BRAYER BR4883 Convector Heater Instruction Manual
- June 4, 2024
- BRAYER
Table of Contents
BRAYER BR4883 Convector Heater
CONVECTION HEATER BR4883
Convection fan heater is intended for the use as an additional heating unit, for heating of a small amenity room or its certain area.
DESCRIPTION
- Hot air outlet
- Carrying handle
- Light indicator
- Operation mode switch
- Thermostat control knob
- Floor supports (2 pc.)
Pic 1
Pic 2
ATTENTION!
- Portable convection fan heaters are intended for the use as a supplementary source of heat, for heating a small amenity room or its certain area. They are not intended for the use as main heating units.
- For additional protection it is reasonable to install a residual current device (RCD) with nominal operation current not exceeding 30 mA. To install an RCD, contact an electrical technician.
SAFETY MEASURES AND OPERATION RECOMMENDATIONS
Read the operation manual carefully before using the convection fan heater; after reading this manual, keep it for future reference.
- Use the unit for its intended purpose only, as it is stated in this manual.
- Mishandling the unit can lead to its breakage and cause harm to the user or damage to the user’s property, which is not covered by warranty.
- Make sure that the operating voltage of the unit indicated on the label corresponds to your home mains voltage.
- The three-wire power cord of the convection fan heater has a ground wire, and the power plug has a ground contact. Always connect the power plug to the socket with reliable grounding contact. In case of any inner short circuit, grounding reduces the risk of electric shock, because the current will pass through the ground wire.
- To avoid fire, do not use adapters for connecting the unit to the mains.
- To avoid mains overloading, do not switch on several electrical appliances with high power consumption at the same time.
- If you use an extension cord, make sure that the wire cross-section of the extension cord and the wire cross-section of the power cord of the convection fan heater match.
- Place the unit vertically on an even, dry, moisture- and heat-resistant surface, do not place it horizontally and do not turn it over.
- Use only the floor supports when placing the unit on the floor.
- Do not use the unit in small rooms, if there are persons who are not able to leave the room on their own, unless they are constantly supervised.
- Do not place the convection fan heater on soft surfaces, such as carpets with deep pile, sofas or beds.
- The distance between the front grid of the convection fan heater and the furniture should be at least 1 m.
- Do not use the convection fan heater in a limited space, for example, in built-in cabinets or wall niches.
- Do not use the unit if the room temperature is above + 30ºС.
- Do not use the power cord as a carrying handle.
- Do not wind the power cord around the unit body.
- Provide that the power cord does not contact with hot surfaces and sharp furniture edges.
- Protect the unit from impacts, falling, vibrations and other mechanical stress.
- Avoid blocking of the bottom air inlet grid with foreign objects, do not cover the unit during operation.
- Do not use the unit to dry clothes or other household items.
- Do not use the unit in places where inflammable liquids are used or aerosols are sprayed, do not use the unit in the places where such liquids are stored.
- Do not use the unit outdoors.
- Do not use the unit near swimming pools or other containers filled with water.
- If the unit is dropped into water, unplug it immediately, and only then you can take the unit out of water. Apply to the authorized service center for testing or repairing the unit.
- Do not touch the unit body, the power cord and the power plug with wet hands.
- It is not recommended to use the unit during lightning storms.
- During operation the convection fan heater body heats up strongly, do not touch hot parts of the unit body to avoid burns.
- Avoid getting burns by hot air.
- Never leave the unit connected to the mains unattended.
- Unplug the unit after usage or before cleaning.
- Switch the convection fan heater off and unplug the power cord plug from the mains socket.
- When unplugging the unit, hold the power plug and carefully remove it from the mains socket, do not pull the power cord, as this can lead to its damage or cause a short circuit.
- Do not immerse the unit into water or any other liquids.
- If water droplets fall on the convection fan heater body, switch it off and disconnect the power plug from the mains before touching the unit, then wipe the unit body with a dry cloth.
- For child safety reasons do not leave polyethylene bags used as packaging unattended.
ATTENTION! Do not allow children to play with polyethylene bags or packaging film. Danger of suffocation!
-
The unit is not intended for usage by children.
-
Do not leave children unattended to prevent using the unit as a toy.
-
Do not allow children to touch the unit body, the power cord or the power plug during operation of the unit.
-
Be especially careful if children or disabled persons are near the operating unit.
-
During the unit operation and breaks between operation cycles, place the unit out of reach of children.
-
The unit is not intended for usage by physically, sensory, psychically or mentally disabled persons
(including children) or by persons lacking experience or knowledge if they are not under supervision of a person who is responsible for their safety or if they are not instructed by this person on the usage of the unit. -
From time to time check the power cord integrity.
-
If the power cord is damaged, it should be replaced by the manufacturer, a maintenance service or similar qualified personnel to avoid danger.
-
If a foreign smell appears, immediately stop using the unit, try to visually determine the cause of the foreign smell, a possible reason is a foreign object present on the heating element, if possible, remove the foreign object from the heating element, otherwise contact the service center.
-
Do not repair the unit by yourself. Do not disassemble the unit by yourself, if any malfunction is detected, and after the unit was dropped, unplug it and apply to the service center.
-
To avoid damages, transport the unit in the original package.
-
Keep the unit in a dry cool place out of reach of children and disabled persons.
THE UNIT IS INTENDED FOR HOUSEHOLD USE ONLY, DO NOT USE THE UNIT FOR COMMERCIAL OR LABORATORY PURPOSES.
BEFORE THE FIRST USE
After the unit’s transportation or storage at negative temperature, unpack it and wait for at least 3 hours before using it.
