Bio Green PALMA 2.0 Heater Instruction Manual

June 3, 2024
Bio Green

Bio Green PALMA 2.0 Heater

Bio-Green-PALMA-2-0-Heater-PRODUCT

This product is only suitable for well-insulated rooms or occasional use.

Introduction

This manual is intended for the Palma 2.0 RAW and Palma 2.0. The Palma 2.0 RAW consists of an air circulation heater. The Palma 2.0 consists of the air circulation heater and a wet room thermostat Thermal. The electric air circulation heater Palma 2.0 and Palma 2.0 RAW serves to control the temperature of greenhouses and conservatories. Read and observe the directions in these instructions and the general safety and hazard notes carefully before installation. Keep this leaflet in a safe place for future reference. If you doubt the safety of this device please seek advice from a specialist. If using the device in a greenhouse please ensure that the electrical connections are installed by qualified staff.

Technical data

  • Scope of delivery

Palma 2.0-Digital

  • Air circulation heater Palma 2.0
  • 1 Digital-Termostat ”Thermo 2”

Palma 2.0

Device type| Air circulation heater
Power supply| 230 V/50-60 Hz
Maximum performance| 2025 W
Maximum power consumption| 9,0 A
Control range| 0 bis 85 °C
Controller tolerance:| ± 5 °C
Input| < 1,5 W
Protection class| I
Protective system| IP X4
Abmessungen| 280 x 195 x 315 mm

Palma 2.0- Manuell

  • Air circulation heater Palma 2.0

Thermo 2

Device type| Digital-Thermostat
Power supply| 230 V/50-60 Hz
Max. breaking capacity| 3000 W
Max. switching current| 16 A
Control range:| -50 bis +99 °C
Distinction rate| ± 1 °C
Input| < 1,5 W
Protection class| II
Protective system| IP X4
Sensor length:| approx. 2,5 m

Main component parts

Palma 2.0-Digital (1)

Bio-Green-PALMA-2-0-Heater-FIG-1

”Thermo 2” (2) (optional)

Bio-Green-PALMA-2-0-Heater-FIG-2

Preventive measures and safety instructions

Warning:  A warning indicates the risk of damage to the user or the product if the user does not carry out the procedures with care. Please note! A comment makes the user aware of possible problems.

Tip: A tip makes the user aware of convenient functions and additional options.

Safety and hazard notes

Warning

  • This device is only approved for connection to 230 V ’” / 50-60 Hz AC Voltage. It must be protected from heavy soiling and moisture. Different uses to those described above can lead to damage to the device, e.g. short circuit, electric shock etc. Always follow the safety and installation instructions.
  • The only permitted power source is a 230 V ”’, 50/60 Hz mains network socket. Never try to operate the device using a different voltage.
  • Only use this device indoors.
  • The device must be disconnected from the mains supply when opening the cover or removing parts.
  • Never insert or remove the power plug with wet hands.
  • Never pull the power cord itself; only remove the plug from the socket holding the grips on the mains plug.
  • Do not store or use inflammable materials or spray near the device.
  • Do not use the device in an easily inflammable atmosphere (e.g. close to fuel gas or spray bottles).
  • Do not cover the heater.
  • Never install the device close to taps, wash basins or other water sources. Also never connect your heater to a power source if the surface of the heater is damp.
  • Do not insert any objects into the openings on the device as this risks injury, electric shock or damage to the device.
  • The casing heats up during operation. Install the in such a way that accidental contact is avoided. The device only cools slowly after it is switched off. Only transport it using the carrying handle that is designed for this purpose.
  • Never dry inflammable objects in front of the discharge openings.
  • During assembly please ensure that the connecting cable is not crushed or damaged by sharp edges. If open points have been created by this kind of damage then the device may not be reconnected to the supply network for any reason.
  • Always remove the plug from the socket before cleaning the device. Only clean using a damp (not wet) cloth.
  • Always remove the plug from the mains if the device is taken out of service for a longer period. Store the heater in a dry, protected place for this period.
  • If it can be assumed that safe operation is no longer possible then the device must be taken out of operation and secured against accidental operation. This is the case:
    • if the device or the mains cable display visible damage;
    • if the device no longer works;
    • after a long period of storage under unfavorable conditions;
    • following severe transport stress
  • Keep the product out of reach of children.
  • The device is not suitable for use in cattle breeding areas.
  • These operating instructions form a constituent part of the device and should be kept in a safe place. If the device is passed on to a third party then these instructions should be passed on with it.
  • Never submerge the device in water.
  • The guarantee is not valid if the repairs are not carried out correctly.
  • In commercial premises the accident prevention regulations of the employer’s liability insurance association for electrical equipment and facilities must be observed.
  • Never pour liquids over the device. In the event that this happens remove the plug from the socket and consult a specialist.

Please note

  • This device is not designed for use by persons (including children) who have limited physical, sensory or mental capabilities and also not by persons with insufficient experience or knowledge of handling this product except where they are monitored or instructed by a person who is responsible for their safety.
  • After unpacking the device and before initial operation please ensure that the device and all the relevant accessories are in good working order. If transport damage is ascertained then please contact the corresponding distributor or manufacturer immediately.
  • Consult a specialist if you have any doubts regarding the functioning, safety or connection of the device.

Installation

Warning

  • Do not leave the packaging materials (plastic bags, polystyrene, nails etc.) within reach of children as they represent potential hazards.
  • Electrical devices may only be operated in wet rooms connected to a residual current circuit breaker.
  • Before initial operation of the device please ensure that this connection is provided at the planned connection location.
  • The installation location must be selected so that the devices cannot be sprayed with water or fall into water in any event.

Please note

  • Lay the connection cables in such a way that nobody can trip over them and they cannot be crushed or come into contact with hot objects.
  • Only use extension cables that are compatible with the output and in accordance with the valid safety regulations for the device.
  • Make sure that the devices are disconnected from the mains power before and during installation.

When using the Palma 2.0 heater you have the choice of operation with or without the included wet room thermostat Thermo 2. However for exact temperature regulation and energy-saving operation we urgently recommend using the Thermo 2.

  • To install the Palma 2.0, go to section 3.1.
  • To install the Palma 2.0 RAW, go to section 3.2.

Keep the Palma 2.0 clean and protect it from heavy soiling and moisture. As described in the chapter Introduction and Technical Data on page 3, the Palma 2.0 can be operated stand-alone (=Palma 2.0 RAW) or with the included wet room thermostat Thermo 2.

However, for precise temperature regulation and energy saving operation the use of the Thermo 2 is strongly recommended.

General control elements of the Thermo 2

Bio-Green-PALMA-2-0-Heater-FIG-3

Installation of Palma 2.0 heater

Warning

  • The distance from the inflammable objects should be at least 20”/ 50 cm. Adjust the heater so that there is a distance of at least 16”/ 40 cm between the wall and the air intake opening.
  • A free space of 1.5 meters should be left in front of the output opening if possible. Place the heater in your greenhouse (4).

Now insert the mains plug into the socket of the Thermo 2(5) or, if operating without the Thermo 2, directly into the mains socket (6).

Warning:  Never insert or remove the power plug with wet hands. When using a multiple socket or an extension cable please ensure that the maximum current carrying capacity is not exceeded. Cable drums must always be completely unrolled. Do not wrap the connection cable around the device and never operate the device with wound cable.

  • To set the Palma 2.0 RAW to wintermode, see section 4.2.
  • To set the Palma 2.0 to wintermode, see section 4.3.
  • To set the summer mode, see section 4.4.

Warning: Never insert or remove the power plug with wet hands.

Palma 2.0 Controls

Bio-Green-PALMA-2-0-Heater-FIG-7

Use the Palma 2.0 and Palma 2.0 RAW

General operation

When the desired room temperature is reached, turn the thermostat slowly counterclockwise until you hear a ”click” (10). Due to the bimetal thermostat’s measuring tolerance of ± 5 °C, it may be necessary to check the set temperature with a thermometer and readjust it if necessary. To do this, turn the thermostat switch in the desired direction (1-10).

