INTRODUCTION
Thank you for having chosen a EUROLITE SB-1200B power distributor. If you
follow the instructions given in this manual, we are sure that you will enjoy
this device for a long period of time.
Unpack your SB-1200B.
Before you initially start-up, please make sure that there are no transport
damages. Should there be any, do not take the device into operation and
immediately consult your dealer.
SAFETY INSTRUCTIONS
CAUTION!
Be careful with your operations. With a dangerous voltage you can suffer a
dangerous electric shock when touching the wires!
This device has left our premises in absolutely perfect condition. In order to
maintain this condition and to ensure a safe operation, it is absolutely
necessary for the user to follow the safety instructions and warning notes
written in this user manual.
Important:
Damages caused by the disregard of this user manual are not subject to
warranty. The dealer will not accept liability for any resulting defects or
problems.
If the device has been exposed to drastic temperature fluctuation (e.g. after
transportation), do not switch it on immediately. The arising condensation
water might damage your device. Leave the device switched off until it has
reached room temperature.
Please make sure that there are no obvious transport damages. Should you
notice any damages on the A/C connection cable or on the casing, do not take
the device into operation and immediately consult your local dealer.
This device falls under protection-class I. The CEE plug must only be plugged
into a CEE outlet. The voltage and frequency must exactly be the same as
stated on the device. Wrong voltages or power outlets can lead to the
destruction of the device and to mortal electrical shock.
Always plug in the power supply CEE plug last. The power plug must always be
inserted without force. Make sure that the plug is tightly connected with the
outlet.
Never let the power-cord come into contact with other cables! Handle the
power-cord and all connections with the mains with particular caution! Never
touch them with wet hands, as this could lead to mortal electrical shock.
Never modify, bend, strain mechanically, put pressure on, pull or heat up the
power cord. Never operate next to sources of heat or cold. Disregard can lead
to power cord damages, fire or mortal electrical shock.
The cable insert or the female part in the device must never be strained.
There must always be sufficient cable to the device. Otherwise, the cable may
be damaged which may lead to mortal damage.
Make sure that the power-cord is never crimped or damaged by sharp edges.
Check the device and the power-cord from time to time.
If extension cords are used, make sure that the core diameter is sufficient
for the required power consumption of the device. All warnings concerning the
power cords are also valid for possible extension cords.
Always disconnect from the mains, when the device is not in use or before
cleaning it. Only handle the power-cord by the plug. Never pull out the plug
by tugging the power- cord. Otherwise, the cable or plug can be damaged
leading to mortal electrical shock. If the power plug or the power switch is
not accessible, the device must be disconnected via the mains.
If the power plug or the device is dusty, the device must be taken out of
operation, disconnected and then be cleaned with a dry cloth. Dust can reduce
the insulation which may lead to mortal electrical shock. More severe dirt in
and at the device should only be removed by a specialist.
There must never enter any liquid into power outlets, extension cords or any
holes in the housing of the device. If you suppose that also a minimal amount
of liquid may have entered the device, it must immediately be disconnected.
This is also valid, if the device was exposed to high humidity. Also if the
device is still running, the device must be checked by a specialist if the
liquid has reduced any insulation. Reduced insulation can cause mortal
electrical shock.
There must never be any objects entering into the device. This is especially
valid for metal parts. If any metal parts like staples or coarse metal chips
enter into the device, the device must be taken out of operation and
disconnected immediately. Malfunction or short-circuits caused by metal parts
may cause mortal injuries.
The total weight of the installation (=total weight of all individual parts)
must never exceed the maximum load of the installation area.
Keep away children and amateurs!
Never leave this device running unattended.
OPERATING DETERMINATIONS
This device is a power distributor for supplying current to other devices.
This product is only allowed to be operated with an alternating voltage of
380-400 V, 50 Hz and was designed for indoor use only.
This device is designed for mobile use and for permanent installations.
The maximum power consumption of this device must never be exceeded.
When choosing the installation-spot, please make sure that the device is not
exposed to extreme heat, moisture or dust. There should not be any cables
lying around. You endanger your own and the safety of others!
This device must never be operated or stockpiled in surroundings where splash
water, rain, moisture or fog may harm the device. Moisture or very high
humidity can reduce the insulation and lead to mortal electrical shocks. When
using smoke machines, make sure that the device is never exposed to the direct
smoke jet and is installed in a distance of 0.5 meters between smoke machine
and device.
The ambient temperature must always be between -5° C and +45° C. Keep away
from direct insulation (particularly in cars) and heaters.
The relative humidity must not exceed 50 % with an ambient temperature of 45°
C.
This device must only be operated in an altitude between -20 and 2000 m over
NN.
The ambient contamination must never exceed level 1 and must not be
conducting, only dry.
Never use the device during thunderstorms. Over voltage could destroy the
device. Always disconnect the device during thunderstorms.
Make sure that the area below the installation place is blocked when rigging,
derigging or servicing the fixture.
Operate the device only after having familiarized with its functions. Do not
permit operation by persons not qualified for operating the device. Most
damages are the result of unprofessional operation!
Never use solvents or aggressive detergents in order to clean the device!
Rather use a soft and damp cloth.
Please use the original packaging if the device is to be transported.
Inspection deadlines according to DGUV-V3 for electrical resources must be
complied with.