- Unpack the unit and remove all the packaging materials.
- Keep the original package.
- Read the safety measures and operating recommendations.
- Check the delivery set.
- Examine the unit for damages, in case of damage do not plug it into the mains.
- Make sure that specified specifications of power supply voltage of the unit correspond to the specifications of your mains. When using the unit in the mains with 60 Hz frequency, the unit does not need any additional settings.
- Wipe the convection fan heater body with a slightly damp cloth and then wipe it dry.
ASSEMBLING AND INSTALLATION
Stand mode
- Turn over the unit body. Match the openings on the feet (6) with the corresponding openings in the bottom part of the unit body.
- Fix the feet (6) with the screws supplied with the unit. (pic.1)
Note: you can install the convection fan heater directly on the feet (4) (pic. 1) or you can insert the wheels (5) into the feet (4).
- Turn over the unit and place it on an even steady surface.
- Fix the carrying handle (2) with 2 screws M4x16mm (pic.2).
USING THE CONVECTION FAN HEATER
- Place the convection fan heater vertically on an even dry moisture- and thermal-resistant surface, do not place it horizontally and do not turn it over.
- Do not place the convection fan heater on soft surfaces, such as carpets with high pile, sofas or beds.
- The distance between the convection fan heater and the furniture should be at least 1 m.
- To avoid mains overloading, do not switch on several electrical appliances with high power consumption at the same time.
- Insert the power plug into the mains socket, the light indicator (3) will light up.
- Set the operation mode switch (4) into the necessary position:
- «0» – the unit is off;
- – low power (1000 W);
- – maximal power (2000 W).
- Turn the thermostat control knob (5) clockwise to the maximum position. When the desired air temperature in the room is reached, turn the thermostat control knob (5) counterclockwise until a distinctive click, in this position of the thermostat the set air temperature in the room will be maintained.
- To increase the air temperature in the room, turn the thermostat knob (5) clockwise and counterclockwise to decrease it.
Note: – the fan heater will not switch on if the thermostat settings correspond to the air temperature in the room.
- After the unit operation is finished, turn the thermostat control knob (5) counterclockwise as far as it will go and set the operation mode switch (4) to the position «0» and unplug the unit.
Note: – when you switch the unit on for the first time, some smoke or foreign odor may appear. It is normal and not covered by warranty.
ANTIFREEZING FUNCTION
This function can be used in rooms with low temperatures while preventing the
water pipes from freezing.
- The convection fan heater is equipped with an anti freezing function, which switches the unit on if the room temperature drops below +5ºC.
- To use this function, plug the power cord into a mains socket and the light indicator (3) will light up, set the operation mode switch (4) to the position « » or « » and set the thermostat control knob (5) to the position «0».
- The unit will remain switched off until the room temperature drops below +5ºC, then the unit
will automatically turn on and maintain the room temperature above +5ºC.
AUTOMATIC EMERGENCY SWITCH-OFF FUNCTION IF THE OUTGOING AIR IS TOO HOT
- If the outgoing air temperature exceeds the acceptable value, the automated thermal switch will switch off the convection fan heater.
- Set the operation mode switch (4) to the position «0» and unplug the unit, let the unit cool down for approximately 15-25 minutes (the waiting time depends on the room temperature), and only then you can switch it on again.
- Make sure that the upper and bottom air grids are not blocked with foreign objects.
- Insert the power plug into the mains socket and switch the unit on.
- If the convection fan heater does not switch on, it may be caused by another malfunction. In this case apply to a service center for repairing of the unit.
PROTECTION FROM DROPPING
- If the convection fan heater accidentally falls or tilts too much, the fall protection system will switch off the unit.
- Set the convection fan heater into the vertical position, and the unit will resume operation.
Note: – place the unit on an even dry and steady surface to prevent it from dropping.
CLEANING AND MAINTENANCE
- Before cleaning the convection fan heater, set the operation mode switch (4) to the position «0», make sure that the power cord is not connected to the mains.
- Wipe the unit body with a slightly damp cloth and then wipe it dry.
- Do not use liquid detergents, abrasive cleaners and any solvents to clean the unit.
- To avoid the risk of electric shock provide that no water or other liquid gets into the unit body.
- To clean the air grids, use a vacuum cleaner with a corresponding attachment.
STORAGE
- After cleaning put the convection fan heater away for storage in a dry cool place away from children and disabled persons.
- Before using the convection fan heater next time, it is recommended to check the heater operability and integrity of the power cord and plug.
DELIVERY SET
- Convection fan heater – 1 pc.
- Feet – 2 pcs.
- Mounting kit – 1 pc.
- Working instruction – 1 pc.
TECHNICAL SPECIFICATIONS
- Power supply: 220-240 V, ~ 50-60 Hz
- Rated input power: 2000 W
- Heating area: 25 m²
- Protection degree: IP20
RECYCLING
To prevent possible damage to the environment or harm to the health of people
by uncontrolled waste disposal, after expiration of the service life of the
unit or the batteries (if included), do not discard them with usual household
waste, take the unit and the batteries to specialized stations for further
recycling.
The waste generated during the disposal of products is subject to mandatory
collection and consequent disposal in the prescribed manner.
For further information about recycling of this product apply to a local
municipal administration, a household waste disposal service or to the shop
where you purchased this product.
The manufacturer reserves the right to change the design, structure and
specifications not affecting general operation principles of the unit, without
prior notice.
The unit operating life is 3 years
The manufacturing date is specified in the serial number.
In case of any malfunctions, it is necessary to apply promptly to the
authorized service center.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>