Mode of the Palma 2.0

  • Device not in operation
  • Air circulation without heating (circulation in constant operation)
  • 2 kW heating output (heating controlled by thermostat, air circulation in constant operation)

Use the Palma 2.0 RAW in winter mode

  • Select position as the mode on the selector switch and set the thermostat to maximum.
  • The operation lamp will light up when the Palma 2.0 RAW starts with heating (8).
  • Check the room temperature using a thermometer (9).

When the desired room temperature is reached then slowly turn the thermostat in an anticlockwise direction until the operation lamp switches off (10).

The heater will now maintain the set temperature by re-starting the heating function when the room temperature falls below this level. In the event of temperature discrepancies you may need to adjust this a little.

ATTENTION

It is not possible to print a temperature scale around the thermostat knob because the heating behavior will differ based on the environment the Palma 2.0 RAW is used in. For example the size, insulation, filling level and location of the greenhouse where the Palma 2.0 RAW is operated in, can make a significant difference. This is why it is recommended to use use the Palma 2.0 together with the optional and included Thermo 2 thermostat as described in chapter 4.3.

Use the Palma 2.0 in winter mode

  • Set the desired room temperature on the wet room thermostat Thermo 2 (11).

  • The setting can be found in the Thermo 2 operating instructions.

  • Select position as the mode on the selector switch. And set the heater thermostat to the maximum setting (12).

The wet room thermostat Thermo 2 will now take over temperature regulation and the Palma 2.0 heater will be switched on if the room temperature falls below the set level. If the temperature is reached then the heater will switch off again.

Use the Palma 2.0 and Palma 2.0 RAW in summer mode

Please note: The Thermo 2 is not required for summer operation. Just plug the Palma 2.0 heater directly into a mains socket. In the summer months use of the air circulation mode can achieve a substantial reduction of the greenhouse temperature. Select mode 2 on the selector switch of the Palma 2.0 heater and open the door or the roof window on your greenhouse (13). The position of the thermostat switch is irrelevant here.

The greenhouse air that is heated by the sun is constantly circulated by the air circulation mode and thus moved outside. At the same time this measure regulates the humidity in the greenhouse and promotes the pollination of your plants.

Safety feature

  • Temperature controlled circuit breaker: If the device overheats the temperature-controlled circuit breaker will switch the device off temporarily.
  • To switch the device back on, turn the heater off for 5 to 10 minutes to cool down (14).

Another reason for the shutdown would be blockage of the intake or outlet opening.

  • In this case please remove the corresponding objects (14). It could also be an indication that the ventilator has failed.
  • In this case switch the heater off, remove the plug and contact an authorized specialist to arrange a repair.

Cleaning, maintenance, environment and disposal

Cleaning and maintenance

Warning:  Switch the device off before each cleaning and leave it to cool for approximately 30 minutes before beginning cleaning. Warning! Do not use any abrasive, caustic or cleaning materials. Clean the casing with a damp cloth (not wet), vacuum cleaner or feather duster.

Environment and disposal

Please note

  • Only dispose of devices at a corresponding collection centre.
  • Only authorized specialists are permitted to carry out repairs on the device.
  • Please contact the manufacturer or distributor in this regard.

Warning:  Incorrectly executed repairs can represent a hazard for the user and other persons. The manufacturer does not accept responsibility for any damage caused by frost, insufficient heating performance for the room dimensions or insufficient heat insulation.

  • ErP Produktdatenblatt nach EU 1188/2015
  • ErP Product fiche accoding to EU 1188/2015
  • Fiche ErP selon EU 1188/2015

Information required for the electric local space heaters

Bio-Green-PALMA-2-0-Heater-FIG-19

Bio Green GmbH & Co. KG

PALMA EU VER. 3 – 10112021-BG

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Bio Green User Manuals

Related Manuals