Please consider that unauthorized modifications on the device are forbidden
due to safety reasons!
If this device will be operated in any way different to the one described in
this manual, the product may suffer damages and the guarantee becomes void.
Furthermore, any other operation may lead to dangers like shortcircuit,
burns, electric shock, crash etc.
WEEE Directive When to be definitively put out of operation, take the unit(s)
to a local recycling plant for a disposal which is not harmful to the
environment. Do not dispose of as municipal waste. Contact your retailer or
local authorities for more information.
DESCRIPTION
4.1 Product features
Practical 63A distributor in 19″ housing
- Specially designed for larger distribution needs
- 3U necessary for installation
- 63A three-phase current input via 1 meter long 5×16 mm² power cable and plug
- The entire distributor is secured via Type B 63A/0,03A 4-pol fault current circuit breaker
- 2 x 32A three-phase current outputs via mounted sockets, each individually secured on the back panel by a 3-pole 32A circuit breaker
- 2 x 16A three-phase current outputs via mounted sockets, each individually secured on the back panel by a 3-pole 16A circuit breaker
- Control lamps indicate each phase
- With earthing screw in order to ground a rig if necessary
4.2 Device view 1
-
19″ housing
-
16A three-phase current outputs
-
32A three-phase current outputs
-
63A three-phase current input
4.3 Device view 2
-
Phase control lamps
-
Fault-current circuit breaker
-
3-pole 32A circuit breaker
-
3-pole 16A circuit breaker
INSTALLATION
DANGER TO LIFE!
Please consider the DIN 15560 and the respective national norms during the
installation! The installation must only be carried out by an authorized
dealer!
The operator has to make sure that safety-relating and machine-technical
installations are approved by an expert before taking into operation for the
first time and after changes before taking into operation another time.
The operator has to make sure that safety-relating and machine-technical
installations are approved by an expert after every four year in the course of
an acceptance test.
The operator has to make sure that safety-relating and machine-technical
installations are approved by a skilled person once a year.
Procedure:
The installation should be attached outside areas where persons may walk by or
be seated.
5.1 Rack installation
This power distributor is built for 19“ racks / steel cabinet (483 mm). The
rack you use should be a double-door-rack where you can open the front panel
and the rear panel. The rack should be provided with a cooling fan. When
mounting the power distributor into the rack, please make sure that there is
enough space around the device so that the heated air can be passed on.
Steady overheating will damage your device.
You can fix the power distributor with four M6 screws in the rack.
Be careful when mounting the power distributor into the rack. Put the heaviest
devices into the lower part of the rack. 5.2 Connections
5.2.1 Connection with the mains
Connect the device to the mains with the CEE plug.
The earth has to be connected!
If the device will be directly connected with the local power supply network,
a disconnection switch with a minimum opening of 3 mm at every pole has to be
included in the permanent electrical installation.
5.2.2 Outputs
Connect your loads via the output sockets. Please note that the maximum
current must never be exceeded.
DANGER TO LIFE!
Before taking into operation for the first time, the installation has to be
approved by an expert!
CLEANING AND MAINTENANCE
The operator has to make sure that safety-relating and machine-technical
installations are inspected by an expert after every four years in the course
of an acceptance test.
The operator has to make sure that safety-relating and machine-technical
installations are inspected by a skilled person once a year.
The following points have to be considered during the inspection:
- All screws used for installing the devices or parts of the device have to be tightly connected and must not be corroded.
- The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or sediments. Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety problems have to be removed.
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!
We recommend a frequent cleaning of the device. Please use a moist, lint-free
cloth. Never use alcohol or solvents!
There are no serviceable parts inside the device. Maintenance and service
operations are only to be carried out by authorized dealers.
Should you need any spare parts, please use genuine parts.
The examination intervals for mobile electrical devices (German DGUV-V3) must
be kept.
The operator has to make sure that the electrical devices are examined by an
electrician before taking into operation for the first time and after changes
before taking into operation another time.
Electrical devices must only be taken into operation in a perfect condition
and must be kept this way.
For keeping the perfect condition, electrical devices must repeatedly be
approved in accordance with the instructions given in the electro-technical
guidelines.
A qualified electrician is responsible for the correct examinations.
Mobile electrical devices, extension cords with plugs, power cables with plugs
and mobile cables with plugs and permanent installation must be approved by an
expert every three months.
Should you have further questions, please contact your dealer.
TECHNICAL SPECIFICATIONS
Power supply: | 380-400V AC, 50Hz |
---|---|
Power connection: | Fixed power supply cord with CEE 63A 5-pin |
Cable construction: | 5 x 16 mm2 HO5RN-F |
Cable length: | 1 m |
Power output: | 2 x CEE 32A 5-pol (F) recessed mounting fused |
2 x CEE 16A 5-pol (F) recessed mounting fused
Protection:| 1 x fault-current circuit breaker (FI) Type B 63A/0,03A 4-pol
2 x circuit breaker C 16A 3-pol
2 x circuit breaker C 32A 3-pol
Phase status display:| 3
Housing design:| (19″) 48.3 cm rack installation 3 U
Dimensions:| Width: 48.3 cm
Depth: 31 cm
Height: 13.35 cm
Weight:| 8.00 kg