eurolite 00151597 Multiflood IP 8X10W RGBW Wash User Manual
- June 17, 2024
- eurolite
Table of Contents
- eurolite 00151597 Multiflood IP 8X10W RGBW Wash
- Product Information
- Product Usage Instructions
- FAQ
- INTRODUCTION
- Product features
- SAFETY INSTRUCTIONS
- DESCRIPTION OF THE DEVICE
- INSTALLATION
- DMX512 CONTROL
- POWER SUPPLY
- OPERATION
- EUROLITE IR-38 remote control
- DMX operation
- DMX Protocol
- CLEANING AND MAINTENANCE
- PROTECTING THE ENVIRONMENT
- TECHNICAL SPECIFICATIONS
- Accessories
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
eurolite 00151597 Multiflood IP 8X10W RGBW Wash
Product Information
Specifications
- Product Name: Multiflood IP 8x10W RGBW Wash
- Version: 1.0
- DMX Channels: 3CH, 4CH, 6CH, 8CH, 11CH
- Power: 10W per LED
- Control: DMX512
- Color Mixing: RGBW
Product Usage Instructions
Safety Instructions
- Ensure the device is mounted securely on a stable platform.
- Use appropriate mounting materials as specified in the manual.
Installation
- Attach the safety catch rope and hook securely.
- Use the quick-release fastener for easy installation.
- Tighten the M10 screw and self-locking nut firmly.
DMX512 Control
Use a DMX controller to program different lighting effects.
Operation
- The device can be operated in standalone mode or controlled via a DMX controller.
- Adjust settings such as DMX address, dimmer channels, and color presets as needed.
Master/Slave Mode
In Master/Slave mode, the device can function as a master without an external controller or as a slave with an external controller.
Color Settings
Select from various pre-set color combinations for different lighting effects.
FAQ
Q: How do I reset the device to factory settings?
A: To reset to factory settings, refer to the user manual for specific instructions.
Q: Can I use this product outdoors?
A: This product is suitable for outdoor use but ensure it is protected from direct exposure to water.
eurolite®
Multiflood IP 8x10W RGBW Wash
Flüsterleiser IP65-LED-Fluter mit RGBW-Farbmischung, Diffusorscheibe,
Flügelbegrenzer und IR-Fernbedienung Silent IP65 LED floodlight with RGBW
color mixing, diffuser cover, barn doors and IR remote control
No. 41606250
www.eurolite.de
Multiflood IP 8x10W RGBW Wash
DANGER! Electric shock caused by short-circuit
Be careful with your operations. With a dangerous voltage you can suffer a
dangerous electric shock when touching the wires. Never open the housing.
Please read these instructions carefully before using the product. They contain important information for the correct use of the product.
Every person involved with the installation, operation and maintenance of this device has to
- be qualified
- follow the instructions of this manual
- consider this manual to be part of the total product
- keep this manual for the entire service life of the product
- pass this manual on to every further owner or user of the product
- download the latest version of the user manual from the Internet
INTRODUCTION
Thank you for having chosen one of our products. If you follow the instructions given in this manual, we are sure that you will enjoy this device for a long period of time.
Product features
Silent IP65 LED floodlight with RGBW color mixing, diffuser cover, barn doors, IR remote control
- Additional frost filter provides a wide, soft and homogeneous light
- 4 barn doors to avoid blinding the audience and for protection during transport
- 8 powerful LEDs 10 W high-power 4in1 QCL RGBW (homogenous color mix)
- Color blend stepless; color change adjustable; color fade adjustable; dimmer electronic; Dimmer speed (step response) with adjustable response; white balance
- Strobe effect
- 36 integrated show programs
- The device is cooled by passive convection cooling
- Control via stand-alone; DMX; master/slave function; IR remote control; RDM
- 3 buttons on the remote control for saving your own color mixes
- Preprogrammed in Light Captain; LED PC-Control 512
- With a beam angle of 10°
- With mounting bracket; with Omega bracket
- OLED display
- Mains input and output for power linking up to 8 units
- Suitable for outdoor use IP65
- With pressure compensation membrane
- With a KENSINGTON LOCK theft protection
- For application areas such as: Stage; architecture
- Silent operation
- Flicker-free
Package contents
- 1 x device, 1 x user manual, 1 x power cord, 1 x remote control, 1 x diffusor cover, 1 x Omega bracket, 1 x barndoor
SAFETY INSTRUCTIONS
WARNING!
