING CUP: Clean in hot, soapy water and rinse
well, or in a dishwasher (top rack only). Allow to air dry.
Note: DO NOT use scouring pads, abrasives, bleach or solvents for
cleaning.
DO NOT disassemble base. There are no serviceable parts inside.
DESCALING
CAUTION: Unplug from outlet and allow to cool for 60 minutes before
descaling.
Mineral deposits, like limescale, may form on the metal heating element in the
base. As the mineral deposits build, it can slow or disrupt the sterilization
cycle. Depending on the water type in your area, mineral deposits may vary in
appearance but the harder the water, the quicker it builds up.
Mineral deposits are not known to be harmful, but they may impair the function
of appliances or damage components. Using distilled water can help prevent
buildup, but regular descaling is needed for best performance. To remove the
mineral deposits, follow the steps below.
- Remove the lower rack, tray and lid from the base.
- Descale utilizing a mixture of vinegar/water:
A. Fill measuring cup to the dashed line (80 mL) with white vinegar.
B. Add an additional 30 mL of water to reach the solid FILL LINE of the measuring cup (110 mL total).
C. Pour the mixture ONTO THE HEATING PLATE.
D. Reassemble empty unit.
E. Plug into wall outlet, press the Power Button and run a Sterilize Only cycle.
F. Empty any remaining solution and rinse with clean water.
Note: Do not use bleach, harsh abrasives or solvents to clean the heating plate, as they may cause permanent damage and may void the warranty.
REPLACING THE FILTER
CAUTION: Unplug from outlet and allow to cool for 60 minutes before
replacing filter.
Replace the filter every six months of regular use for optimal performance.
Follow the steps below:
- The filter is located at the bottom of the base. Gently squeeze the latches on the filter cover to remove it.
- Remove and replace the filter, ensuring the pull tab is still visible on top of the filter.
- Snap the filter cover back into position.
Note: Filter must always be used to ensure proper performance.2 f ilters are included.
To purchase replacement filters: drbrownsbaby.com
WARRANTY
This appliance is warranted against defective material or workmanship for a
period of one year from the date of purchase. Any defective part will be
repaired or replaced at no charge if it has not been tampered with and
appliance has been used according to these printed instructions. This warranty
gives you specific legal rights as well as other rights which vary from state
to state.
This warranty does not cover a defect that has been caused by negligence,
accidents or improper use of the appliance. To keep your Dr. Brown’s™ Bottle
Sterilizer and Dryer in good condition and retain your warranty, USE ONLY AS
DIRECTED.
CUSTOMER SERVICE
If you experience unsatisfactory operation or have any questions/comments,
call Handi-Craft’s Customer Service at
1-800-778-9001 or send an email to
info@handi-craft.com.
For purchases made outside the United States and Canada, please contact your
local distributor.
FCC Compliance Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Importer: Handi-Craft Company
Address: 4433 Fyler Ave., St. Louis, MO 63116
Phone: 800-778-9001
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
WARNING! Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
HANDI–CRAFT COMPANY
ST. LOUIS, MISSOURI 63116 USA/EE.UU.
©2023 Handi-Craft Company.
All Rights Reserved.
References
- Topic Related Searching at CRAFT.COM.
- The #1 Pediatrician Recommended Baby Bottle | Dr. Brown's Baby
- Customer Support Archive | Dr. Brown's Baby
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>