Bio Green PHX2.8/US Portable Phoenix Greenhouse Tent Heater Instruction Manual
- June 5, 2024
- Bio Green
Table of Contents
- Bio Green PHX2.8/US Portable Phoenix Greenhouse Tent Heater
- Quick reference guide
- Ceiling mounting
- Delivery Checklist
- Technical data
- General
- Safety and hazard notes
- Installation
- Operation
- Safety feature
- Cleaning, repairs, and disposal
- MANUFACTURER’S REPRESENTATIONS AND WARRANTIES
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Bio Green PHX2.8/US Portable Phoenix Greenhouse Tent Heater
Quick reference guide
Ceiling mounting
Unscrew the stand feet
Safety distance on both sides
READ ALL INSTRUCTIONS FIRST BEFORE INSTALLING THE PHOENIX HEATER!
DO NOT DRINK ANY ALCOHOL OR TAKE ANY DRUGS BEFORE OR DURING THE INSTALLATION
OF THE PHOENIX HEATER AND
FOLLOW THE SAFETY INSTRUCTIONS CAREFULLY.
Delivery Checklist
- 1x air circulation heater PHX 2.8/US
- 2x chain with snap hook
- 2x cropped head bolts & nuts with rings
Technical data
- Apparatus type: PHX 2.8/US
- Power supply: 240 V ~ / 60 Hz
- Power: 1000 W / 1800W/ 2800 W
- BTUs: 3412 / 6142 / 9554
- Current: 13 A (max.)
- Control range: 32 – 79 °F
- Protection category: I
IMPORTANT:
Familiarise yourself with the instructions in this manual and the general safety and hazard notes before installation. Keep this document in a safe place for future reference. If you have any doubts about the safety of the apparatus, please consult a skilled person. When installing in a greenhouse, please ensure that the electrical connections are made by a qualified person.
General
After unpacking and before using it for the first time, ensure that the apparatus and all the accessories are not damaged. In case of transport damage, please contact your distributor or the manufacturer immediately. Keep packaging material (polybags, polystyrene, nails etc.) out of reach of children, since such materials are hazardous. The PHX 2.8/US electric air circulation heater is designed to heat greenhouses and winter gardens uniformly, also saving energy. Its defining features include simple operation and minimum installation space requirement. This apparatus is designed for connection to 240 V ~ 60 Hz AC only. It must be protected against heavy soiling and moisture. Any use other than that described above may damage the apparatus and also carries risks of e.g. short circuits, fire, electric shock, etc. It is imperative that the safety and installation instructions are followed.
Safety and hazard notes
-
Use only with a 240 V ~60 Hz mains socket with an RCCB (Residiual Current Circuit Braker protection.
-
Never attempt to operate the apparatus with a different voltage.
-
If you are unsure about the usage, safety or connection of the apparatus, please consult an authorized specialist.
-
This apparatus is for indoor use only.
-
The apparatus must be unplugged from mains before opening the cover or removing components.
-
Never touch the mains plug with wet hands.
-
Never pull on the power cable, pull the plug only by gripping it by the surfaces provided.
-
Never store or use flammable materials or spray near the apparatus. Fire hazard!
-
Do not use the apparatus in a flammable atmosphere (e.g. close to combustion gas or spray cans). Explosion and fire hazard!
-
Do not cover the heater. Fire hazard!
-
Never install the apparatus near taps, basins or other sources of water. Also never connect your heater to a power supply unless its surfaces are dry.
-
Do not insert objects into the openings of the apparatus. Risk of injury, electric shock or risk of damage to the appliance!
-
The enclosure heats up during operation. Install the appliance in such a way so as to prevent accidental contact. Danger of burning! After switching off, the appliance cools down only slowly. Carry only by the handle provided.
-
Never dry flammable objects
in front of the exhaust openings. Fire hazard! -
When installing, ensure that the connecting cord is not crushed or damaged by sharp edges. If such damage should expose the wires, the appliance must under no circumstances be connected to the power supply. Life-threatening!
-
Always disconnect from the mains before cleaning the appliance. Clean only with a damp (not wet) cloth.
-
Always disconnect from the mains if the appliance will not be used any length of time. During this time, store your heater in a protected and dry place.
-
If it may be assumed that the apparatus can no longer be safely operated, it must be decommissioned and protected against accidental operation.
