  • Never dispose of this equipment with household waste. Electrical and electronic products contain substances that can be harmful to the environment if not properly handled. The crossed-out waste bin symbol indicates separate collection of electrical devices, which must be separated from other urban waste. For correct environmental management, at the end of its useful life the equipment should be taken to the collection centers provided for this purpose.
  • The parts that make it up can be recycled. Therefore, please respect the regulations in force regarding environmental protection.
  • If you replace the equipment, the original equipment must be returned to your dealer or deposited at a specialized collection center.
  • Violations are subject to the penalties and measures stipulated in environmental protection law.

Before Starting

  • The system must be installed by a qualified technician.
  • This product must not be modified or disassembled under any circumstances.
  • Do not handle the system with wet or damp hands.
  • In the case of any malfunction of this appliance, do not repair it yourself. Contact the sales distributor or service dealer for repair or disposal of the product.
  • Check that the HVAC installation has been installed according to the manufacturer’s requirements, complies with local regulations in force and is working correctly before you install the Airzone system.
  • Place and connect the elements in your installation in accordance with current regulations covering electrical installations.
  • All connections must be made with the power supply completely turned off.
  • Take care not to short circuit any of the system’s connections.
  • Please refer carefully to the wiring diagram and these instructions when wiring.
  • Connect all wiring securely. Loose wiring may cause overheating at the connection points and is a possible fire hazard.
  • Do not locate the Airzone communication bus close to power lines, fluorescent lights, actuators, etc. as this may cause interference in communications.
  • The connection to the external power supply must include a main switch or other method of disconnection that includes a constant separation for all polarities, in accordance with appropriate local and national regulations. The system will automatically restart if the power supply is turned off. Use separate circuits for the unit that is to be controlled and the power supply to the system.AIRZONE AZAI6ZWEDA0 Aidoo AC to Z-Wave Controller - Fig 1
  • Check the polarity of each device’s connectors. A wrong connection can seriously damage the product.
  • To connect to the system, use Airzone cable: four-wire cable (2×0.22 mm twisted shielded wires for data communications and 2×0.5 mm2 wires for power supply).
  • For equipment using R32 refrigerant, verify the compliance with the local refrigerant regulation.

Aidoo Z-Wave PlusTM by Airzone

Device to manage and integrate units remotely. Wireless Z-WaveTM connection. Externally powered by the indoor unit.
Features:

  • Control of the parameters of the unit.
  • Communication errors detection.
  • Temperature and operating mode time schedules.
  • Port for integration via Modbus .

For further information about our products, go to airzonecontrol.com
The Aidoo Z-Wave PlusTM by Airzone operates in any Z-Wave network with other Z-Wave/ZWave PlusTM certified devices and controllers from any other manufacturer. As a constantly powered node, Aidoo Z-Wave Plus will act as repeater in order to increase the reliability of the network.

DEVICE ELEMENTS

AIRZONE AZAI6ZWEDA0 Aidoo AC to Z-Wave Controller - DEVICE
ELEMENTS

Description
1 Cable for connection with indoor unit
2 Modbus port
3 Indoor unit port
4 Device reboot
5 Association process
6 Factory reset