Please read the safety warnings carefully and only use the product as
described in this manual to avoid accidental injury or damage.
Intended use
- This product is designed to light indoor and outdoor areas and is IP65 rated. It can be mounted and operated in indoor and outdoor areas and is not dimmable. This device is designed for professional use in the field of event technology, e.g. on stage. It is not suitable for household lighting.
- Only use the device according to the instructions given. Damages due to failure to follow these operating instructions will void the warranty! We do not assume any liability for any resulting damage.
- We do not assume any liability for material and personal damage caused by improper use or non-compliance with the safety instructions. In such cases, the warranty will be null and void.
- Unauthorized rebuilds or modifications of the device are not permitted for reasons of safety and render the warranty invalid.
Danger due to electricity
- To reduce the risk of electric shock, do not open any part of the device. There are no serviceable parts inside the device.
- Only connect the device to a properly installed mains outlet. The outlet must be protected by residual current breaker (RCD). The voltage and frequency must exactly be the same as stated on the device. If the mains cable is equipped with an earthing contact, then it must be connected to an outlet with a protective ground. Never deactivate the protective ground of a mains cable. Failure to do so could possibly injure the user.
- For outdoor use make sure to connect a rubber cable H05RN-F or H05RR-F. For installations in the ground an underground power cable NYY must be used. All valid instructions concerning the installation of cables outdoors or in the ground must be adhered to.
- The mains outlet must be easily accessible so that you can unplug the device quickly if need be.
- Never touch the mains plug with wet or damp hands. There is the risk of potentially fatal electric shock.
- The mains cable must not be bent or squeezed. Keep it away from hot surfaces or sharp edges.
- Never pull the mains cable to disconnect the mains plug from the mains outlet, always seize the plug.
- Unplug the device during lightning storms, when unused for long periods of time or before cleaning.
- Do not expose the device to any high temperatures, direct sunlight, strong vibrations or heavy mechanical stress.
- Do not immerse the product in water, this will destroy it. Furthermore, this could cause a lethal electric shock!
- Only have repairs to the device or its mains cable carried out by qualified service personnel. Repairs are required when the device or the mains cable is visibly damaged, when the device has been dropped or malfunctions occur.
Danger to children and people with restricted abilities
- This product is not a toy. Keep it out of the reach of children and pets. Do not leave packaging material lying around carelessly. Never leave this device running unattended.
- This device may be used only by persons with sufficient physical, sensorial, and intellectual abilities and having corresponding knowledge and experience. Other persons may use this device only if they are supervised or instructed by a person who is responsible for their safety.
Warning – risk of burns and fire
- The admissible ambient temperature range (Ta) is -5 to +45°C. Do not operate the device outside of this temperature range.
- The housing temperature (Tc) can be up to 70°C during use. Avoid contact by persons and materials.
- Do not illuminate surfaces within 10 cm of the device. This value is indicated on the device by the symbol.
- Do not use the device near highly flammable materials. Always place the device at a location where sufficient air circulation is ensured. Leave 50 cm of free space around the device. Never cover the air vents of the housing.
Warning – risk of injuries
- Do not look directly at the light source. Persons with light-sensitive epilepsy may suffer from epileptic seizures or fall unconscious.
- Make sure that the product is set up or installed safely and expertly and prevented from falling down. Comply with the standards and rules that apply in your country, in particular EN 60598-2-17.