This is the case if:- the apparatus or mains chord is visibly damaged
- the apparatus no longer operates
- after extended storage in unfavorable conditions
- after rough transport conditions
-
Apparatus operated from mains voltage must be kept away from children.
-
The apparatus is not suited for use in areas used for animal husbandry.
-
These operating instructions are part of the apparatus and should be kept in a safe place. If the apparatus is passed on to third parties, it must be passed on together with the operating instructions.
-
In industrial facilities, the Accident Prevention regulations for electrical installations and operating materials of the industrial employer’s liability insurance association are to be observed.
-
Never spill fluids on the apparatus. There is a danger of fire or lethal electric shock. In such an event, unplug the mains and consult a skilled person.
-
Should you be unsure about the proper connection or should any questions arise that are not dealt with in these operating instructions, please contact the manufacturer or an authorized person.
-
This apparatus may not be operated by persons (including children) with limited physical, sensory
-
or mental faculties, or by persons who are not sufficiently experienced or adequately
-
knowledgeable in the use of the product, unless such persons are supervised or instructed in the use of the apparatus by a person responsible for their safety.
Installation
The electrical appliance may only be operated from earth leakage-protected
sockets! Before operating the apparatus, ensure that this is the case for the
socket to be used. Make sure that the maximum current is not exceeded when the
outlet has more than one socket or when using extension chords. cable reels
must always be fully unwound. Ensure that the air circulation heater is
disconnected from mains before or during installation. Select a place for
installation where the apparatus will not be exposed to rain or may fall into
the water. Route the connecting cable such that it will not be a stumbling
hazard, can-not be crushed or come into contact with hot objects. Use only
extension leads matched to the power rating of the apparatus and comply with
the applicable safety regulations. Do not wind the connecting lead around the
apparatus and never operate the apparatus with a coiled lead.
Standing installation:
To use the PHX 2.8/US greenhouse heater as a floor-mounted apparatus, the
supplied feet must first be fitted. The following supplied components are
required for assembly:
- 2 x PHOENIX feet
- 4 x self-tapping screws
- 4 x serrated washers
Have a Phillips screwdriver at hand. The PHOENIX heater comes with pre-drilled holes in the housing for attaching the feet. Fasten the feet here, using the self-tapping screws with serrated washers (see illustration on Page 2). Your PHOENIX air circulation heater is now ready to use as a floor-mounted apparatus.
Hanging installation:
To use the PHOENIX 2.8 air circulation heater as a hanging apparatus, the
supplied chains must first be fitted. The following supplied components are
required for assembly:
- 2 x PHOENIX hanging chains
- 2 x T-head Bolt and Ring Nut
The PHOENIX heater comes with metal lugs on the housing to hook the chains, using the snap hooks. The other two snap hooks then hook into the V-hooks. These V-hooks are then fastened to the profiles in your greenhouse (see illustration on Page 2). Your PHOENIX greenhouse heater is now ready to use as a hanging heater.
Operation
Connect the heating apparatus to any 240 V ~ 60 Hz AC socket. The PHOE-NIX air circulation heater has two selector switches and a thermostat. Using the selector switches, you may select one of the 8 possible operating modes. Set the desired greenhouse temperature on the thermostat. An integral lamp signals heating operation. The thermostat is linear and infinite-ly variable from 32-37°F. The printed figures from 0-10 on the adjustment wheel are for general orientation to the temperature range is selected. This means that the increasing numbers each mean a rise in temperature of approx. 37 °C (see example below). Example.: Number Temperature range Refer to page 9 in the section ‘winter operation’ to find out how to set the temperature exactly.
Selector switch:
Step 1: Select the desired operating mode on selector switches 1 and 2.
Depending on the size and location of the greenhouse we recommend selecting a
heating performance of 2800 watts or 1800 watts in the winter months. On the
other hand, the low-er performance of 1000 watts is often sufficient in the
transition periods
(autumn and spring). 1800 watts: Ideal frost protection up to a greenhouse
size of approximately 136 sq. ft. (12 m²). 2800 watts: Ideal frost protection
up to a greenhouse size of approximately 216 sq. ft. (20 m²).
Note: If you have sensitive plants in your greenhouse over the winter
(e.g. cacti) that cannot tolerate fluctuating temperatures then we recommend
heating in operating modes 3b, 4b or 5b. These operating modes give you
continual air circulation and do not produce large temperature gradients
between the upper and lower layers of air. The same is also true for
greenhouses with very high humidity. The continual circulation of air prevents
the occurrence of mold and fungi.
If you have robust plants and merely wish to prevent frost you can use
operating modes 3a, 4a, or 5a. Please consult a gardener if you have questions
in this regard.
Step 2: Select the desired temperature range on the thermostat adjustment
wheel. Refer to the example on page 8 to see which position on the thermostat
corresponds to the desired temperature and then set it accordingly. Now leave
the heating to operate for several hours and monitor the room temperature with
the help of a thermometer (MIN-MAX thermometer recommended). Then correct the
setting slightly upwards or downwards if necessary if the desired temperature
is not maintained. This setting process only needs to be carried out once
during the initial operation. The heating system will keep the temperature
constant once the correct setting has been discovered.
Note: It is unfortunately not possible to print the temperature scale on
the adjustment wheel of the thermometer as it reacts differently depending on
size, insulation, stocking, and location of each greenhouse.
Recommendation:
If you would like to keep valuable plants in your greenhouse over the winter
then we recommend installing a second heat source that is activated if this
heating fails (e.g. during a power cut). This protects your plants from
freezing.
Summer operation:
In the summer months, you can use the air circulation mode to achieve
substantial cooling of the greenhouse temperature. Select operating mode 2b
for this purpose and open the door or roof windows in your greenhouse. The
position of the thermostat adjustment wheel is irrelevant in this case. The
greenhouse air that is heated by the sun is continually circulated in
circulation mode and is transported outside. This measure also regulates the
humidity in the greenhouse and promotes the pollination of your plants.
Note: Never use operating mode 2a for summer operation. As the air
circulation is regulated by the thermostat in this mode it would switch off
the fan after a short period of strong sun exposure. This would mean that the
air circulation and the associated cooling would no longer be assured.
Safety feature
Temperature-controlled switch-off: The apparatus will automatically switch off temporarily if it should overheat. To restart, switch off the heater for 5 to 10 minutes to cool down. Another reason for automatic switch-off may be blockages in the air inlet or exhaust apertures. In this case, please remove the obstructing objects. It may, however, also be an indication that the fan has failed. In this case, switch off the heating apparatus, unplug it and call on an authorized technician for repairs.
Cleaning, repairs, and disposal
- Do not use abrasive or caustic cleaning agents.
- Before cleaning, switch off the apparatus and allow it to cool down for about 30 min. before starting with cleaning.
- Clean the enclosure with a damp cloth (not wet), vacuum cleaner or feather duster.
- Never submerge the apparatus in water.
- Take the material to be disposed of to an appropriate waste disposal point.
- The apparatus may only be repaired by authorized persons. Please contact the manufacturer or distributor in this regard.
- Attention! The guarantee is null and void in the case of improper repairs.
- Flawed repairs pose a danger to the user and other persons.
MANUFACTURER’S REPRESENTATIONS AND WARRANTIES
CTL /Co. Bio Green USA Inc. 2881 Busse Road Elk Grove Village, IL 60007
United States
Tel. 1-800-941-3169
info@biogreen-products.com
These Representations and Warranties are applicable to all customers (the
“Customers” and each, individually, a “Customer”) purchasing products (the
“Products”) manufactured by Bio Green GmbH & Co. KG (the “Company”).
Warranty and Limitations:
Company warrants solely to the original purchaser of the Products that for the
Warranty Period (as defined below), the Products will be free from defects in
materials and workmanship under normal use, and will conform to the Company’s
published specifications of the Products. Notwithstanding the foregoing,
Company retains its right to deviate from its published specifications due to
the latest innovations and improvements in the function and design of the
Products. The foregoing warranty is subject to the proper storage,
transportation and use of the Products, and does not include defects due to
normal wear and tear or deterioration. Customer shall immediately, but in any
event no later than eight (8) days following delivery of the Product, inspect
the Product for conformity and visible defects. Customer shall give Company
immediate written notice of any non-conformities or visible defects regarding
the Products. In the event that the Customer fails to provide the Company
within eight (8) days following delivery of the Products with notice of any
non-conformities or visible defects, any warranty claims in this regard shall
be deemed waived. Customer shall immediately notify Company in writing of any
other defects of the Products and return such defective Product. Prior to any
shipment of a defective Product, the Customer shall contact Company first at
the address provided in 1.9. The company’s sole obligation under the foregoing
warranty is, at Company’s option and in its sole discretion, to repair,
replace or exchange the defective Product. Any repaired, replaced or exchanged
Products shall be subject to this warranty, following their repair,
replacement or exchange. If Company has received notification from Customer,
and no defects of the Product could be discovered, Customer shall bear the
costs that Company incurred as a result of the notice. It shall be in
Company’s sole discretion to determine if the product has a defect. In no
event shall Company bear the costs of disassembly. With respect to orders made
to custom, any defects of the Products caused by the Customer’s specifications
are excluded from the warranty set forth in 1.1. The company also makes no
warranty that the Products manufactured under an order made to custom do not
infringe the intellectual property or other proprietary rights of any third
party and the Customer is solely responsible for assuring that such Products
do not so infringe. The “Warranty Period” begins on the date of delivery of
the Product to the Customer, and continues to be in effect for twenty-four
(24) months. The “Warranty Period” shall be suspended for the time of repair,
replacement or exchange until the repaired, exchanged or replaced product has
been returned to the Customer. The company does not authorize any person or
party to assume or create for it any other obligation or liability in
connection with the Products except as set forth herein. All requests and
notices under this Warranty shall be directed to:
CTL /Co. Bio Green USA Inc. 2881 Busse Road Elk Grove Village, IL 60007
United States
Tel. 1-800-941-3169
info@biogreen-products.com
THE WARRANTY SET FORTH IN SECTION 1.1 IS MADE IN LIEU OF ALL OTHER WARRANTIES (WHETHER EXPRESS OR IMPLIED), RIGHTS OR CONDITIONS, AND THE CUSTOMER ACKNOWLEDGES THAT EXCEPT FOR SUCH LIMITED WARRANTY, THE PRODUCTS ARE PROVIDED “AS IS.” THE COMPANY SPECIFICALLY DISCLAIMS, WITHOUT LIMITATION, ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, OF ANY KIND, INCLUDING, WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, NON-INFRINGEMENT, AND THOSE WARRANTIES ARISING FROM A COURSE OF PERFORMANCE, A COURSE OF DEALING OR TRADE USAGE.
Limitation of Liability:
IN NO EVENT SHALL COMPA-NY BE LIABLE FOR ANY INDIRECT, INCIDENTAL, PUNITIVE, SPECIAL, OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO, DAMAGES FOR LOSS OF PROFITS, REVENUE, GOODWILL, OR USE, INCURRED BY CUSTOMER OR ANY THIRD PARTY, WHETHER IN AN ACTION IN CONTRACT, TORT, STRICT LIABILITY, OR IMPOSED BY STATUTE, OR OTHERWISE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. THE COMPANY’S LIABILITY FOR DAMAGES ARISING OUT OF OR IN CONNECTION WITH THIS AGREE-MENT SHALL IN NO EVENT EXCEED THE PURCHASE PRICE OF THE PRODUCTS. IT IS AGREED AND ACKNOWLEDGED THAT THE PROVISIONS OF THIS AGREEMENT ALLOCATE THE RISKS BETWEEN COMPANY AND CUSTOMER, THAT COMPANY’S PRICING REFLECTS THIS ALLOCATION OF RISK, AND BUT FOR THIS ALLOCATION AND LIMITATION OF LIABILITY, THE COMPANY WOULD NOT HAVE ENTERED INTO THIS AGREE-MENT. IN JURISDICTIONS THAT LIMIT THE SCOPE OF OR PRECLUDE LIMITATIONS OR EXCLUSION OF REME-DIES OR DAMAGES, OR OF LIABILITY, SUCH AS LIABILITY FOR GROSS NEGLIGENCE OR WILLFUL MISCONDUCT OR DO NOT ALLOW IMPLIED WARRANTIES TO BE EXCLUDED, THE LIMITATION OR EXCLUSION OF WARRANTIES, REMEDIES, DAMA- GES OR LIABILITY SET FORTH AB-OVE ARE INTENDED TO APPLY TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW. CUSTOMERS MAY ALSO HAVE OTHER RIGHTS THAT VARY BY STATE, COUNTRY OR OTHER JURISDICTION.
References
- products.com
- BioGreen USA Amazon American Express Apple Pay Diners Club Discover Facebook Pay Google Pay Mastercard PayPal Shop Pay Venmo Visa
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>