GIRA 2621 97 DCS IP Gateway User Manual
- June 17, 2024
- GIRA
Table of Contents
GIRA 2621 97 DCS IP Gateway
Device description
-
DCS-IP-gateway
The DCS-IP-gateway converts signals from the Gira door communication system to the network protocol level (IP) and thus enables the integration of net-work- capable devices such as computers, video-IP telephones and IP cameras. -
DCS Communicator
With the DCS Communicator software, common computers and PC-based operating devices such as the Gira Control 9 Client or Gira Control 19 Client can be used as home stations via the network connection. The DCS Communicator offers all the functions of a video home station such as accepting conversations, switching lights (in conjunction with a switching actuator) and opening doors. -
License models
Several license models are available for the DCS-IP-gateway. The number of licenses determines how many devices (e.g. DCS Communicator, IP telephone, HomeServer plug-in) may be logged onto the DCS-IP-gateway simultaneously. It should be noted that the DCS Communicator can be installed on as many user PCs as desired.
Connection terminals
-
BUS IN
Connection for the incoming video signal from door stations with a video function or camera gateways on the Gira 2-wire bus.
Because the video signal in the DCS-IP-gateway is only routed in one direction, from BUS IN to BUS OUT, all door stations with a video function or camera gateways must be connected to BUS IN. -
BUS OUT
Connection of the DCS-IP-gateway to the video control device as well as all other door communication devices such as door stations with an audio function, home stations, VideoTerminals or switching actuators via the Gira 2-wire bus. -
Ub
Connection for the power supply 24 V DC (neutral). -
LAN
Link this connection to the router or switch using a network cable to maintain access to the network.
Installation
Important
Installation and mounting of electrical devices may only be carried out by a
qualified electrician.
For installation protected from dripping and sprayed water, the DCS-IP-gate- way is mounted on a top-hat rail in the distribution. The Gira 2-wire bus and the power supply are connected via screw terminals. The network connection is carried out via the RJ45 network connection socket 10/100 Mbit/s.
Start-up
- Assigning the DCS-IP-gateway to the video control device
- At the beginning of start-up, the DCS-IP-gateway must be assigned to the video control device.
- To do so, within 30 minutes of initially starting the DCS-IP-gateway
- (LED illuminates green), programming mode must be started on the control device.
- If the time is exceeded, the DCS-IP-gateway must be completely disconnected from the power supply prior to retrying the assignment (power supply and bus voltage).
After installing all of the devices (door and home stations, control device,
DCS-IP-gateway, IP camera, etc.) the door communication system can be started
up.
When starting up the door communication system, observe the following
sequence:
- Assign analogue components (door and home stations, DCS-camera-gateway, etc) to one another and start them up.
- Find DCS-IP-gateway in the network.
- Configure DCS-IP-gateway using the Assistant.
- Install DCS Communicator on the user PC.
Finding the DCS-IP-gateway in the network
Start-up of the DCS-IP-gateway is via web interface. For this, the start-up PC
must have a current web browser (e.g. Mozilla Firefox, Microsoft Internet
Explorer, Apple Safari, Google Chrome).
For start-up, the start-up PC is connected to the network in which the DCS-IP-
gateway is also located. The DCS-IP-gateway attempts to obtain an IP address
via a DHCP server in the network.
Depending on the network type, there are several possibilities to call up the
start page of the DCS-IP-gateway using web browsers:
-
There is an active DHCP server in the network
If DHCP (Dynamic Host Configuration Protocol) is activated in the network, dynamic IP addresses are assigned for the network components, i.e. all devices are automatically assigned an IP address.
In this case, http://TKS-IP-Gateway.local
can be entered in the address line of the web browser to access the start page of the Assistant. -
No DHCP server activated in the network
If the DCS-IP-gateway does not recognise a DHCP server in the network, the following IP address is used: 192.168.0.12.
In this case, there are two possibilities to access the start page of the Assistant:-
Configure the start-up PC so that the address range 192.168.0.XXX can be accessed.
Then enter the IP address of the DCS-IP-gateway 192.168.0.12 in the address field of the web browser to access the start page of the Assistant. -
Use the included DCS-IP-gateway Finder.
-
DCS-IP-gateway Finder
The DCS-IP-gateway Finder searches for DCS-IP-gateways in the network. The
DCS-IP-gateway Finder is required e.g. when no DHCP is used in the network or
if there is more than one DCS-IP-gateway in a network.
You can obtain the TKS IP Gateway Finder free of charge in the Gira download
area at www.download.gira.com.
Installing the DCS-IP-gateway Finder
The DCS-IP-gateway Finder can also be permanently installed on the start-up
PC.