- If you lack the qualification, do not attempt the installation yourself, but instead use a professional installer. Improper installation can result in bodily injury and or damage to property.
- The manufacturer cannot be made liable for damages caused by incorrect installations or insufficient safety precautions.
- For overhead use, always secure the device with a secondary safety attachment such as a safety bond or safety net.
- Make sure that the area below the installation place is blocked when rigging, derigging or servicing the device.
- For commercial use the country-specific accident prevention regulations of the government safety organization for electrical facilities must be complied with at all times.
Caution – material damage
- This device must not be connected to the mains voltage by means of a dimmer.
- Lighting effects are not designed for permanent operation. Consistent operation breaks will ensure that the device will serve you for a long time without defects.
- Never switch the device on and off at short intervals. This will considerably reduce the service life of the device.
- If the device has been exposed to drastic temperature fluctuation, do not switch it on immediately. The resulting condensation may destroy the device. Allow the device to reach room temperature before connecting it. Wait until the condensation has evaporated.
- Please use the original packaging to protect the device against vibration and dust during transportation or storage.
- If a serial number label is affixed to the device, do not remove the label as this would make the warranty void.
About batteries
- Do not try to short-circuit, recharge, disassemble or heat batteries (danger of explosion!).
- Remove the batteries if the device is not used for a longer period of time.
- Damaged/leaking batteries may cause harm to your skin–use safety gloves.
DESCRIPTION OF THE DEVICE
- Folding latch for the frost filter/ barndoors
- Lens/LED
- Infrared sensor for the remote control
- Mounting bracket
- Fixation lever
- Kensington security slot
- Cooling ribs
- Carrying handle
- Display/Control Board with operating buttons
- Power output
- Power input
- 3-pin DMX output
- Pressure compensation membrane
- 3-pin DMX input
- Locking plate for the Omega bracket
- Rubber foot
Note: When connected correctly, the power and DMX sockets are protected from spraying water according to IP65. When not in use, make absolutely sure to close the sockets with the rubber sealing caps.
INSTALLATION
WARNING! Risk of injury caused by falling objects
Devices in overhead installations may cause severe injuries when crashing
down. Make sure that the device is installed securely and cannot fall down.
The installation must be carried out by a specialist who is familiar with the
hazards and the relevant regulations.
The device may be placed on the floor or fastened to a truss or similar rigging structure. The device must never be fixed swinging freely in the room.
- The rigging structure must support at least 10 times the weight of all fixtures to be installed on it.
- Block access below the work area and work from a stable platform when installing the device.
- Use rigging hardware that is compatible with the structure and capable of bearing the weight of the device. Please refer to the “Accessories” section for a list of suitable rigging hardware. Screw a clamp via a M10 screw and self-locking nut onto the Omega bracket. Insert the two quick-lock fasteners of the Omega bracket into the respective holes on the bottom of the device. Tighten the quick-lock fasteners fully clockwise.
- Secure the device with a safety bond or other secondary attachment. This secondary safety attachment must be sufficiently dimensioned in accordance with the latest industrial safety regulations and constructed in a way that no part of the installation can fall down if the main attachment fails. Use the hole in the bracket for fixation of the safety bond. Fasten the safety bond in such a way that, in the event of a fall, the maximum drop distance of the device will not exceed 20 cm.
- To align the device, release the fixation levers at the mounting bracket, adjust the desired inclination angle and tighten the fixation levers.
- After installation, the device requires inspections periodically to prevent the possibility of corrosion, deformation and looseness.
Changing the beam angle
With the delivery of the device you will receive a frost filter, with which
the beam angle can be changed from 10° to approx. 25°. If present, please
remove the protective foil of the frost filter when using it for the first
time. If you want to change the beam angle of the device, attach the filter
using the folding latch on the front of the device. Make sure that the frost
filter is firmly attached to avoid accidental loosening of the frost filter.
