Danfoss KE04109 Valve Drive Amplifier User Guide

May 15, 2024
Danfoss

Danfoss KE04109 Valve Drive Amplifier User Guide
Danfoss KE04109 Valve Drive Amplifier

The device is a current amplifier powered by 24-Vdc. The input is variable from 4–20 mA and the output drives an Electrical Displacement Control (EDC) valve with a single coil in a single direction at 0–100 mA. The printed wiring board is mounted in an aluminum housing with 2 MS connectors.

DIMENSIONS

DIMENSIONS
Dimensions of the KE04109 in Millimeters (Inches).

OUTPUT CHARACTERISTICS

SUPPLY VOLTAGE
24 Vdc
INPUT IMPEDANCE
240 ohm
START CURRENT
4 mA nominal (1 Volt)
FULL STROKE CURRENT
20 mA (4.8 Volt)
OUTPUT CURRENT
100 mA into a 25 ohm load

% MAXIMUM OUTPUT VOLTAGESUPPLY VOLTAGE
% SUPPLY VOLTAGE

CONNECTION DIAGRAM

CONNECTION DIAGRAM

TERMINAL CONNECTIONS

6 CONDUCTOR PINS (GC-379-2-14S-6-P)
A = +24 Volts
B = Ground
D = 4 to 20 mA positive
F = 4 to 20 mA low (ground)
6 CONDUCTOR PINS (GC-379-2-14S-6-S)
D = Valve position
F = Valve low (ground)
Note: Connection will depend on pump direction of rotation and desired port used.

CONNECTORS

6 CONDUCTOR PINS (GC-379-2-14S-6-P)
Mating connector MS3106F14S-6S
6 CONDUCTOR PINS
(GC-379-2-14S-6-S)
Mating connector MS3106F14S-6P

  • Not supplied by Danfoss Company.
    Contact: Glenair Inc. Phone: 818-247-6000

3500 Annapolis Lane North, Minneapolis, MN 55447
Telephone: 763-509-2084