THREE OPERATING MODES (ALTERNATIVE)

Stand alone| |
---|---|---

Depending on the mode you select, you will need

Stand alone| |
---|---|---
Nothing else| Gateway| Hub Smart Home
for management via smartphone/tablet art. 30807.x-20597-19597-16497-14597| Hub Smart Home
Amazon Alexa, Google Assistant, Siri and Homekit voice assistants for possible voice operation| Hub Samsung SmartThings Amazon Echo Plus, Eco Show, Echo Studio

FRONT VIEW

VIMAR 02973.B Smart Home View Wireless - FRONT VIEWN.B. Graphic representation of the Linea series. Position of terminals, wiring and functions also identical for 02973.

|  Degrees Celsius/Fahrenheit selection, Configuration and Reset
---|---
| Display brightness and RGB LED in standby setting
A| Display
B| Set point adjustment dial
C| Illuminated ring for status signalling
| Power on and off
| Heating or air conditioning mode selection

The Apple, iPhone and iPad logos are trademarks of Apple Inc., registered in the United States and in other Countries and Regions. App Store is a service trademark of Apple Inc. Google is a trademark of Google LLC. Amazon, Alexa and all related logos are trademarks of Amazon.com, Inc. or its affiliates

CONNECTIONS: CIRCULATION PUMPS, BURNERS, SOLENOID VALVES AND TEMPERATURE PROBEVIMAR 02973.B Smart Home View Wireless -
CONNECTIONS

FEATURES

Rated supply voltage 100-240 V~, 50/60 Hz
RF transmission power < 100mW (20dBm)
Frequency range 2400-2483.5 MHz

Setpoint between 4°C and 40°C
ErP classification (EU Reg. 811/2013): – ON/OFF: class I, contribution 1%. – PID: class IV, contribution 2%.
Type of action| 1BU
Degree of pollution| 2
Rated pulse voltage| 4000 V
Software class| A
2 (L, N) for line and neutral
2 for external temperature probe (art. 02965.1 and 20432-19432-14432)
Maximum length of the external sensor connection cable| 10 m
Minimum cross sectional area of twisted cable to use for inputs| 0.5 mm2
2 C-NO relay

The View Wireless App can also be used to associate a magnetic or wired contact of art. 03980 to turn off the temperature control system in the event of an open window; in this case, the time for reaction and reactivation of contact opening and closing can be set:

  • Reaction time: between 0 minutes (instantaneous) and 30 minutes; default = 0 minutes
  • Reactivation time (time after which the thermostat is reactivated even without closing the window): between 0 (disabled) and 12 hours; default = 1 hour.

USE

The front buttons, the display, the dial and the lighting of the circular ring around the display can be used to set and display all the operating modes of the thermostat.
Use the dial to set a new setpoint. In particular, for operation in Bluetooth technology:
– in automatic operating mode, turn the dial for the thermostat to switch to manual operation for a period of time which can be set on the View App;
– in manual operation or reduction mode, the thermostat remains in this mode and the setpoint is that set on the dial.

INSTALLATION RULES

The C-NO contact of the relay must be protected against overloads by installing a device, fuse or automatic 1-way switch, with a rated current not exceeding 10 A. • Do not connect a SELV circuit to the C-NO terminals as there is no double insulation on the L-N terminals. • The device must be installed in a flush mounting box or surface mounting box with the related mounting frames and cover plates, at a height of 1.5 m above floor level, in a suitable position for the correct detection of the room temperature, avoiding installation in recesses, behind doors and curtains, areas affected by heat sources or subject to the flow of forced heating/cooling ventilation sources or affected by atmospheric factors. Avoid in particular installation on perimeter walls or in association with devices which generate heat (e.g. dimmers or lamps).
REACH (EU) Regulation no. 1907/2006 – Art.33. The product may contain traces of lead

DEVICE DETAILS, CONFIGURATION AND WEEE INFORMATION CAN BE DOWNLOADED IN PDF FORMAT FROM THE PRODUCT DATA SHEET ON www.vimar.com (the QR code opens the data sheet of art. 30810.B, which shares the same instructions sheet as art. 30810.x-02973).

https://www.vimar.com/en/int/catalog/product/index/code/30810.B
****49401702A0 04 2309
www.vimar.com
Viale Vicenza, 14
36063 Marostica VI – Italy

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals