Bio Green PAL 2.0 USDT Palma Greenhouse Heater with Thermostat Instruction Manual

June 17, 2024
Bio Green

Bio Green PAL 2.0 USDT Palma Greenhouse Heater with Thermostat

Bio-Green-PAL-2-0-USDT-Palma-Greenhouse-Heater-with-Thermostat-
product

Introduction

  • This manual is intended for the Palma Twin – Manual. The Palma Twin -Manual is a recirculation fan heater.
  • The Palma Twin – Manual is used for temperature control of greenhouses and conservatories.

WARNING!
To reduce the risk of fire, electric shock, or personal injury, read carefully and follow these instructions as well as the general advice on safety and risks before installation. Keep this leaflet in a safe place for future reference. If you have any doubt about the safety of the unit seek the advice of an expert. If the unit is used in a greenhouse make sure that the electrical connections are carried out by qualified personnel.

Technical specifications

Palma Twin (manual)

  • Decisive type: Air circulation heater Stainless steel outer casing
  • Power supply: 110VAC ±10%, 50/60Hz
  • Maximum Performance: 2 x 750 W ~ 1500 W
  • Air circulation: 163 m³/h
  • Maximum power consumption: 13,6 A
  • Control range: 32 ± 46°F to 140 ± 43°F
  • Input: <1,5W
  • Protection class: I
  • Protection system: IP X4
  • Dimensions: 11 x 8 x 11,5″

Overviews

Overview Palma Twin

Bio-Green-PAL-2-0-USDT-Palma-Greenhouse-Heater-with-Thermostat-
fig-2

IMPORTANT INSTRUCTIONS

SAVE THESE INSTRUCTIONS
Preventive measures and safety instructions

Definition of Terms

Warning! A warning indicates the risk of damage to the user or the product if the user does not carry out the procedures with care.
Please note! A comment makes the user aware of possible problems.

Safety and hazard notes

  • Warning! This product is only suitable for well-insulated areas or occasional use.
  • Warning! Do not leave the packaging materials (plastic bags, polystyrene, nails etc.) within reach of children as they represent potential hazards.
  • Warning! This device is only approved for connection to 110VAC, 50/60Hz AC Voltage. It must be protected from heavy soiling and moisture. Different uses to those described above can lead to damage to the device, e.g. short circuit, electric shock etc. Always follow the safety and installation instructions.
  • Warning! Use this unit indoors only. Do NOT use outdoors.
  • Warning! The device is not suitable for use in cattle breeding areas.
  • Warning! The device must be disconnected from the mains supply when opening the cover or removing parts.
  • Warning! Never insert or remove the mains plug with wet hands.
  • Warning! Never pull on the power cable itself. Pull the mains plug out of the socket by the retaining device.
  • Warning! Keep the product out of reach of children.
  • Warning! A heater has hot and arcing or sparking parts inside. Never use the unit in a highly flammable environment (e.g. near heating gas, spray bottles, gasoline, paint or flammable liquids).
  • Warning! Do not cover the heater.
  • Warning! Never install the device close to taps, wash basins or other water sources. Also, never connect your heater to a power source if its surface is damp.
  • Warning! Do not insert any objects into the openings on the device as this risks injury, electric shock or damage to the device.
  • Warning! The installation location must be selected so that the devices cannot be sprayed with water or fall into water in any event.
  • Warning! Electrical devices may only be operated in wet rooms connected to a residual current circuit breaker.
  • Warning! Never submerge the device in water.
  • Warning! The guarantee is not valid if the repairs are not carried out correctly.
  • Warning! In commercial premises the accident prevention regulations of the employers liability insurance association for electrical equipment and facilities must be observed.
  • Warning! These operating instructions form a constituent part of the device and should be kept in a safe place. If the device is passed on to a third party then these instructions should be passed on with it.
  • Warning! Never pour liquids over the device. In the event that this happens remove the plug from the socket and consult a specialist.
  • Warning! The housing heats up during operation. Install it in such a way that accidental contact is avoided. After switching off, the unit cools down only slowly. Transport it only by the carrying handle, which has been specially designed for this purpose.
  • Warning! Never dry flammable objects in front of the exhaust openings.
  • Warning! When assembling, make sure that the connection cable is not crushed or damaged by sharp edges. If such damage has resulted in open spots, the unit must not be reconnected to the mains for any reason.
  • Warning! Always unplug the appliance from the socket before cleaning it. Only clean the appliance with a damp (not wet) cloth.
  • Warning! This heater is not intended for use in bathrooms, laundry areas and similar indoor locations.
  • Never locate heater where it may fall into a bathtub or other water container.
  • Warning! Always unplug the unit from the socket if it is not to be used for a long period of time. During this time, store it in a dry, protected room. To disconnect heater, turn controls to off, then remove plug from outlet.
  • Warning! If it can be assumed that safe operation is no longer guaranteed, the unit must no longer be operated and must be secured against accidental operation. These are such cases:
  • If there is visible damage to the unit or mains cable.
  • If the unit no longer works.
  • After a long storage period in unfavourable conditions.
  • After heavy use during transport.
  • Warning! Only transport it using the carrying handle that is designed for this purpose.
  • Warning! Never store or use flammable materials near the appliance.
  • Please note! This device is not designed for use by persons (including children) who have limited physical, sensory or mental capabilities and also not by persons with insufficient experience or knowledge of handling this product except where they are monitored or instructed by a person who is responsible for their safety.
  • Please note! After unpacking the device and before initial operation please ensure that the device and all the relevant accessories are in good working order. If transport damage is ascertained then please contact the corresponding distributor or manufacturer immediately.
  • Please note! Consult a specialist if you have any doubts regarding the functioning, safety or connection of the device.
  • Warning! Extreme caution is necessary when any heater is used by or near children or invalids and whenever the heater is left operating and unattended!
  • Warning! Do not operate any heater with a damaged cord or plug or after the heater malfunctions, has been dropped or damaged in any manner. Discard heater, or return to authorized service facility for examination and/or repair.
  • Warning! Hyperthermia can result in death. Symptoms of hyperthermia include high body temperature, headache, nausea, vomiting, tiredness, dizziness, fainting, and rapid pulse. If you begin to experience symptoms related to hyperthermia, turn off the heater and seek medical attention.
  • Warning! To avoid excessive room temperatures which can cause hyperthermia: DO NOT leave product running unattended in a confined space around infants, or individuals with reduced physical, sensory, or mental capabilities.

Please note! SAVE THESE INSTRUCTIONS

Installation

  • Warning! Electrical appliances may only be operated in damp rooms that are protected by residual current circuit breakers (RCD).
  • Warning! Before initial commissioning, check that the planned location has such a connection.
  • Warning! When using multiple sockets or extension cables, make sure that the maximum current carrying capacity is not exceeded. Cable drums must always be fully unrolled.
  • Warning! The installation site must be selected so that the unit cannot be sprayed with water or fall into water under any circumstances.
  • Warning! Do not wrap the connection cable around the unit and never operate the unit with a wrapped cable. Always plug heaters directly into a wall outlet/receptacle. Never use with an extension cord or relocatable power tap (outlet/power strip).
  • Please note! Lay the connection cable so that no one can trip over it, it cannot be crushed or come into contact with hot objects.
  • Please note! Only use extension cables that are compatible with the output and comply with the valid safety regulations of the unit. Connect to properly grounded outlets only.
  • Please note! Make sure to disconnect the unit from the mains before and during Installation.

This heater is for use on 110VAC, 50/60Hz only.

Warning! Never try to operate the device using a different voltage.
The cord has a plug as shown at A in below figure. An adapter as shown at C is available for connecting three-blade grounding-type plugs to two-slot receptacles. The green grounding lug extending from the adapter must be connected to a permanent ground such as a properly grounded outlet box. The adapter should not be used if a three-slot grounded receptacle is available.

Installation der Palma Twin – Manuell

Warning! This heater is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. If provided, use handles when moving this heater. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes, and curtains at least a 3 feet (0.9 m) from the front of the heater and keep them away from the sides and rear (see figure below).
Warning! If possible, leave a free space of 1.5 metres in front of the outlet opening.

Insert the plug (2.0) of the Palma Twin (1.0) directly into the mains socket (5.0).
Warning! Never insert or remove the power plug with wet hands. When using a multiple socket or an extension cable please ensure that the maximum current carrying capacity is not exceeded. Cable drums must always be completely unrolled. Do not wrap the connection cable around the device and never operate the device with wound cable. Never pull the power cord itself; only remove the plug from the socket holding the grips on the mains plug.

Bio-Green-PAL-2-0-USDT-Palma-Greenhouse-Heater-with-Thermostat-
fig-5

Using the Palma Twin – Manual

General operation
The Palma Twin recirculating air heater is equipped with a thermostat switch and a selector switch. With the selection switch, you can select one of 3 possible operating modes. These are “Recirculation”, “750 W heat output” and “1.5 kw heat output”.

Modi of the Palma Twin – Manual

  • Unit not in operation
  • Circulating air without heating (circulation in continuous operation)
  • 750W heating capacity (heating controlled by the thermostat, recirculation in continuous operation)
  • 1.5kW heating capacity (heating controlled by the thermostat, recirculation in continuous operation)

Using the Palma Twin in recirculation mode

On the selection switch, select position “Recirculation” as the mode. In this mode, there is NO heating.
Manual: Plug the Palma Twin – Manual fan heater directly into the mains socket. The Palma Twin will now run in continuous operation. During the summer months, you can achieve a reduction in the temperature in the greenhouse by using the recirculation mode. In this operating mode, open the door or the skylight of your greenhouse.
Please note! In this operating mode, the position of the thermostat switch is irrelevant. The greenhouse air heated by the sun is constantly circulated in recirculation mode and in this way transported to the outside. At the same time, this regulates the humidity in the greenhouse and promotes pollination of your plants.

Bio-Green-PAL-2-0-USDT-Palma-Greenhouse-Heater-with-Thermostat-
fig-11

Using the Palma Twin – Manual in “750W heating mode”

If you want to heat a room or a greenhouse, use one of the two operating modes for heating. The “750W heating mode” is selected by setting the right selection switch to the symbol. You can now regulate the temperature with the left-hand temperature switch. If you are using the Palma Twin without a digital temperature display, you can use a thermometer to determine the temperature in the room. If the temperature is too high or too low, you can adjust it by turning the left thermostat switch. When the desired room temperature is reached, slowly turn the thermostat counterclockwise until the switch-off point is reached. The switch-off point means that the heating heats up to this point (heating is indicated by the red signal light). If the left switch is set below this switch-off point, the fan heater does not heat, even though you may have set the fan heater to “heating” mode. The fan heater always heats the room as soon as the room temperature falls below the set level (switch-off point). You can also hear the switch-off point by a “click” or recognise it by the signal light (above the switch-off point, the signal light lights up, and heating is in progress. Below the switch-off point the signal light does not light up, the Palma is not heating). If there are temperature discrepancies, you must adjust them slightly. Due to the bimetal thermostat’s measuring tolerance of ± 41°F, it may be necessary to check the set temperature with a thermometer and readjust if necessary.

Please note! Unfortunately, it is not possible to attach a temperature scale to the thermostat switch, as the behaviour of each greenhouse varies depending on size, insulation, fill level and location.
The illustration shows as an example: Palma Twin set to 750W heating on level 8.

Bio-Green-PAL-2-0-USDT-Palma-Greenhouse-Heater-with-Thermostat-
fig-12

Using the Palma Twin – Manual in “1.5kW heating mode”

If you want to heat a room or a greenhouse, use one of the two operating modes for heating. The “1.5kw heating mode” is selected by setting the right-hand selection switch to the symbol. You can now regulate the temperature with the left-hand temperature switch. If you are using the Palma Twin without a digital temperature display, you can use a thermometer to determine the temperature in the room. If the temperature is too high or too low, you can adjust it by turning the left thermostat switch. When the desired room temperature is reached, slowly turn the thermostat counterclockwise until the switch-off point is reached. The switch-off point means that the heating heats up to this point (heating is indicated by the red signal light). If the left switch is set below this switch-off point, the fan heater does not heat, even though you may have set the fan heater to “heating” mode. The fan heater always heats the room as soon as the room temperature falls below the set level (switch-off point). You can also hear the switch-off point by a “click” or recognise it by the signal light (above the switch-off point, the signal light lights up, heating is in progress. Below the switch-off point the signal light does not light up, the Palma is not heating). If there are temperature discrepancies, you must adjust them slightly. Due to the bimetal thermostat’s measuring tolerance of ± 41°F, it may be necessary to check the set temperature with a thermometer and readjust if necessary.

Please note! Unfortunately, it is not possible to print a temperature scale on the thermostat switch, as the behaviour of each greenhouse varies according to size, insulation, filling level and location.
The illustration shows as an example: Palma Twin set to 1.5kw heating on level 8.

Bio-Green-PAL-2-0-USDT-Palma-Greenhouse-Heater-with-Thermostat-
fig-13

Safety features

  • Temperature-controlled circuit breaker: If the device overheats the temperature-controlled circuit breaker will switch the device off temporarily. To switch the device back on, turn the heater off for 5 to 10 minutes to cool down Another reason for the shutdown would be blockage of the intake or outlet opening.
  • In this case please remove the corresponding objects. It could also be an indication that the ventilator has failed. In this case switch the heater (1) off, remove the plug (2) from the socket (5) and contact an authorized specialist to arrange repair.

Warning! The casing heats up during operation. Install in such a way that accidental contact is avoided. The device only cools slowly after it is switched off. Only transport it using the carrying handle that is designed for this purpose and do not touch the surface of the heater.

Cleaning, maintenance, environment and disposal

Cleaning and maintenance

Warning! Switch the device off before each cleaning and leave it to cool for approximately 30 minutes before beginning cleaning.
Warning! Do not use any abrasive, caustic or cleaning materials.
Clean the casing with a damp cloth (not wet), vacuum cleaner or feather duster.

Environment and disposal

Please note! Only dispose of devices at a corresponding collection centre.
Please note! Only authorized specialists are permitted to carry out repairs on the device. Please contact the manufacturer or distributor in this regard.
Warning! Incorrectly executed repairs can represent a hazard for the user and other persons.
The manufacturer does not accept responsibility for any damage caused by frost, insufficient heating performance for the room dimensions or insufficient heat insulation.

MANUFACTURER’S REPRESENTATIONS AND WARRANTIES

  • Bio Green USA Inc.
  • 2881 Busse Road,
  • Elk Grove Village, IL 60007
  • United States
  • Email: [email protected].

These Representations and Warranties are applicable to all customers (the “Customers” and each, individually, a “Customer”) purchasing products (the “Products”) manufactured by Bio Green GmbH (the “Company”).

Warranty and Limitations

  1. Company warrants solely to the original purchaser of the Products that for the
    Warranty Period (as defined below), the Products will be free from defects in materials and workmanship under normal use, and will conform to Company’s published specifications of the Products. Notwithstanding the foregoing, Company retains its right to deviate from its published specifications due to the latest innovations and improvements in function and design of the Products.

  2. The foregoing warranty is subject to the proper storage, transportation and use of the Products, and does not include defects due to normal wear and tear or deterioration.

  3. Customer shall immediately, but in any event no later than eight (8) days following delivery of the Product, inspect the Products for conformity and visible defects. Customer shall give Company immediate written notice of any nonconformities or visible defects regarding the Products. In the event that Customer fails to provide the Company within eight (8) days following delivery of the Products with notice of any non-conformities or visible defects, any warranty claims in this regard shall be deemed waived.

