HITACHI PC-ARCHE Eco Compact Wired Remote Controller Instruction Manual

June 11, 2024
Hitachi

HITACHI PC-ARCHE Eco Compact Wired Remote Controller

SCAN QR

https://docs.hitachiaircon.com/PC-ARCH-E

Specifications in this manual are subject to change without notice in order that Hitachi may bring the latest innovations to their customers. Whilst every effort is made to ensure that all specifications are correct, printing errors are beyond Hitachi’s control; Hitachi cannot be held responsible for these errors

CAUTION

  • This product shall not be mixed with general house waste at the end of its life and it shall be retired according to the appropriated local or national regulations in a environmentally correct way.
  • Due to the refrigerant, oil and other components contained in heat pump, its dismantling must be done by a professional installer according to the applicable regulations. Contact to the corresponding authorities for more information.

The English version is the original one; other languages are translated from English. Should any discrepancy occur between the English and the translated versions, the English version shall prevail.

SAFETY SUMMARY

Hitachi cannot anticipate every possible circumstance that might involve a potential hazard.

DANGER
Perform electrical work according to the Installation Manual. As for the electrical wiring work and check, turn OFF the main power supply before opening/closing the service cover of indoor unit. If service cover is opened with main power supply left on, it may result in an electrical shock.

CAUTION

  • DO NOT pour water into the remote controller. This product is equipped with electrical parts. If poured, it will cause a serious electrical shock.
  • DO NOT perform installation work and electrical wiring connection by yourself. Contact your Hitachi distributor or dealer and ask them for installation work and electrical wiring by a service person.
  • DO NOT install the product in places where oil vapour or oil are dispersed, in the vicinity of hot springs (in a sulfuric environment), where the generation, flow, accumulation or leakage of flammable gas is detected, or in salty, acid or alkaline environments.
  • DO NOT install the controller and its cables within approximately 3 meters from strong electro­magnetic wave radiators such as medical equipment. In case that the controller is installed in a place where there is electromagnetic wave radiation, shield the controller and cables by covering them with a steel box and running the cable through a metal conduit tube.

NOTE

  • The installer and system specialist shall comply with local regulations or standards for safety. The following standards may be applicable, if local regulations are not in force: International Organization for Standardization, ISO5149 or European Standard, EN378 or Japan Standard, KHKS0010.
  • This appliance must be used only by adult and capable people, having received the technical information or instructions to handle it properly and safely.
  • Children should be supervised to ensure that they do not play with the appliance.
  • Important : Please read and understand this manual before using this remote controller.

If you have any questions, contact your Hitachi distributor or dealer.

INSTALLATION

Select a suitable place for operation and determine the installation place of the controller with the customer acceptance. Do not install the controller in a place where it is at the reach of children.The controller has a built-in thermistor; do not install it in places where it may become excessively affected by other equipment, such as indoor units, water pipes, radiators, etc. Select an installation place where the average room temperature can be detected, where the remote control is not directly exposed to the sun or heat sources,  and where it is not affected by outdoor air currents from opening and closing doors.Prior to the installation work, ensure that surface is flat and sufficiently strong and then fix the unit securely. Check the contents and the quantity of the accessories in the packing.

HITACHI-PC-ARCHE-Eco-Compact-Wired-Remote-Controller-
FIG-3

  • A – Remote control switch for operation control
  • B – 2 M4x16 screws for fixation of the holding bracket onto the wall
  • C -1 Instruction Manual
  • D – 1 Connecting wire (300 mm length)

When arranging the wired remote controller and other controllers vertically, place them at least 2 inches (50mm) apart. (iii).

Installation Procedure

Insert the edge of the slotted screwdriver into the groove at the bottom of the holding bracket, push and turn the slotted screwdriver to separate and remove the controller from the holding bracket.

HITACHI-PC-ARCHE-Eco-Compact-Wired-Remote-Controller-
FIG-5

  • A – Groove part
  • B – Approx. 6mm
  • C – Slotted screwdriver
  • D – View from the bottom side
  • E – Wall mount
  • F – Tabs for attachment of the controller

NOTE
Do not insert the slotted screwdriver into the tab part beside the groove. The tab may be dam­aged and the wired remote controller cannot be installed.

