Wired, non-programmable thermostat, battery powered (2xAAA) or 230V AC powered. It is used for wired control of heating or cooling devices and systems. It works by maintaining comfortable conditions in the room, in line with the setpoint temperature set by the user. It is connected directly to a heat source or wiring centre. For a better fit, the model is available in two colors. Safe, reliable, easy to use.

Product Compliance
This product complies with the following EU Directives: 2014/53/EU, 2011/65/EU

Technical Informations

Power supply 230V or 2xAAA batteries
Max current 3 (1) A
Temperature range 5 – 35°C
Display temperature accuracy 0,1°C
Control algorithm TPI or Hysteresis (±0.2°C to ±2°C)
Communication Wired
Output control COM / NO (voltage-free)
IP protection class IP30
Dimension [mm] 80 x 80 x 22 mm

Connection description for EASY230W / EASY230B

a) Connection diagram for gas boiler| ENGO EASY230W Wired Thermostat -
Connection diagram 1
---|---
b) Connection diagram to pump / actuator| ENGO EASY230W Wired Thermostat -
Connection diagram 2
c) Connection diagram to the control box| ENGO EASY230W Wired Thermostat -
Connection diagram 3

Connection description for EASYBATW / EASYBATB

a) Connection diagram for gas boiler| ENGO EASY230W Wired Thermostat -
Connection diagram 4
---|---
b) Connection diagram to pump / actuator| ENGO EASY230W Wired Thermostat -
Connection diagram 5
c) Connection diagram to the control box| ENGO EASY230W Wired Thermostat -
Connection diagram 6

Legend:

**Boiler – Boiler connection* – Boiler’s contacts for ON/OFF thermostat (according to the boiler’s instructions)
Pump
Valve
L, N – power supply
COM, NO – voltage-free output
SL1** – 230V control input in the control box
– fuse

Description of the LCD display + description of the buttonsENGO
EASY230W Wired Thermostat - Description of the LCD
display

  1. Current / set room temperature
  2. Temperature unit
  3. Heating mode icon
  4. Cooling mode icon

Proper thermostat location

For the thermostat to work properly, it must be installed in a suitable place. Preferably approx. 150 cm above floor level, away from sources of heat or cold. In addition, the thermostat should not be installed behind curtains or other obstacles or in places with high humidity, as this will prevent an accurate measurement of the temperature in the room. It is not recommended to install the thermostat on an outside wall, in a draft or in a place where it will be exposed to direct sunlight.

Lock / Unlock the thermostat’s keys

To lock the keys on the thermostat, press and hold simultaneously and  buttons for 7 seconds. After the screen appears, release the keys. Thermostat is locked.
To unlock the keys on the thermostat, press and hold simultaneously and buttons for 7 seconds. After the screen appears, release the keys. Thermostat is unlocked.

Installer parameters

WARNING!
After entering the service menu, use or buttons to choose parameter.
For the parameter selection to be confirmed, wait 3 seconds.
The screen will appear with the settings that you can change with  or buttons.
Wait 3 seconds for the selection to be confirmed.
The thermostat will go to the home screen.

ENGO EASY230W Wired Thermostat - Installer parameters