namron 16A Thermostat Touch Zigbee Instruction Manual
- June 17, 2024
- NAMRON
Table of Contents
namron 16A Thermostat Touch Zigbee
Product Information
Specifications:
- Product Name: NAMRON THERMOSTAT TOUCH ZIGBEE 16A
- Operating Voltage: 220-240V~ 50/60Hz
- IP Rating: IP20
- LED Lamp: 5-200W
- Electronic Transformer/Halogen: 5-300W
- Halogen Lamp 240V: 5-300W
FAQ
- Q: Can I install the thermostat myself?
- A: Installation must be done by a qualified electrician for safety reasons.
Symbol Overview:
- Monitor set
- Off mode
- Manual mode
- Auto mode
- Away mode
- Weekdays
- Time/shift button
- Mode button
- Set temperature
- Other set
- Display Auto Off
- Up and down button
- Function button
- Settings Menu
How to Enter Settings Menu:
- Under Home Interface, meanwhile the device is at OFF mode, press and hold up and down buttons at the same time for over 5 seconds to enter Settings Menu.
- Short press move up and down button to select a settings item, then short press button F to enter selected item.
- Settings menu includes Preview menu, Zigbee settings, Schedule, Monitor settings, Time/Date settings, Other settings.
Time Setting:
Select TIME/DATE on Home Interface to enter into TIME/DATE SET interface.
Standby Interface:
If the device operation mode is set to any other mode except OFF Mode, and there is no operation within 2 minutes, the device will go to this standby interface.
Specifications
- Operating voltage: 220-240V~ 50/60Hz
- LED lamp: 5-200W
- Electronic transformer /halogen: 5-300W
- Halogen Lamp 240V: 5-300W
- Mounts in the standard electrical box or surface mounting
- Short-circuit protection
- Over load protection
- Over temperature protection
- Lamp breakdown protection
INSTALLATION
- Installation must be done by a qualified electrician.
- Power supply must be turned off during installation.
Wiring diagram
Mounting
- Remove the display unit and front cover by using a small screwdriver.
- Insert the wires to the correct terminals as presented in the wiring diagram above. Suggested wire-stripping length is 8-10mm.
- Fix the thermostat into the connection box by tightening the screws. Make sure that the thermostat is fixed without deformation. Suggested torque is 0.2-0.4Nm (2.0-4.1kgf.cm).
Symbol overview
Settings Menu
How to enter settings menu:
- Under Home Interface, meanwhile the device is at OFF mode , press and hold up and down buttons at the same time for over 5 seconds to enter Settings Menu.
- Short press move up and down button to select a settings item, then short press button F to enter selected item.
- Settings menu include, Preview menu, Zigbee settings, Schedule, Monitor settings, Time/Date settings, Other settings
Time Setting
Select TIME/DATE on Home Interface to enter into TIME/DATE SET interface as follow:
Short press button to select the item would like to modify, then short press
move up and move down buttons to modify value of selected item, then short
press button F to save and quit, short pressingbutton only quits without
saving.
The device Time Cluster is the client, if the bound device supports local time
of Time Cluster, the device will acquire local time from the bound device
spontaneously under 3 situations: acquire after this device is added to a
network, acquire when the device already added to a network and power is
reset, acquire every 24 hours
Standby Interface
If the device operation mode is set to any other mode except OFF Mode, and there is no operation within 2 minutes, the device will go to this standby interface. Once the device goes to standby interface, if the DisplayAuto Off function is enabled and there is no operation within 30 seconds, the display will go off automatically. If the device operation mode is set to OFF Mode, and there is no operation within 2 minutes, the display will go off automatically
Preview interface
On Home Interface, user can enter into PREVIEW interface, the interface will display some basic configurations, energy consumption, date, floor temperature etc.
Control Mode
Short press button on Home Interface to switch operation modes: the icons of Away, Auto, Manual, Drying, Off modes will be displayed alternatively for 3 seconds and last displayed mode will be selected, orjust short press F button to select a desired mode when the modes’ icon displayed alternatively. Press and hold button on Home interface for over 3 seconds to select Away mode directly, then Press and hold button for 3 seconds to quit Away mode.
Away Mode Schedule
User can set time to leave home and time to go home according to the requirements of themselves, and set how the device will control the temperature during this period.
- If away mode has already been activated, the end time for away mode is valid, the device will execute Away Mode Temperature Schedule before the end time.