For this, please run the installation file TKS-IP-Gateway-Finder_Setup.exe
(Windows) or TKS-IP-Gateway-Finder_Setup.dmg (Mac OS) on the included CD and
follow the directions of the installation software.
The DCS-IP-gateway Finder lists all of the DCS-IP-gateways with the
corresponding network parameters:
All network settings of the listed DCS-IP-gateways can be changed or adapted
to the existing network in the DCS-IP-gateway Finder.
If the IP address of the desired DCS-IP-gateway is entered in the address line
of the web browser of the start-up PC, the log-on screen of the Gira Assistant
appears.
Gira Assistant
If the correct address of the DCS-IP-gateway is entered in the web browser,
the log-on screen of the Gira Assistant appears after approx. 30
seconds.
-
Defining access data
The DCS-IP-gateway is password-protected from unauthorised access. For this reason, an administrator name with a password must be assigned during the initial start-up. -
Have you forgotten your administrator name and/or password?
If the administrator name or password is no longer available, the DCS-IP- gateway can be reset to the state of delivery using the Reset button. -
Online help
The online help of the Assistant is located on the right edge of the screen. If the help is not visible, the help column is displayed by clicking on “Help”. The online help is context-sensitive, i.e. it always adapts to the displayed page contents.
Type and scope of the assistants
The Gira Assistant is divided into several individual assistants. The number
and type of the individual assistants is determined by defining the scope of
the system.
That means that only those assistants should be processed which are necessary
for each door communication system with the respective components used.
Processing sequence
The processing sequence of the individual assistants is arbitrary. However,
processing the assistant from top to bottom is recommended.
Assistant which have already been visited and processed are indicated with a
filled-in dot at the end of the line. Moreover, the “Edit” button then becomes
visible in some assistants.
The assistants can be called up again to carry out modifications or additions
at any time via the Edit button.
Installing DCS Communicator
The Gira DCS Communicator is the home station on the user PC.
To install it, the installation file must first be downloaded from the DCS-IP-
gateway:
- Call up the Assistant of the DCS-IP-gateway with the web browser.
- Click on “Install DCS Communicator on client PC” in the administration area of the Assistant and select the desired operating system.
- The file TKS-Communicator_Setup.exe (Windows) or TKS-Communicator_Setup.dmg (Mac OS) is downloaded from the DCS-IP-gateway and can then be saved, e.g. on a USB stick.
- Copy the respective installation file to the user PC and run it locally there.
- Follow the directions of the installation software for the further installation.
Installation with Mac OS
After running the installation file, both app files must be pulled into the
application folder.
Firewall message
- Depending on the firewall setting, the initial start of the DCS Communicator could trigger a security warning.
- Depending on the operating system, please confirm the message with “No longer block”, “Allow access” (Windows) or “Open” (Mac OS).
Audio Assistant
During the initial start of the DCS Communicator, the information appears that
the Audio Assistant should be run on the user PC. Please confirm the
information message with “OK” to start the Audio Assistant.
With the Audio Assistant, the acoustic properties of the microphone and the
loudspeaker on the user PC are optimised and adjusted automatically. Please
start the Audio Assistant and follow the instructions on the
screen.
Exchanging audio components
If the audio components on the user PC are replaced (e.g. with a new head-
set), the Audio Assistant must be run again.
DCS Communicator
When starting the DCS Communicator, the user name and password must be
entered:
After successfully logging on, the interface of the DCS Communicator appe-ars:
Resetting the DCS-IP-gateway to the state of delivery
If the administrator name or password is no longer available, the DCS-IP-
gateway can be reset to the state of delivery using the Reset button. The
Reset button is located behind the cover plate on the front of the DCS-IP-
gateway.
Important
When reset, the DCS-IP-gateway loses all its settings (incl. network settings)
and is reset to the state of delivery.
Subsequently the DCS-IP-gateway must be reconfigured or a setting which was
saved in advance can be restored.
To reset the DCS-IP-gateway to its state of delivery:
- Press the Reset button on the DCS-IP-gateway for 6 seconds.
- The LED illuminates yellow after 3 seconds.
- The LED flashes yellow after 6 seconds.
- Release the Reset button.
- The LED illuminates yellow, the device is reset to factory settings and restarted.
- The LED illuminates green, the restart is completed and the device is ready for operation.
Technical data
- Power supply: 24 V DC (neutral), 300 mA
- Use the power supply for door communication
- (Order No. 1296 00).
- Connections: 2 screw terminals for power supply
- 2 screw terminals BUS IN
- 2 screw terminals BUS OUT
- 1 RJ45 network connection, 10/100 Mbit/s
- Temperature range: -5 °C to +50 °C
- Memory card: MicroSDHC card up to max. 32 GB
- Ringing tones: 10 .wav files up to max. 5.5 MB each
- Dimensions: 6 HP
- Power consumption: 1.6 W (standby)
- 5.0 W (conversation mode)
- Minimum requirements of the start-up PC
- An up-to-date web browser is used for commissioning.