DMX512 CONTROL
A DMX512 data link is required in order to control the device via DMX. The device provides special DMX connectors, which are designed according to protection class IP65. Matching DMX connection cables with special plugs are optionally available. When not in use, make absolutely sure to close the connections with the rubber sealing caps to prevent moisture and dirt from penetrating.
- Connect the output of your DMX controller to the DMX input DMX IN of the device with a DMX cable.
- Connect the DMX output DMX OUT of the device to the DMX input of the next unit in the chain. Always connect one output to the input of the next unit until all units are connected.
- At the last unit, the DMX cable has to be terminated. Plug the terminator with a 120 Ω resistor between Signal (–) and Signal (+) in the DMX output of the last unit.
- If the cable length exceeds 300 m or the number of DMX devices is greater than 32, it is recommended to insert a DMX level amplifier to ensure proper data transmission.
XLR connection
POWER SUPPLY
The device uses an auto-range power supply that accepts input voltages between 100 und 240 volts. The power connectors are designed according to protection class IP65. Matching connection cables with special plugs are optionally available. When not in use, make absolutely sure to close the connections with the rubber sealing caps to prevent moisture and dirt from penetrating.
- Connect the device via the mains cable to a grounded mains socket. Thus the unit is switched on.
- To switch off the unit, disconnect the power plug.
- Do not connect the unit to the mains voltage via a dimmer. For a more convenient operation, use a mains outlet which is switchable.
- The jack POWER OUT allows for power supply of further devices. To interconnect several devices, connect the jack POWER OUT to the input POWER IN of the next unit until all units are connected.
Matching power cables are available as accessories. In this manner, up to 8 devices can be linked at 230/240 input voltage and up to 4 devices at 110/115 input voltage.
OPERATION
After connecting the device to the mains it is ready for operation. The display indicates the last operating mode. The operating modes can be selected by means of the display and the control buttons. All settings remain stored even if the device is disconnected from the mains. The device can be operated in stand-alone mode via the control board and controlled via remote control (EUROLITE IR-38) and DMX signal.
Stand-alone mode
In the stand-alone mode, you can do without a controller. Disconnect the
device from the controller and call the desired setting. Please refer to the
instructions under Control Board.
Interconnecting several devices (master/slave operation)
Several devices may be interconnected (max. 32). Then all slave units can be
synchronized and controlled with the master unit without the need for a DMX
controller. The devices must be set to the corresponding operating modes.
- Configure all slave units before connecting the master unit: Press the MENU button so many times until “MASTSLAV” is indicated on the display. Confirm with the ENTER button. Set “Slave” on all slave units with the UP and DOWN buttons. Confirm with the ENTER button. Set “Master” on the master unit using the UP and DOWN buttons. Confirm with the ENTER button.
- Connect the DMX output of the master unit to the DMX input of the first slave unit. Then connect the DMX output of the first slave unit to the DMX input of the second slave unit, etc. until all units have been connected in a chain. Make sure the master unit is the first in the chain. Do not connect a DMX controller to the DMX input of the master unit.
- Set the master unit to the desired operating mode. The interconnected devices will now operate synchronously.
Control Board
The Control Board offers several features: you can easily set the starting
address, run the pre-programmed program or select a DMX channel mode.
The main menu is accessed by pressing Menu. Browse through the menu by
pressing Up or Down. Press Enter in order to select the desired menu. You can
change the selection by pressing Up or Down. Press Enter in order to confirm.
You can leave every mode by pressing Menu. The functions provided are listed
in the following sections.
If you press and hold Up or Down, the values change faster. The device has an
automatic storage for all settings. When you switch the device off and on
again, it will operate with the previously set values.
Default settings in bold
MAIN level | Menu level | Description |
---|---|---|
DMX Addr | 001- 512 | DMX address setting |
DMX Chan
| 3CH, 4CH, 6CH,
8CH, 11CH
| ****
Setting DMX channel mode
Dimmer
| ****
OFF/ Dim1/Dim2/ Dim3/Dim4
| Dimmer speed (step response)
OFF: Response characteristics of LEDs
Dim1: Response characteristics of halogen lamps, fast Dim2: Response characteristics of halogen lamps, less fast Dim3: Response characteristics of halogen lamps, middle
Dim4: Response characteristics of halogen lamps, slow
Mast/Slav
| ****
Master/ Slave
| Master/Slave mode
(Master :control without external controller) (Slave: control with external controller)
Color Set
| Dimmer intensity of the LED colors /
stepless RGBW color mixture 000 – 255 (increasing)
---|---
Red – 000 – 255| Dimmer intensity red
Green – 000 – 255| Dimmer intensity green
Blue – 000 – 255| Dimmer intensity blue
White – 000 – 255| Dimmer intensity white
Col Mac
| ****
R (01) –
R+G+B+W (15)
| Preset colors
Col Progr
| ****
Black – MW
| Internal programs / blackout| Black| Blackout| BD| Blue
Dark
---|---|---|---
Pty 1| Red Green Blue| BY| Blue Yellow
Pty 2| Cyan Magenta Yellow| BC| Blue Cyan
Pty 3| Red Green Blue Cyan Magenta Yellow| BM| Blue Magenta
Pty 4| Red Green Blue White| BW| Blue White
Rbw
| Rainbow Red, Yellow, Green, Cyan, Blue, Magenta| ****
WD
| ****
White Dark
RD| Red Dark| WY| White Yellow
RG| Red Green| WC| White Cyan
RB| Red Blue| WM| White Magenta
RY| Red Yellow| YD| Yellow Dark
RC| Red Cyan| YC| Yellow Cyan
RM| Red Magenta| YM| Yellow Magenta
RW| Red White| YW| Yellow White
GD| Green Dark| CD| Cyan Dark
GB| Green Blue| CM| Cyan Magenta
GY| Green Yellow| CW| Cyan White
GC| Green Cyan| MD| Magenta Dark
GM| Green Magenta| MW| Magenta White
GW| Green White|
Jump/Fade 000 – 255
| Jump (000 – 255)
Switching colors with increasing speed; Fade (000 – 255)
Fading colors with increasing speed
White Bal
| Red – 125 – 255| ****
White balance
Default setting: RGBW = 255
Green – 125 – 255
Blue – 125 – 255
White – 125 – 255
DMX Fail
| ****
Hold Col Mac White Blackout
| Behavior in case of missing DMX signal Hold: holds the last received signal,
Col Mac: pre-selected preset color,
White: all LEDs 100% on,
Black out : LEDs go off
Sys Info| Temperat xxC| Internal temperature of
the device
---|---|---
Version Ver. x.x| Software version
Dis Perm
| ****
ON/ OFF/Lock
| Display shutoff/key lock ON: display does not shut off
OFF: shuts off the display after 30 seconds – press the Menu button to reactivate the display.
Lock: shuts off the display permanently after 30 seconds and
activates the key lock (display indication: key lock activated) – press the Menu key for 4 seconds to deactivate the key lock again.
Fix Hours
| ****
(**) h**
| ****
Indication of operating hours
UID
| ****
UID:29AA04 **
| RDM UID 1)
Factory-set RDM code for unique identification
Def.Set
| ****
YES/NO
| ****
Reset to factory settings
1 RDM UID
This device supports RDM (Remote Device Management), which makes remote control of devices connected to the DMX bus possible. ANSI E1.20-2006 by ESTA specifies the RDM standard as an extension of the DMX512 protocol. RDM simplifies device configuration as manual settings like adjusting the DMX starting address are no longer needed. RDM is integrated in DMX without influencing the connections. The RDM data is transmitted via the standard XLR pins 1 and 2 – new DMX cables are not necessary. RDM-ready and conventional DMX devices can be operated in one DMX line. The RDM protocol sends own packages in the DMX512 data feed and does not influence conventional devices. DMX splitters, however, must support RDM. Which parameters can be called up via RDM depends on the RDM controller used.