- If away mode has already been activated, the values of end time for away mode are set as 0, the device will always execute current set temperature with no time limitation. The device will consider the mode as antifreeze mode, the recommended temperature setting is 4-10°C, and factory default setting is 6°C.
- D means date, M means month, Y means year (2019-2099). Start and end mean away time. To enter into the setting interface and setting method, please refer to the 1.4 Auto Mode (Energy Save Mode) Schedule
Auto Mode Schedule
When Auto Mode Schedule is valid, the device will control according to the set temperature of the schedule. For instance, if user would like to keep room temperature at 18 degrees Celsius during 18:00-23:00 on every Monday, and keep room temperature at 20 degrees Celsius after 22:30 on every Monday, then user can set schedule by himself. Schedule setting method 1: user can enters into ****schedule on System Setting Interface, the schedule interface is as follows
- Short press button to select “Auto Schedule”, then short press button to enter into Auto Mode Schedule weekly setting interface.
- Schedule setting method 2: on System Setting Interface, meanwhile the device is under Auto Mode , short press button to enter into Auto Mode Schedule weekly setting interface quickly:
- On Auto Mode Schedule weekly setting interface, use buttons and to enter into schedule setting of a certain week as follows:
- On Auto Day Schedule interface, short press button to select the time or temperature that you would like to modify, then short press move up and move down buttons to modify value, then short press button to save and quit, short pressing button only quits without saving.
- For each schedule, the latter time should be later than the former time, otherwise saving will fail with the error remind “Time setting error!!!”. The default time schedules are as follows:
Monday-Friday | 7:30,24C-12:00,20C | Saturday-Sunday | 7:30,24C-12:00,20C |
---|---|---|---|
18:00,16C-22:30,18C | 18:00,18C-22:30,18C |
Manual Mode
The device will control the heating system according to current set temperature. The temperature can be set by move up and move down button on the Home interface, or configured by Zigbee gateway.
Dry Mode Schedule
For example, in order to quickly dry the water on the floor of the bathroom, the device can be set to quickly heat in a short time to dry the floor. Enter the configuration interface as follows: Duration: set how long the dry mode lasts, can be configured through the proprietary attribute DryTime (0x1006) of Thermostat Cluster (0x0201), the configurable range is 5-100 minutes. After Mode: set the mode after the drying mode ends, can be configured through the proprietary attribute ModeAfter- Dry (0x1007) of Thermostat Cluster (0x0201).
Remain: shows the remaining time of the drying mode
For configuration method and modification, please refer to Automatic Mode (Energy Save Mode) Schedule
Off Mode
- This mode means that the device is under idle status.
Window Open Detect
Window Open Detect (disabled by default
Once the device is powered on and stable, referring to the room temperature sensor, if the temperature decreases to the threshold of this setting, the window open mark will be enabled, the relay will be forced to turn off to save energy, then the icon will appear. After window open mark is enabled, if the temperature increases to the threshold of this setting in 3 minutes,the window open mark will be disabled. Once the window open mark is enabled, it will bedisabled after 10 minutes, and the device will keep current working mode. This value can also be configured through the proprietary attribute Window Open Check (0x1009) of Thermostat Cluster (0x0201), 0 means this function is disabled. Note: this function will work better when the device is installed beside the window or door.
Zigbee Configuration Introduction
Select Network Set on Home Interface to enter into Zigbee network management interface as follow
Adding to a Zigbee Network
Operate your Zigbee gateway to add device, select “Add”, then short press button F , the device will search network and try to join, “Status” will show “Inclusion…”. If there is no response from a gateway, or adding failed, “Status” will show “Fail”. If added successfully, “Status” will show “Inclusion OK” and device ID.
Removing from a Zigbee Network
Operate your Zigbee gateway to remove device, Select “Remove”, then short press button F , the device will send out removing request, “Status” will show “Exclusion…”. If there is no response from a gateway, or removing failed, “Status” will show “Fail”. If removed successfully, “Status” will show “Exclusion OK” and device ID will be showed as 0. The device will be removed from the network and all parameters will be restored to factory default setting, all bindings will be cleared.
Factory Reset (Reset)
Factory resetting will remove the device from Zigbee network and all parameters will be restored to factory default setting, all bindings will be cleared. Select “Reset”, then short press button F , the device will start reset, “Status” will show “Reset…”. If exclusion failed, “Status” will show “Fail”. If reset successfully, “Status” will show “Reset OK”.
