| CAUTION!
Keep this device away from rain and moisture! Never open the housing!
---|---
For your own safety, please read this user manual carefully before you initially start-up.
Every person involved with the installation, operation and maintenance of this
device has to
– be qualified
– follow the instructions of this manual
– consider this manual to be part of the total product
– keep this manual for the entire service life of the product
– pass this manual on to every further owner or user of the product
– download the latest version of the user manual from the Internet
INTRODUCTION
Thank you for having chosen a EUROLITE LED PAR-64 RGB Floor/Short. If you follow the instructions given in this manual, we are sure that you will enjoy this device for a long period of time.
Unpack your LED PAR-64 RGB Floor/Short.
SAFETY INSTRUCTIONS
| CAUTION!
Be careful with your operations. With a dangerous voltage you can suffer a
dangerous electric shock when touching the wires!
---|---
This device has left our premises in absolutely perfect condition. In order to maintain this condition and to ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual.
Important:
Damages caused by the disregard of this user manual are not subject to
warranty. The dealer will not accept liability for any resulting defects or
problems.
If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on immediately. The arising condensation water might damage your device. Leave the device switched off until it has reached room temperature.
Please make sure that there are no obvious transport damages. Should you notice any damages on the A/C connection cable or on the casing, do not take the device into operation and immediately consult your local dealer.
This device falls under protection-class I. The power plug must only be
plugged into a protection class I outlet. The voltage and frequency must
exactly be the same as stated on the device. Wrong voltages or power outlets
can lead to the destruction of the device and to mortal electrical shock.
Always plug in the power plug last. The power plug must always be inserted
without force. Make sure that the plug is tightly connected with the outlet.
Never let the power-cord come into contact with other cables! Handle the
power-cord and all connections with the mains with particular caution! Never
touch them with wet hands, as this could lead to mortal electrical shock.
Never modify, bend, strain mechanically, put pressure on, pull or heat up the
power cord. Never operate next to sources of heat or cold. Disregard can lead
to power cord damages, fire or mortal electrical shock.
The cable insert or the female part in the device must never be strained.
There must always be sufficient cable to the device. Otherwise, the cable may
be damaged which may lead to mortal damage.
Make sure that the power-cord is never crimped or damaged by sharp edges.
Check the device and the power-cord from time to time.
If extension cords are used, make sure that the core diameter is sufficient
for the required power consumption of the device. All warnings concerning the
power cords are also valid for possible extension cords.
Always disconnect from the mains, when the device is not in use or before
cleaning it. Only handle the power-cord by the plug. Never pull out the plug
by tugging the power-cord. Otherwise, the cable or plug can be damaged leading
to mortal electrical shock. If the power plug or the power switch is not
accessible, the device must be disconnected via the mains.
If the power plug or the device is dusty, the device must be taken out of
operation, disconnected and then be cleaned with a dry cloth. Dust can reduce
the insulation which may lead to mortal electrical shock. More severe dirt in
and at the device should only be removed by a specialist.
There must never enter any liquid into power outlets, extension cords or any
holes in the housing of the device. If you suppose that also a minimal amount
of liquid may have entered the device, it must immediately be disconnected.
This is also valid, if the device was exposed to high humidity. Also if the
device is still running, the device must be checked by a specialist if the
liquid has reduced any insulation. Reduced insulation can cause mortal
electrical shock.
There must never be any objects entering into the device. This is especially
valid for metal parts. If any metal parts like staples or coarse metal chips
enter into the device, the device must be taken out of operation and
disconnected immediately. Malfunction or short-circuits caused by metal parts
may cause mortal injuries.
During the initial start-up some smoke or smell may arise. This is a normal
process and does not necessarily mean that the device is defective.
| HEALTH HAZARD!
Never look directly into the light source, as sensitive persons may suffer an
epileptic shock (especially meant for epileptics)!
---|---
Keep away children and amateurs!
Never leave this device running unattended.
OPERATING DETERMINATIONS
This device is a lighting effect for creating decorative effects. This product
is only allowed to be operated with an alternating voltage of 230 V, 50 Hz and
was designed for indoor use only.
This device is designed for professional use, e.g. on stages, in discotheques,
theatres etc.
Lighting effects are not designed for permanent operation. Consistent
operation breaks will ensure that the device will serve you for a long time
without defects.
Do not shake the device. Avoid brute force when installing or operating the
device.
When choosing the installation-spot, please make sure that the device is not
exposed to extreme heat, moisture or dust. There should not be any cables
lying around. You endanger your own and the safety of others!
This device must never be operated or stockpiled in sourroundings where splash
water, rain, moisture or fog may harm the device. Moisture or very high
humidity can reduce the insulation and lead to mortal electrical shocks. When
using smoke machines, make sure that the device is never exposed to the direct
smoke jet and is installed in a distance of 0.5 meters between smoke machine
and device. The room must only be saturated with an amount of smoke that the
visibility will always be more than 10 meters.
