VJ25PHAT Air Conditioner
Product Information
Specifications:
-
Model: RAK-VJ25PHAT, RAK-VJ35PHAT
-
Refrigerant: R410A, R32
-
Power Supply: Direct connected power supply cables to the
outdoor unit -
Mounting: Stable, non-vibratory location with full support
-
Drainage: Ensure smooth flow of water when installing the drain
hose -
Piping: Insulated indoor piping
Product Usage Instructions:
Installation Procedures:
Carefully read through the proper installation procedures before
starting any installation work. The sales agent should inform
customers about the correct operation of the installation
process.
Mounting Site:
Ensure the unit is mounted at a stable, non-vibratory location
that can provide full support. Seal any gaps with putty to prevent
air leakage.
Safety Precautions:
Read and follow all safety precautions before operating the
unit. Incorrect installation methods may cause serious
consequences. Make sure to connect the earth line for safety.
Direction of Piping:
Follow the proper direction for piping as indicated in the
manual. Use insulation sheets and binding bands as necessary.
Drainage Instructions:
Ensure proper drainage of the water container inside the indoor
unit. Fix the hanger horizontally or slightly tilted towards the
side of the drain hose to prevent water overflow.
Remote Controller Installation:
Install the remote controller holder on the wall or beam. Make
sure the unit can receive signals from the controller for proper
operation.
FAQ (Frequently Asked Questions):
Q: What type of refrigerant does the unit use?
A: The unit uses R410A and R32 refrigerants.
Q: How should I ensure proper drainage during
installation?
A: Ensure smooth water flow when installing the drain hose and
fix the hanger horizontally or slightly tilted towards the side of
the drain hose.
600
RAK-VJ25PHAT RAK-VJ35PHAT
Carefully read through the procedures of proper installation before starting
installation work. The sales agent should inform customers regarding the
correct operation of installation.
EE0019948P rev.
WARNING
Please request your sales agent or qualified technician to install your unit.
Water leakage, short circuit or fire may occur if you do the installation work
yourself. Please observe the installation stated in the installation manual
during the process of installation. Improper installation may causewater
leakage, electric shock and fire. Make sure that the units are mounted at
locations which are able to provide full support to the weight of the units.
If not, the units may collapse and impose danger. Observe the rules and
regulations of the electrical installation and the methods described in the
installation manual when dealing with the electrical work. Use cables which
are approved official in your country. Be sure to use the specified circuit. A
short circuit andfire may occur due to the use of low quality wire or improper
work. Be sure to use the specified cables for connecting the indoor and
outdoor units. Please ensure that the connections are tight after
theconductors of the wire are inserted into the terminals to prevent the
external force is being applied to the connection section of theterminal base.
Improper insertion and loose contact may cause over-heating and fire. Please
use the specified components for installation work. Otherwise, the unit may
collapse or water leakage, electric shock, fire orstronger vibration may
occur. Be sure to use the specified piping set for R32. Otherwise, this may
result in broken copper pipes or faults. When installing or transferring an
air conditioner to another location, make sure that air other than the
specified refrigerant( R32)does not enter the refrigeration cycle. If other
air should enter, the pressure level of the refrigeration cycle may increase
abnormally which could result in a rupture and injury. Be sure to ventilate
fully if a refrigerant gas leak while at work. If the refrigerant gas comes
into contact with fire, a poisonous gas mayoccur. After completion of
installation work, check to make sure that there is no refrigeration gas
leakage. If the refrigerant gas leaks into theroom, coming into contact with
fire in the fan-driven heater, space heater, etc., a poisonous gas may occur.
Unauthorized modifications to the air conditioner may be dangerous. If a
breakdown occurs please call a qualified air conditionertechnician or
electrician. Improper repairs may result in water leakage, electric shock and
fire, etc. Be sure to connect the earth line from the power supply wire to the
outdoor unit and betweenthe outdoor and indoor unit. Do not connect the earth
line to the gas tube, water pipe, lighting rod or the earth line of
thetelephone unit. Improper earthing may cause electric shocks.
R410A R32)
CAUTION
Acircuit breaker must be installed in the house distribution box for the
direct connected power supply cables to theoutdoor unit. In case of
otherinstallations a main switch with a contact gap or more than 3mm has to be
installed.Without a circuit breaker, the danger of electric shock exists.