TECHNICAL SPECS

Connection to indoor unit

V max.| 18 Vdc
I max.| 137.5 mA
V in| 12-16 Vdc
Consumption| 310 mW
Type of cable| According to the indoor unit manufacturer
Wire length| 2.5 m (8.2 ft)
Z-Wave Communication
Protocol| Z-Wave Plus
Model| ZGM130S
Communication frequency| AZAI6ZWxXXX
E = Europe (E.U.)
U = United States (U.S.)
H = Australia / New Zealand (ANZ)
E= 864.4 MHz (E.U.)
U= 908.4 MHz, 916 MHz (U.S.)
H= 919.8 MHz, 921.4 MHz (AZN)
Maximum power-Antenna
powe| 13 dBm
Sensitivity| -97 dBm
Protection system| S2 Security
Maximum distance| Up to 100 m outdoor
Up to 40 m indoor
Modbus Port
Shielded twisted pair| 2 x 0.22 + 2 x 0.5 mm2
(AWG 23 – 2 wired +
AWG 20 – 2 wired)
Shielded twisted pair| MODBUS RS-485 Par – 19200 bps
Operating temperatures
Storage| -20 … 70 ºC (-4 … 158 ºF)
Operation| 0 … 45 ºC (32 … 113 ºF)
  Operating humidity rango| 5 … 90% (non-condensing)
Mechanical aspects
Protection class| IP 41
Weight| 130 g (0.29 lb)
Size (WxHxD)| 92x80x29 mm (3.62×3.15×1.14”)
Conformity
Europe| – 2011/65/EU & 2015/863/EU & 2017/2102/UE – RoHS Directive
– 2014/53/EU – RED (Radio Equipment Directive)
U.S.A / Canada| – 47 CFR Part 15B – FCC
– ICES-003 Issue 6 – ISED
Australia / New Zeland| – AS/NZS 4268-2017 – SRD Standard

ASSEMBLY AND CONNECTION

ASSEMBLY
Perform the assembly by fixing your Aidoo Z-Wave Plus close to the AC unit to be controlled using the material supplied:
a. Screw attachment.
b. Double-sided adhesive attachment. AIRZONE AZAI6ZWEDA0 Aidoo AC to Z-Wave
Controller - ASSEMBLY

CONNECTION
General considerations to connect the Aidoo Z-Wave Plus:

  1. Important: Some Aidoo Z-Wave Plus requires to be supplied by a limited power source meeting class PS2 of the standard IEC 62368-1. Refer to the data sheet the for further information.
  2. Important: Use separate circuits for the unit that is to be controlled and the power supply to the system.AIRZONE AZAI6ZWEDA0 Aidoo AC to Z-Wave Controller - CONNECTION
  3. Disconnect the indoor unit. Perform all of the connections with a total absence of power.
  4. Connect the Aidoo Z-Wave Plus to the indoor unit according to the instructions detailed in the data sheet of your specific Aidoo Z-Wave Plus reference.
  5. Power the indoor unit. Check the LEDs (see Self-diagnosis section).
  6. Configure the device.

AIRZONE AZAI6ZWEDA0 Aidoo AC to Z-Wave Controller - CONNECTION
1

SELF-DIAGNOSIS
The Aidoo Z-Wave Plus have integrated LED that detects the operation of the device.
Depending on the LED operation, it indicates:

AIRZONE AZAI6ZWEDA0 Aidoo AC to Z-Wave Controller -
DIAGNOSIS

|

Meaning

---|---
| Connected to Z-Wave network| Steady| Blue
| TX/RX communication with Z-Wave| Blinking| Red
Linking device| Steady| Red
Identification mode| Fast Blinking| Red
| Microprocessor activity| Blinking| Green
| Power supply| Steady| Red
| Data transmission to the indoor unit| Blinking| Red
| Data reception from the indoor unit| Blinking| Green

CONFIGURATION

ADD/REMOVE AIDOO Z-WAVE PLUS INTO A Z-WAVE NETWORK (CLASSIC)

