SuperFish 7500 Pond Clear UVC User Manual
- June 17, 2024
- SuperFish
Table of Contents
SuperFish 7500 Pond Clear UVC
Specifications
-
Model : Pond Clear UVC 7500
-
UV-lamp : 9 Watt
-
Max. pump capacity : 5,000 L/h
-
Pond content : 7,500 L
-
Hose connectors
-
Cable length
-
Model : Pond Clear UVC 15000
-
UV-lamp : 18 Watt
-
Max. pump capacity: 10,000 L/h
-
Pond content: 15,000 L
-
Hose connectors
-
Cable length
Product Usage Instructions:
Safety Instructions
Always follow the safety instructions for safe use of the device to avoid endangering persons or the environment.
Function
The UVC device ensures a clear pond within 14 days by producing ultraviolet light with a wavelength of 254 nm. It combats floating algae and reduces harmful bacteria without affecting the pond water’s pH value. Safe for fish and plants.
Installation
- Place the unit head with fitted UV-lamp and quartz glass back into the housing correctly.
- Lock the green switch to secure the unit.
Maintenance
Refer to Fig. L for detailed components and their functions for maintenance.
Recycling
If the product is discarded, do not dispose of it with normal household waste. Hand it in at an official collection center or return it to the dealer when purchasing a similar new product for recycling.
Warranty
Refer to the warranty information provided for details on coverage and terms.
FAQ
- Q: Is the UVC radiation harmful to fish and plants?
- A : No, the UV radiation is safe for fish and plants as it does not affect the pH value of the pond water.
- Q: How often should the UV lamp be replaced?
- A : The UV lamp should be replaced according to the manufacturer’s guidelines, typically after a certain number of operating hours to maintain effectiveness.
- Q: Can I install the device myself?
- A : Installation should be done following the provided instructions carefully to ensure proper functioning and safety.
General instructions
Read this manual carefully before using this device. Keep this manual for future reference.
Meaning of symbols
The following warning symbols and/or signal words are used in this manual:
DANGER!
This means an imminent danger due to electric current. Failure to follow the
safety instructions can result in serious or fatal injury and/or serious
damage to the product or environment.
WARNING!
This means a dangerous situation due to UV-C radiation. Failure to follow the
safety instructions can result in serious eye damage and damage to the skin.
WARNING!
This means a dangerous situation. Failure to follow the safety instructions
can result in moderate or minor personal injury and/or damage to the product
or environment.
NOTICE!
This means caution, useful information or advice. Fig. … This refers to the
relevant drawing … on pages 2 and 3 of this manual.
Meaning of the symbols on the device itself:
This UVC device produces harmful radiation, direct contact can be dangerous
for the eyes and skin. Always turn off the UV lamp before opening.
This device complies with all applicable EU standards.
This device may not be disposed of with normal household waste but must be
collected separately for recycling.
Use
Suitable for outdoor use, for pond purposes.
- The UVC device may only be connected if there is a sufficient flow of water.
- This UVC should be only used for cleaning pond water and the water temperature should not exceed 35°C. It should never be used for other liquids or chemicals.
Safety
Always follow the safety instructions below for safe use of the device.
Failure to follow these instructions may endanger persons or the environment.
- WARNING! This UVC device emits UV-C radiation, which can cause serious eye damage and/or damage to the skin. The UV lamp must therefore always be installed completely shielded from the eyes.
- Never look at a burning UV lamp. Do not switch on the lamp until it is fully shielded installed and fully submerged.
- This device must be supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30 mA.
- Ensure the voltage shown on the label matches the main supply voltage.
- This device must be connected to an earthed socket.
- Protect the socket and plug against moisture. Use a drip loop to ensure that water cannot reach the socket via the cord (see Fig. A).
- Don’t use the product if the device, quartz glass, cord or plug is damaged. Replace the quartz glass or return the device to your dealer for repair or recycling.
- If the power cord or plug of the UVC is damaged, the unit head should be replaced.
- Be careful with the combination of water and electricity. Do not operate with wet hands. Dry hands before carrying out maintenance.
- Always switch off all devices in the pond before maintenance. Disconnect the plug(s) from the socket.
- NOTICE! The UV lamp becomes warm. Allow the lamp to cool for at least 10 minutes before carrying out maintenance.
- In the event of frost or the risk of frost, appropriate precautions must be taken to prevent it from freezing.
- This device can be used by children aged 8 years and above, persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge, if they have been given supervision or instructions concerning the use of the device in a safe way and understand the hazards involved. Children shall not play with the device. Cleaning and maintenance of the device shall not be done by children without supervision.
- Modifications to the device may affect the safety. The warranty will also expire.
- Aquadistri is not liable for any problems, damage or accidents due to incorrect use of this device.
Function
The UVC device ensures a clear pond within 14 days. The UV lamp produces ultraviolet light is set to maximize effectiveness, with a wavelength of exactly 254 nm. The UV radiation combats floating algae without the use of chemicals and reduces harmful bacteria and germs. The UV-C radiation does not affect the pH value of the pond water and is safe for fish and plants.
Installation
- NOTICE! Before installation, check the quartz glass for any breakage. Always install the UVC device outside the pond, securely so it cannot fall into the pond. A pump transports the water from the pond through the UVC device and then through the filter back into the pond. See technical data for the correct pump capacity. Purification bacteria in the filter do not come into contact with the UV light, therefore the biological filtration is not adversely affected. Secure the hoses with hose clamps.
- Fig. B Cut the hose connectors (a) at the same diameter as the diameter of the hose. Unscrew the hose connectors from the UVC device before making cuts to avoid damaging the UVC device.
- Screw the hose connectors with the rubber gaskets (b) back onto the UVC device.
- Fig. C Connect the pump and filter to the hose connectors of the UVC device using pond hoses. Secure the hoses with hose clamps.
- Switch on the pump and check for any leaks.
- Then turn on the UVC device by plugging in the power cord.
- Fig. D Check the operation of the UV lamp via the light indicator on the UVC device.
- To avoid UVC overheating, switch off the UVC device when no water is flowing past it.
Maintenance
- Check monthly if UV lamp is burning via the light indicator on the UVC device.
- Remove the plug from the socket before carrying out maintenance!
- The UVC device should be cleaned twice a year. As soon as algae growth increases, check the UVC device and UV lamp and clean the whole or exchange the UV lamp as needed.
- The lamp is hot, wait 10 minutes after switching off before opening the UVC device.
- Ensure that the water is drained out of the UVC device first, before opening the device.
- Fig. E Slide the green switch lock (o) to unlock the electrical part/unit head and housing.
- Turn the unit head (p) counter-clockwise against the stop and carefully pull it out of the housing.
- Clean the inside of the housing (e) with a clean brush or cloth and rinse with clean tap water. Fig. F Loosen the locking screw (n) from the unit head, screw off the locknut (g). Pull off the quartz glass including the rubber gasket (h+l) by a slight rotary movement (Tip: use work gloves).
- Carefully clean the quartz glass outer face with a soft cloth and SuperFish Pump & UVC Clean. After cleaning, thoroughly rinse the quartz glass with clean tap water and check for damage. Replace the quartz glass if it shows any damage (to prevent glass breakage). Quartz glass replacement kit for the Pond Clear UVC 7500 (Art. 06011305) and for the Pond Clear UVC 15000 (Art. 06011310).
- The UV-lamp should be replaced annually, as the lamp may still burn but no longer emits enough UV radiation (maximum 8000 operating hours). Replacement lamp for Pond Clear UVC 7500: SF UV PL-lamp 9 W G23-167 mm (Art. 06011015) and for Pond Clear UVC 15000: SF UV PL-lamp 18 W G23-236 mm SP (Art. 06010140).
- Fig. G Remove the old lamp (j) together with clip (i) and tube protection ring (k) and remove the O-ring (m).
- Fig. H Clean the unit head (p) and O-ring (m) and put the O-ring back onto the unit head. Slide the tube protection ring (k) over a new UV-lamp, and put the clip (i) on the end of the UV-tube.
- Fig. I Insert the new UV lamp (j) in the fitting of the unit head.
- Fig. j Slide the quartz glass with the conical rubber gasket (h+l) gently over the UV lamp and insert it in the unit head (grease the outside of the rubber gasket with some petroleum jelly).
- Fig. K Slide the locknut (g) over the quartz glass and tighten it rigidly onto the unit head until the recess is positioned over the screw hole. This requires some force (use work gloves).
- Place back the locking screw (n) to lock the locknut.
- Fig. L Place the unit head (p) with fitted UV-lamp and quartz glass back into the housing (e) correctly and lock the green switch (o).
- Check the whole assembly for possible leaks and check if the UV lamp is working.
- a.Hose connector
- b. Rubber gasket
- c. Clip
- d. Self-tapping screw
- e. UVC housing
- f. Fixing foot
- g. Quarts locknut
- h. Quartz glass
- i. UV tube clip
- j. UV tube
- k. Tube protection ring
- l. Rubber gasket
- m. O ring
- n. Locking screw
- o. Switch lock (green)
- p. Electrical part/unit head
Recycling
This symbol indicates that this product (if it is discarded) may not be disposed of with normal household waste. Instead, it must be handed in at an official collection center (e.g. HWRC). Or can be returned to the dealer when purchasing a similar new product. Follow the applicable rules in your country for the separate collection of electrical and electronic products.
Separate collection and recycling are better for the environment, and public health and reduce waste.
Warranty
2 years manufacturer’s warranty on materials and construction defects. Devices must be returned complete with all components, accompanied with an official proof of purchase confirming a purchase date for any warranty claims. Incomplete devices of which parts are missing, and devices without proof of purchase are not eligible for warranty. After receiving and checking, we will determine whether the device will be repaired or replaced. For a device repaired or replaced under warranty, the remaining time of the original warranty period applies. Carefully read the instructions on installation, use and maintenance. Damage due to incorrect use, damage due to contamination or not cleaning the device, glass breakage and damage to the cord are not covered by the warranty.
Always keep the proof of purchase, without proof of purchase the warranty will be void!
Important, clean you UVC device at least twice a year!
Dirt and calcification reduce the UV-light permeability. Descale your quartz glass at least twice a year, for a smooth, long-term use. In areas with extremely hard water you may need to descale more often. Technical problems caused by scale are not under warranty. For cleaning and descaling the quartz glass special SuperFish Pump & UVC Clean is available at your dealer.
Date of purchase / --_____
Dealer stamp ………………
- www.aquadistri.com
- Vlietweg 8, 4791 EZ Klundert, The Netherlands,
- info@aquadistri.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>