- Minimum requirements for the DCS Communicator (user PC)
- Operating system: Windows, Mac OS
- Network connection: Ethernet 10/100 Mbit/s
- RAM: 2 GB RAM
- Disk space: 100 MB
- Processor: from Intel Pentium DualCore, 2,2 GHz
- or 100 % compatible processor
- Audio components: Sound card, loudspeaker and microphone
LED display
The operating LED on the DCS-IP-gateway signalizes the following states.
Operating LED
Illuminates green| Trouble-free normal operation
Flashes green| System programming mode active
Illuminates yellow| Restart of the device / Booting phase
Flashes yellow| During the reset process or during a firmware update
Illuminates red| No additional supply connected
Flashes red| Connection to the Gira 2-wire bus missing/faulty
Warning
Due to the analogue video transmission, there may be picture disturbances
in the event of EMC interference on the telecommunication bus line caused by
the cables.
Appendix
Trans- port layer | Proto- col | Port | from | to | Intended use | Bidi- rectio- nal |
---|---|---|---|---|---|---|
UDP | pro- prie- tary | 31337 | DCS- |
Communicator
| Broadcast| Detection DCS-IP-Gate- ways in the local net- work| –
UDP
| pro- prie- tary|
31337
| DCS-
Communicator
| DCS-IP-
Gateway
| Detection DCS-IP-Gate- way in the VPN-network|
yes
UDP
| pro- prie- tary|
31337
| DCS-IP-Gate-
way Finder
|
Broadcast
| Detection DCS-IP-Gate- ways in the network|
–
UDP
| pro- prie- tary|
31337
| DCS-IP-
Gateway
| DCS-
Communicator
| Detection DCS-IP-Gate- ways in the local network|
–
UDP
| pro- prie- tary|
31337
| DCS-IP-
Gateway
| DCS-IP-Gate-
way Finder
| Detection DCS-IP-Gate- ways in the local network|
–
UDP| SIP| 5060| DCS-
Communicator
| DCS-IP-
Gateway
| Protocol for SIP-telephony| yes
UDP| SIP| 5060| external SIP-Telefon| DCS-IP-
Gateway
| Protocol for SIP-telephony| –
UDP
|
SIP
| depending on sip-phone default: 50600| DCS-IP-
Gateway
| external SIP- Telefon| Protocol for SIP-telephony|
no
UDP| RTP| 7078| DCS-
Communicator
| DCS-IP-
Gateway
| audio data| yes
UDP| RTP| 7078| external SIP-Telefon| DCS-IP-
Gateway
| audio data| no
| | depending on sip-phone default: 7078| DCS-IP-
Gateway
| external SIP-Telefon| |
no
UDP| RTP| 9078| DCS-
Communicator
| DCS-IP-
Gateway
| video data| yes
UDP| RTP| 9078| external SIP-Telefon| DCS-IP-
Gateway
| video data| no
| | depending on sip-phone default: 9078| DCS-IP-
Gateway
| external SIP-Telefon| |
no
UDP| RTP| 9058| DCS-
Communicator
| Mobotix x24- Camera| video data| no
UDP| RTP| 9000-9999| DCS-IP-
Gateway
| external RTSP-Camera| RTSP-Stream IP-Cams| yes
TCP| RTSP| freely configurable default: 554| DCS-IP-
Gateway
| external RTSP-Camera| RTSP-Stream IP-Cams| yes
TCP| pro- prie- tary| freely configurable default: 50050| DCS-IP-
Gateway
| GIRA Home- Server| encrypted data communication|
yes
TCP| http| 80| external PC| DCS-IP-
Gateway
| Access for the webinter- face. Port forwarding to Port 8080|
yes
TCP| http| 8080| external PC| DCS-IP- Gateway| Access for the winter- face.| yes
Warranty
- The warranty is provided in accordance with statutory requirements via the specialist trade.
- Please submit or send faulty devices postage paid together with an error description to your responsible salesperson (specialist trade/installation company/electrical specialist trade).
- They will forward the devices to the Gira Service Center.
TKS-IP-GatAeway
- Gira
- Giersiepen GmbH & Co. KG Elektro-Installations-Systeme
- Industriegebiet Mermbach Dahlienstraße
- 42477 Radevormwald
- Postfach 1220
- 42461 Radevormwald
- Deutschland
- Tel +49 (0) 21 95 / 602 – 0 Fax +49 (0) 21 95 / 602 – 191
- www.gira.de
- info@gira.de
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>