Do not install the unit near a location where there is flammable gas. The
outdoor unit may catch fireif flammable gas leaks around it.
Please ensure smooth flow of water when installing the drain hose. Improper
installing may wet your furniture.
An IEC approved power cord should be used. Power cord type: NYM. No nearby
heat source and no obstruction near the air outlet is allowed. The clearance
distances from top, right and left are specified in figure below. The location
must be convenient for water drainage and pipe connection with the Outdoor
unit. No nearby leakage risk of flammable gas, and no nearby source of vapor
or oil smoke. To avoid interference from noise, please place the unit and its
remote controller at least 1m from the radio and television. To avoid any
error in signal transmission from the remote controller, please put the
controller far away from high- frequency machines and high-powerwireless
systems. The installation height should be at least 2300 mm or more from the
floor. The distance from the air outlet to the fire alarm must be at least
1500mm and there must be no fire alarm in the front direction of the indoor
unit.
THE CHOICE OF MOUNTING SITE
(Please note the following matters and obtain permission from customer before
installation.)
WARNING
The unit should be mounted at stable, non-vibratory location which can provide
full support to the unit.
When finishing the refrigerant collection (pumping down), stop the compressor
and then remove the coolant pipe.If you remove the refrigerant pipe while the
compressor is operating and the service valve is released, air is sucked and
apressure in the freezing cycle system will build up steeply, causing an
explosion or injury. When installing the unit, be sure to install the
refrigerant pipe before starting the compressor. If the refrigerant pipe is
not installed and the compressor is operated with the service valve released,
air is sucked and the pressure level of the refrigeration cycle may increase
abnormally which could result in a rupture and injury.
The electric cables should neither be reworked nor added.Make sure to use an
exclusive circuit breaker. Otherwise fire or electric shock might occur by
connection failure, isolation failure or over current. Make sure to connect
cables to terminal properly and terminal cover should close firmly. Otherwise,
over heating at terminal contact, fire or electric shock might occur. Make
sure that there is no dust on any connected points of electric cables and fix
firmly. Otherwise, fire or electric shock might occur.
Be sure to completely seal any gap with putty.
Figure showing the Installation of Indoor Unit.
Names of Indoor Components
above 50mm above 1 50mm
2
No.
Item
Hanger
Qty
1
1
about 300mm must not bend
about 450mm
6 4
Screw for Hanger
above 50mm
2
5
2300 mm or more
AAA size Battery
The indoor piping should be insulated
3
2
with the enclosed
insulation pipe. (If the
insulator is insufficient, please use commercial
Remote Controller 4
1
products.)
Screw for Remote
5 Controller Holder
2
SAFETY PRECAUTION
Read the safety precautions carefully before operating the unit. The contents
of this section are vital to ensure safety. Please pay special attention to
the following sign.
WARNING……….Incorrect methods of installation may cause death or serious
injury.
CAUTION……….Improper installation may result in serious consequence.
Make sure to connect earth line.
This sign in the figures indicates prohibition. Be sure that the unit operates
in proper condition after installation. Explain to customer the proper
operation and maintenance of the unit as described in the user’ s guide. Ask a
customer to keep this installation manual together with the instruction
manual.
Direction of Piping
Plug
+RUL]RQWDOO piping
Insulation sheet 6
1
5
10
from left
7 Binding band
2
Air purifying filter
8 Connection
2
3
There are directions allowed,namely,backward
9 C-case
2
pipingIURPULJKW,
horizontally pipingIURP
Remote Controller Holder
ULJKWhorizontally pipingIURP left,vertically down fromULJKW
10
1
1 Installation of Hanger , Wall Penetration and Installation of Protection Pipe
2 Installation Of The Indoor Unit
CAUTION
The draining of the water container inside the Indoor unit can be done from
the left. Therefore the hanger must be fixed horizontally or slightly tilted
towards the side of
Installation Of Remote Controller
The remote controller can be placed in its holder which is fixed on wall or
beam. To operate the remote controller at its holder, please ensure that the
drain hose. Otherwise, condensed water may overflow the water container.
unit can receive signal transmitted from the controller at the place where
Cutting Low Cover bush
While installing the pipe from the right, left or bottom side, use a knife to
cut openings as shown in figure. Then smoothen the edges of openings with a
file.
