Pilot Light Operators
Class| Type| Application| Pilot Light| UL listed for use on a flat surface of
enclosure types:
---|---|---|---|---
Standard| Push to test| Remote test
9001| KP| Heavy Duty| | | | 1, 2, 3, 3R, 4, 6, 12 & 13
SKP| Corrosion Resistant| | | | 1, 2, 3, 3R, 4, 4X, 6, 12 & 13
Full View
The metal locking thrust
washer (C) is required to ground the 9001K operator per IEC 1131-2. Align the
tab with the slot in the panel.
– The Fingersafe™ feature is not available on 9001KTR or 9001 SKTR.
– The lens gasket (N) must be installed to retain enclosure Type 4 & 6
ratings.
**DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Disconnect all power
before servicing.
Electric shock will result in death or serious injury.
Legend
** A. operator
B. ring nut
C. locking thrust washer
D. trim washer
E. standard light module
E1. shallow depth light module
(KP, SKP)
F. compensating gaskets
G. panel
J. metal legend plate
K. plastic legend plate
L. alignment tab
M. ring nut wrench (K95)
N. lens gasket
O. lens
P. contact block (KT, SKT, KTR, SKTR)
Q. jumpers (KT, SKT, KTR, SKTR)
Mounting
Dim.: in. / pulg / po (mm)
Hole & Notch Punch
Ø 31 mm: Greenlee knockout punch 60242 Push buttons also mount in 1.20 (30.5)
hole
Min. Centerline Spacing
Without legend plate
Vertical | Horizontal |
---|---|
1.56 (40) | 2.25 (57) |
1,56 (40) | 2,25 (57) |
1,56 (40) | 2,25 (57) |
With legend plate
Consult the Digest.
Installation
- – Select the number of gaskets (F).
Panel thickness| No. of gaskets
---|---
1/16 (1,6)| 4
1/8 (3,2)| 8
3/16 (4,8)| 2
1/4 (6,4)| 1 - – Mount onto the panel (G).
- – Install the legend plate (J or K) or trim washer (D), then the locking thrust washer (C).
Legend Plate| Washer
---|---
Metal (J)| on
Plastic (K)| only
None| D and c - -Install the ring nut(B).
- – Install the lens (O).
- – Pressing the lens moves the contact from C to L1 to test the bulb (KT, SKT).
Typical Wiring Diagrams
Type
Type (see legend)
Legend
Test Button
Test
(Test Circuit)
Stop
Start
Ls
(Limit Switch)
SIG
(Signal Circuit)
CR
(Control Relay)
M
(Motor Controller)
Electrical equipment should be installed, operated, serviced, and maintained
only by qualified personnel. No responsibility is assumed by Schneider
Electric for any consequences arising out of the use of this material.
Schneider Electric USA, Inc.
800 Federal Street Andover, MA 01810 USA 1-888-7782733
www.schneiderelectric.us
Released for Manufacturing Printed on
2023/06/09
© 1997–2021 Schneider Electric
All Rights Reserved
UK Representative: Schneider Electric Limited
Stafford Park 5
Telford, TF3 3BL, UK
65013-002-51
Rev. 04, 06/2021