Configure Device Operation Mode through Zigbee
Since Zigbee does not have away mode, the attribute Occupancy (occupied or unoccupied) of Thermostat (0x0201) and attribute Occupancy of received Occupancy Sensing (0x0406) are required to judge whether it is away mode
-
if the device receives other devices’ or the gateway’s report: the Bit 0 of the value of attribute Occupancy (0x0000) of Occupancy ensing Cluster (0x0406) is 1, which means occupied, then the operation mode of the thermostat, the attribute System Mode(0x001c)=0x04(heat) of Thermostat (0x0201), meanwhile the value of attribute Occupancy (0x0002) of Thermostat (0x0201) is 0. It means the Away Mode is activated, and the thermostat UI will display.
if the gateway send command to modify the attribute System Mode(0x001c) of Thermostat (0x0201), the thermostat will quit Away Mode. Meanwhile the value of attribute Occupancy (0x0002) of Thermostat (0x0201) is 1. -
The proprietary attribute 0x2002(Manufacturer Code=0x1224) of the cluster 0x0201 can be modified to configure whether it is away mode or at home.
Note: Away Mode uses attribute Un Occupied Heating Set point to set temperature. Other modes uses attribute Occupied Heating Set point to set temperature.
Zigbee Interface
The thermostat provides 3 zigbee application endpoints
Endpoint | **Profile** | Applic ation |
---|---|---|
0(0x00) | 0x0000(ZDP) | ZigBee Device Object (ZDO) – standard management |
features
1(0x01)| 0x0104(HA)| Device ID is 0x0301(Thermostat ).
2(0x02)| 0x0104(HA)| Device ID is 0x0007(OTA).
242(0xF2)| 0xA1E0(GP)| Device ID is 0x0021(Green Power).
Application Endpoint #0 –ZigBee Device Object
- Application profile Id 0x0000
- Application device Id 0x0000
- Supports all mandatory clusters
Application Endpoint #1 –Thermostat
**Cluster** | supported | Description |
---|
0x0000
| ****
server
| Basic
Provides basic information about the device, such as the manufacturer ID, vendor and model name, stack profile, ZCL version, production date, hardware revision etc. Allows a factory reset of attributes, without the device leaving the network.
0x0003
| ****
server
| Identify
Allows to put the endpoint into identify mode. Useful for identifying/locating devices and required for Finding & Binding.
0x0004
| ****
server
| Groups
Allows adding this endpoint to one or more groups. Afterwards the endpoint can be addressed using the group address. This is also a prerequisite for scenes. You may also query group membership and delete group associations.
0x0005
| ****
server
| Scenes
Allows storing one or more scenes per group, where each scene consists of a pre-set on/off state value. You may either store the current values as a scene, or provide scene settings when adding a scene, or delete scenes.
Basic -0x0000 (Server)
Attributes supported
**Attribute** | T ype | Description |
---|---|---|
0x0000 | INT8U, read-only | ZCL Version |
0x03
0x0001
| INT8U, read-only| Applic ation V ersion
This is the firmware version number of the application
0x0002| INT8U, read-only| Stack Version
0x0003| INT8U, read-only| HW Version
Hardware version 1
0x0004| string, read-only| Manufacturer Name
“NAMRON AS”
0x0005| string, read-only| Model Identifier
“4512737 & 4512738”
0x0006| string, read-only| Date Code
NULL
0x0007
| ENUM8,read-only| Power Source
Device power supply, fixed value 0x01 Mains (single phase)
0x0008| ENUM8,read-only| Generic De vic e-Class
0XFF
0x0009| ENUM8,read-only| Generic De vic e – T ype
0XFF
0x000A| octstr read-only| Product Code
00
0x000B| string, read-only| Product URL
NULL
0x4000| string, read-only| Sw build id
6.9.1.0_r4
Command supported:
Command / Description
- 0x00 / Reset to Factory Defaults Command
- On receipt of this command, the device resets all the attributes of all its clusters to their factory defaults. Note that networking functionality, bindings, groups, or other persistent data are not affected by this command.
**Attribute** | Type | Description |
---|---|---|
0x0000 | int8u, read-only | Scene Count |
Holds the total number of scenes (across all groups) currently stored on the device.
0x0001| int8u, read-only| Current Scene
If the Scene Valid attribute is true, this attribute, together with the Current Group attribute, indicates the currently active scene.
0x0002| int16u, read-only| Current Group
If the Scene Valid attribute is true, this attribute, together with the Current Scene attribute, indicates the currently active scene.
0x0003| bool, read-only| Scene Valid
If true, the scene identified by Current Group and Current Scene is currently active, i.e. all device attribute values match the values in the scene fieldset.
0x0004| bitmap8 , read-only| Name Support
Command supported
C ommand | Description |
---|
0x00
| Add Scene
Adds a scene with or without a scene field set.
0x01
| View Scene
Returns the scene field set, name and transition times for a scene.
0x02| Remove Scene
Removes a scene from the scene table.
0x03
| Remove All Scenes
Removes all scenes that belong to a particular group.
0x04
| Store Scene
Stores the device’s current state as a scene or updates a previously stored scene accordingly.
0x05
| Recall Scene
Reverts the device’s current state using the values from the previously stored field set.
Groups-0x0004 (Server)
Attributes supported
C ommand | Description |
---|
0x00
| Add Group
Adds the endpoint to a group.
0x01
| View Group
Determines whether the device belongs to a group and returns the group name, if supported.
0x03
| Remove Group
Removes this endpoint from the specified group. Also removes all scenes that refer to this group.
0x04
| Remove All Groups
Removes this endpoint from all groups. Also removes all scenes that refer to any of the existing groups.
0x05
| Add Group if Identifying
Adds this endpoint to the group, if the endpoint is identifying.
Thermostat-0x0201(Server)
Attributes supported
**Attribute** | Type | Description |
---|
0x0000
|
int16S,skrivebeskyttet/ int16S, read-only
| reportable Local Temperature Attribute This is room temperature, the maximum resolution this format allows is 0.01 ºC.
0x0001
|
int16S,skrivebeskyttet/ int16S, read-only
| reportable Outdoor Temperature
This is floor temperature, the maximum resolution this format allows is 0.01 ºC.
0x0002
|
bitmap8, read-only
| Occupancy
When this flag is set as 1, it means occupied, Occupied Heating Set point will be used, otherwise Unoccupied Heating Set point will be used.
0x0010
|
Int8S, reportable
| Local Temperature Calibration
Room temperature calibration, range is
-30-30, the maximum resolution this format allows 0.1°C. Default value: 0
0x0011| int16S, rapporterbar/ int16S, reportable| OccupiedCoolingSetpoint
This system is not invalid.
0x0012
|
int16S, rapporterbar/ int16S, reportable
| OccupiedHeatingSetpoint
Range is 0-4000,the maximum resolution this format allows is 0.01 ºC. Default is 0xbb8(30.00ºC)
0x0014
|
int16S, rapporterbar/ int16S, reportable
| UnoccupiedHeatingSetpoint
Range is 0-4000,the maximum resolution this format allows is 0.01 ºC. Default is 0x258(6.00ºC)
0x001B
| Map16,skrivebeskyttet, rapporterbar/
Map16, read-only, reportable
| HV A C relay state/ hermostatRunningState
Indicates the relay on/off status, here only supports bit0( Heat State)
Proprietary Attributes:
E gensk ap / Attribute| Type| M anuf
actur er code/ Manufacturer code| Description|
---|---|---|---|---
0x0000
|
ENUM8,
rapporterbar
/ENUM8,
reportable
|
0x1224
| OperateDisplayLcdBrightnesss OLED brightness when operate the buttons:
Value=0 : Low Level Value=1 : Mid Level(default) Value=2 : High Level
OLED brightness when operate the buttons:
Value=0 : Low Level Value=1 : Mid Level(default) Value=2 : High Level
|
0x1002
|
ENUM8,
rapporterbar
/ENUM8,
reportable
|
0x1224
| FloorSenserType Value=5 : NTC 12K/25 Value=4 : NTC 100K/25 Value=3 : NTC 50K/25
Select external (Floor) sensor type:
Value=1 : NTC 10K/25 (Default) Value=2 : NTC 15K/25
Value=5 : NTC 12K/25 Value=4 : NTC 100K/25 Value=3 : NTC 50K/25