The ambient temperature must always be between -5° C and +45° C. Keep away
from direct insulation (particularly in cars) and heaters.
The relative humidity must not exceed 50 % with an ambient temperature of 45°
C.
This device must only be operated in an altitude between -20 and 2000 m over
NN.
Never use the device during thunderstorms. Over voltage could destroy the
device. Always disconnect the device during thunderstorms.
The symbol determines the minimum distance from lighted objects. The minimum
distance between light-output and the illuminated surface must be more than
0.1 meters.
This device is only allowed for an installation via the mounting bracket. In
order to safeguard sufficient ventilation, leave 50 cm of free space around
the device.
The housing must never touch surrounding surfaces or objects.
Make sure that the area below the installation place is blocked when rigging,
derigging or servicing the fixture.
Always fix the fixture with an appropriate safety bond.
The maximum ambient temperature Ta = 45° C must never be exceeded. Operate the
device only after having become familiarized with its functions. Do not permit
operation by persons not qualified for operating the device. Most damages are
the result of unprofessional operation!
Never use solvents or aggressive detergents in order to clean the device!
Rather use a soft and damp cloth.
Please use the original packaging if the device is to be transported. Make
sure that you pack the device in the original state.
Please consider that unauthorized modifications on the device are forbidden
due to safety reasons!
Never remove the serial barcode from the device as this would make the
guarantee void.
If this device will be operated in any way different to the one described in
this manual, the product may suffer damages and the guarantee becomes void.
Furthermore, any other operation may lead to dangers like shortcircuit, burns,
electric shock, crash etc.
DESCRIPTION
Features
Professional spot as LED RGB DMX model!
Operable in stand-alone mode or via DMX • DMX512 control possible via any
commercial DMX controller (occupies 5 channels) • 3 or 5 DMX channels
selectable for numerous applications • Sound-control via builtin microphone •
Comfortable addressing and setting via control panel with LED display and four
operating buttons • Functions: Static colors, RGB color blend, 6 internal
programs, dimmer and strobe settings via DMX, Master/Slave • Equipped with 183
10 mm LEDs • Beam angle approximately 10° • Locking possibility at the
mounting bracket • Ready for connection via power cord with safety plug •
Available as hanging spot or as floor spot • Silver or black housing
available.
INSTALLATION
The floor device can be installed on the ground or on the wall or ceiling.
Overhead rigging
| DANGER TO LIFE!
Please consider the EN 60598-2-17and the respective national standards during
the installation!
The installation must only be carried out by an authorized dealer!
---|---
The installation of the device has to be built and constructed in a way that
it can hold 10 times the weight for 1 hour without any harming deformation.
The installation must always be secured with a secondary safety attachment,
e.g. an appropriate catch net. This secondary safety attachment must be
constructed in a way that no part of the installation can fall down if the
main attachment fails.
When rigging, derigging or servicing the fixture staying in the area below the
installation place, on bridges, under high working places and other endangered
areas is forbidden.
The operator has to make sure that safety-relating and machine-technical
installations are approved by an expert before taking into operation for the
first time and after changes before taking into operation another time.
The operator has to make sure that safety-relating and machine-technical
installations are approved by an expert after every four year in the course of
an acceptance test.
The operator has to make sure that safety-relating and machine-technical
installations are approved by a skilled person once a year.
Procedure:
The device should be installed outside areas where persons may walk by or be
seated.
IMPORTANT! OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE, including (but not
limited to) calculating working load limits, installation material being used,
and periodic safety inspection of all installation material and the device. If
you lack these qualifications, do not attempt the installation yourself, but
instead use a professional structural rigger. Improper installation can result
in bodily injury and.or damage to property.
The device has to be installed out of the reach of people.
If the device shall be lowered from the ceiling or high joists, professional
trussing systems have to be used.
The device must never be fixed swinging freely in the room.
Caution: Devices may cause severe injuries when crashing down! If you
have doubts concerning the safety of a possible installation, do NOT install
the device!
Before rigging make sure that the installation area can hold a minimum point load of 10 times the device’s weight.
| DANGER OF FIRE!
When installing the device, make sure there is no highly inflammable material
(decoration articles, etc.) within a distance of min. 0.5 m.
---|---
Mount the device with the mounting-bracket to your trussing system using an appropriate clamp.
For overhead use, always install an appropriate safety bond.
You must only use safety bonds and quick links complying with DIN 56927,
shackles complying with DIN EN 1677-1 and BGV C1 carbines. The safety bonds,
quick links, shackles and the carbines must be sufficiently dimensioned and
used correctly in accordance with the latest industrial safety regulations (e.
g. BGV C1, BGI 810-3).
Please note: for overhead rigging in public or industrial areas, a series
of safety instructions have to be followed that this manual can only give in
part. The operator must therefore inform himself on the current safety
instructions and consider them.
The manufacturer cannot be made liable for damages caused by incorrect
installations or insufficient safety precautions!
Pull the safety bond through the hole in the mounting-bracket and over the
trussing system or a safe fixation spot. Insert the end in the quick link and
tighten the safety screw.
The maximum drop distance must never exceed 20 cm.
A safety bond which already held the strain of a crash or which is defective
must not be used again.
Adjust the desired inclination-angle via the mounting-bracket and tighten the
fixation screws.
| DANGER TO LIFE!
Before taking into operation for the first time, the installation has to be
approved by an expert!
---|---
DMX512 control
| The wires must not come into contact with each other, otherwise the devices
will not work at all, or will not work properly.|
---|---|---
| Please note, the starting address depends upon which controller is being
used|
---|---|---
Only use a DMX cable and 3-pin XLR plugs and connectors in order to connect the controller with the fixture or one fixture with another
Occupation of the XLR connection:
DMX-output
XLR mounting-socket| DMX-input
XLR mounting-plug
---|---
|
If you are using controllers with this occupation, you can connect the DMX output of the controller directly with the DMX input of the first device in the DMX chain. If you wish to connect DMX controllers with other XLR outputs, you need to use adapter cables.
Building a serial DMX chain:
Connect the DMX output of the first device in the DMX chain with the DMX input
of the next device. Always connect one output with the input of the next
device until all devices are connected.
Caution: At the last fixture, the DMX cable has to be terminated. Plug the terminator with a 120 Ω resistor between Signal (–) and Signal (+) in the DMX output of the last fixture.
Master/Slave-Operation
The master/slave-operation enables that several devices can be synchronized
and controlled by one masterdevice.
On the rear panel of the EUROLITE LED PAR-Spot you can find an XLR jack and an XLR-plug, which can be used for connecting several devices.
Choose the device which is to control the effects. This device then works as master-device and controls all other slave-devices, which are to be connected to the master-device via a stereo shielded cable. Connect the OUT-jack with the IN-plug of the next device.
Set the Master device to one of the stand alone modes (“C—” or “P—“) and set each Slave device to the same DMX address “d001”.
Connection with the mains
Connect the device to the mains with the power-plug.
The occupation of the connection-cables is as follows:
Cable | Pin | International |
---|---|---|
Brown | Live |
L
Blue| Neutral|
N
Yellow/Green| Earth|
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IECstandards. The electric installation must be equippedwith a Residual Current Device (RCD) with a maximum fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.
OPERATION
After you connected the spot to the mains, the EUROLITE LED PAR-64RGB Floor/Short starts running.
The LED display lights up and you can choose the desired settings.
This unit has two operating modes: it can be run as a stand-alone unit without external control via LED display with operating buttons or alternately in DMX- controlled mode via lighting controller.
Control Board
The Control Board offers several features: you can run the internal programs or set the starting address.
Browse through the menu by pressing the Mode button. Press the Enter button in order to select the desired submenu. You can change the selection by pressing the Up or Down buttons. Press Enter in order to confirm your selection. You can leave every mode by pressing Mode. The functions provided are described in the following sections.
– STAND ALONE-MODE
• Setting Solid Colors
• Internal Programs, Sound Control
– DMX MODE
STAND ALONE-MODE
In Stand Alone Mode, the LED PAR-64 RGB Floor/Short can be used without a controller.
Disconnect the LED PAR-64 RGB Floor/Short from the controller.
Setting Solid Colors
Press the MODE button to select the solid color mode. When the display shows C, you can select the desired solid color via the UP or DOWN buttons (see following graphic)
Mode: | Value: | Function: |
---|---|---|
C | C01 | Red |
C02 | Green | |
C03 | Blue | |
C04 | Cyan | |
C05 | Purple | |
C06 | Yellow | |
C07 | White |
Internal Programs, Sound Control
Press the MODE button to select the internal program mode. When the display shows P, you can select the desired internal program, with or without sound control, via the UP or DOWN buttons (see following graphic
Mode: | Value: | Function: |
---|---|---|
P | P1 | Endless loop in 7 colors, change every 3 seconds |
P2 | Endless loop in 7 colors, fade every 3 seconds | |
P3 | Endless loop in 3 colors, change every 3 seconds | |
P4 | Endless loop in 3 colors, fade every 3 seconds | |
P5 | Endless loop in 7 colors, via sound control | |
P6 | Endless loop in 3 colors, via sound control |
Setting the Sound Sensitivity:
You can do without a controller as the device features a built-in microphone, which provides automatic sound control.
Manual adjustements via display as follows:
Mode:
| Value:|
Sensitivity:
---|---|---
S
| S00-S99|
Decreasing sensitivity
You can select the desired sensitivity via the UP or DOWN buttons.
DMX MODE
The Control Board allows you to assign the DMX fixture address, which is defined as the first channel from which the LED PAR-64 RGB Floor/Short will respond to the controller.
Addressing
Press the MODE button until the display shows ADD. You can now set the desired address via the UP or DOWN buttons.
Setting the DMX Start Address:
Mode:
| Value:
---|---
ADD|
001 – 512
Controlling:
After having addressed the LED PAR-64 RGB Floor/Short, you may now start
operating it via your lighting controller.
Note:
The modes of DMX 512 data are shown via the DMX indicator.
After switching on, the device will automatically detect whether DMX 512 data
is received or not. If the data is received, a point will blink in the first
position on the display.
If there is no data received at the DMX-input, the point will not blink.
This situation can occur if:
– the 3 PIN XLR plug (cable with DMX signal from controller) is not connected
with the input of the device.
– the controller is switched off or defective,
– the cable or connector is defective or the signal wires are not properly
connected with the input connector.
Choosing a DMX Channel Mode with 3 or 5 Channel Occupation
The device has 2 DMX-modes. The Control Board allows you to assign the DMX- Mode.
Setting DMX Mode
After setting the desired address via the UP or DOWN buttons, press the MODE
button again and the display shows CHND
You can now set the desired DMX Channel Mode via the UP or DOWN buttons.
Mode: | Value: |
---|---|
CHND | 5ch (default setting) |
3ch
DMX-protocol
5 Channel Mode
Channel: | Value: | Function: |
---|---|---|
CH1 | 000 – 255 | Red (0 – 100%) |
Channel: | Value: | Function: |
--- | --- | --- |
CH2 | 000 – 255 | Green (0 – 100%) |
Channel: | Value: | Function: |
--- | --- | --- |
CH3 | 000 – 255 | Blue (0 – 100%) |
Channel: | Value: | Function: |
--- | --- | --- |
CH4 | 000 – 255 | Dimmer (0 – 100%) |
Channel: | Value: | Function: |
--- | --- | --- |
CH5
| 000 – 000| ON
001 – 005| Sound Control (7 colors)
006 – 010| ON
011 – 255| Strobe (increasing)
3 Channel Mode
Channel: | Value: | Function: |
---|---|---|
CH1 | 000 – 255 | Red (0 – 100%) |
Channel: | Value: | Function: |
--- | --- | --- |
CH2 | 000 – 255 | Green (0 – 100%) |
Channel: | Value: | Function: |
--- | --- | --- |
CH3 | 000 – 255 | Blue (0 – 100%) |
CLEANING AND MAINTENANCE
|
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!
---|---
We recommend a frequent cleaning of the device. Please use a soft lint-free and moistened cloth. Never use alcohol or solvents!
There are no serviceable parts inside the device except for the fuse. Maintenance and service operations are only to be carried out by authorized dealers.
Replacing the fuse
If the fine-wire fuse of the device fuses, only replace the fuse by a fuse of same type and rating.
Before replacing the fuse, unplug mains lead.
Procedure:
Step 1: Unscrew the fuseholder with a fitting screwdriver from the
housing (anti-clockwise).
Step 2: Remove the old fuse from the fuseholder.
Step 3: Install the new fuse in the fuseholder.
Step 4: Replace the fuseholder in the housing and fix it.
Should you need any spare parts, please use genuine parts.
If the power supply cable of this device becomes damaged, it has to be replaced by authorized dealers only in order to avoid hazards.
Should you have further questions, please contact your dealer.
TECHNICAL SPECIFICATIONS
Power supply: | 230 V AC, 50 Hz ~ |
---|---|
Power consumption: | 20 W |
Number of channels: | 3/5 |
DMX512 connection: | 3-pin XLR |
Sound-control: | via built-in microphone |
Maximum ambient temperature T a: | 45° C |
Maximum housing temperature T C: | 65° C |
Min. distance from flammable surfaces: | 0.5 m |
Min. distance to lighted object: | 0.1 m |
Fuse: | F 1 A, 250V |
LED type: | 10 mm |
Number of LEDs: | 182 |
Beam angle: | 10° |
Dimensions (LxWxH): | 280 x 265 x 320 mm |
Weight: | 1.5 kg |
Accessories: | No. |
--- | --- |
EUROLITE TH-50 Theatre hook, silver | 58000650 |
EUROLITE TH-50S Theatre hook, black | 58000651 |
Safety bond A 3x600mm up to 5kg, silver | 58010310 |
EUROLITE DMX LED Operator 1 | 70064501 |
EUROLITE DMX LED Operator 4 | 70064504 |
Please note: All information is subject to change without prior notice. 02.06.2015 ©