  4. Customer shall immediately notify Company in writing of any other defects of the Products and return such defective Product. Prior to any shipment of a defective Product, Customer shall contact Company first at the address provided in 1.9.
    Company’s sole obligation under the foregoing warranty is, at Company’s option and in its sole discretion, to repair, replace or exchange the defective Product. Any repaired, replaced or exchanged Products shall be subject to this warranty, following their repair, replacement or exchange. If Company has received notification from Customer, and no defects of the Product could be discovered, Customer shall bear the costs that Company incurred as a result of the notice. It shall be in Company’s sole discretion to determine if the Product has a defect. In no event shall Company bear the costs of disassembly.

  5. With respect to orders made to custom, any defects of the Products caused by Customer’s specifications are excluded from the warranty set forth in 1.1.

  6. Company also makes no warranty that the Products manufactured under an order made to custom do not infringe the intellectual property or other proprietary rights of any third party and Customer is solely responsible for assuring that such Products do not so infringe.

  7. The “Warranty Period” begins on the date of delivery of the Product to Customer, and continues to be in effect for twenty-four (24) months. The “Warranty Period” shall be suspended for the time of repair, replacement or exchange until the repaired, exchanged or replaced product has been returned to Customer.

  8. Company does not authorize any person or party to assume or create for it any other obligation or liability in connection with the Products except as set forth herein.

  9. All requests and notices under this Warranty shall be directed to:

    • Bio Green USA Inc.
    • 2881 Busse Road,
    • Elk Grove Village, IL 60007
    • United States
    • Email: [email protected]
  10. THE WARRANTY SET FORTH IN SECTION 1.1 IS MADE IN LIEU OF ALL OTHER WARRANTIES (WHETHER EXPRESS OR IMPLIED), RIGHTS OR CONDITIONS, AND CUSTOMER ACKNOWLEDGES THAT EXCEPT FOR SUCH LIMITED WARRANTY, THE PRODUCTS ARE PROVIDED “AS IS.” COMPANY SPECIFICALLY DISCLAIMS, WITHOUT LIMITATION, ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, OF ANY KIND, INCLUDING, WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, NONINFRINGEMENT, AND THOSE WARRANTIES ARISING FROM A COURSE OF PERFORMANCE, A COURSE OF DEALING OR TRADE USAGE.

Limitation of Liability

  1. IN NO EVENT SHALL COMPANY BE LIABLE FOR ANY INDIRECT, INCIDENTAL, PUNITIVE, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO, DAMAGES FOR LOSS OF PROFITS, REVENUE, GOODWILL OR USE, INCURRED BY CUSTOMER OR ANY THIRD PARTY, WHETHER IN AN ACTION IN CONTRACT, TORT, STRICT LIABILITY, OR IMPOSED BY STATUTE, OR OTHERWISE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. COMPANY’S LIABILITY FOR DAMAGES ARISING OUT OF OR IN CONNECTION WITH THIS AGREEMENT SHALL IN NO EVENT EXCEED THE PURCHASE PRICE OF THE PRODUCTS. IT IS AGREED AND ACKNOWLEDGED THAT THE PROVISIONS OF THIS AGREEMENT ALLOCATE THE RISKS BETWEEN COMPANY AND CUSTOMER, THAT COMPANY’S PRICING REFLECTS THIS ALLOCATION OF RISK, AND BUT FOR THIS ALLOCATION AND LIMITATION OF LIABILITY, COMPANY WOULD NOT HAVE ENTERED INTO THIS AGREEMENT.
  2. IN JURISDICTIONS THAT LIMIT THE SCOPE OF OR PRECLUDE LIMITATIONS OR EXCLUSION OF REMEDIES OR DAMAGES, OR OF LIABILITY, SUCH AS LIABILITY FOR GROSS NEGLIGENCE OR WILLFUL MISCONDUCT OR DO NOT ALLOW IMPLIED WARRANTIES TO BE EXCLUDED, THE LIMITATION OR EXCLUSION OF WARRANTIES, REMEDIES, DAMAGES OR LIABILITY SET FORTH ABOVE ARE INTENDED TO APPLY TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW. CUSTOMER MAY ALSO HAVE OTHER RIGHTS THAT VARY BY STATE, COUNTRY OR OTHER JURISDICTION.

CONTACT

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Bio Green User Manuals