EPH CONTROLS CP4M Room Thermostat Installation Guide

June 9, 2024
EPH CONTROLS

EPH CONTROLS CP4M Room Thermostat

Contents

  •  Factory default settings
  • Specifications
  •  Wiring diagram
  •  Mounting

Installation Instructions

EPH CONTROLS CP4M Room Thermostat -
1

Factory default settings

  • Contacts: Volt free contact
  • Program: 5/2D
  • Backlight: Auto
  • Keypad: Unlocked
  • Clock type: 24 Hr Clock
  • Daylight saving: On
  • In-built frost protection: 5˚C Not adjustable

Specifications

  • Power supply: 200 – 240 Vac, 50-60 Hz
  • Power consumption: 630 mW
  • Temp. control range: 5 … 35°C
  • Ambient temperature: 0~50°C
  • Admissible ambient humidity: 5-95 % RH
  • Dimensions: 140 x 99 x 30mm
  • Temperature sensor: NTC 100K Ohm @ 25°C
  • Temperature indication: ˚C
  • Switching differential: 0.4˚C
  • Frost protection: Only operational in OFF mode
  • Contact rating: 250 Vac 7A
  • Program memory backup: 3 months
  • Battery: 3Vdc CR2032
  • Backlight: Blue
  • IP rating: IP20
  • Backplate: British System Standard
  • Pollution degree: Pollution Degree 2
  • Rated impulse voltage: 2,500V as per EN 60730
  • Automatic action: Type 1.C
  • Software: Class A
  • Ball pressure test temperature: 70˚C

Mounting

The mounting height should be 1.5 meters above the floor level. The thermostat should be wall mounted in the room where the heating is to be controlled. The place of installation should be chosen so that the sensor can measure the room temperature as accurately as possible. Choose the mounting location to prevent direct exposure to sunlight or other heating / cooling sources when mounted. The unit can be fitted:

  • To a recessed conduit box
  • Directly wall mounted

Wiring diagram

Mounted

This thermostat can be mounted in the following ways:

  • To a recessed conduit box
  • Directly wall mounted