280mm 42.5mm 115mm
45mm 184mm 59mm
42.5mm
Direct Mounting On The Wall
Please use hidden beams in the wall to hold the hanger.
450mm
445mm
220mm
15mm
123mm
123mm
22mm
32.5mm
440mm
534mm 780mm
65mm 80mm
the holder is to be fixed.The unit will beep when signal is received from
the remote controller .The signal transmission is weaken by the fluorescent
light. Therefore, during the installation of the remote control holder, please
switch on the light,even during day time,to determine the mounting location
of the holder.
The remote controller
RCeomntoroteller
must be slide in the remote controller
holder, in the direction
as shown in the figure,
RCHeoomnldteororteller
until it hooks at the lower end of the remote controller holder.
Screw (2 pieces)
Openings
Openings
1 PIPING FROM THE RIGHT SIDE
(BACKWARD, DOWNWARD, HORIZONTAL)
Preparation
Connect connecting cord. Pull out the pipe, connecting
Screw the hanger at the
Wall Penetration and Installation of Protection Pipe cord and drain hose.
positions possibly near the upper and lower hooks where the indoor unit is hung. Use 4 or more screws to fix the hanger.
Procedures of Installation and Precautions
Procedures to fix the hanger.
1. Drill holes on wall. 2. Push plug into the holes. 3. Fix the hanger on wall
(As shown below) (As shown below)
with 4.1 x 32 screw.
Wall
1 Hanger 2 Screw
Plug (Procure
(As shown in figure below) Ceiling
locally)
ø4.8mm
32mm
Wall
Drill a ø65mm hole on wall which is Indoor
Outdoor
slightly tilted towards the outdoor side.
Drill the wall at a small angle.
Cut the protection pipe according to the Seal with
wall thickness.
putty
2-5mm
Seal with putty
Empty gap in the sleeve of protection
pipe should be completely sealed with
putty to avoid dripping of rain water into
the room. Please ensure smooth flow of water when installing the drain hose. Improper installing may wet your funiture. An IEC approved power cord should be
Protection pipe
WALL Sleeve of protection pipe
used. Power cord type: NYM.
Installation
Connecting cords, pipe and drain hose must be laid together with Vinyl tape.
Insert the pipe through the wall hole. 1 The upper part of the Indoor unit
Wall hole
is hanged on the hanger.
Pipe
2 The projection at the lower part Cable
Drain hose
of the Indoor unit is hooked onto the hanger.
Drain layout of backward piping
1 Hanger
1 1 Hanger
Procedures to fix the holder of remote control. 1. Drill holes on wall.(As shown below) 2. Push plug into the holes. (As shown below)
Wall
ø4.4mm
10 Remote
20mm
Control Holder
5 Screw Plug (Procure locally)
WARNING
Be sure that the wire is not in contact with any metal in the wall. Please use
the protection pipe as wire passing through the hollow part of the wall so as
to prevent the possibility of damaged by mouse. Unless it seals completely,
any air with high humidity flows from outdoor and any dew may drop.
Lift the body
Refrigerating of the unit
Pipe
upwards and
then force it
downwards.
Protection
Pipe
Drain Hose Connecting Cord
2
Projection
2 PIPING FROM THE LEFT SIDE (HORIZONTAL)
Preparation
Changed of Drain Hose and Installation Procedures. Exchange the location of
drain hose and drain cap while installing the pipe from the left side as shown
in below. Be sure to plug in the drain hose until the insulating material
folds upon itself.
Please use pliers to pull out the drain cap. (This is an easier way to remove the drain cap).
CAUTION
Insufficient insert may result in water leakage.
INSTALLATION OF REFRIGERATING PIPES AND AIR REMOVAL
1 Preparation of Pipe
Use a pipe cutter to cut the copper pipe and remove burr. Trimming tool
Please be careful when bending the copper pipe. Screw in manually while adjusting the center. After that, use a torque wrench to tighten the connection.
Flare nut
Drain hole
Copper pipe
Hexagonal wrench key (4mm) Drain hole
Drain cap
Drain Hose
· Remove low cover
· Push the pipe deeply until the insulating
section of the drain hose end gets over the rib at the indoor unit side.