EUROLITE IR-38 remote control
The IR remote control has the following functions:
Notes
- When actuating a button, always direct the remote control towards the sensor. There must be no obstacles between remote control and the sensor.
- The remote control is supplied with a battery inserted. An insulating foil between the battery and the battery contacts prevents the battery from being discharged during storage. Prior to the first operation remove the foil from the battery support on the rear side of the remote control. Otherwise operation of the remote control is not possible.
- If the range of the remote control decreases, replace the battery. For this purpose, on the rear side of the remote control press the small bar with the groove to the right and at the same time remove the battery support. For operation, one 3 V button cell type CR 2032 is required. When inserting, pay attention that the positive pole of the button cell shows upwards in the support.
- Remove the battery from the remote control as a precaution if the device is not used for a longer period of time.
DMX operation
Setting the number of DMX channels and the DMX starting address
For operation with a controller with DMX512 protocol, the device is equipped
with 11 control channels. However, it can also be switched to a mode with 3,
4, 6 or 8 channels, if different functions are required. To be able to operate
the device with a DMX controller, the device must be set to “Slave” in the
Control Board. In addition, the DMX starting address must be set. The starting
address depends upon which DMX controller is being used. Please refer to the
controller’s documentation.
- Press the MENU button so many times until MASTSLAV is indicated on the display. Confirm with the ENTER button. Set Slave with the UP and DOWN buttons. Confirm with the ENTER button.
- Press the MENU button so many times until “DMX Chan“ is indicated on the display. Confirm with the ENTER button.
- The display indicates 6 CH (6 DMX channels) or 3 CH (3 DMX channels), 4 CH (4 DMX channels), 8 CH (8 DMX channels) or 11 CH (11 DMX channels). Use the buttons UP and DOWN to select the desired DMX channel mode. Confirm with the ENTER button.
- Press the button MENU in order to return to the main menu.
- Press the MENU button so many times until “DMX Addr“ is indicated on the display. Confirm with the ENTER button.
- Use the buttons UP and DOWN to set the address. Confirm with the ENTER button.
- Press the button MENU in order to return to the main menu.
- When receiving DMX control signals, is indicated on the display.
Note: Please make sure that you do not have any overlapping channels in order to control each device correctly and independently from any other fixture on the DMX chain. If several devices are addressed to the same address, they will work synchronously.
DMX Protocol
3 channel mode
Channel | Value | Feature |
---|---|---|
1 | 0-255 | Red, Green and Blue color mixing |
2 | 0-255 | White , 0 – 100 % increasing |
3 | 0-255 | Dimmer , 0 – 100 % increasing |
4 channel mode
Channel | Value | Feature |
---|---|---|
1 | 0-255 | Red , 0 – 100 % increasing |
2 | 0-255 | Green , 0 – 100 % increasing |
3 | 0-255 | Blue , 0 – 100 % increasing |
4 | 0-255 | White , 0 – 100 % increasing |
6 channel mode
Channel | Value | Feature |
---|---|---|
1 | 0-255 | Red , 0 – 100 % increasing |
2 | 0-255 | Green , 0 – 100 % increasing |
3 | 0-255 | Blue , 0 – 100 % increasing |
4 | 0-255 | White , 0 – 100 % increasing |
5 | 0-255 | Dimmer , dimmer intensity from 0 to 100 % |
Strobe | ||
6 | 0-14 | LEDs on |
15-255 | Strobe effect with increasing speed |
8 channel mode
Channel | Value | Feature |
---|---|---|
1 | 0-255 | Dimmer , dimmer intensity from 0 to 100 % |
2 | 0-255 | Red , 0 – 100 % increasing |
3 | 0-255 | Green , 0 – 100 % increasing |
4 | 0-255 | Blue , 0 – 100 % increasing |
5 | 0-255 | White , 0 – 100 % increasing |
6 | 0-14 | LEDs on |
15-255 | Strobe effect with increasing speed | |
Fading in/out | ||
0-31 | Neutral | |
32-63 | Fade in (0 % – 100 %) (effect depending on the control |
channels 1 – 5)
| 64-95| Fade out (100 % – 0 %) (effect depending on the control
channels 1 – 5)
7| 96-127| Fade out and fade in (100 % – 0 % – 100
%) (effect depending on the
control channels 1 – 5)
| 128-159| Program “Fading”
| 160-191| Program “Fade out – Fade in”
| 192-223| Program “Switching”
| 224-255| Blackout
8| 0-255| Speed Fading in/out and programs
channel 7
increasing speed
11 channel mode
Channel | Value | Feature |
---|---|---|
1 | 0-255 | Dimmer , dimmer intensity from 0 to 100 % |
2 | 0-255 | Red , 0 – 100 % increasing |
3 | 0-255 | Green , 0 – 100 % increasing |
4 | 0-255 | Blue , 0 – 100 % increasing |
5 | 0-255 | White , 0 – 100 % increasing |
6 | 0-14 | LEDs on |
15-255 | Strobe effect with increasing speed | |
Fading in/out | ||
0-31 | Neutral | |
32-63 | Fade in (0 % – 100 %) (effect depending on the control |
channels 1 – 5)
| 64-95| Fade out (100 % – 0 %) (effect depending on the control
channels 1 – 5)
7| 96-127| Fade out and fade in (100 % – 0 % – 100
%) (effect depending on the
control channels 1 – 5)
| 128-159| Program “Fading”
| 160-191| Program “Fade out – Fade in”
| 192-223| Program “Switching”
| 224-255| Blackout
8| 0-255| Speed Fading in/out and programs
channel 7
increasing speed
| | Internal programs
---|---|---
| 0-3| Black – Blackout (no internal program)
| 4-10| Pty 1 – Red Green Blue
| 11-17| Pty 2 – Cyan Magenta Yellow
| 18-24| Pty 3 – Red Green Blue Cyan Magenta Yellow
| 25-31| Pty 4 – Red Green Blue White
| 32-38| Rbw – Rainbow Red, Yellow, Green, Cyan, Blue, Magenta
| 39-45| RD – Red Dark
| 46-52| RG – Red Green
| 53-59| RB – Red Blue
| 60-66| RY – Red Yellow
| 67-73| RC – Red Cyan
| 74-80| RM – Red Magenta
| 81-87| RW – Red White
| 88-94| GD – Green Dark
| 95-101| GB – Green Blue
| 102-108| GY – Green Yellow
| 109-115| GC – Green Cyan
11| 116-122| GM – Green Magenta
| 123-129| GW – Green White
| 130-136| BD – Blue Dark
| 137-143| BY – Blue Yellow
| 144-150| BC – Blue Cyan
| 151-157| BM – Blue Magenta
| 158-164| BW – Blue White
| 165-171| WD – White Dark
| 172-178| WY – White Yellow
| 179-185| WC – White Cyan
| 186-192| WM – White Magenta
| 193-199| YD – Yellow Dark
| 200-206| YC – Yellow Cyan
| 207-213| YM – Yellow Magenta
| 214-220| YW – Yellow White
| 221-227| CD – Cyan Dark
| 228-234| CM – Cyan Magenta
| 235-241| CW – Cyan White
| 242-248| MD – Magenta Dark
| 249-255| MW – Magenta White
CLEANING AND MAINTENANCE
The outside of the device should be cleaned periodically to remove contaminants such as dust etc. The lens, in particular, should be clean to ensure that light will be emitted at maximum brightness.
- Disconnect the device from power and allow it to cool before cleaning.
- Clean the surface with a soft lint-free and moistened cloth. Never use alcohol or solvents as these may damage the surface. Make sure that no liquids can enter the device.