The Aidoo Z-Wave Plus is compatible with all Z-Wave/Z-Wave Plus certified controllers. The device supports both the Network Wide Inclusion mechanism (which offers the ability to be included in a network, even if the device is not directly connected to the controller) and Normal Inclusion.
By default, the inclusion procedure starts in Normal Inclusion mode and after a short timeout the procedure continues in Network Wide Inclusion mode that lasts for about 20 Seconds.
Standard Inclusion
The Aidoo Z-Wave Plus is compatible with all Z-Wave/Z-Wave Plus certified controllers. The device supports both the Network SmartStart inclusion mechanism (which offers the ability to be included in a network, even if the device is not directly connected to the controller) and Standard Inclusion.
By default, the inclusion procedure starts in Normal Inclusion mode and after a short timeout the procedure continues in Network Wide Inclusion mode that lasts for about 20 Seconds.
If the Aidoo Z-Wave Plus has not been included yet into the Z-Wave network, the LED will remain off. The procedure of inclusion is activated by pressing the Association Button . As soon as the inclusion procedure initiates, the ** LED remains steady red until the device is included in the network.
Standard exclusion
Only a controller can remove the device from the network. After activating the exclusion function by the controller, the device can be removed by setting it in Learning Mode.
If the Aidoo Z-Wave Plus is already included into the Z-Wave network, the LED will remain steady blue. The procedure of exclusion is activated by pressing the Association Button . As soon as the exclusion procedure initiates, the LED remains steady red until the device is excluded of the network.
SMARTSTART INCLUSION**
Z-Wave SmartStart aims to shift the tasks related to inclusion of an Aidoo Z-Wave Plus into a Z-Wave network away f rom the Aidoo device itself, and towards the more user-f riendly interface of the gateway.
Z-Wave SmartStart removes the need for initiating the Aidoo device to start inclusion. Inclusion is initiated automatically on power-ON, and repeated at dynamic intervals for as long as the device is not included into a Z-Wave network. As the new device announces itself on power-ON, the protocol will provide notifications, and the gateway can initiate the inclusion process in the background, without the need for user interaction or any interruption of normal operation. The Smart Start inclusion process only includes authenticated devices.

The Aidoo Z-Wave Plus can be added into a Z-Wave network by scanning the Z-Wave QR Code present on the product with a controller providing SmartStart inclusion. No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network vicinity.
The SmartStart QR and the full DSK string code can be found on the front side of the Aidoo Z-Wave Plus. The PIN is the first group of 5 underlined digits of the DSK identified as DSK in the left side of the sticker. If you plan to use the DSK, it is important that you take a picture of the label and keep it in a safe place.AIRZONE AZAI6ZWEDA0 Aidoo AC to Z-Wave Controller - network
vicinity S2 SECURE INCLUSION
When adding the Aidoo Z-Wave Plus to a Z-Wave network with a controller supporting Security 2 Authenticated (S2), the PIN code of the Z-Wave Device Specific Key (DSK) is required. The first five digits of the unique DSK code are the key PIN code and is printed on the product label.

Z-WAVE COMMUNICATION

SUPPORTED COMMAND CLASSES

Command class Version Non-Secure CC Secure CC
BASIC 2 x
ZWAVEPLUS_INFO 2 x
ASSOCIATION 2 x
MULTI_CHANNEL_ASSOCIATION_V2 3 x
ASSOCIATION_GRP_INFO 3 x
TRANSPORT_SERVICE 2 x
VERSION 3 x
MANUFACTURER_SPECIFIC 2 x
DEVICE_RESET_LOCALLY 1 x
INDICATOR 3 x
POWERLEVEL 1 x
SECURITY 0 1 x
SECURITY_2 1 x
SUPERVISION 1 x
FIRMWARE_UPDATE_MD 5 x
THERMOSTAT_FAN_MODE 2 x
THERMOSTAT_MODE 3 x
THERMOSTAT_SETPOINT 1 x
SENSOR_MULTILEVEL 1 x
NOTIFICATION 8 x

Supporting command class basic
Implemented Mapping:

Basic Command Received Mapped Command (Thermostat Mode)
Basic set (0xxFF) If the last non Off mode was 1 or 2 -> Thermostat Mode(last

non Off mode). Otherwise -> Thermostat Mode (0x01)
Basic set (0xx00)| Thermostat Mode (0x00)
Basic GET| Replay with a basic Report with these meaning: Basic Report 0x00 if mode is equal to 0x00
If mode different than 0 reply with Basic Report 0xFF

The basic command classes are mapped into the Thermostat Mode Command Class as required by the protocol specification.
Supporting command class indicator
The Aidoo Z-Wave Plus supports Indicator V3 with Indicator ID 0x50 (identity). When the device receives an indicator set, the backlight  **start to blink accordingly the received command.
Notification Command Class
The system implement notification command class with Type: System (0x09) and event: System hardware failure (manufacturer proprietary failure code provided).
Manufacturer proprietary failure code provided are 2 bytes length (error and warning). The meaning of these bytes are described into the Air conditioning manufacturer’s installation manual.
Associations**
Lifeline group: Nodes belonging to this group will receive: notifications about device reset and all other changes.

Group Group
ID Name| N° of max nodes supported in the group| Description| Command sent
---|---|---|---
1   Lifeline| 1| Life Line Group| DEVICE_RESET_LOCALLY_NOTIFICATION THERMOSTAT_FAN_MODE_REPORT INDICATOR_REPORT THERMOSTAT_MODE_REPORT THERMOSTAT_SETPOINT_REPORT SENSOR_MULTILEVEL_REPORT NOTIFICATION_REPORT

DEVICE CONTROL. Z-WAVE APPLICATION COMMAND CLASS MAPPING

The Aidoo Z-Wave Plus controller acts as a gateway between the air conditioner controller interface and the Z-Wave network. The Aidoo Z-Wave Plus interacts with the proprietary protocol of the different A/C manufacturers converting the orders into Modbus commands to trigger the Z-Wave network commands.
The monitoring/control items supported by the Aidoo Z-Wave Plus are mapped to the standard Thermostat Command class object types defined by the Z-Wave protocol. The user can interact with the air conditioning system through the Z-Wave network with the following supported monitoring/control items.

Description Values Z-Wave Command
On/Off Off Thermostat_Mode
On Thermostat_Mode
SetPoint – SetpointType: (Heating, Cooling, Dry Air)
– SetPointValue: (tenths of °C) Thermostat_Setpoint
LocalTemp Room temperature x10 Sensor_Multilevel
Modes OFF

Auto chageover Cooling Heating
Fan
Dry| Thermostat_Mode
Speed| Auto – Medium Low
Medium High
Off| Thermostat_Fan_Mode
Warning| Max 2 Byte| Notification(*)
Error| Max 2 Byte

(*) For the Notification Z-Wave command class, the Aidoo Z-Wave Plus reserves 2 alphanumeric bytes to represent the Air conditioning unit warnings and error codes. The warnings and error codes are represented in a different way according to each manufacturer.
Please refer to the manufacturer’s installation manual to check the meaning of the different codes.
The following interactions with the air conditioning unit will imply a combination of Z-Wave. commands:

Description Values Z-Wave Command
Fan Off Off Thermostat_Fan_Mode Thermostat_Mode
Change Mode Thermostat_Mode: Auto chageover Cooling

Heating Fan Dry
Thermostat_Setpoint
– SetpointType: (Heating, Cooling, Dry Air)
– SetPointValue: (tenths of °C)| Thermostat_Mode Thermostat_Setpoint

It is possible to check the compatible Air conditioning indoor units in the Airzone compatibility checker: https://www.airzonecontrol.com/control_solutions/aidoo/wi-fi

RESET TO THE FACTORY SETTINGS
Please use this procedure only when the network primary controller is missing or ortherwise inoperable.
The Aidoo Z-Wave Plus can be reset to the original factory settings by long pressing over the Factoy Reset button until all of the front side LEDs light up for a second.
Note: If the reset is performed while the device is still part of a network, it notifies the other devices in the Lifeline group that it has been removed.

FIRMWARE UPDATE
The Aidoo Z-Wave Plus supports over-the-air firmware updates that do not require the device to be removed from its location. The firmware update can be activated from all certified controllers supporting version 5 of the Firmware Update function.
Important: The Aidoo Z-Wave Plus will be rebooted at the end of the firmware update
procedure. It is advisable to carry out the firmware update procedure only when necessary and following careful planning of the intervention.