· Insert drain cap up to the location securely till the cap stops.
Hexagonal wrench key (4mm)
·
Please use hexagonal wrench key(4mm) to insert the drain cap. (This is an easier way to install the drain cap.)
CAUTION
The rubber strap used for fixing the insulator should not be tied with great
force.Otherwise,this will damage heat insulation and causes water
condensation.
Please pull the lower part of the Indoor unit outwards to check if the unit is
hooked onto the hanger. Improper installation may cause vibration and noise.
Transform the piping while holding down the lower portion of pipe-support by
hand.
Pipe Rubber strap tied with great force
Pipe support
Transform after bending downward.
INSTALLATION AFTER CONNECTION OF REFRIGERATING PIPES
The refrigerating pipe should be adjusted to fit into
the hole on the wall and then ready for further
Drain hose
connection.
The terminals of 2 connected pipes must be covered
with insulator used for terminal connection. Then the pipes are wrapped with insulation pipe.
Pipe
Connecting cord
Connect the connecting cord after removing low
cover.
(Refer to “CONNECTION OF POWER CORD”) After adjustment, fit the connecting cord and pipes into the space available under the unit. Use holder to
7 Binding band Binding band can be installed to whichever
hold them tight. Be sure to cut the extra binding band. (Otherwise, it may result in abnormal noise
or
dewfall.)
side of the installation points. However, it is recommended to attach it on the right side
Insulation pipe (must be wrapped with vinyl tape at every 120 mm)
viewing from the rear.
THE CONNECTION OF REFRIGERATING PIPE DURING
THE INSTALLATION OF INDOOR UNIT
Preparation To Install Refrigerating Pipes The refrigerating pipes and
connecting cord transform and are attached.
The end of the refrigerating pipes are at locations marked with ” ” symbol. 5H I H U W R L Q V W D O O D W L R Q K D Q J H U GUD Z L Q J
Installation
Please bend ata small radius to form an arc
1100 mm
below 5mm
Hang the indoor unit onto the hanger. Use the temporary stand
at the back of the Indoor unit to push its lower part 15cm
forwards.
Projection
Place the drain hose through the hole on the wall.
Hook
Wrap the refrigerating pipes with insulation pipe after
connecting refrigerating pipe.
Connect the connecting cord after removing low cover.
(Refer to “Connection of Power Cord”)
After adjustment, the connecting cord and refrigerating pipes are placed into the space available under the Indoor unit.
about 15cm
The projection of Indoor unit must hook to the hanger.
Wall hole
Pipe
Cable
Drain hose
Drain layout of backward piping from left
Connecting cord
Protection
pipe
Refrigerating
Drain hose
pipe
Heat insulation pipe
Pull this to the front during
the connection of refrigerating
pipe to ease task.
Connecting cord
Connected section
3 Heat Insulation and Finish of the Piping
The connected terminals should be completed sealed with heat insulator and then tied up with rubber strap. Do not tie the terminals with the tape too tight. If any clearance or over-tightening may cause condensation. Please tie the pipe and power line together with vinyl tape as shown in the figure showing the installation of Indoor and Outdoor units. To enhance the heat insulation and to prevent water condensation, please cover the outdoor part of the drain hose and pipe with insulation pipe. Completely seal any gap with putty.
Insulation material for pipe connection
Sleeve of protection pipe
Putty
Putty
4 Installation of Drain Hose
CAUTION
Remove burr and jagged edge will cause leakage. Point the side to be trimmed
downwards during trimming to prevent copper chips from entering the pipe.
Wrench
Torque wrench
Before flaring, please put on the flare nut.
Die
Die
Please use
A exclusive tool for
refrigerant R410A,
Copper pipe R32.