Select external (Floor) sensor type:
Value=1 : NTC 10K/25 (Default) Value=2 : NTC 15K/25
|
0x1003
|
ENUM8,
rapporterbar
/ENUM8,
reportable
|
0x1224
| ControlType
The referring sensor for heat control:
Value=0 : Room sensor(Default) Value=1 : floor sensor
Value=2 : Room+floor sensor
|
0x1004
|
ENUM8,
rapporterbar
/ENUM8,
reportable
|
0x1224
| PowerUpStatus
Value=0 : default mode
The mode after reset power of the device:
Value=1 : last status before power off (Default)
|
0x1005
| INT8S,
rapporterbar / INT8S,
reportable
|
0x1224
| FloorSenserCalibration
The temp compensation for the external (floor) sensor, range
is -30-30, unit is 0.1°C. default value 0
|
| INT8S,| | DryTime|
rapporteur / INT8S,
reportable
| 0x1224|
0x1006| The duration of Dry Mode, range is 5-100, unit is min. Default value
is 5.|
0x1007
|
ENUM8,
rapporterbar
/ENUM8,
reportable
|
0x1224
| ModeAfterDry
The mode after Dry Mode: Value=0: OFF
Value=1 : Manual mode Value=2 : Auto mode –schedule (default)
Value=3 : Away mode
|
0x1008
| ENUM8,
rapporterbar
/ENUM8,
reportable
|
0x1224
| TemperatureDisplay
Value=0 : Room Temp (Default) Value=1 : Floor Temp
|
Command supported
Simple Meter-0x0702 (Server)
Attributes supported:
E gensk ap / Attribute | Type | Description |
---|---|---|
0x0000 | unsigned48, read only, reportable | CurrentSummationDelivered |
Indicates the current amount of electrical energy delivered to the load.
0x0200| bitmap8, read-only| Status
Flags indicating current device status, always is 0x00.
0x0300| bitmap8, read-only| UnitOfMeasure
The unit of metering data, this is always kWh(0x00).
0x0303| bitmap8, read-only| SummationFormatting
The decimal point on the left and right sides of the data, this is always 0x00
0x0306| bitmap8, read-only| MeteringDeviceType
Metering data type, this is always Electric Metering (0x00)
Electrical Measurement-0x0b04(Server)
Attributes supported:
Attributes supported
Alarm-0x0009(Server)
Please set a valid value for ACAlarmsMask of Electrical Measurement.
The Alarm Server cluster can generate the following commands
CmdID | Description |
---|---|
0x00 | Alarm: |
The alarm code of Electrical Measurement is 0, Proprietary command, Manufacturer code=0x1224
ID | Description |
---|---|
0x00 | Room air temperature over heat, not alarm code |
Time-0x000A(server)
The Time cluster is a general cluster for time it is based on a UTC time in seconds since 0 hrs 0 mins 0 sec on1st January 2000. Refer to [Z2] for ZigBee specification of the time cluster. The metering device will use this clusters as a client – provided that a suitable Time Server is available on the network (most likely on the Gateway/concentrator) If the device has bound TIME cluster, then the device will acquire the value of Time (0x0007) spontaneously.
OccupancySensing-0x0406(client)
The attributes that can be received:
Attribute | Type | Description |
---|---|---|
0x0000 | bitmap8,/bitmap8, | Occupancy |
Bit 0 specifies the sensed occupancy as follows:1=occupied,0=unoccupied. This flag bit will affect the Occupancy attribute of HVAC cluster, and the operation mode.
Thermostat User Interface Configuration- 0x0204(Server)
Attributes supported
E gensk ap / Attribute| Type|
Beskrivelse/Description
---|---|---
0x0000| Enum8, reportable| TemperatureDisplayMode
0x00 Temperature in, only support.
0x0001| Enum8, reportable| KeypadLockout
0x00 No Lockout, 0x01 – 0x05 lockout
Application Endpoint #2–OTA
**Attribute** | support ed | Description |
---|---|---|
0x0000 | server | Basic |
0x0003 | server | Identify |
0x0019 | Klient/Client | OTA Upgrade |
Pull-oriented firmware upgrade. Searches the network for mating servers and allows the server to control all stages of the upgrade process, including which image to download, when to download, at what rate and when to install the downloaded image.
Ota complies to standard Zigbee protocol.
Namron AS-Nedre Kalbakkvei 88 B N-1081 Oslo-Norway