Attach the controller to the holding bracket and connect the cable as follows:
In Case of Exposing the Controller Cable Fix the holding bracket onto the wall with screws (accessory).

Attach the stopper (plastic band) to the cable at the inner side of the draw- out hole.

HITACHI-PC-ARCHE-Eco-Compact-Wired-Remote-Controller-
FIG-7

  • B – Cable
  • C – Band stopper (Field-supplied)
  • D – Draw-out hole
  • E – Plug the connector of the connecting wire into the CN1.
  • F – Connect wire stuck in the slot.

Attach the stopper (plastic band) to the cable at the inner side of the draw- out hole.

When Using Junction Box

HITACHI-PC-ARCHE-Eco-Compact-Wired-Remote-Controller-
FIG-8

  • Prepare the optional field-supplied Implanted Junction Box.
  • Feed the cable through the conduit tubing in the wall.
  • Connect the accessory cable to the field-supplied cable by soldering. Insu-late the connecting part with tape. (G)
  • Secure the holding bracket to the junction box with M4 screws.

Attach the controller body to the mounted holding bracket. Be careful not to pinch the cable when attaching it. After installation, peel away the protective film from the LCD screen.

ELECTRICAL WIRING

DANGER
Always make sure to turn off the power of the indoor unit when performing electrical wiring work. Performing electrical wiring work with the power turned on can damage the circuit boards of the indoor unit and the remote control switch.

Wiring Example (Using a twist pair cable with shield tube: 1P-0.75 mm2 or more)

HITACHI-PC-ARCHE-Eco-Compact-Wired-Remote-Controller-
FIG-10

NOTE

  • Use a 0.3 to 0.75 mm2 cable for connection.
    The maximum total cable length is:

    • If 3 controllers (Unit + 2 zone thermostats) are installed: 25 m each one, for a combined maximum of 75 m.
    • If 2 controllers (Unit + 1 zone thermostats) are installed : 50 m each one, for a combined maximum of 100 m.
    • If 1 controller (Unit) is installed : up to 100 m.
  • If total cable length exceeds 30 m, use a twist pair cable with shield tube (1P ­ 0.75 mm2). The use of cables other than those specified above can cause malfunction due to the effect of noise.

  • Keep a clearance of more than 30 cm between the transmission line (remote control switch cable and transmission wires) and the power source of indoor units. Otherwise, the heat pump may not operate properly or malfunction may occur due to the effect of power source noise.

  • Refer to the documentation provided with each unit for the proper settings when performing electrical wiring work between the remote control switch and the indoor units.

  • No gap shall exist between the remote control switch cable and the hole of the remote control switch case. If there is a gap, cover the gap with vinyl tape. Otherwise, malfunction may occur due to the entrance of water droplets or insects.

  • In case of setting up two or more remote control switches (Main and Subs), follow the contents of the supplied technical documentation of the indoor units in order to select the appropriate functions in the main and sub remote control switches. Upon completion of settings, turn off the power supply of all the indoor units connected to the remote control switches.

SWITCH NAMES AND FUNCTIONS

HITACHI-PC-ARCHE-Eco-Compact-Wired-Remote-Controller-
FIG-11

NOTE

  • The supplementary information about the purchased products is available through the QR printed in the front cover.
  • In case that no access to the website or files are not readable, please contact your Hitachi dealer or distributor.
  • The backlight turns off 30 s after the last operation. If you press any switch, the backlight is turned on. (The switch pressed to turn on the backlight is not functional.)
  • Make sure to press the buttons lightly with your fingertips.
  • Do NOT press the buttons or anything with sharp points, such as a ball point pen. This may damage the controller.

Johnson Controls-Hitachi Air Conditioning Spain, S.A.U. Ronda Shimizu, 1 – Polg. Ind. Can Torrella 08233 Vacarisses (Barcelona) Spain Copyright 2023 Johnson Controls-Hitachi Air Conditioning Spain, S.A.U. All rights reserved.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals