These devices have been designed to be in compliance with the standards currently in effect: EN/IEC 60947-5-1, EN/ISO 13849-1, EN/IEC 62061, EN/IEC 60947-1, EN/ISO 14119, EN/IEC 60204. These devices can achieve up to category 4 PL=e or SIL 3 (if combined with an appropriate Control Safety Unit PL=e / SIL 3).

HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH

Before servicing this device:

  • Disconnect all power before servicing equipment.
  • Place a “DO NOT TURN ON” label on all power disconnects.
  • Lock all power disconnects in the open position.
  • Install and close all covers before applying power or using this device.

Failure to follow these instructions will result in death or serious injury.

Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel

Schneider Electric XCSLE XCSLF Safety Switch 2

  1. Tapped entries for cable gland 1/2” NPT / ISO M20X1,5
  2. Shim provided with XCSZ01 enabling an XCKJ or XCSL5/7 with a ZCKY07 key to be replaced by an XCSLF with an XCSZ01 key without redrilling any mounting holesSchneider Electric XCSLE XCSLF Safety Switch 4

WARNING

LOSS OF SAFETY FUNCTIONALITY

  • All spare actuating keys must be stored in a safe place.
  • Do not use a master key, modified or dummy actuating key.
  • Actuating keys must be permanently mounted by soldering, riveting or non-retractable screws.
  • Perform a periodic inspection and verify:
    • secure mounting of components, including the head
    • mechanical adjustment of XCSLE/LF switch with the XCSZ0* actuating key
    •  proper operation of the head and proper switching function
    •  correct sealing of cable entry
    •  wear: devices should not be used beyond the characteristics stated in catalogue
    • do not modify the devices.
  •  The switch must be protected from environemental shocks.

Failure to follow these instructions can result in death, serious injury, or equipment damage.

Wiring diagram

Schneider Electric XCSLE XCSLF Safety Switch 5

M23 19-pin connectors

Schneider Electric XCSLE XCSLF Safety Switch 6

Examples
XCSLp with 2-LED module associated with the XPSUAF

Schneider Electric XCSLE XCSLF Safety Switch 7

Key inserted and locked : GN (green) LED on / Key not inserted : OG (orange) LED on

Head orientation

Schneider Electric XCSLE XCSLF Safety Switch 8

WARNING

IMPROPER INSTALLATION

  • Do not use the safety limit switch as stopper or as centering device for moving guard.
  • Use physical stop designed for that purpose.

Failure to follow these instructions can result in death, serious injury, or equipment damage.

Adjustment of actuating keys

Schneider Electric XCSLE XCSLF Safety Switch 9

Tightening torque, tightening capacity

Note: Connection support is made through a 1/2″ NPT and M20 fitting. If using metal conduit, use flexible metal conduit only. Maximum conduit tightening torque is: 23 Nm (17 Ft-lb) for XCSLE, 90 Nm (66 Ft-lb) for XCSLF.

Schneider Electric XCSLE XCSLF Safety Switch 10

Contact status

Schneider Electric XCSLE XCSLF Safety Switch 11 WARNING

IMPROPER COVER CLOSING

  • Close and screw cover following tightening torque values.
  • Lock with manual locking key.
  • Remove manual locking key and store it in a safe place.

Failure to follow these instructions can result in death, serious injury, or equipment damage.

Servicing procedures

Schneider Electric XCSLE XCSLF Safety Switch 12

Maintenance
It is imperative to check the following points regularly

  • the mechanical adjustment of product XCSLE / LF with the XCSZ 01/02/03/05 tongued key
  • wear: the devices should not be used beyond the characteristics stated in catalogues
  • make sure of the good electric switching
  • it is forbidden to modify the devices.

Any and all liability shall be excluded in case of non compliance with the requirements of this notice.

Characteristics

Schneider Electric XCSLE XCSLF Safety Switch 14

OPERATION

Operation example of a safety switch XCSLE/LF: Locking when the solenoid is unpowered (Locking on de-energisation models) or locking when the solenoid is powered (Locking on energisation models

Schneider Electric XCSLE XCSLF Safety Switch 13

Differences when unlocked with power disconnected

Documents / Resources

| Schneider Electric XCSLE XCSLF Safety Switch [pdf] Instruction Manual
XCSLE XCSLF Safety Switch, XCSLE XCSLF, Safety Switch, Switch
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Schneider Electric User Manuals

Related Manuals