Outer
Diameter (Ø) 635 (1/4″) 952 (3/8″)
A (mm) Rigid Flaring Tool
For R410A,R32 tool 0 – 05
0 – 05
For R22 tool
10 10
Small diameter side
Outer diameter of pipe (ø)
Torque N·m (kgf·cm)
6.35 (1/4″) 13.7-18.6 (140 – 190)
Large diameter side
9.52 (3/8″) 34.3-44.1 (350 – 450)
Valve head cap
Small diameter side Large diameter side
Valve core cap
6.35 (1/4″) 9.52 (3/8″)
19.6-24.5 (200 – 250) 19.6-24.5 (200 – 250) 12.3-15.7 (125 – 160)
Gas leakage inspection
2 Pipe Connection
CAUTION
In case of removing flare nut of a indoor unit, first remove a nut of small
diameter side, or a seal cap of big diameter side will fly out. Free from
water into the piping when working. Be sure to tighten the flare nut to the
specified torque with a torque wrench. If the flare nut is overtightened, the
nut may be split after a long period has passed, and may cause a refrigerant
leak.
Please use gas leakage detector to check if leakage occurs at connection of Flare nut as shown in below. If gas leakage occurs, further tighten the connection to stop leakage.
CONNECTION OF POWER CORD
WARNING THIS APPLIANCE MUST BE EARTHED.
Detail of Cutting the Connecting Cord
Indoor Unit
Strip wires
70mm
10mm 1 2 3
Green + Yellow (ground)
10mm 45mm
Connecting cord
WARNING
Leave some space in the connecting cord for maintenance purpose and be sure to
secure it with the cord band. Secure the connecting cord along the coated part
of the wire using the cord band. Do not exert pressure on the wire as this may
cause overheating or fire.
Wiring of The Indoor Unit
For wire connection of the Indoor unit, you need to remove the front cover,
the low cover under the body of the unit and terminal cover. Remove the cover
from the terminal base and screw the cable.
Method to remove the low cover
Pull at the 1 and 2 in
the directions as shown
by arrows to remove the
2
cover.
1
How to connect the optional parts
(H-LINK RAC Adapter, Dry contact, Wired Remote
Controller, Run status and alarm output)
For cable connection to control P.W.B., you need to remove front cover and
electrical box cover. Each connecting location is as below. 1 Dry contact: CN6
2 H-LINK RAC Adapter: CN7B 3 Wired Remote Controller : CN20 4 Relay kit for
run status and alarm output: CN25 Please check and confirm manuals attached to
each optional parts for more connection details. Please check service manual
about how to set from remote controller. You can refer to this installation
manual how to remove and re-attach the front cover. Please be careful not to
damage lead wires by edge of plate when connecting the optional parts. Please
do the operation test after the connection.
Earth
After remove the screw and terminal cover, and put the connecting cords and
fix the terminal cover with screw.
Connecting cord Cord band
CN20 CN7B CN6 CN25
HOW TO REMOVE OR ATTACH THE FRONT COVER
How to remove the front cover
Remove the front panel
Move
2
Arm
1
Push
ECO Sensor
Claw
Claw
Claw cover Screw
Screw
Ditch
Bending upwards
Condensed water pond
Condensed water pond
CAUTION
Be sure that the drain hose is not loosely connected bend or proper condition
like left figure.
CAUTION
You are free to choose the side (left or right) for the installation of drain hose. Please ensure the smooth flow of condensed water of the Indoor unit during installation. (Careless may result in water leakage.)
HOW TO REMOVE INDOOR UNIT
Push up the [PUSH] sections at the bottom of the indoor unit and pull the
bottom plate towards you. Then the claws are released from the stationary
plate.
(The [PUSH] sections are indicated by 2 arrows in the right figure)
[PUSH] mark positions
1 Push the end of the right-side arm outward to release the tab. 2 Move the
left-side arm outward to release the left tab, and
then pull the panel towards you. Remove the filters. After removing 1 screw,
remove the cover of electric box, then remove the 2 screws, pull the center of
the front cover towards you and release the claws. Pull the side faces (lower
sections) of the front cover towards you as shown in the figure and remove the
cover.
Claw
How to Attach the Front Cover
After installing the front cover onto the unit, hook three claws at upper side
of the cover securely. Then, push the center of the front cover to lock the
claws. Tighten the 2 screws.
Assemble the cover of electric box, then tighten the screw.
Install the filter.
Attaching the Front Panel Insert the shaft of the left arm along the step on
the unit into the hole. Securely insert the shaft of the right arm along the
step on the unit into the hole. Make sure that the front panel is securely
attached, and then close the front panel.
CAUTION
Remove and attach the front cover to the X
direction as shown in the figure to ensure
no damage occurs to the ECO sensor.
O