- The device must be dry before reapplying power.
There are no serviceable parts inside. Do not open the housing. Do not try to repair the device by yourself as this may result in damage. Maintenance and service operations are only to be carried out by authorized dealers. Should you need any spare parts, please use genuine parts. Should you have further questions, please contact your dealer.
PROTECTING THE ENVIRONMENT
Disposal of old equipment
When to be definitively put out of operation, take the product to a local
recycling plant for a disposal which is not harmful to the environment.
Devices marked with this symbol must not be disposed of as household waste.
Contact your retailer or local authorities for more information. Remove any
inserted batteries and dispose of them separately from the product.
You as the end user are required by law (Battery Ordinance) to return all used
batteries/ rechargeable batteries. Disposing of them in the household waste is
prohibited. You may return your used batteries free of charge to collection
points in your municipality and anywhere where batteries/rechargeable
batteries are sold. By disposing of used devices and batteries correctly, you
contribute to the protection of the environment.
TECHNICAL SPECIFICATIONS
Power supply: | 100-240 V AC, 50/60 Hz |
---|---|
Power consumption: | 80 W |
IP classification: | IP65 |
Protection class: | Protection class I |
Power connection: | Mains input via IP T-Con (M) mounting version, power supply |
cord with safety plug (provided)
Power output:| IP T-Con (F) mounting version
Lamp type:| LED lamp
LED:| 8 x 10 W high-power 4in1 QCL RGBW (homogenous color mix)
Flash rate:| 1 – 23 Hz
DMX channels:| 3; 4; 6; 8; 11
DMX input:| 3-pin XLR (M) mounting version IP
DMX output:| 3-pin XLR (F) mounting version IP
Cooling:| Passive convection cooling
Control:| Stand-alone; DMX; Master/slave function; IR remote control; RDM
Preprogrammed in:| Light Captain; LED PC-Control 512
Beam angle (1/2 peak):| 10°
Frost filter 25°
Beam angle (1/10 peak):| 25°
Frost filter 55°
Housing color:| Black
Attachment system:| Mounting bracket
Omega bracket
Display type:| OLED display
Theft protection:| KENSINGTON LOCK
Dimensions:
| Length: 31.9 cm
Width: 14 cm
Height: 24.8 cm
Weight:| 6.4 kg
Noise classification:| Class 0 (no noise at all)
Remote control|
---|---
Battery:| 1 x Button cell 3.0 V CR2032 lithium manganese built-in
Accessories
EUROLITE TH-250 Quick-Lock Coupler silver | No. 58000760 |
---|---|
EUROLITE Safety Bond AG-15 4x1000mm up to 15kg | No. 58010364 |
EUROLITE Omega bracket 50 | No. 51786568 |
EUROLITE Diffuser Cover 40° for Multiflood IP 8x10W RGBW | No. 41606251 |
EUROLITE Diffuser Cover 60×10° for Multiflood IP 8x10W RGBW | No. 41606252 |
EUROLITE Diffuser Cover 80° for Multiflood IP 8x10W RGBW | No. 41606253 |
EUROLITE IP T-Con Power Cable 3×1.5 1,5m | No. 30235005 |
EUROLITE IP T-Con Connection Cable 3×1.5 5m | No. 30247758 |
EUROLITE DMX cable EC-1 IP65 3pin 5m bk | No. 30227873 |
EUROLITE IR-38 Remote Control | No. 50530601 |
ROADINGER Flightcase 4x Multiflood IP 8x10W RGBW Wash | No. 31005239 |
EUROLITE IP XLR plug/socket 5pin | No. 30208439 |
All information is subject to change without prior notice. © 29.11.2023
Eurolite is a brand of Steinigke Showtechnic GmbH Andreas-Bauer-Str. 5 97297 Waldbüttelbrunn Germany D00151597 Version 1.0 Publ. 29/11/2023
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>