LOG BARN A03512 Rustic Mason Jar Lights Farmhouse Chandelier Instruction Manual

June 17, 2024
LOG BARN

LOG BARN A03512 Rustic Mason Jar Lights Farmhouse Chandelier

SAFETY INFORMATION

WARNING (To reduce the risk of fire, electric shock, or injury to persons):

  1. We suggest installation by a licensed electrician.
  2. Please read the instruction carefully and save it as you may need it at later time.
  3. Before you start, NEVER attempt any work without shutting off the electricity until the work is done. A). Go to the main fuse, or circuit breaker, box in your home. Place the main power switch in the “OFF” position. B). Place the wall switch in the “OFF” position.
  4. Mounting surface should be clean, dry, flat, strong enough and 1/4” larger than the canopy on all side. Any gaps between the mounting surface and canopy exceeding 3/16” should be corrected as required.
  5. Make sure that the ceiling or wall can stand the weight of the lamp before fixture.
  6. Make sure the voltage you are using is 120V. The maximum wattage is 40W per bulb.
  7. Keep the lamp away from acidic and basic objects in case of damaging the surface of the lamp.
  8. When replacing bulb, you should turn off or unplug the lamp and you must wait until it is cool as bulbs get hot quickly.
  9. The safety instructions appearing in this manual are not meant to cover all possible conditions that may occur. It must be understood that common sense, caution and care must be used with any electrical products.

IMAGE FOR FINISHED PRODUCT

TOOLS REQUIRED (NOT INCLUDED)

  • Ladder

  • Phillips head, flat blade screwdriver

  • Electrical tape

  • Pliers

  • Wire cutter/Stripper

PARTS TYPE & QTY INCLUDING

(A) Mounting plate assembly (1)
(B) Green ground screw (1)
(E) Canopy (1)
(F) Loop (4)
(G) Knob nut (2)
(H) Quick link (4)
(I) Chain (2)
(J) Tube (2)
(K) Threaded nipple (2)
(L) Fixture body (1)
(M) Cap (4)
(N) Jar (4)
Parts Type & Qty Including

ACCESSORIES & QTY ENCLOSED

(C) Plastic Wire Connector (3)
(D) Mounting screw (2)

ASSEMBLY & INSTALLATION INSTRUCTIONS

  1. Carefully remove the fixture from the carton and check that all parts and accessories are included as shown in the above illustration .

  2. Turn off power
    Before you start to make installation, NEVER attempt any work without shutting off the electricity until the work is done. A). Go to the main fuse, or circuit breaker, box in your home. Place the main power switch in the “OFF” position. B). Place the wall switch in the “OFF” position.

  3. Unscrew the knob nuts (G) from canopy (E) then gently remove the mounting plate assembly (A)

  4. Slip the tube (L) along wires then thread onto the nipple of the top fixture body (M)till snug ,thread another tube(L) onto the nipple of top fixture body (M)till tight.

  5. Attach the quick links(J)to connect the chains(I) and the loops(L) of the cannopy (G)and tubes (J) Carefully lace the wires through the chain (I)(every other link) and stop just before you reach the top of canopy (E).

  6. If needed, cut off the extra power cord length on the fixture 2 wires cord and green ground wire so that they all are at least 6 inches (152.4 mm) long within the outlet box.

  7. Carefully pass wires through the mounting plate assembly (A) Secure the mounting plate assembly (A) to outlet box with the outlet box screws D.

  8. Make wire connections
    Connect wires as below wires connecting shown. TAKE NOTE OF YOUR COLOR OF FIXTURE ,NEVER CONNECT FIXTURE WIRES TO GROUND WIRES
    Connect ground wire according to below chart

Twist plastic wire connector(C) until wires are tightly joined together, wrap each connector with approved electrical tape for more secure connection and carefully stuff all wires into the outlet box.
Connect wires according to below chart Connect Black or Red Supply Wire to:| Connect White Supply Wire to:
---|---
Black| Black
Parallel cord (round & smooth)| Parallel cord (square & ridged)
Clear. Brown. Gold or Black without tracer| Clear. Brown. Gold or Black with tracer
Insulated wire (other than green) with copper conductor| Insulated wire (other than green) with silver conductor

  • Note: When parallel wires (SPT I & SPT II) are used. The neutral wire is square shaped or ridged and the other wire will be round in shape or smooth (see illus.)
    Assembly & Installation Instructions

    1. Align the holes in the canopy (E) with the mounting screws, then attach the canopy (E) using the previously removed knob nuts (G). Hand tighten until snug.
      Note: The canopy (E) should be snug against the ceiling and the knob nuts. If not, adjust the length of the nipples on the mounting plate assembly (A) by unscrewing the preassembled hex nuts and then screwing the mounting screws in or out of the mounting plate until the length is achieved. Tighten the hex nuts and proceed to step 9
      Install bulb (Not included. Please do not exceed the maximum capacity recommended on the socket.) Place the jar (N) over the bulb and thread it onto the cap (M) properly.

    2. Check everything is already installed properly, then you could turn on the light. Enjoy!

CLEANING
To clean, wipe fixture with a soft cloth. Do not use abrasive materials such as scouring pads or powders, steel wool or abrasive paper.
ORDERING PARTS
Keep this sheet for future reference, and in case you need to order replacement parts. All parts for this fixture can be ordered from place of purchase. Be sure to use exact wording from illustration when ordering parts.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals